Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ML20076E880 | 17 May 1983 | Xcel Energy Lee O | Responds to NRC 830413 Order Re Environ Qualification of safety-related Electrical Equipment,Per 10CFR50.49.Environ Qualification Records Audit Will Be Completed by 831231 | Other |
ML20080E109 | 15 August 1983 | Xcel Energy Brey H | Provides Followup to Util Re Environ Qualification of safety-related Electrical Equipment. Justification for Continued Operation W/Components Not Fully Qualified Provided | Other |
ML20079M106 | 9 January 1984 | Xcel Energy Brey H | Advises NRC Re Status of Three Commitments Made in Util Concerning Environ Qualification of safety-related Electrical Equipment.Valve Actuators Tested & Successfully Passed HELB Tests | Other |
ML20100G888 | 11 September 1984 | Xcel Energy Marquez S Dvorak K | Four-Minute Isolation of Postulated Steam Line Breaks at Fort St Vrain Nuclear Generating Station | Other |
ML20112G667 | 27 December 1984 | Xcel Energy Lee O | Informs of Efforts to Environmentally Qualify Certain post-accident Monitoring Equipment Per 10CFR50.49.Equipment Identified in Reg Guide 1.97 & Existing in Harsh Environ Will Be Qualified by 850331 | Other |
ML20108A212 | 4 February 1985 | Xcel Energy Lee O | Informs of Receipt of Generic Ltr 84-24 on 850121 & Request for Addl Info on Environ Qualification of Electrical Equipment on 850128.Responses to Both Ltrs Will Be Provided by 850328 | Request |
ML20100H212 | 25 March 1985 | Xcel Energy Lee O | Forwards Response to NRC 841227 Order Re Certification of Compliance w/10CFR50.49 (Generic Ltr 84-24).Util Previously Submitted Ltrs Re Environ Qualification of safety-related Equipment in Response to IE Bulletin 79-01B | Other |
ML20100G880 | 28 March 1985 | Xcel Energy Warembourg D | Forwards Addl Info Re Environ Qualification Program. Response to NRC 850128 Concerns & Summary of Completion Schedule for Outstanding Items Encl | Other |
ML20237L173 | 29 March 1985 | Office of Nuclear Reactor Regulation Heitner K | Notification of 850403 Meeting W/Util in Bethesda,Md to Discuss Equipment Qualification | Meeting |
ML20127J807 | 11 June 1985 | Xcel Energy Warembourg D | Maintains Util Position of Full Compliance w/10CFR50.49 in Response to Eh Johnson 850611 Inquiry Re Environ Qualifications of Electrical Equipment Important to Safety. Responses to Each Concern Presented in Encl | Other |
ML20237L155 | 25 June 1985 | Office of Nuclear Reactor Regulation Heitner K | Submits Daily Highlight.Notifies of 850702 Meeting W/Util in Bethesda,Md to Discuss State of Compliance of Plant W/ Equipment Qualification Rule 10CFR50.49 | Meeting |
ML20132B917 | 11 July 1985 | Xcel Energy Lee O | Discusses Resolution of Technical Issues of Aging & Operability Times Per 850702 Meeting Re Environ Qualification Program.Hold on Reactor Power to 15% Proposed as Initial Limitation | Meeting |
ML20132F072 | 19 July 1985 | Office of Nuclear Reactor Regulation | Safety Evaluation Documenting Deficiencies in Licensee Program for Environ Qualification of Electric Equipment Important to Safety.Licensee Response to Generic Ltr 84-24 Inadequate.However,Operation at 15% Power Authorized | Approval |
ML20132F023 | 19 July 1985 | Martin R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) | Forwards Safety Evaluation Re Environ Qualification of Electric Equipment Important to Safety & Authorizes Interim Operation in dry-out Mode at Max 15% of Rated Power,Based on Listed Conditions,Until Technical Review Completed | Approval |
ML20134M016 | 20 August 1985 | Xcel Energy Warembourg D | Submits Discussion of Technical Issues Re Environ Qualification Program Raised During Meetings W/Nrc.Aging & Operability Time Program Operator Response Time,Temp Profiles & Shutdown Cooling Paths & Equipment Evaluated | Meeting |
