MONTHYEARML24026A2792024-01-31031 January 2024 Framatome - Richland Integrated Inspection Report 07001257/2023004 ML24031A5432024-01-23023 January 2024 Triennial Update to Decommissioning Funding Plan (DFP) for the Framatome Inc., Richland Nuclear Fuel Fabrication Facility Cover Letter ML23352A3912023-12-20020 December 2023 Framatome Inc. - Richland Material Control and Accounting Program Inspection Report 07001257-2023401-Public Cover Letter ML23313A0772023-11-27027 November 2023 Framatome Inc. - Request to Amend License and Approve Criticality Safety Methods - License Amendment 19 (Enterprise Project Identification Number L-2023-LLA-0073) ML23296A0072023-10-25025 October 2023 Framatome-Richland - Core Inspection Report 07001257/2023003 ML23291A2042023-10-18018 October 2023 Framatome Inc., Richland Nuclear Fuel Fabrication Facility'S Request to Amend License No. SNM-1227 and Approval of Criticality Safety Methods ML23255A2892023-09-15015 September 2023 Framatome-Richland Inspection Schedule for Calendar Year 2024 ML23254A2502023-09-13013 September 2023 Request of Additional Information Letter to Framatome ML23202A2022023-07-24024 July 2023 Framatome Richland Core Inspection Report 07001257/2023002 ML23198A3172023-07-17017 July 2023 Framatome Inc. Richland Nuclear Fuel Fabrication Facility'S Revised Chapter 1 of License No. SNM-1227 ML23144A3092023-06-21021 June 2023 Acceptance Letter for Request by Framatome for a License Amendment for an Approval of Criticality Safety Methods ML23144A3372023-06-12012 June 2023 Letter to Framatome Approval of Request to Withhold Proprietary Information ML23145A3082023-06-0202 June 2023 Framatome - Licensing Project Manager Change Letter ML23137A3962023-05-17017 May 2023 Framatome, Inc., Richland Nuclear Fuel Fabrication Facilitys Request to Amend License No. SNM-1227; and Approval of Criticality Safety Methods ML23137A4062023-05-17017 May 2023 Framatome, Inc., Submittal of NRC Form 327s Which Report the Results of Material Balance Accounting and Seid Calculations for the Period March 22, 2022 to March 20, 2023 ML23089A2592023-04-10010 April 2023 2023-001 Framatome-Richland - NRC Integrated Inspection Report 07001257/2023001 ML23089A2602023-03-30030 March 2023 Framatome, Inc. - 2023 Fee Increase for Fuel Cycle Licensees; License No. SNM-1227; Docket No. 70-1257 ML23054A2562023-02-23023 February 2023 60-Day Report to January 2, 2023, Incident Reported Under 10 CFR 70 Appendix a Concurrent Report (NRC Event No. 56292); Framatome Richland Facility; License No. SNWI-1227; Docket No. 70-1257 ML22336A0992023-02-0303 February 2023 Cover Letter - Framatome Proprietary Approval 3x Letter of Intent Submittals 11/21/2022 and 11/29/2022 ML23030B6172023-01-31031 January 2023 Framatome-Richland - Core Inspection Report 07001257/2022004 ML23025A3172023-01-25025 January 2023 Submittal of Integrated Safety Analysis (ISA) Summary Annual Update for Framatome Inc.'S (Framatome'S) Richland, Washington Fuel Fabrication Facility ML22341A1562022-12-0707 December 2022 60-day Follow Up Report for an Incident Reported Under 10 CFR 70 Appendix a (C) Concurrent Report (NRC Event No.56713); Framatome Richland Facility ML22272A0252022-10-0404 October 2022 Framatome-Richland -Integrated Inspection Report 07001257/2022003 ML22263A4652022-09-20020 September 2022 Framatome, Inc. Submittal of Revised Fundamental Nuclear Material Control Plan ML22255A0122022-08-31031 August 2022 Framatome Inc. - Required Reporting of Effluents Per 10 CFR 70.59 ML22238A1602022-08-24024 August 2022 Framatome Richland Facility Emergency Plan Version 16.0 ML22236A5872022-08-23023 August 2022 Framatome Inc., Richland Nuclear Fuel Fabrication Facility'S Intent to Amend License No. SNM-1227; ML22201A5352022-07-21021 July 2022 Framatome 2022-002 Integrated Quarterly Inspection Report ML22192A1272022-07-11011 July 2022 Framatome, Inc., 60-day Report for a May 12, 2022 Incident Reported Under 10 CFR 70 Appendix a 24-hour Report (NRC Event No. 55897) ML22154A4382022-07-11011 July 2022 Cover Letter - Framatome Inc. - Request to Amend License and Approve Criticality Safety Methods - License Amendment 18 (Enterprise Project Identification Number L-2021-LLA-0218) ML22187A1892022-06-29029 June 2022 Framatome-Richland - Inspection Schedule for Calendar Year 2023 ML22187A0392022-06-28028 June 2022 Framatome Documentation Request - 2022-003 PMT ML22137A1282022-06-23023 June 2022 Cover Letter - Framatome- DFP Info and Form 327 Proprietary Review ML22166A3432022-06-10010 June 2022 Framatome Lnc., Submittal of Quality Assurance Program, FS1-0011462, Revision 8.0, 10 CFR 71, Subpart H Quality Assurance Program Description for Packaging and Transportation of Radioactive Materials for Us Fuel ML22132A2292022-05-12012 May 2022 Framatome, Inc., Submittal of NRC Form 327 ML22132A2952022-05-12012 May 2022 Framatome, Inc., Submittal of Triennial Update to Decommissioning Funding Plan (DFP) for the Richland Nuclear Fuel Fabrication Facility ML22087A1212022-03-31031 March 2022 Cover Letter Framatome Inc., - Request for Additional Information Regarding License Amendment Request for Approval of Criticality Safety Methods (Enterprise Project Identification Number L-2021-LLA-0218) ML22059A7582022-03-0303 March 2022 Framatome, Inc., Licensee Performance Review (Nuclear Regulatory Commission Inspection Report 0701257/2022005) ML22060A1262022-03-0101 March 2022 60-day Report to January 4, 2022 Incident Reported Under 10 CFR 70 Appendix a Concurrent Report (NRC Event No. 55686); Framatome Richland Facility; License No. SNM-1227; Docket No. 70-1257 ML22066B2732022-02-28028 February 2022 Framatome, Inc. - Required Reporting of Effluents Per 10 CFR 70.59 for July-December 2021 ML22033A1722022-01-27027 January 2022 Framatome, Inc. Richland Washington Fuel Fabrication Facility Submittal of Update to Integrated Safety Analysis (ISA) ML22025A3902022-01-25025 January 2022 60-day Report to January 4, 2022 Incident Reported Under 10 CFR 70 Appendix a Concurrent Report (NRC Event No. 55686); Framatome Richland Facility ML22024A2152022-01-25025 January 2022 Framatome, Inc. - Richland, U.S. Nuclear Regulatory Commission Integrated Inspection Report 07001257/2021004 ML22024A4832022-01-24024 January 2022 60-Day Report to December 20, 2021 Incident Concurrently Reported Per 10 CFR 70 Appendix A(C) (NRC Event No. 55666); Framatome Richland Facility ML22007A3592022-01-0707 January 2022 Framatome, Inc., 30-Day Report to December 8, 2021 Incident Reported Under 10 CFR 70.50(b)(3) (NRC Event No. 55634) ML21335A3282021-12-23023 December 2021 Response to Framatome Request of 11-1-21 for Withholding Due to Proprietary Information ML21336A7572021-12-0202 December 2021 Framatome, Inc., Richland Facility, 30-day Report to October 12, 2021 Incident Reported Under 10 CFR 70.50(b)(1) (NRC Event No. 55517) 2024-01-31
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML22187A0392022-06-28028 June 2022 Framatome Documentation Request - 2022-003 PMT ML21160A0182021-04-19019 April 2021 Framatome - NCS 1 and Transportation Document Request 2021-002 ML20253A1472020-09-14014 September 2020 Acceptance of Framatome Inc.'S Request for Exemption from 10 CFR 70.50(b)(1)and Request for Additional Information 2022-06-28
[Table view] |
Text
June 28, 2022 INSPECTION DOCUMENT REQUEST Licensee: Framatome Inc.
Facility: Framatome - Richland, WA Docket Number: 07001257 License Number: SNM-1227 Inspection Report 2022-003 Number:
Enterprise Number: EPID: I-2022-003-0062 Inspection Dates: July 25- 29, 2022 Inspection IP 88072 - Plant Modifications (Triennial), Rev. 08/21/2018 Procedure(s):
Inspector(s): Lindsey Cooke (Team Leader)
P: 404-997-4836 Fuel Facility Inspector E: Lindsey.Cooke@nrc.gov U.S. Nuclear Regulatory Commission (NRC)
Region-II Office Cynthia Taylor P: 404-997-4480 Sr. Fuel Facility Inspector E: Cynthia.Taylor@nrc.gov U.S. NRC Region-II Office Gregory Goff P: 404-997- 4744 Fuel Facility Inspector E: Gregory.Goff@nrc.gov U.S. NRC Region-II Office
Inspection Document Request for NRC Inspection at Framatome Inc.
INSPECTION PROCEDURE 88072 - PLANT MODIFICATONS (Triennial)
- 1. Information Requested for In-Office Preparation
- a. Engineering/Configuration Management organization chart
- b. List of system engineers and assigned systems for the UO2 building focusing on recovery and powder (systems 130 through 360)
- a. Conversion of UO2 pellets to U3O8 powder system 130
- b. Miscellaneous uranium recovery system 140
- c. UO2 pellet dissolution system 190
- d. NFI NI-IX inner powder containers filling, storage, and on plant movement system 335
- e. UO2 powder download operation system 322
- f. Powder drum warehouse system 350
- g. Lube blend press feed system 360
- c. An index/list of Plant modifications (PM) program-related procedures including post-mod testing
- d. The focus of the inspection will be on mods completed in the UO2 building focusing on recovery and powder (systems 130 through 360) between startup until 2022. Please provide a list of mods in the area that covers the time from facility startup until 2022.
NOTE: Please provide this list ASAP so that we can provide you with the specific mods that will be requested for on-site review. IF this list too extensive, you may limit the list to significant modifications including ones that impacted the ISA or safety bases.
- e. List of current outstanding design issues (including open/deferred or canceled engineering action items), temporary modifications, and operator workarounds for the UO2 process focusing on powder and recovery
- f. List of active corrective maintenance work requests/orders for the UO2 building focusing on recovery and powder (systems 130 through 360)
- 2. Information Requested for On-site Review
- a. Provide the following documents for the UO2 building focusing on recovery and powder (systems 130 through 360):
- a. Piping and Instrument diagrams
- b. Electrical single line diagrams
- c. Process Hazards Analysis (PHA)
- d. System descriptions
- e. Operations procedures
- f. ISA Summary (various revisions upon request)
- b. List of condition reports for last 12 months (or since the last inspection) pertaining to PM/engineering program activities for the identified systems 130 through 360.
- c. List of open condition reports associated with the UO2 building focusing on powder and recovery Miscellaneous Requests
- 1. Request for a tour of the UO2 building following the entrance meeting 2
- 2. Meeting with the UO2 engineer and appropriate personnel to discuss major changes (physical and ISA related) to UO2 since commissioning (including ECR numbers)
- 3. Provide NRC access to the Framatome REDS system
- 4. Request licensing provide NRC inspectors brief tutorial on how to navigate the REDS system, schedule meeting via TEAMS prior to arrival on site.
This letter contains voluntary (mandatory) information collections that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). The Office of Management and Budget (OMB) approved these information collections (approval number 3150-0009). The burden to the public for these information collections is estimated to average one hour(s) per response. Send comments regarding this information collection to the FOIA, Library and Information Collection Branch, Office of the Chief Information Officer, Mail Stop: T6-A10M, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by email to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0009) OMB, Washington, DC 20503.
3