MONTHYEARML20236N3451987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235V1161987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20238F7541987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20237H6861987-07-31031 July 1987 Monthly Operating Rept for Jul 1987 ML20235J3101987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML20215A3211987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20213G4341987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20206H4301987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20207R6091987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20211A1761987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20207M8271986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20211M0441986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20213F2231986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20207F6021986-09-30030 September 1986 Monthly Operating Rept for Sept 1986 ML20210C8931986-08-31031 August 1986 Monthly Operating Rept for Aug 1986 ML20212F5161986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20202G9981986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20211E1391986-05-31031 May 1986 Monthly Operating Rept for May 1986 ML20197D1581986-04-30030 April 1986 Monthly Operating Rept for Apr 1986 ML20203A5751986-03-31031 March 1986 Monthly Operating Rept for Mar 1986 ML20154M3421986-02-28028 February 1986 Monthly Operating Rept for Feb 1986 ML20214B7281986-01-31031 January 1986 Monthly Operating Rept for Jan 1986 ML20137C3581985-12-31031 December 1985 Monthly Operating Rept for Dec 1985 ML20138D5051985-11-30030 November 1985 Monthly Operating Rept for Nov 1985 ML20138R8561985-10-31031 October 1985 Monthly Operating Rept for Oct 1985 ML20138B6491985-09-30030 September 1985 Monthly Operating Rept for Sept 1985 ML20135G0591985-08-31031 August 1985 Monthly Operating Rept for Aug 1985 ML20133Q1701985-07-31031 July 1985 Monthly Operating Rept for Jul 1985 ML20132G1211985-06-30030 June 1985 Monthly Operating Rept for June 1985 ML20127A1101985-05-31031 May 1985 Monthly Operating Rept for May 1985 ML20127M0441985-04-30030 April 1985 Monthly Operating Rept for Apr 1985 ML20115H3501985-03-31031 March 1985 Monthly Operating Rept for Mar 1985 ML20099J4281985-02-28028 February 1985 Monthly Operating Rept for Feb 1985 ML20106G2981985-01-31031 January 1985 Monthly Operating Rept for Jan 1985 ML20112G9941984-12-31031 December 1984 Monthly Operating Rept for Dec 1984 ML20100Q2961984-11-30030 November 1984 Monthly Operating Rept for Nov 1984 ML20099B8981984-10-31031 October 1984 Monthly Operating Rept for Oct 1984 ML20097H9321984-08-31031 August 1984 Monthly Operating Rept for Aug 1984 ML20094N4261984-07-31031 July 1984 Monthly Operating Rept for Jul 1984 ML20093D0701984-06-30030 June 1984 Monthly Operating Rept for June 1984 ML20092G6171984-05-31031 May 1984 Monthly Operating Rept for May 1984 ML20084M4201984-04-30030 April 1984 Monthly Operating Rept for Apr 1984 ML20083K3761984-03-31031 March 1984 Monthly Operating Rept for Mar 1984 ML20087C7141984-02-29029 February 1984 Monthly Operating Rept for Feb 1984 ML20080H1031984-01-31031 January 1984 Monthly Operating Rept for Jan 1984 ML20083H9791983-12-31031 December 1983 Monthly Operating Rept for Dec 1983 ML20082R5131983-12-0101 December 1983 Monthly Operating Rept for Nov 1983 ML20081L2911983-11-0101 November 1983 Monthly Operating Rept for Oct 1983 ML20080R0711983-09-30030 September 1983 Monthly Operating Rept for Sept 1983 ML20077P0591983-09-0909 September 1983 Monthly Operating Rept for Aug 1983 1987-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20140E9181997-06-0707 June 1997 Safety Evaluation Supporting Amend 133 to License DPR-43 ML20115J3981996-07-22022 July 1996 Interim Part 21 Rept Re 3/4 Schedule 80 Pipe Furnished to Consolidated Power Supply.Investigation Revealed Only One Nuclear Customer Involved in Sale of Matl ML20126J5961992-12-31031 December 1992 Part 21 Rept Re Potential Loss of RHR Cooling During Nozzle Dam Removal.Nozzle Dams May Create Trapped Air Column Behind Cold Leg Nozzle Dam.Mod to Nozzle Dams Currently Underway. Ltrs to Affected Utils Encl ML20113H4871992-07-30030 July 1992 Part 21 Rept Re Surge Line Flooding Which May Occur When Large Pressurizer Vent Used to Support Reduced Rc Inventory Operations.Notification Received from Westinghouse on 920312.Item Not Reportable Per 10CFR21 ML20086U0311991-11-30030 November 1991 SG Tube Plugging Criteria for Outside Diameter Stress Corrosion Cracking (ODSCC) at Tube Support Plates ML20077K0831991-06-30030 June 1991 Nonproprietary Technical Justification for Eliminating Pressurizer Surge Line Rupture as Structural Design Basis for Kewaunee Nuclear Plant ML1118102861991-05-31031 May 1991 Handbook on Flaw Evaluation Kewaunee,Unit 1 Steam Generators Upper Shell to Cone Weld. ML20091E3441991-03-31031 March 1991 Nonproprietary Structural Evaluation of Kewaunee Pressurizer Surge Line,Considering Effects of Thermal Stratification ML20066B2101990-12-31031 December 1990 Generator Mid-Cycle Rept,Dec 1990 ML20062A4641990-09-30030 September 1990 Nonproprietary, Reevaluation of U-Bend Tube Fatique for Kewaunee Plant Steam Generators ML20042F3261990-05-0404 May 1990 LER 90-005-00:on 900404,intergranular Attack & IGSCC Results in Both Steam Generators a & B Being Categorized as C-3.All Defective Tubes Plugged & Sludge Lancing & Crevice Flushing conducted.W/900504 Ltr ML1117803551990-04-30030 April 1990 Generator Tubesheet Crevice Indications Return to Power Rept. ML20005G6831990-01-0505 January 1990 Part 21 Rept Re Installation Instructions for Grommet Use Range for Patel Conduit Seal P/N 841206.Conduit Seals in Environ Qualification Applications Inspected for Proper Wire Use Range & Grommets Replaced ML19354D8351989-11-0808 November 1989 Presentation to NRC Re Kewaunee (Wps) SECY-83-472 LOCA Analysis Effort. ML20247D3011989-07-12012 July 1989 Part 21 Rept 10CFR21-0047 Re Control Wiring Insulation of Inner Jacket Used on General Motors Diesel Generator Sets Identified as 999 or MP Series.Encl List of Owners of Units Notified ML20235J1941988-11-30030 November 1988 Analysis of Capsule P from Wisconsin Public Svc Corp Kewaunee Nuclear Plant Reactor Vessel Radiation Surveillance Program ML20207N4641988-10-12012 October 1988 Part 21 Rept Re Potential Problem W/Emd 20-645E4,Type 999 Excitation Sys Circuit Breaker & Wiring.Potential for Field Circuit Breaker to Trip Due to Combined Air Temps & Field Current Exists at All Plants W/Model 999 Sys ML20206E9801988-06-30030 June 1988 Rev 2 to Handbook on Flaw Evaluation,Kewaunee Unit 1 Steam Generators Upper Shell to Cone Weld ML20196G5251988-06-15015 June 1988 Technical Review Rept T809, Blocked Thimble Tubes/Stuck Incore Detector ML20154H0391988-04-30030 April 1988 Slide Presentation Matl,Nrc Meeting 880331,Kewaunee Nuclear Power Plant Steam Generator Tube Sleeve Installation ML20196G8881988-03-0303 March 1988 Headquarters Daily Rept for 880303 ML20147B2921987-12-31031 December 1987 Annual Operating Rept for 1987 ML20149J0261987-12-21021 December 1987 Part 21 Rept Re Installation of Relay Part B8002DN in Foxboro 62H Controllers in Facilities.Subj Relay Must Be Replaced by Relay Part N0196ZN.Relay B8002DN Not Used in Any Other Plants ML20236W7341987-11-30030 November 1987 Nonproprietary Kewaunee Steam Generator Sleeving Rept (Mechanical Sleeves) ML20236F3101987-10-31031 October 1987 Nonproprietary WCAP-11620, Addl Technical Bases for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Kewaunee ML20236N3451987-10-31031 October 1987 Monthly Operating Rept for Oct 1987 ML20235V1161987-09-30030 September 1987 Monthly Operating Rept for Sept 1987 ML20238F7541987-08-31031 August 1987 Monthly Operating Rept for Aug 1987 ML20237H6861987-07-31031 July 1987 Monthly Operating Rept for Jul 1987 ML20235J3101987-06-30030 June 1987 Monthly Operating Rept for June 1987 ML17261A5301987-06-18018 June 1987 Part 21 Rept Re Potential Util Failure to Comply W/Component