framatome August 31, 2022 YRS:22:005 U.S. Nuclear Regulatory Commission Attn: Document Control Desk (03-H8)

Director, Office of Nuclear Material Safety and Safeguards One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 License SNM-1227 Docket 70-1257

Subject:

Required Reporting of Effluents per 10 CFR 70.59 As required by 10 CFR 70.59, Framatome is reporting discharges of radioactive materials in the effluents from its nuclear fuels fabrication plant on Horn Rapids Road in Richland, Washington for the period from January 1 through June 30, 2022.

The total exposure from all stacks is 1.49E-05 mrem. Doses were determined using CAP88 Version 4.0.1.17.

If there are any questions, please contact me at (509) 375-8355 Very truly yours, cc:

LA Dudes, U.S. Nuclear Regulatory Commission, Region II P. J. Martell, State of Washington Department of Health C. Taylor, U.S. Nuclear Regulatory Commission, Region II J. Wood, Director, Office of Radiation Protection (WDOH)

Fra:matome Inc, 2101 Horn Rapids Road Richland, WA 99354 Tel: (509) 375-8100 www.framatome.ccirri

USNRC Document Control Desk August31,2022 I.

Gaseous Effluents (Continuously Sampled Stacks}

Reporting Period: January 1 - June 30, 2022 Stack: UO2 Building - Room 100 (K03}

Average Flow Rate: 12.05 cubic meters/second Uncertainty Concentration Estimate Radionuclide

{l:!Ci/ml}

{l:!Ci/ml}

Gross alpha 9.00E-16 4.00E-15 Gross beta 2.00E-15 6.00E-15 U-232 2.00E-24 9.00E-24 U-234 2.00E-18 9.00E-18 U-235 4.00E-17 2.00E-16 U-236 2.00E-17 1.00E-16 U-238 8.00E-16 4.00E-15 Stack: SF Building - NAF(K06}

Average Flow Rate: 5.64 cubic meters/second Uncertainty Concentration Estimate Radionuclide

{l:!Ci/ml}

{l:!Ci/ml}

Gross alpha 2.00E-16 3.00E-15 Gross beta 2.00E-15 1.00E-14 U-232 4.00E-25 6.00E-24 U-234 4.00E-19 6.00E-18 U-235 9.00E-18 1.00E-16 U-236 4.00E-18 7.00E-17 U-238 2.00E-16 3.00E-15 Stack: UO2 Building - Room 182 (K21}

Average Flow Rate: 3.90 cubic meters/second Radionuclide Gross alpha Gross beta U-232 U-234 U-235 U-236 U-238 Fra:matome Inc.

2101 Horn Rapids Road Richland, WA 99354 Tel: (509) 375-8100 www.framatome,cc:im Uncertainty Concentration Estimate

{l:!Ci/ml}

{l:!Ci/ml}

4.00E-15 2.00E-14 4.00E-15 2.00E-14 7.00E-24 3.00E-23 7.00E-18 3.00E-17 2.00E-16 8.00E-16 9.00E-17 4.00E-16 3.00E-15 1.00E-14 YRS:22:005 Page 2 Quantity Estimated MDC Released Exposure

{l:!Ci/ml}

11:!9.1

{mrem}

4.00E-17 1.61 E-01 NA 1.00E-16 3.18E-01

  • NA 8.00E-26 3.23E-10 1.90E-15 8.00E-20 3.23E-04 1.90E-09 2.00E-18 8.06E-03 4.75E-08 1.00E-18 4.03E-03 2.37E-08 4.00E-17 1.49E-01 8.76E-07 Quantity Estimated MDC Released Exposure

{l:!Ci/ml}

11:!9.1

{mrem}

8.00E-17 1.46E-02 NA 2.00E-16 2.04E-01 NA 2.00E-25 2.93E-11 2.44E-16 2.00E-19 2.93E-05 2.44E-10 4.00E-18 7.32E-04 6.10E-09 2.00E-18 3.66E-04 3.05E-09 8.00E-17 1.35E-02 1.13E-07 Quantity Estimated MDC Released Exposure

{l:!Ci/ml}

11:!9.1

{mrem}

1.00E-16 2.01E-01 NA 4.00E-16 2.38E-01 NA 2.00E-25 4.02E-10 3.60E-15 2.00E-19 4.02E-04 3.60E-09 6.00E-18 1.00E-02 9.00E-08 3.00E-18 5.02E-03 4.50E-08 1.00E-16 1.85E-01 1.66E-06

USNRC Document Control Desk YRS:22:005 August 31, 2022 Page 3 I.

Gaseous Effluents (Continuously Sampled Stacks)

Reporting Period: January 1 - June 30, 2022 Stack: ELO Building - Shop (K25)

Average Flow Rate: 1.38 cubic meters/second Uncertainty Quantity Estimated

, Concentration Estimate MDC Released Exposure Radionuclide

{!,!Ci/ml}

{!,!Ci/ml}

{!,!Ci/ml}

.il:!9}

{mrem}

Gross alpha 5.00E-16 1.00E-14 3.00E-16 1.05E-02 NA Gross beta 2.00E-15 2.00E-14 1.00E-15 5.06E-02 NA U-232 1.00E-24 2.00E-23 7.00E-25 2.10E-11 1.87E-15 U-234 1.00E-18 2.00E-17 7.00E-19 2.10E-05 1.87E-09 U-235 2.00E-17 5.00E-16 2.00E-17 5.26E-04 4.68E-08 U-236 1.00E-17 2.00E-16 8.00E-18 2.63E-04 2.34E-08 U-238 4.00E-16 9.00E-15 3.00E-16 9.?0E-03 8.63E-07 Stack: UO2 Building -ADU (K31)

Average Flow Rate: 3.60 cubic meters/second

  • There are several sampled effluent streams discharged via this stack.

Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!,!Ci/ml}

{!,!Ci/ml}

{!,!Ci/ml}

.il:!9}

{mrem}

Gross alpha 6.00E-15 7.00E-15 1.00E-16 1.59E-01 NA Gross beta 2.00E-14 2.00E-14 4.00E-16 7.05E-01 NA U-232 1.00E-23 1.00E-23 3.00E-25 3.17E-10 1.43E-15 U-234 1.00E-17 1.00E-17 3.00E-19 3.17E-04 1.43E-09 U-235 3.00E-16 4.00E-16 6.00E-18 7.94E-03 3.59E-08 U-236 1.00E-16 2.00E-16 3.00E-18 3.97E-03 1.79E-08 U-238 7.00E-15 7.00E-15 1.00E-16 1.46E-01 6.62E-07 Stack: UO2 Building - U3Oa (K37)

Average Flow Rate: 6.45 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!,!Ci/ml}

{!,!Ci/ml}

{!,!Ci/ml}

.il:!9}

{mrem}

Gross alpha 4.00E-16 4.00E-15 7.00E-17 4.13E-02 NA Gross beta 2.00E-15 1.00E-14 2.00E-16 2.53E-01 NA U-232 8.00E-25 8.00E-24 1.00E-25 8.27E-11 7.62E-16 U-234 8.00E-19 8.00E-18 1.00E-19 8.27E-05 7.62E-10 U-235 2.00E-17 2.00E-16 4.00E-18 2.0?E-03 1.91E-08 U-236 1.00E-17 1.00E-16 2.00E-18 1.03E-03 9.53E-09 U-238 4.00E-16 4.00E-15 7.00E-17 3.82E-02 3.52E-07

USNRC Document Control Desk YRS:22:005 August 31, 2022 Page 4 I.

Gaseous Effluents (Continuously Sampled Stacks)

Reporting Period: January 1 - June 30, 2022 Stack: Laundry Facility (K42)

Average Flow Rate: 2.43 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

ll!.91

{mrem}

Gross alpha 5.00E-16 7.00E-15 2.00E-16 1.88E-02 NA Gross beta 5.00E-15 2.00E-14 6.00E-16 1.81E-01 NA U-232 1.00E-24 1.00E-23 4.00E-25 3.76E-11 1.78E-15 U-234 1.00E-18 1.00E-17 4.00E-19 3.76E-05 1.78E-09 U-235 2.00E-17 4.00E-16 1.00E-17 9.40E-04 4.46E-08 U-236 1.00E-17 2.00E-16 5.00E-18 4.70E-04 2.23E-08 U-238 4.00E-16 7.00E-15 2.00E-16 1.73E-02 8.23E-07 Stack: ELO Building - Labs (K46)

Average Flow Rate: 6.65 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

ll!.91

{mrem}

Gross alpha 8.00E-16 6.00E-15 7.00E-17 8.49E-02 NA Gross beta 6.00E-15 1.00E-14 2.00E-16 5.70E-01 NA U-232 2.00E-24 1.00E-23 1.00E-25 1.70E-10 2.74E-15 U-234 2.00E-18 1.00E-17 1.00E-19 1.70E-04 2.74E-09 U-235 4.00E-17 3.00E-16 4.00E-18 4.25E-03 6.85E-08 U-236 2.00E-17 1.00E-16 2.00E-18 2.12E-03 3.43E-08 U-238 8.00E-16 5.00E-15 6.00E-17 7.84E-02 1.26E-06 Stack: ARF (K47)

Average Flow Rate: 1.25 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{l:!Ci/rril}

{!:!Ci/ml}

{!:!Ci/ml}

ll!.91

{mrem}

Gross alpha 2.00E-15 2.00E-14 4.00E-16 3.40E-02 NA Gross beta 2.00E-14 6.00E-14 1.00E-15 3.59E-01 NA U-232 4.00E-24 4.00E-23 7.00E-25 6.80E-11 1.11 E-15 U-234 4.00E-18 4.00E-17 7.00E-19 6.80E-05 1.11 E-09 U-235 9.00E-17 1.00E-15 2.00E-17 1.70E-03 2.78E-08 U-236 4.00E-17 5.00E-16 9.00E-18 8.50E-04 1.39E-08 U-238 2.00E-15 2.00E-14 3.00E-16 3.14E-02 5.13E-07

USNRC Document Control Desk YRS:22:005 August 31, 2022 Page 5 I.

Gaseous Effluents (Continuously Sampled Stacks)

Reporting Period: January 1 - June 30, 2022 Stack: SF Building - SWUR Room (K49)

Average Flow Rate: 3.75 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

(!,!Ci/ml)

(!,!Ci/ml)

(!,!Ci/ml) fi!.9.1 (mrem)

Gross alpha 3.00E-16 5.00E-15 1.00E-16 1.95E-02 NA Gross beta 3.00E-15 2.00E-14 4.00E-16 1.85E-01 NA U-232 7.00E-25 1.00E-23 2.00E-25 3.91 E-11 4.26E-16 U-234 7.00E-19 1.00E-17 2.00E-19 3.91E-05 4.26E-10 U-235 2.00E-17 2.00E-16 6.00E-18 9.77E-04 1.0?E-08 U-236 9.00E-18 1.00E-16 3.00E-18 4.89E-04 5.33E-09 U-238 3.00E-16

. 5.00E-15 1.00E-16 1.80E-02 1.97E-07 Stack: SF Building - SWUR POG (K50)

Average Flow Rate: 0.00 cubic meters/second

      • Stack did not operate durinQ the first half of 2022 Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

(!,!Ci/ml)

(!,!Ci/ml)

(!,!Ci/ml) fi!.9.1 (mrem)

Gross alpha 2.00E-15 NA Gross beta 2.00E-14 NA U-232 3.00E-24 U-234 3.00E-18 U-235 8.00E-17 U-236 4.00E-17 U-238 2.00E-15 Stack: Building 9 (K52)

Average Flow Rate: 3.40 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

(!,!Ci/ml)

(!,!Ci/ml)

(!,!Ci/ml) fi!.9.1 (mrem)

Gross alpha 3.00E-16 5.00E-15 1.00E-16 1.68E-02 NA Gross beta 2.00E-15 1.00E-14 4.00E-16 1.26E-01 NA U-232 6.00E-25 1.00E-23 3.00E-25 3.36E-11 5.26E-16 U-234 6.00E-19 1.00E-17 3.00E-19 3.36E-05 5.26E-10 U-235 1.00E-17 3.00E-16 7.00E-18 8.40E-04 1.32E-08 U-236 7.00E-18 1.00E-16 3.00E-18 4.20E-04 6.58E-09 U-238 3.00E-16 5.00E-15 1.00E-16 1.55E-02 2.43E-07

USNRC Document Control Desk YRS:22:005 August31,2022 Page 6 I.

Gaseous Effluents (Continuously Sampled Stacks)

Reporting Period: January 1 - June 30, 2022 Stack: SF Building - SWUR Shroud (K55)

Average Flow Rate: 0.00 cubic meters/second

      • Stack did not operate durinQ the first half of 2022 Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!,!Ci/ml}

{!,!Ci/ml}

{!,!Ci/ml}

il!.9.1

{mrem}

Gross alpha 7.00E-16 NA Gross beta 3.00E-14 NA U-232 1.00E-24 U-234 1.00E-18 U-235 3.00E-17 U-236 2.00E-17 U-238 6.00E-16 Stack: ELO Building - GSUR (K56)

Average Flow Rate: 3.05E-03 cubic meters/second

      • Stack did not operate the majority of the first half of 2022 Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!,!Ci/ml}

{!,!Ci/ml}

{!,!Ci/ml}

il!.9.1

{mrem}

Gross alpha 4.00E-15 7.00E-13 1.00E-13 3.11E-04 NA Gross beta 4.00E-14 3.00E-12 3.00E-13 7.52E-03 NA U-232 8.00E-24 1.00E-21 2.00E-22 6.23E-13 6.84E-18 U-234 8.00E-18 1.00E-15 2.00E-16 6.23E-07 6.84E-12 U-235 2.00E-16 4.00E-14

!3.00E-15 1.56E-05 1.71E-10 U-236 9.00E-17 2.00E-14 3.00E-15 7.79E-06 8.55E-11 U-238 3.00E-15 7.00E-13 1.00E-13 2.87E-04 3.16E-09 Stack: U02 Building - Labs (K58)

Average Flow Rate: 7.58 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!,!Ci/ml}

{!,!Ci/ml}

{!,!Ci/ml}

il!.9.1

{mrem}

Gross alpha 4.00E-16 3.00E-15 6.00E-17 4.09E-02 NA Gross beta 3.00E-15 1.00E-14 2.00E-16 3.79E-01 NA U-232 7.00E-25 7.00E-24 1.00E-25 8.18E-11 7.B0E-16 U-234 7.00E-19 7.00E-18 1.00E-19 8.18E-05 7.60E-10 U-235 2.00E-17 2.o'OE-16 3.00E-18 2.04E-03 1.90E-08 U-236 9.00E-18 9.00E-17 2.00E-18 1.02E-03 9.50E-09 U-238 3.00E-16 3.00E-15 6.00E-17 3.77E-02 3.51E-07

USN RC Document Control Desk YRS:22:005 August 31, 2022 Page 7 I.

Gaseous Effluents (Continuously Sampled Stacks)

Reporting Period: January 1 - June 30, 2022 Stack: SF Building - NAF Furnace (K60)

Average Flow Rate: 4.55 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

ll!9.l

,{mrem}

Gross alpha 5.00E-16 5.00E-15 1.00E-16 3.38E-02 NA Gross beta 6.00E-15 2.00E-14 3.00E-16 4.29E-01 NA U-232 1.00E-24 1.00E-23 2.00E-25 6.77E-11 6.42E-16 U-234 1.00E-18 1.00E-17 2.00E-19 6.77E-05 6.42E-10 I

U-235 2.00E-17 3.00E-16 5.00E-18 1.69E-03 1.61E-08 I

U-236 1.00E-17 1.00E-16 3.00E-18 8.46E-04 8.03E-09 U-238 5.00E-16 5.00E-15 9.00E-17 3.12E-02 2.96E-07 I -

Stack:

  • Dry Conversion Facility (K62)

Average Flow Rate: 23.17 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

ll!9.l

{mrem}

Gross alpha 6.00E-16 3.00E-15 2.00E-17 2.0?E-01 NA Gross beta 3.00E-15 6.00E-15 6.00E-17 9.54E-01 NA U-232 1.00E-24 5.00E-24 4.00E-26 4.15E-10 4.38E-15 U-234 1.00E-18 5.00E-18 4.00E-20 4.15E-04 4.38E-09 U-235 3.00E-17 1.00E-16 1.00E-18 1.04E-02 1.10E-07 U-236 1.00E-17 6.00E-17 5.00E-19 5.19E-03 5.48E-08 U-238 5.00E-16 2.00E-15 2.00E-17 1.91 E-01 2.02E-06 Stack: BDU Facility (K65)

Average Flow Rate: 0.97 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{l,iCi/ml}

ll!9.l

{mrem}

Gross alpha 4.00E-16 1.00E-14 5.00E-16 7.00E-03 NA Gross beta 2.00E-15 2.00E-14 1.00E-15 2.82E-02 NA U-232 9.00E-25 2.00E-23 1.00E-24 1.40E-11 1.76E-16 U-234 9.00E-19 2.00E-17 1.00E-18 1.40E-05 1.76E-10 U-235 2.00E-17 6.00E-16 2.00E-17 3.50E-04 4.39E-09 U-236 1.00E-17 3.00E-16 1.00E-17 1.75E-04 2.20E-09 U-238 4.00E-16 1.00E-14 4.00E-16 6.46E-03 8.10E-08

USNRC Document Control Desk YRS:22:005 August 31, 2022 Page 8 I.

Gaseous Effluents (Continuously Sampled Stacks}

Reporting Period: January 1 - June 30, 2022 Stack: Cylinder Recertification Facility (K67}

Average Flow Rate: 0.44 cubic meters/second Unc~rtainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

11!9.l

{mrem}

Gross alpha 2.00E-16 1.00E-14 1.00E-15 1.53E-03 NA Gross beta 3.00E-15 4.00E-14 3.00E-15 1.79E-02 NA U-232 4.00E-25 2.00E-23 2.00E-24 3.05E-12 1.24E-16 U-234 4.00E-19 2.00E-17 2.00E-18 3.05E-06 1.24E-10 U-235 1.00E-17 6.00E-16 5.00E-17 7.64E-05 3.11E-09 U-236 5.00E-18 3.00E-16 3.00E-17 3.82E-05 1.55E-09 U-238 2.00E-16 1.00E-14 1.00E-15 1.41 E-03 5.73E-08 Stack: MERF Building (K69}

Average Flow Rate: 1.79 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

11!9.l

{mrem}

Gross alpha 8.00E-16 1.00E-14 3.00E-16 2.41E-02 NA Gross beta 7.00E-15 3.00E-14 8.00E-16 1.95E-01 NA U-232 2.00E-24 2.00E-23 5.00E-25 4.82E-11 1.54E-15 U-234 2.00E-18 2.00E-17 5.00E-19 4.82E-05 1.54E-09 U-235 4.00E-17 6.00E-16 1.00E-17 1.20E-03 3.86E-08 U-236 2.00E-17 3.00E-16 6.00E-18 6.02E-04 1.93E-08 U-238 8.00E-16 1.00E-14 2.00E-16 2.22E-02 7.12E-07 Stack: UO2 Building - BLEU Facility (K72}

Average Flow Rate: 14.08 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{!:!Ci/ml}

{!:!Ci/ml}

{!:!Ci/ml}

11!9.l

{mrem}

Gross alpha 2.00E-15 6.00E-15 3.00E-17 3.75E-01 NA Gross beta 6.00E-15 1.00E-14 1.00E-16 1.33E+00 NA U-232 3.00E-24 1.00E-23 7.00E-26 7.50E-10 4.24E-15 U-234

'3.00E-18 1.00E-17 7.00E-20 7*.50E-04 4.24E-09 U-235 8.00E-17 3.00E-16 2.00E-18 1.87E-02 1.06E-07 U-236 4.00E-17 1.00E-16 8.00E-19 9.37E-03 5.30E-08 U-238 2.00E-15 5.00E-15 3.00E-17 3.46E-01 1.96E-06

USNRC Document.Control Desk YRS:22:005 August 31, 2022 Page 9 I.

Gaseous Effluents (Continuously Sampled Stacks)

Reporting Period: January 1 - June 30; 2022 Stack: UNB Building (K75)

Average Flow Rate: 0.47 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{l:!Ci/ml}

{l:!Ci/ml}

{l:!Ci/ml}

11!9.1

{mrem}

Gross alpha 3.00E-16 1.00E-14 1.00E-15 2.56E-03 NA Gross beta 1.00E-15 3.00E-14 3.00E-15 1.00E-02 NA U-232 7.00E-25 3.00E-23 2.00E-24 5.12E-12 5.54E-17 U-234 7.00E-19 3.00E-17 2.00E-18 5.12E-06 5.54E-11 U-235 2.00E-17 7.00E-16 5.00E-17 1.28E-04 1.39E-09 U-236 8.00E-18 4.00E-16 3.00E-17 6.40E-05 6.93E-10 U-238 3.00E-16 1.00E-14 9.00E-16 2.36E-03 2.56E-08 Stack: SURF Building (K77)

Average Flow Rate: 13.97 cubic meters/second Uncertainty Quantity Estimated Concentration Estimate MDC Released Exposure Radionuclide

{l:!Ci/ml}

{l:!Ci/ml}

{l:!Ci/ml}

11!9.1

{mrem}

Gross alpha 6.00E-16 3.00E-15 3.00E-17 1.35E-01 NA Gross beta 5.00E-15 1.00E-14 1.00E-16 1.10E+00 NA U-232 1.00E-24 7.00E-24 7.00E-26 2.70E-10 1.38E-15 U-234 1.00E-18 7.00E-18 7.00E-20 2.70E-04 1.38E-09 U-235 3.00E-17 2.00E-16 2.00E-18 6.76E-03 3.45E-08 U-236 2.00E-17 9.00E-17 8.00E-19 3.38E-03 1.73E-08 U-238 6.00E-16 6.00E-15 3.00E-17 1.25E-01 6.37E-07 Summary Tabulation for All Stacks Grand Total (all stacks) 1.49E-05 mrem

USNRC Document Control Desk August 31, 2022 II.

Liquid Effluent Reporting Period: January 1 - June 30, 2022 Concentration Constituent

(µCi/ml}

Soluble U

  • 1.04E-07 Insoluble U**

3.42E-08 Tc-99 2.00E-06 Total Ci Total Volume LLD

(µCi/ml)

Combined liquid effluent released to City of Richland sewer system.

Quantit¥ (Ci}

0.0068 0.0022 0.1300 0.1390 The average concentration of insoluble uranium for the 6-month period was 13.2 ppb.

YRS:22:005 Page 10 Liquid Volume (m3}'

6.51E+04 These constituents are analyzed chemically via Inductively Coupled Plasma/Mass Spectroscopy (ICP/MS) as opposed to radiation counting. Laboratory detection limits for uranium and Tc-99 are generally 1 ppb and 5 ppt, respectively