Submits Addl Info to Support AP600 Passive RHR Heat Exchanger Heat Transfer Correlations Analyses.Resulting Predicted Passive RHR Outlet Temps & Primary Sys Fluid Temps for Various Locations Along Tube Listed in Encl 1
ML20211B290
Person / Time
Site: 05200003
Issue date: 09/18/1997
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Quay T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NSD-NRC-97-5322, NUDOCS 9709250141
Download: ML20211B290 (3)


Text

- - - _ _ - _ .. .. . _ . .. .. .

A

-' a g

?4 Westinghouse Energy Systems g345 , ,g33 Electric Corporation DCP/NRC1032 NSD-NRC-97 5322 Docket No.: 52-003 Sep; ember 18,1997 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555 l

ATTENTION: T. R. QUAY

SUBJECT:

ADDTI'lONAL INFORMATION TO SUPPORT AP600 PASSIVE RESIDUAL llEAT REMOVAL (PRilR) IIEAT EXCilANGER llEAT TRANSFER CORRELATIONS ANALYSES 5

Dear Mr. Quay:

In response to your letter dated May 9,1997, Westinghouse has performed additional analyses to

[ predict the perfonnance of the ROSA PRilR heat exchanger for two tests (AP-80-01 station blackor and AP-CL-041/2 inch cold leg break). The resulting predicted PRilR outlet temperatures and primary system Duid temperatures for various locations along the tube are listed in Enclosure I for the time periods requested for each test.

These results were determined by applying the PR11R heat transfer correlations reported in WCAP-12980, "AP600 Passive Residual lleat Removal lleat Exchanger Test Final Repor," Revision 2, September,1996. Test con 0guration and layout information was obtained from the " Updated Final Design Report for the Project of ROSA Facility Modification," Volume 1, February,1994.

This report submittal closes, from Westinghouse's perspective, open items 25 (RAI 952.94),1617 (DSER 0121.3.31),3226 (DSER 0121.6.1.6-1), and 3395 (RAI 440.567). As a result, the Westinghouse status column will be changed to " Closed" in the Open item Tracking System (OITS)

. for these four open items. The NRC should review this response and inform Westinghouse of the status of these open items to be designated in the "NRC Status" column of the OITS.

Please contact Mr. Eugene J. Piplica at (412) 374 5310 if you have any questions concerning this transmittal.

A 8 Brian A. icintyre, Mana[er M m

(;I i {

.\dvanced Plant Safety and Licensing 1 jml Enclosure 97092501dE970918 PDR A-ADOCK 05200003 g PDR y.

l$lll * '

k ,k

t ,

J

. DCP/NRC1032 NSD-NRC-97 5322 September 18,1997 cc: W, ilufTman, (NRC) (w/ Enclosure)

A. Levin (NRC) (w/ Enclosure)

R. Landry (NRC) (w/ Enclosure)

P.A. Boehnert, ACRS (w/ Enclosure)

N. J. Liparuto, Westinghouse (w/o Enclosures) 31s ta mpf

Enclosure I to DGP/NRp1032 i NSp-NRC 97-5322 September 18,1997 AP BO-01 Time 15000 sec 19000 sec 30000 sec 45000 sec 49000 see PRHR Outlet Temp 154.4 172.7 202.1 222.2 221.7 Primary Temp @1.52 m 277.7 274.7 271.9 272.3 272.6 Primary Temp @3.52 m 237.9 244.7 244.4 244.0 244.0 Primary Temp @ 6.2 m I89.0 210.2 224.7 228.9 228.7

-All temperatures are in degrees Fahrenheit AP-CL-04 Time 2000 sec 8000 sec 14000 see PRHR Outlet Temp 139.7 158.6 185.6 Primary Temp @1.52 m 357.0 282.9 273.1 Primary Temp @3.52 m 272.1 248.5 244.5 Primary Temp @ 6.2 m 187.8 193.0 216.0

~ All temperatures are in degrees Fahrenheit "l b