Containment Isolation Licensing Commitment If Proposed Mods to Component Cooling Water Sys Instituted.Utils Advised to Evaluate Containment Isolation Sys ML20215A3211987-05-31031 May 1987 Monthly Operating Rept for May 1987 ML20215L8061987-04-30030 April 1987 Nonproprietary Rev 1 to Technical Bases for Eliminating Large Pipe Rupture as Structural Design Basis for Kewaunee ML20213G4341987-04-30030 April 1987 Monthly Operating Rept for Apr 1987 ML20206H4301987-03-31031 March 1987 Monthly Operating Rept for Mar 1987 ML20207R6091987-02-28028 February 1987 Monthly Operating Rept for Feb 1987 ML20211P7211987-02-23023 February 1987 Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly ML20211A1761987-01-31031 January 1987 Monthly Operating Rept for Jan 1987 ML20212B9451986-12-31031 December 1986 Reload Safety Evaluation,Kewaunee Cycle 13 ML20207M8271986-12-31031 December 1986 Monthly Operating Rept for Dec 1986 ML20212F4301986-12-31031 December 1986 Annual Operating Rept,1986 ML20212F6581986-12-31031 December 1986 Technical Review Rept, Degradation of Safety Sys Due to Component Misalignment &/Or Mispositioned Control/Selector Switches ML20212D9091986-12-23023 December 1986 Localized Rod Cluster Control Assembly (Rcca) Wear at PWR Plants, Engineering Evaluation Rept ML20211M0441986-11-30030 November 1986 Monthly Operating Rept for Nov 1986 ML20213F2231986-10-31031 October 1986 Monthly Operating Rept for Oct 1986 ML20207F6021986-09-30030 September 1986 Monthly Operating Rept for Sept 1986 ML20210C8931986-08-31031 August 1986 Monthly Operating Rept for Aug 1986 ML20212F5161986-07-31031 July 1986 Monthly Operating Rept for Jul 1986 ML20202G9981986-06-30030 June 1986 Monthly Operating Rept for June 1986 ML20211E1391986-05-31031 May 1986 Monthly Operating Rept for May 1986 1997-06-07
[Table view] |
Text
{{#Wiki_filter:**
'9 .
A VERAGE DAILY UNIT POW EB LEYEL DOCKET NO- 50-305 UNIT- KENAUNEE COMPLETED BY- G. H. RUITER TEIEPHONE- 414-388-2560 I225 BEPORT MONTH JANUARY, 1987 AVERAGE DAILY DAY POWER LEVEL (MBE-NET) 1 522 2 522 3 522 4 522 5 522 6 522 1 7 522 8 521 9 521 10 522 11 521 12 522 13 521 14 521 15 521 16 521 '
17 521 18 521 19 526 20 522 21 522 22 522 23 517 24 522 25 525 26 522 27 517 28 522 29 521 30 526 l
31 522 Dk kOOfK7 87013j R 05000305
-{ }}f
~ .
U N IT S HUTD0 W N S A N D PO V EB B EDUCTIO ES DOCKET NC: 50-305
- OBIT BARE: Kevasase DATE: Eebruary 2, 1987 COMPLETED BI: G. H. Beiter TELEPHONE: 414-388-2560 x225 REPORT MONTH - J ANU AEY, 1987 COMMENTS I NUMBER lSYS hCOMPONENT} I l 50. l DATE kTYPE "lD0 RATION lBEASONlMETHOElLER I :
l l + 1 -+ l f i I I I
i I I I I l No shutdowns or power reductions in January. I l
I I I I i i i I I I
I I I I I I I i I i 1 1 I I i I I i 1 1 1 1 I
I i i l i I I I t i 1 I I I I I I I e i 1 I i l I I I I I I I i I I I I I I i l 1 i 1 1
I 1
) 1 1 1 1 1 1 1 i i l I I I I l
) i I I I I I i i I I I I l
) I i I
) i I I I l i l I I I I i
} I i 1 1 i 1 I I I l i I I i
) 1 i I i I I i 1 l i 1 1 l i i l I i i i I 1 i I I i I I I i 1 1 1 I
I I I I I I i l i I I I I
I I I I i I I I I I I I I i 1 I l I I I i i l i i i I 1 l 1 I i I I i l I i l I l I I I I I I I I I I I i i I I i i I i i i l 1 l I I I i i i l i i i i i i I i i i i i 1 I l I I I I I I I i 1 i 1 1 1
l I I I I i 1 I i l 1 I I I i 1 1 I
1 I I I I I l 1 1 I I 1 i 1 1 i i 1
.l 1
. I.
. I. .
METHOD SYSTEM 6 COMPONENT CODES TYPE PEASON 1-Manual From NOREG-0161 F: Forced A-Pquipment Failure (Explain) 2-Manual Scras 5: Scheduled B-Maintenance or 1est 3-Automatic Scram C-Re f uel ing D-Regulatory Restriction 4-Continuations E-Operator Training G License Examination 5-Load Beductions F- Administrative 9-Other G-Operat ional Error (Explaint H-Other IExplaan)
OPE R AT I N C DATA REPOB T ;*
DOCEET W3- 50-305 COMPLETED BY- G. H. RUITER ,'
ST &TUS TELEPHONE- 414-388-2560 1225 0PER ATI NG 1 UNIT NANF KEMADNEE 2 BEPORTING PERIOD JANUARY, 1987
- NOTES
- e 3 LTCENSED THERM AL POWER (MWT) 1650
- Normal power operation continued *
- through this reporting period.
As of the end of this reporting period
- i 0 N A M E PL A TE RATING (GROSS nW E) 560 *
'
- the unit has 262 consecutive days 535
- of continuous operation.
5 DESIGN ELECTRICAL PATING (NET MWE)
- 6 hAIIMUM DEPEND ABLE C APACITY (GPOSS MWE) 529
- 7 MAXIMUM DEPE4D ADLE CAPACITY (NET MWE) 503 **********************************************
8 If CHANGES OCCUR IN CAPACITY RATINGS (ITIMS NUMBER 3 THROUGH 7) SINCE LAST REPORT, GIVE BRASONS None 4 9 P03ER LEVEL TO WHICH RES1DICTED, IF ANT (NET MWE) None 10 REASGNS FOR RESTRICTIONS, IF ANY THIS MONTH YR-TO-DATE CUMULATIVE 744 744 110713 11 HOURS IN REPORTING PERIOD 744.0 744.0 94345.3 12 NUMBER OF HOUPS REACTOR WAS CRITICAL 0.0 0.0 2330.5 13 REACTOR RESERVE SHUTDOWN HOURS 744.0 744.0 92814.7 14 HOURS GENERATOR ON-LINE 0.0 0.0 10.0 i 15 UNIT RESERVE SHUTDOWN HOURS 1215680 1215680 146029394 l 16 GROSS THERM AL ENERGY GENEPATED (MWH) 406200 406200 48188800 17 GIOSS ELECTRICAL ENERGY GENERATED (MWH) 388069 388069 45883955 18 NET ELECTRICAL FNERGY GENERATED (MWH) 19 UNIT SERVICE FACTOR 100.0 100.0 83.8 100.0 100.0 83.8 l 20 G IT AVAILABILITT FACTOR 103.7 10 3.7 80.2 21 UNIT CAPACITY FACTOR (USING MDC NET) 97.5 97.5 77.5
, 22 U%IT CAPACITY FACTOR (USING DER NET) 0.0 0.0 3.1 21 UNIT roRCED OUT AGF PATE 24 SHUTDOWN S SCHEDUIED OV ER NEIT 6 MONTHS (1YPE, DATE, AND DURATION Of EACH)
Refueling outage of 6-week duration is scheduled to start March 1, 1987.
- - - - - - .- -- a n- nenne, neston. PSTIM ATFD D ATE O F ST AR TUP - N/ A
DOCKET 50-305 KEW AUNEE NUCLEAR POWER PLANT
SUMMARY
OF OPERATING EXPERIENCE January, 1987 OPERATIONS: Reactor Coolant System boron concentration is less than 150 ppa; therefore, the turbine stop and governor valve test was not performed this month as allowed by Technical Specifications.
MAINTENANCE: Plant Mechanics replaced the 'B' Charging Pump block due to cracking and seals in 'A' charging Pump due to leakage. Also, replaced bearings in the 'A' Control Roon A/C unit and 'B' Turbine Building Fan coil Unit due to excessive vibration.
I S C did recalibration work on the 1B Boric Acid Tank Level Transmitter, Boric Acid Heat Tracing Circuit #1 and A pressurizer level histables.
Also, replaced a temperature indicator for the 1A Aux Feed Pump bearing.
Electricians installed thermocouples on the 1B Boric Acid Pump per a temporary change, replaced the Diesel Generator Differential Current Relays and performed several motor operated valve EC grease changes.
1 l
l l
1
- e. -
' ~
g NRC-87-15 WPSC(414] 433-1234 g f 3 TELEX 5101012698 WPSC GRB TELECOPIER[414] 433-1297 (.j EASYUNK 62891993 W M_M_ Y 600 North Adams
- P.O. Box 19002 + Green Bay, WI 54307-9002 February 10, 1987 10 CFR 50.36 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:
Docket 50-305 Operating License DPR-43 Kewaunee Nuclear Power Plant Monthly Operating Report The narrative "Sununary of Operating Experience" and completed forms covering plant and component availability for the Kewaunee Nuclear Power Plant for January 1987 are enclosed in accordance with Technical Specification 6.9.1(c).
Ver truly yours, M
D. C. Hintz Vice President - Nuclear Power DJM/jms Enc.
cc - US NRC - Region III Mr. Robert Nelson, NRC Sr Resident Inspector RR #1, Box 999, Kewaunee, WI 54216 INP0 Records Center, Suite 1500, 1100 Circle 75 Parkway, Atlanta, GA 30339 9 s\}}