3 to Updated Final Safety Analysis Report, Drawing 5I721-2440-06, Logic Diagram Emergency Equipment Cooling Water System Valves Div. I Auto Open
ML21055A278
Person / Time
Site: Fermi, 07200071  DTE Energy icon.png
Issue date: 02/02/2021
From:
DTE Electric Company
To:
Office of Nuclear Reactor Regulation, Office of Nuclear Material Safety and Safeguards
Shared Package
ML21055A091 List: ... further results
References
NRC-21-0002
Download: ML21055A278 (1)


Text

D C

B A

VLS CLOSE LIGHT CONTACT tel IX

,, G @

CLOSE OPEN P.B.

1x*

6 EB VLS OPEN LIGHT CONTACT CLOSE P.B.

EB 1_x.:---

GI

'XI R @

OPEN IL2X~* -----..----i:X

-G"' EB CLOSE TRANSFER SW.

CON'T RM I LOCAL 1B j OR t VLS OPENING BY-PASS CONTACT 5

OPENING TORQUE SW.

CONTACT VLVS.

OPENING LIMIT CONTACT iE7 rn ro, I OR}

MOTOR 0. L.

125%

'XJ ON (AC)

CLOSE FORWARD STARTER-OPEN VALVE OFF (O)

OPEN STARTER-STOP VALVE I AND!

,x*

ON AC)

CLOSE REVERSE STARTER-CLOSE VALVE OPEN P.8.

,..XI 1 OR COP LOCAL VALVE FEEDER PANEL ITEM NO.

PANEL H21P625 tDENT DIV CODE NO.

TAG NO.

MCC POS OPEN PB CLOSE PB OPEN PB CLOSE PB 13 EECW M. U. TANK A OUTLET I

P4400F602A VB-2407 72C-3A 7A 1A225 1A226 PB1-7A P82-7A

    • VALVE NO. FROM TABLE ON SYST. DIAG. M-5444 6

5 4

4 OPEN EEC\\,/

VALVES SEE I-2440-01 AREA B-2 D<.I I OR)

CLOSE P.B.

.x OR l CLOSING TORQUE SW.

CONTACT 3

VLS CLOSING BY-PASS CONTACT rx,

°Al I OR)

I AND E DCD'S INCORPORATED:

ECR-30844-1, REV, A ECR-30844-7, REV. D 2

1 E

)....-----,

VALVE LIMIT SWITCH CONTACT DEVELOPMENT l

VALVE VALVE IP4400F601Ar

  • P4400F603AJ CON-t-----'V_AL~V-E~P~O=S-IT=IO=N...._ __

--t FULL FUNCTION FULL CLOSE CONTACT I-2440-04 FULL CLOSE CONTACT I-2440-04 TACT A

B C

D CLOSED BY-PASS FOR J(

71 rn IJ THIS ORA WING W.AS REFORMATTED BY AUTOCAD AT REVISION "E". ALL PREVIOUS APPROVAL SIGNATURES ARE ON FILE ON MICROFILM IN DOCUMENT CONTROL TC A PORTION OF TlUS DRAWING IS AFFECTED BY THE FOLU)WING:

CHANGE DOCUMENT liiil E

F G

H SPARE CLOSE LIGHT OPENING LIMIT BY-Pi'SS FOR V SPARE OPEN LIGHT INTERLOCK~/~

MAKEUP M ~

X CLOSING TORQUE SW. INTERRUPTS CONTROL CIRCUIT IF 11\\ECH OVERLOAD OCCURS DURING CLOSING CYCLE Y

OPENING TORQUE SW. INTERRUPTS CONTROL CIRCUIT IF 11\\ECH OVERLOAD OCCURS DURING OPENING CYCLE.

j CONTACT OPEN -

CONTACT CLOSED LOCATION SYMBOLS:

C::. IN CONTROL ROOM

@ IN PUSHBOTTON AT CONTROLLED EQUIPMENT 0 AT M.C.C.

EB IN DEDICATED SHUTDOWN PANEL H21P625

[;ii AT VALVE P4400F601A LIMIT SWITCH iii! AT VAL VE P44DOF603A LIMIT SWITCH REFERENCE DWG'S & DOCUMENTS I-2070-01 I-2440-01 I-2441-21 M-5358 SD-2512-18 M-5444 M-2001 L GIS SYMBOLS AND LEGEND LOGIC DIAG. -

EEC\\./ & EESw' SYSTEMS SCHM DIAG. EEC\\JS VALVES -

AUTO PEN PIPING DIAG, -

RBCC'w' SYSTEM 480VAC MCC 72C-3A FRONTAL ELEV, PIPING DIAG. -

EEC\\../ SYSTEM DIV. I LEGEND OF SYMBOLS & INSTRUMENT IDENTIFICATION FDR PLANT SYSTEM DIAGRAMS I-2003-01, 02, 03 ARRANGEMENT OF EQUIP. ON PANEL H11P601 6M-2290, SHT, 2 I-2440-05 STANDARD PANEL CONFIGURATION EMERGENCY EQUIPMENT CODLING \\../ATER SYSTEM

/

VAL VE -

AUTO PEN DIV, II LOGIC DIAGRAM C ~

I-2441-25 SCHEMATIC DIAGRAM -

EEC\\../ MAKEUP PUMP 1

~

_,..~----~---""..... ~P4~4~0~0SC0~0~2!;_A_,...,..,....-.................. ~~~~;;:~;---;::;--~

51721-2440-06 PREPARED BY CHECKED BY NOTES:

LATEST REVISION E

1. REFER TO EDISON STANDARD DWG 6M-2290, SH. 2 DETAIL 2 FOR EXPLANATION OF CONTROL PUSHBUTTONS, INC.CODE TITLE u

DATE DATE NUCLEAR SAFETY RELATED THIS IS AN AUTOCAD PRODUCED DRAWING.

CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED.

Detroit Edison Fermi 2 LOGIC DIAGRAM EMERGENCY EQUIPMENT COOLING WATER SYSTEM VALVES DIV. I AUTO OPEN OTHER REVISIONS:

APE TURE CARD TITLE CORRECTED PIS NUMBERS IN ZONES D-2/3. CHANGED L D EECWS VLVS DIV { AUTO OPEN P44F601A 8. P44F603A TD P4400F601A 8. P4400F603A,--t-------1--==---=.----l-=~~~~~~~~~::'::':=::#--!_!___!__,£;~!.Y---r'~~=:;=::F---j RESPECTIVEL Y.

f----t-----------1----'"'"-'PP'-"R=OVE=D~BY"'---+---"'D"'ATce.E--1 PLANT IDENTIFICATION SYSTEM NUMBER ARMS RECIPIENT#

ADMINISTRATIVE CHANGES PER PEPS-0019 P44QQ PREPARED BY DATE c~~~hB,YYcr~

DATE DOCUMENT TYPE CODEDDDINC

c. M. Brzustew,cz 11/30/04
7,5JP'I OTHER APPROVALS DATE NUC OPS FILE NO.

DATE ISSUED TO IS 1801 EDP POSTING ENTRIES REQUIRE THE ADDITION OF THE ARMS STATUS CODE:

EITHER "AFC" OR "ASB" DRAWING NUMBER 51721-2440-06 REV.

E D

C B

A