NSD-NRC-96-4858, Forwards Suppl Info on AP600 Radioactive Waste Mgt Sys Design

From kanterella
Jump to navigation Jump to search
Forwards Suppl Info on AP600 Radioactive Waste Mgt Sys Design
ML20134D887
Person / Time
Site: 05200003
Issue date: 10/23/1996
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Quay T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20134D892 List:
References
NSD-NRC-96-4858, NUDOCS 9610310082
Download: ML20134D887 (1)


Text

- -. .~ -_.. _ _ - - - _ - - _ _ - - . . _ _ - -

O Westinghouse Energy Systems Ba 355 Pittsburgh PennsyNania 15230-0355 Electric Corporation NSD-NRC-96-4858 i DCP/NRC0636

  • l Docket No.: STN-52-003 October 23,1996 Document Control Desk l U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION: T.R. QUAY

SUBJECT:

AP600 RADIOACTIVE WASTE MANAGEMENT SUPPLEMENTAL INFORMATION

Dear Mr. Quay:

The enclosure to this letter provides information on the AP600 Radioactive Waste Management System design. This design is discussed in Chapter 11 of the AP600 Standard Safety Analysis Report (SSAR).

Requests for Additional Information (RAl) were provided to Westinghouse as part of the NRC review of the radioactive waste management systems and processes. Westinghouse responses to these RAls were utilized in the preparation of the NRC's November 1994 Draft Safety Evaluation Report l (DSER).

The enclosed information consolidates, into a single reference, RAI responses utilized by NRC staff as a basis for acceptance as documented in the November 1994 DSER. These RAI responses have been reviewed and updated where necessary to be consistent with Revision 9 of the AP600 SSAR.

Please contact John C. Butler on (412) 374-5268 if you have any questions concerning this transmittal.

A/ /

Brian A. McIntyre, M hager Advanced Plant Safety and Licensing Enclosures k f cc: T. Kenyon, NRC (w/o Enclosures / Attachments)  ;

D. Jackson, NRC l- N. J. Liparulo, Westinghouse (w/o Enclosures / Attachments) -

[

a4 l

9610310082 961023 PDR ADOCK 05200003 A PDR