Enclosure 3 - NAPS Draft SER Section 3 Comments
ML21312A011
Person / Time
Site: North Anna  
(NPF-004, NPF-007)
Issue date: 11/04/2021
From:
Dominion Energy Co, Virginia Power (Virginia Electric & Power Co)
To:
Office of Nuclear Reactor Regulation
James L, NRR/DNRL/NLRP, 301-415-3306
Shared Package
ML21312A000 List:
References
EPID L-2020-SLR-0000
Download: ML21312A011 (2)


Text

Section #

Page #

Comment Generic Comment Number 1

3.0.3.2.11 3-66 The last sentence of the 2nd paragraph in the Staff Evaluation should refer to one exception and two enhancements instead of five exceptions and enhancements.

Generic Comment 5 2

3.0.3.2.11 3-66, 3-67 The staffs evaluation of Enhancements 1 and 4 should be updated to identify that the enhancements have been completed and deleted from Section B2.1.18 and Table A4.0-1, Item 18 as identified in Supplement 1 dated February 4, 2021 (ML21035A303).

There should only be two remaining enhancements.

Generic Comment 6 3

3.0.3.2.11 3-68 3.0.3.2.11 UFSAR Supplement discussion - The 2nd sentence should be revised as follows:

The staff also noted that Dominion Energy committed to ongoing implementation of the existing Fuel Oil Chemistry Program for managing the effects of aging for applicable components during the subsequent period of extended operation implement the program and begin inspections 10 years prior to the subsequent period of extended operation, and to complete inspections to be completed prior to the subsequent period of extended operation at least 6 months prior to the subsequent period of extended operation or no later than the last refueling outage prior to the subsequent period of extended operation.

Generic Comment 7 4

3.0.3.2.12 3-68 Staff evaluation identifies only four enhancements instead of five enhancements. Also, Enhancement 1 should be split into 2 separate enhancements to agree with the SLRA and Table A4.0-1, Item 23.

Generic Comment 5 5

3.0.3.2.17 3-86 The last sentence of the in the 2nd paragraph in the Staff Evaluation should refer to three enhancements instead of four enhancements.

Generic Comment 5 6

3.0.3.2.17 3-87 The staffs evaluation of Enhancement 4 should be updated to identify that the enhancement has been completed and deleted from Section B2.1.18 and Table A4.0-1, Item 18 as identified in Supplement 1 dated February 4, 2021 (ML21035A303). There should only be three remaining enhancements.

Generic Comment 6 SER text revision comments show deletions in bold strikethrough.

SER text revision comments show additions in bold underline.

Dominion Comments on the Draft North Anna SLRA SER Section 3 Text

Section #

Page #

Comment Generic Comment Number SER text revision comments show deletions in bold strikethrough.

SER text revision comments show additions in bold underline.

Dominion Comments on the Draft North Anna SLRA SER Section 3 Text 7

3.0.3.2.19 3-91 to 3-94 UFSAR Supplement. SLRA Section A1.35 provides the UFSAR supplement for the Inspection of Water-Control Structures Associated with Nuclear Power Plants AMP. The staff reviewed this UFSAR supplement description of the program and noted that it is consistent with the recommended description in GALL-SLR Report Table XI-01. The staff also noted that Dominion Energy committed (Commitment No. 35) to ongoing implementation of the existing Inspection of Water-Control Structures Associated with Nuclear Power Plants AMP for managing the effects of aging for applicable components during the subsequent period of extended operation implementing the program enhancements 6 months prior to the subsequent period of extended operation. The staff finds that the information in the UFSAR supplement is an adequate summary description of the program.

Generic Comment 7 8

3.0.3.2.9 3-59 Enhancement 5 should be deleted (pdf pg 185) (deleted in supplement 3) and what is enhancement 6 should be renumbered to 5. Enhancement 7 should be deleted (it became enhancement 5 which was deleted). Enhancement 8 should be deleted - it was completed in Supplement 2.

Generic Comment 6 9

3.0.3.2.22 3-99 to 3-100 Supplement 1, dated February 4, 2021, deleted Enhancements 2 through 7 from B2.1.39 (XI.E3A) and Table A4.0-1, Item 39, since these were completed prior to Supplement 1 being issued. This supplement is not referenced for this AMP.

Generic Comment 6