ML23137A396

From kanterella
Jump to navigation Jump to search

Framatome, Inc., Richland Nuclear Fuel Fabrication Facility’S Request to Amend License No. SNM-1227; and Approval of Criticality Safety Methods
ML23137A396
Person / Time
Site: Framatome ANP Richland
(SNM-1227)
Issue date: 05/17/2023
From: Travis Tate
Framatome
To: Lav S
Office of Nuclear Material Safety and Safeguards, Document Control Desk
Shared Package
ML23137A393 List:
References
TJT:23;009
Download: ML23137A396 (1)


Text

framatome Document Control Desk TJT:23;009 May 17. 2023 Page 1 Samantha Lav Chief Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington DC 20555-0001 ATTN: Document Control Desk

Subject:

Framatome Inc. Richland Nuclear Fuel Fabrication Facilitys Request to Amend License No. SNM-1227; Docket No. 70-1257 and Approval of Criticality Safety Methods

References:

(1) NRC License SNM-1227, Docket 70-1257 (2) Letter from Tim Tate to Tom Boyce (ML22236A587) Dated August 23, 2022.

Dear Ms. Lav; Via Reference 2, Framatome informed the NRC that Framatome planned to submit a License Amendment Request to extend the currently approved methodology for determining the minimum margin of sub-criticality to include enrichments up to 20 wt.% 235U. Framatome hereby requests the NRC approve extending this methodology to include enrichments up to 20 wt.%

235U. documents Framatomes SCALE 6.2.2 code validation efforts to support this request. After the NRC approves this request, Framatome will add attachment 1 to the reference section of Chapter 5 of SNM-1227 and will send an updated copy of this chapter to the NRC within six months of making the change. documents the supporting detailed calculations of Attachment 1 and is provided to assist in the review.

Framatome continues to commit to only use SCALE 6.2.2/KENO-VI and ENDF/B-VI1.1 Continuous Energy (CE) cross sections to support fuel fabrication process applications involving uranium enrichments greater than 5.0 wt.% 235U; if a newer version of SCALE/KENO-VI is adopted in the future, then that version of code will be validated using the methodology described in Attachment 1, which will be updated accordingly.

No changes in actual possession limits or any other license conditions are being requested at this time.

Document Control Desk May 17, 2023 TJT:23:009 Page 2 The information in Attachment 1 (E04-04-010 Ver. 1.0) and Attachment 2 (FS1-0067669 Rev.

1.0) are proprietary in accordance with 10 CFR 2.390(b)(4)(v), An affidavit supporting the proprietary nature of this information is attached.

If you have questions or require additional information, please feel free to contact Calvin Manning of my staff at 509-375-8327 or me at 509-375-8550.

T. J. Tate, Manager Environmental, Health, Safety & Licensing (E04-04-010, Ver. 1.0), SCALE 6.2.2 20 wt.% Enrichment Benchmark Validation Report (FS1-0067669, Rev. 1.0), SCALE 6.2.2 Criticality Safety Validation to 20 wt%

Enrichment cc:

Richard Jervey Project Manager

/sm Sincerely,

Document Control Desk May 17, 2023 TJT:23:009 Page 3 be:

L. G. Stephens W. L. Doane M. L. Crawford C. D. Manning File/LB