ML20135B301 | 30 August 1985 | Xcel Energy Warembourg D | Forwards Justification to Operate Facility at Reduced Power Level.Requests That NRC Provide Concurrence for Facility to Be Operated at 8% Power Level for Period of Time Not to Exceed 45 Days.Operation Does Not Pose Undue Safety Risk | Other |
ML20135D754 | 30 August 1985 | Xcel Energy Warembourg D | Advises That Rev of Emergency Procedures Committed to in Deferred to Coincide W/Final Environ Qualification Program Documentation.Procedure Revs at This Time Will Cause More Confusion than Clarity for Operators | Other |
ML20205C845 | 10 September 1985 | Xcel Energy Warembourg D | Forwards Info Supporting 850830 Request to Operate at 8% Power to Facilitate Core Dryout for 45 Days,Per 850826,0903 & 04 Telcons.Moisture Removal Needed to Maintain Conditions Prescribed in FSAR & Tech Specs | Other |
ML20205C481 | 11 September 1985 | Xcel Energy Warembourg D Warenbourg D | Provides Commitment That Operating Procedures & Operator Training Described in Providing Addl Info in Support of Request to Operate at Up to 8% Power Will Be Complete Prior to Withdrawal of Control Rods | Withdrawal |
ML20137S741 | 23 September 1985 | Xcel Energy Warembourg D | Forwards Addl Calculations,Clarifying Util Re Predicted Fuel/Pcrv Liner Temps Resulting from Design Basis Event from 8% Power & Subsequent Reactor Cooling Utilizing Liner Cooling Sys.Calculations Confirm Original Position | Other |
ML20137H372 | 26 November 1985 | Chilk S NRC OFFICE OF THE SECRETARY (SECY) | Memorandum & Order Granting Extension of 851130 Deadline for Environ Qualification of Electrical Equipment to 860531 & Approving Proposal to Allow Operation w/35% Reactor Power Limit During Interim.Served on 851127 | Other |
ML20151N721 | 27 December 1985 | Xcel Energy Walker R | Forwards Response to 851105 Request for Addl Info Needed to Determine If Environ Qualification Program Complies W/ Requirements of 10CFR50.49.Sys Description & Temp Profiles Used in Environ Qualification Program Also Encl | Request |
ML20141P181 | 29 January 1986 | INC. SARGENT & LUNDY | Rev 00 to Justification/Analysis:Environ Qualification of Square D Pressure & Temp Switches | Other |
ML20141M808 | 14 February 1986 | Berkow H Office of Nuclear Reactor Regulation | Advises That DBAs Re Permanent Loss of Forced Circulation & Rapid Depressurization of Reactor Vessel Must Be Addressed in Equipment Qualification Program.Util Cooperation W/Program Mods Confirmed During 851029 Meeting | Meeting |
ML20154K144 | 28 February 1986 | Xcel Energy Warembourg D | Forwards Addl Info Re Environ Qualification,Per 851105 Request.Encl Info for Three Line Break Scenarios in Reactor Bldg Will Allow Independent Verification of Temp Profiles Obtained from Ga Technologies Using Computer Programs | Other |
ML20142A044 | 12 March 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 860221 Onsite Meeting W/Util,Inel,D Benedetto Assoc,S&W,Tenera,Ned & NPD Re Equipment Qualification Program & Steam Line Rupture Detection & Isolation Sys | Meeting |
ML20141P177 | 14 March 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 860130 Meeting W/Util,Inel,Tenera & Sargent & Lundy Re Equipment Qualification (EQ) Program.List of Attendees,Test Profiles & Review of Sample EQ Package Encl | Meeting |
ML20205S259 | 10 April 1986 | Office of Nuclear Reactor Regulation Shemanski P | Summary of 860326 Site Meeting W/Util,Dibenedetto Assoc,Inc, Sandia & Sargent & Lundy Re Status of Qualifications of 10CFR50.49 Cables & Maint Records History Review.Viewgraphs & Attendees List Encl | Meeting |
ML20204A318 | 1 May 1986 | Xcel Energy Warembourg D | Provides Status Summary of Environ Qualification Program. Addl Details on Program Contained in 860501 Draft Environ Qualification Submittal.Major Equipment Replacements Listed | Draft Other |
