. y Westinghouse Energy Systems Ba 355 Pmsburgh Penrtylvama 15230 0355 Electric Corporation NTD-NRC-94-4058 DCP/NRC0(X)3 Docket No.: STN-52-003 February 3,1994 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION: MR. R. W. BORCHARDT

SUBJECT:

FRAMEWORK FOR AP600 SEVERE ACCIDENT MANAGEMENT GUIDANCE (WCAP-13913)

Dear Mr. Borchardt:

Enclosed with Mr. Ilasselberg's copy of this letter are fifteen copics of WCAP-13913, " Framework for . f AP600 Severe Accident Management Guidance" (Proprietary).

The Westinghouse Electric Corporation copyright notice, proprietary information notice, application for withholding and affidavit are attached.

This submittal contains Westinghouse proprietary information consisting of trade secrets, commercial information or financial information which we consider privileged or confidential pursuant to 10CFR9.17(a)(4). Therefore, it is requested that the Westinghouse proprietary information attached hereto be handled on a confidential basis and be withheld from public disclosures.

This material is for your internal use only and may be used for the purpose for which it is submitted.

It should not be otherwise used, disclosed, duplicated, or disseminated, in whole or in part, to any other person or organization outside the Commission, the Office of Nuclear Reactor Regulation, the Office of Nuclear Regulatory Research and the necessary subcontractors that have signed a prcprietary non-disclosure agreement with Westinghouse without the express written approval of Westinghouse. -

I i

s 24anas 42 O

Nh{W )t

,1 9402280459 940203

- 6 PDR ADOCK 05200003 A PDR

e d

NTD-NRC-94-4058 -2 February 3,1994 DCP/NRC0003 Correspondence with respect to the application for withholding should reference AW-94-582, and should be addresses to N. J. Liparuto, Manager of Nuclear Safety And Regulatory Activitics, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania, 15230-0355.

Please contact Brian A. McIntyre on (412) 374-4334 if you have any questions concerning this transmittal.

/s*

N. J. Liparulo, Manager n

Nuclear Safety & Regulatory Activities

/nja Enclosures cc: R. Ilasselberg, NRC T. Kenyon, NRC (w/o enclosure)

B.A. McIntyre, Westinghouse (w/o enclosure) 1493A

4 3

COPYRIGIIT NOTICE i

The reports transmitted herewith each bear a Westinghouse copyright notice. The NRC is permitted to make the number of copics of the information contained in these reports which are necessary for its '

internal use in connection with generic and plant-specific reviews and approvals as well as the issuance, denial, amendment, transfer, renewal, modification, suspension, revocation, or violation of a license, permit, order, or regulation subject to the requirements of 10 CFR 2.790 regarding restrictions on public disclosure to the extent such information has been identified as proprietary by Westinghouse, copyright protection not withstanding. With respect to the non-proprietary versions of these reports, the NRC is permitted to make the number of copics beyond those necessary for its internal use which are necessary in order to have one copy available for public viewing in the appropriate docket files in ,

the public document room in Washington, D.C. and in local public document rooms as may bc

required by NRC regulations if the number of copics submitted is insufficient for this purpose. The NRC is not authorized to make copics for the personal use of members of the public who make use of the NRC public document rooms. Copics made by the NRC must include the copyright notice in all instances and the proprietary notice if the original was identified as proprietary.

4 t

I a

l i

1 I

99 % 4

-l

- l l

l 1

i PROPRIETA'dY INFORMATION NOTICE Transmitted herewith are proprietary and/or non-proprietary versions of documents furnished to the l NRC in connection with requests for generic and/or plant specific review and approval, in order to conform to the requirements of 10 CFR 2.790 of the Commission's regulations concerning  !

the protection of proprietary information so submitted to the NRC, the information which is  !

proprietary in the proprietary versions is contained within brackets, and where the proprietary  ;

information has been deleted in the non-proprietary versions, only the brackets remain (the information 1 that was contained within the brackets in the proprietary versions having been deleted). The  ;

justification for claiming the information so designated as proprietary is indicated in both versions by l means of lower case letters (a) through (f) contained within parentheses located as a superscript l' immediately following the brackets enclosing cach item of information being identified as r,.sprietary or in the margin opposite such information. These lower case letters tric r to the types of information Westinghouse customarily holds in confidence identified in Section (4)(:i)(a) through (4)(ii)(f) of the affidavit accompanying this transmittal pursuant to 10 CFR2.790(b)(1). .

I E

i i

i 4

I t

i

}

03MA h

5 i

e i

, -