Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML20140E918 | 7 June 1997 | Safety Evaluation Supporting Amend 133 to License DPR-43 | |
ML20115J398 | 22 July 1996 | Interim Part 21 Rept Re 3/4 Schedule 80 Pipe Furnished to Consolidated Power Supply.Investigation Revealed Only One Nuclear Customer Involved in Sale of Matl | |
ML20126J596 | 31 December 1992 | Part 21 Rept Re Potential Loss of RHR Cooling During Nozzle Dam Removal.Nozzle Dams May Create Trapped Air Column Behind Cold Leg Nozzle Dam.Mod to Nozzle Dams Currently Underway. Ltrs to Affected Utils Encl | Hydrostatic |
ML20113H487 | 30 July 1992 | Part 21 Rept Re Surge Line Flooding Which May Occur When Large Pressurizer Vent Used to Support Reduced Rc Inventory Operations.Notification Received from Westinghouse on 920312.Item Not Reportable Per 10CFR21 | |
ML20086U031 | 30 November 1991 | SG Tube Plugging Criteria for Outside Diameter Stress Corrosion Cracking (ODSCC) at Tube Support Plates | Hydrostatic Nondestructive Examination Earthquake |
ML20077K083 | 30 June 1991 | Nonproprietary Technical Justification for Eliminating Pressurizer Surge Line Rupture as Structural Design Basis for Kewaunee Nuclear Plant | Safe Shutdown Earthquake Pressure boundary leak |
ML111810286 | 31 May 1991 | Handbook on Flaw Evaluation Kewaunee,Unit 1 Steam Generators Upper Shell to Cone Weld. | Hydrostatic Nondestructive Examination Finite Element Analysis |
ML20091E344 | 31 March 1991 | Nonproprietary Structural Evaluation of Kewaunee Pressurizer Surge Line,Considering Effects of Thermal Stratification | |
ML20066B210 | 31 December 1990 | Generator Mid-Cycle Rept,Dec 1990 | Boric Acid |
ML20062A464 | 30 September 1990 | Nonproprietary, Reevaluation of U-Bend Tube Fatique for Kewaunee Plant Steam Generators | |
ML20042F326 | 4 May 1990 | LER 90-005-00:on 900404,intergranular Attack & IGSCC Results in Both Steam Generators a & B Being Categorized as C-3.All Defective Tubes Plugged & Sludge Lancing & Crevice Flushing conducted.W/900504 Ltr | Boric Acid |
ML111780355 | 30 April 1990 | Generator Tubesheet Crevice Indications Return to Power Rept. | Safe Shutdown Nondestructive Examination |
ML20005G683 | 5 January 1990 | Part 21 Rept Re Installation Instructions for Grommet Use Range for Patel Conduit Seal P/N 841206.Conduit Seals in Environ Qualification Applications Inspected for Proper Wire Use Range & Grommets Replaced | |
ML19354D835 | 8 November 1989 | Presentation to NRC Re Kewaunee (Wps) SECY-83-472 LOCA Analysis Effort. | |
ML20247D301 | 12 July 1989 | Part 21 Rept 10CFR21-0047 Re Control Wiring Insulation of Inner Jacket Used on General Motors Diesel Generator Sets Identified as 999 or MP Series.Encl List of Owners of Units Notified | |
ML20235J194 | 30 November 1988 | Analysis of Capsule P from Wisconsin Public Svc Corp Kewaunee Nuclear Plant Reactor Vessel Radiation Surveillance Program | |
ML20207N464 | 12 October 1988 | Part 21 Rept Re Potential Problem W/Emd 20-645E4,Type 999 Excitation Sys Circuit Breaker & Wiring.Potential for Field Circuit Breaker to Trip Due to Combined Air Temps & Field Current Exists at All Plants W/Model 999 Sys | |
ML20206E980 | 30 June 1988 | Rev 2 to Handbook on Flaw Evaluation,Kewaunee Unit 1 Steam Generators Upper Shell to Cone Weld | |
ML20196G525 | 15 June 1988 | Technical Review Rept T809, Blocked Thimble Tubes/Stuck Incore Detector | |
ML20154H039 | 30 April 1988 | Slide Presentation Matl,Nrc Meeting 880331,Kewaunee Nuclear Power Plant Steam Generator Tube Sleeve Installation | |
ML20196G888 | 3 March 1988 | Headquarters Daily Rept for 880303 | Half scram Systematic Assessment of Licensee Performance Liquid penetrant |
ML20147B292 | 31 December 1987 | Annual Operating Rept for 1987 | Safe Shutdown Boric Acid Grab sample Fuel cladding Biofouling Fire Protection Program |
ML20149J026 | 21 December 1987 | Part 21 Rept Re Installation of Relay Part B8002DN in Foxboro 62H Controllers in Facilities.Subj Relay Must Be Replaced by Relay Part N0196ZN.Relay B8002DN Not Used in Any Other Plants | |
ML20236W734 | 30 November 1987 | Nonproprietary Kewaunee Steam Generator Sleeving Rept (Mechanical Sleeves) | |
ML20236F310 | 31 October 1987 | Nonproprietary WCAP-11620, Addl Technical Bases for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Kewaunee | Safe Shutdown Earthquake |
ML20236N345 | 31 October 1987 | Monthly Operating Rept for Oct 1987 | Boric Acid |
ML20235V116 | 30 September 1987 | Monthly Operating Rept for Sept 1987 | Packing leak |
ML20238F754 | 31 August 1987 | Monthly Operating Rept for Aug 1987 | |
ML20237H686 | 31 July 1987 | Monthly Operating Rept for Jul 1987 | |
ML20235J310 | 30 June 1987 | Monthly Operating Rept for June 1987 | |
ML17261A530 | 18 June 1987 | Part 21 Rept Re Potential Util Failure to Comply W/Component Containment Isolation Licensing Commitment If Proposed Mods to Component Cooling Water Sys Instituted.Utils Advised to Evaluate Containment Isolation Sys | |
ML20215A321 | 31 May 1987 | Monthly Operating Rept for May 1987 | |
ML20215L806 | 30 April 1987 | Nonproprietary Rev 1 to Technical Bases for Eliminating Large Pipe Rupture as Structural Design Basis for Kewaunee | Safe Shutdown Earthquake Pressure boundary leak |
ML20213G434 | 30 April 1987 | Monthly Operating Rept for Apr 1987 | |
ML20206H430 | 31 March 1987 | Monthly Operating Rept for Mar 1987 | |
ML20207R609 | 28 February 1987 | Monthly Operating Rept for Feb 1987 | |
ML20211P721 | 23 February 1987 | Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly | |
ML20211A176 | 31 January 1987 | Monthly Operating Rept for Jan 1987 | |
ML20212B945 | 31 December 1986 | Reload Safety Evaluation,Kewaunee Cycle 13 | Shutdown Margin Fuel cladding Coast down |
ML20207M827 | 31 December 1986 | Monthly Operating Rept for Dec 1986 | Boric Acid |
ML20212F430 | 31 December 1986 | Annual Operating Rept,1986 | |
ML20212F658 | 31 December 1986 | Technical Review Rept, Degradation of Safety Sys Due to Component Misalignment &/Or Mispositioned Control/Selector Switches | Boric Acid Operator Manual Action |
ML20212D909 | 23 December 1986 | Localized Rod Cluster Control Assembly (Rcca) Wear at PWR Plants, Engineering Evaluation Rept | Shutdown Margin Flow Induced Vibration |
ML20211M044 | 30 November 1986 | Monthly Operating Rept for Nov 1986 | Boric Acid |
ML20213F223 | 31 October 1986 | Monthly Operating Rept for Oct 1986 | |
ML20207F602 | 30 September 1986 | Monthly Operating Rept for Sept 1986 | |
ML20210C893 | 31 August 1986 | Monthly Operating Rept for Aug 1986 | |
ML20212F516 | 31 July 1986 | Monthly Operating Rept for Jul 1986 | |
ML20202G998 | 30 June 1986 | Monthly Operating Rept for June 1986 | |
ML20211E139 | 31 May 1986 | Monthly Operating Rept for May 1986 |