ML20197G513 | 12 May 1986 | Xcel Energy Walker R | Requests Concurrence Re Inclusion of DBA in Environ Qualification Program Per Berkow .Util Will Not Environmentally Qualify Electric Equipment to Mitigate DBA-1 & DBA-2 Since Equipment Not Exposed to Harsh Environ | Other |
ML20198H456 | 27 May 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 860505 Meeting W/Util Re Status of Equipment Qualification Program.Considerable Work Remains Before Approval of Full Power Operation Can Be Granted.Staff Recommended Util Continue to Complete Program | Meeting |
ML20205S234 | 1 June 1986 | Office of Nuclear Reactor Regulation Hinson C | Summary of 860502 Meeting W/Util & Inel in Bethesda,Md Re Equipment Qualification Program Problem Areas.Attendees List & Supporting Documentation Encl | Meeting |
ML20206R624 | 20 June 1986 | Xcel Energy Warembourg D | Forwards Environ Qualification Submittal Re Activities to Assure Compliance w/10CFR50.49 & Incorporating Comments on Draft 860502 Submittal.Evaluations Will Be Available for Review Before Request for Release to Full Power | Draft Request |
ML20203B618 | 15 July 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 860613 Meeting W/Util in Bethesda,Md Re Status of Plant Equipment Qualification Program.List of Attendees, Environ Qualification of Plant Safe Shutdown Cable & Cable Qualification Binders Encl | Meeting |
ML20204H653 | 31 July 1986 | Xcel Energy Warembourg D | Responds to 860724 Request for Documentation Re Use of Thermal Lag Analysis in Environ Qualification of Electrical Equipment in Plant.Thermal Analysis Will Be Performed Per Rev 3 to CENPD-255-A | Request |
ML20206P597 | 15 August 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 860724 Meeting W/Util,Inel,Wyle Labs,Sargent & Lundy & Tenera in Bethesda,Md Re Util Draft Documentation to Justify Qualification of safety-related Cabling at Plant. List of Attendees Encl | |
ML20197C563 | 30 October 1986 | Office of Nuclear Reactor Regulation Heitner K | Forwards Draft FATE-86-117, Review of Convection Heat Transfer Coefficients Utilized in Fort St Vrain Main Steam Line Break Analyses, Technical Evaluation Rept (Ter).Ter Addresses Details Used in Temp Profile Calculations | Draft Approval |
IR 05000267/1986025 | 30 October 1986 | Chamberlain D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) Farrell R Jaudon J Michaud P | Insp Rept 50-267/86-25 on 860816-0930.Violations Noted: Failure to Follow Procedures,To Review Mod Control Procedures & to Sufficiently Document Design Verification | Request |
ML20197C598 | 31 October 1986 | Battelle Memorial Institute PACIFIC NORTHWEST NATION White M | Review of Convection Heat Transfer Coefficients Utilized in Fort St Vrain Main Steam Line Break Analyses, Technical Evaluation Rept | Other |
ML20214Q095 | 25 November 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 861027 Meeting W/Util to Discuss Schedule for Ie/Nrr Insp of Equipment Qualification Program.Attendance List & Viewgraphs Encl | Meeting |
ML20214U707 | 2 December 1986 | Office of Nuclear Reactor Regulation Heitner K | Summary of 861120 Meeting W/Util,Ornl,Ga Technologies & Eg&G Re Temp Profiles for Equipment Qualification.List of Attendees & Viewgraphs Encl | Meeting |
ML20215E408 | 12 December 1986 | Xcel Energy Warembourg D | Forwards Analyses of Three Steam Line Break Scenarios for Reactor Bldg & Three Scenarios for Turbine Bldg Using Convective Heat Transfer Coefficient of 1.0,per NRC 861120 Request | Other |
ML20215G100 | 19 December 1986 | Xcel Energy Warembourg D | Forwards Second Formal Submittal Re Turbine Bldg Temp Profiles Resulting from Steam Line Breaks,Per 861120 Request.Composite Temp Profile Curves Originally Submitted as Basis for Environ Qualification Program Appropriate | