2011 DRESDEN NUCLEAR POWER STATION INITlAL EXAMINATION PROPOSED EXAM FILES

Exelon Generation Company, LLC www.exeloncorp.com Exelan.

Dresden Nuclear Power Station Nuclear 6500 North Dresden Road Morris, IL 60450-9765 10 CFR 55.40(b)

January 18,201 1 SVPLTR #11-0001 U. S.Nuclear Regulatory Commission - Region 111 ATTN: Operator Licensing Branch 2443 Warrenville Road - Suite 210 Lisle, IL 60532-4352 Dresden Nuclear Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-19 and DPR-25 NRC Docket Nos. 50-237 and 50-249

Subject:

Submittal of Integrated Initial License Training Examination Materials Enclosed are the examination materials in support of the Initial License Examination scheduled to begin the week of March 07,201 1, at the Dresden Nuclear Power Station.

This submittal includes the Senior Reactor Operator and Reactor Operator Written Examinations, Job Performance Measures, and Integrated Plant Operation Scenario Guides.

These examination materials have been developed in accordance with NUREG-1021, Operator Licensing Examination Standards for Power Reactors, Revision 9, Supplement 1. Please note that reference materials are attached to each individual examination question or item.

Some minor modifications have been made to the integrated examination outline in order to improve balance and content. These changes improve examination quality and are consistent with guidance in NUREG-1021, Revision 9, Supplement 1.

Some modifications or adjustments to the examination material may be required due to procedural changes that occur after this submittal.

In accordance with NUREG 1021, Revision 9, Supplement 1, Section ES-201, please ensure that these materials are withheld from public disclosure until after the examinations are complete.

Should you have any questions concerning this letter, please contact Mr. Dennis Leggett, Regulatory Assurance Manager, at (815) 416-2800. For questions concerning examination materials, please contact Frank Ferrero at (815)416-2620.

U. S. Nuclear Regulatory Commission - Region Ill Page 2 RespectfuIly, Site Vice President Dresden Nuclear Power Station

Enclosures:

(Hand delivered Operations Branch, NRC Region 111)

RO/SRO Composite Examination with references attached Control Room Systems and Facility Walk-Through Job Performance Measures with references attached Administrative Topic Job Performance Measures with references attached Integrated Plant Operation Scenario Guides Completed Checklists:

Administrative Topics Outline (Form ES-301-1)

Operating Test Quality Checklist (Form ES-301-3)

Simulator Scenario Quality Checklist (Form ES-301-4)

Transient and Event Checklist (Form ES-301-5)

Competencies Checklist (Form ES-301-6)

Written Exam Quality Checklist (Form ES-401-6)

Examination Security Agreements (Form ES-201-3)

Control Room / In-Plant System Outline (Form ES-301-2)

BWR Examination Outline (Form ES-401-1)

Generic Knowledge and Abilities Outline (Tier 3) (Form ES-401-3)

Record of Rejected WAS (Form ES-401-4)

Scenario Outlines (Form ES-D-1) cc (w/o Enclosures):

NRC Document Control Desk NRC Senior Resident Inspector

ES-301 Operating Test Quality Checklist Form ES-301-3 Facility:- Date of Examination: 3/7/11 Initials

1. GENERAL CRITERIA

-a

a. The operating test conforms with the previously approved outline; changes are consistent with P

sampling requirements (e.g., 10 CFR 55.45, operational importance, safety function distribution).

b. There is no day-to-day repetition between this and other operating tests to be administered during this examination. 3 I c. The operating test shall not duplicate items from the applicants audit test(s)(see Section D.l .a).
d. Overlap with the written examination and between different parts of the operating test is within acceptable limits.
e. It appears that the operating test will differentiatebetween competent and less-than-competent amlicants at the desianated license level.

H a.

2. WALK-THROUGH CRITERIA Each JPM includesthe following, as applicable:

initial conditions initiating cues references and tools, including associated procedures reasonable and validated time limits (average time allowed for completion) and specific designation if deemed to be time critical by the facility licensee operationally important specific performance criteria that include:

- detailed expected actions with exact criteria and nomenclature

- system response and other examiner cues

- statements describing important observations to be made by the applicant

- criteria for successful completion of the task

- identificationof critical steps and their associated performance standards

- restrictionson the sequence of steps, if applicable It Ensure that any changes from the previously approved systems and administrative walk-through outlines (Forms ES-301-1 and 2) have not caused the test to deviate from any of the acceptance criteria (e.g., item distribution, bank use, repetitionfrom the last 2 NRC examinations) specified on those forms and Form ES-201-2.

3. SIMULATOR CRITERIA The associated simulator operating tests (scenario sets) have been reviewed in accordance with Form ES-301-4and a copy is attached.

Printed Name / Si Date

a. Author
b. Facility Reviewer ()
c. NRC Chief Examine 1/J r/h
d. NRC Supervis NOTE:
  • The facility signature is not applicable for NRC-developed tests
  1. Independent NRC reviewer initial items in Column c; chief examiner concurrence is required.

ES-301, Page 24 of 27

ES-301 Simulator Scenario Quality Checklist Form ES-301-4 Facility: Dresden Date of Exam: 3/7/11 Scenario Numbers: 1 / 2 / 3 / 4 Operating Test Number: 10-1(2011-301)

Initials QUALITATIVE ATTRIBUTES a b" c#

1. The initial conditions are realistic, in that some equipment and/or instrumentation may be out of service, but it does not cue the operators into expected events.
2. The scenarios consist mostly of related events.
3. Each event description consists of the point in the scenario when it is to be initiated the malfunction(s) that are entered to initiate the event the symptoms/cues that will be visible to the crew.

the expected operator actions (by shift position) the event termination mint (if aoolicable)

4. No more than one non-mechanistic failure (e.g., pipe break) is incorporated into the scenario without a credible preceding incidentsuch as a seismic event.
5. The events are valid with regard to physics and thermodynamics.
6. Sequencing and timing of events is reasonable, and allows the examination team to obtain complete evaluation results commensurate with the scenario objectives. 3+
7. If time compression techniques are used, the scenario summary clearly so indicates.

Operators have sufficienttime to carry out expected activities without undue time constraints.

Cues are given.

8. The simulator modeling is not altered.

!!kit

2. Malfunctions after EOP entry (1-2)
3. Abnormal events (2-4)
4. Maior transients I1 -2)

&?I

5. EOPs enteredreauirina substantive actions (1 -2) 4B
6. EOP continaencies reauirina substantive actions 10-2)
7. Critical tasks (2-3)

ES-301, Page 25 of 27

ES-401 Written Examination Quality Checklist Form ES-401-6 Facility: Dresden Date of Exam: 3/7/11 Exam Level: RO SRO Initial Item Description a c b* c'

1. Questions and answers are technically accurate and applicable to the facility. 8 IrrS
2. a. NRC WAS are referenced for all questions.
b. Facilitv learnina obiectives are referenced as available.
3. SRO questions are appropriate in accordance with Section D.2.d of ES-401
4. The sampling process was random and systematic (If more than 4 RO or 2 SRO questions were repeated from the last 2 NRC licensing exam, consult the NRR OL program office).
5. Question duplicationfrom the license screeninglaudit exam was controlled as indicated below (check the item that applies) and appears appropriate:

the audit exam was systematically and randomly developed; or 2 the audit exam was completed before the license exam was started; or

- the examinations were developed independently; or

- the licensee certifies that there is no duplication; or

- other (explain)

6. Bank use meets limits (no more than 75 percent Bank Modified New from the bank, at least 10 percent new, and the rest new or modified); enter the actual RO / SRO-only WIj3 3 la qfl/o question distribution(s) at right.
7. Between 50 and 60 percent of the questions on the RO CIA exam are written at the comprehension /analysis level; the SRO exam may exceed 60 percent if the randomly selected KAs support the higher cognitive levels; enter 36
  • 8 3y 1 the actual RO I SRO auestion distributionfs) at riaht.

t give away answers

a. Author
b. Facility Reviewer r)
c. NRC Chief Examiner (#)
d. NRC Regional Supervisor Note:
  • The facility reviewer's initialdsignatureare not applicable &r NRC-developed examinations.
  1. Independent NRC reviewer initial items in Column "c"; chief examiner concurrence required.

ES-401, Page 29 of 33

ES-301 Competencies Checklist Form ES-301-6 Facility: Dresden Date of Examination: 3/7/11 Operating Test No.: 10-1 (2011-301)

Notes:

(1) Includes Technical Specification compliance for an RO.

(2) Optional for an SRO-U.

(3) Only applicable to SROs.

Instructions:

Check the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.

ES-301, Page 27 of 27

ES-301 Competencies Checklist Form ES-301-6 Facility: Dresden Date of Examination: 3/7/11 Operating Test No.: 10-1 (2011-301)

APPLICANTS Votes:

1) Includes Technical Specification compliance for an RO.
2) Optional for an SRO-U.
3) Only applicable to SROs.

Instructions:

Check the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.

ES-301, Page 27 of 27

ES-301 Competencies Checklist Form ES-301-6 Facility: Dresden Date of Examination: 3/7/11 Operating Test No.: 10-1 (2011-301)

I APPLICANTS I I Competencies SRO-I #5 SRO-I#6 I RO#3 I SCENARIO 1 1 1 2 3 Interpret/ Diagnose 1-6 1-7 1-7 Events and Conditions Comply With and Use 1-6 1-7 1-7 Procedures (1)

Operate Control 1. 3,!

Boards (2)

Communicate 1-6 1-7 1-7 and Interact Demonstrate 1-6 1-7 Supervisory Ability (3)

Somply With and 1.3 2.4 Jse Tech Specs. (3) qotes:

1) Includes Technical Specification compliance for an RO.
2) Optional for an SRO-U.
3) Only applicable to SROs.

Instructions:

Check the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.

ES-301, Page 27 of 27

ES-301 Competencies Checklist Form ES-301-6 Notes:

(1) Includes Technical Specificationcompliance for an RO.

(2) Optional for an SRO-U.

(3) Only applicable to SROs.

Instructions: