ML20210P524

From kanterella
Jump to navigation Jump to search

Forwards Draft Evaluation of Confinement Environ Temps Following High Energy Line Breaks Proposed for Fort St Vrain Environ Qualification Program, Technical Evaluation Rept,In Response to Util 861212 & 19 Submittals
ML20210P524
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 01/29/1987
From: Heitner K
Office of Nuclear Reactor Regulation
To: Robert Williams
PUBLIC SERVICE CO. OF COLORADO
Shared Package
ML20210P526 List:
References
TAC-42527, NUDOCS 8702130407
Download: ML20210P524 (3)


Text

a January 29, 1987 I Docket No. 50-267 Mr. R. O. Williams, Jr.

Vice President, Nuclear Operations Public Service Company of Colorado P. O. Box 840 Denver, Colorado 80201-0840

Dear Mr. Williams:

SUBJECT:

TEMPERATURE PROFILES FOR EQUIPMENT QUALIFICATION AT FORT ST. VRAIN Enclosed is a draft Technical Evaluation Report (TER) concerning the revised temperature profiles submitted by your letters dated December 12 and 19,1986 (P-86664 and P-86673). It reflects work done by our contractor, Pacific Northwest Laboratory (PNL). This draft PNL TER is being provided to you solely for your information at this time.

Sincerely, original signed by Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page

< DISTRIBUTION:

iDocketElle.Ll JPartlow NRC PDR HThompson Local PDR ACRS (10)

PBSS Reading PNoonan FMiraglia KHeitner OGC-Bethesda 0 Lynch EJordan JCalvo BGrimes HBerkow

> PBSS N PS PEICSB /}N PB n KHeitner:cw OL n h JC11vo HB 01@/87 01/d/87 01/p 87 01hf /87 01/A/87

$[3g21gggg{ 73go 7

]

l:..:' *

[ 'o,, UNITED STATES P o NUCLEAR REGULATORY COMMISSION O ;E WASHINGTON, D. C. 20555 k.....,/ .

January 29, 1987 Docket No. 50-267 Mr. R. O. Williams, Jr.

Vice President, Nuclear Operations Public Service Company of Colorado P. O. Box 840 Denver, Colorado 80201-0840

Dear Mr. Williams:

SUBJECT:

TEMPERATURE PROFILES FOR EQUIPMENT QUALIFICATION AT FORT ST. VRAIN Enclosed.is a draft Technical Evaluation Report (TER) concerning the revised temperature profiles submitted by your letters dated December 12 and 19, 1986 (P-86664 and P-86673). It reflects work done by our contractor, Pacific Northwest Laboratory (PNL). This draft PNL TER is being provided to you solely for your infonnation at this time.

Sincerely, Kenneth L. Heitner, Project Manager

~- -

Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page

Mr. R. O. Will'iams Public Service Company of Colorado Fort St. Vrain cc:

Mr. D. W. Warembourg, Manager Albert J. Hazle, Director ,

Nuclear Engineering Division Radiation Control Division Public Service Company Department of Health of Colorado 4210 East lith Avenue P. O. Box 840 Denver, Colorado 80220 Denver, Colorado 80201 4

Mr. David Alberstein, 14/159A Mr. J. W. Gahm, Manager GA Technologies, Inc. Nuclear Production Division Post Office Box 85608 Public Service Company of Colorado San Diego, California 92138 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. P. F. Tomlinsoi.. Manager Public Service Company of Colorado Quality Assurance D Nision .

P. O. Box 840 Public Service Company of Colorado Denver, Colorado 80201 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Senior Resident Inspector U.S. Nuclear Regulatory Commission Mr. R. F. Walker P. 0. Box 840 Public Service Company of Colorado Platteville, Colorado 80651 Post Office Box 840 Denver, Colorado 92138 Lelley, Stansfield & 0'Donnell Public Service Company Building Commitment Control Program .

Room.900 Coordinator 550 15th Street Public Service Company of Colorado Denver, Colorado 80202 2420 W. 26th Ave. Suite 100-D Denver, Colorado 80211 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan. Plaza Drive, Suite.1000 , ..

Arlington, Texas 76011' Chairman, Board of County Commissioners of Weld County, Colorado

, Greeley, Colorado 80631 Regional Representative Radiation Programs Environmental Protection Agency 1 Denver Place 999 18th Street, Suite 1300 Denver, Colorado 80202-2413 l

l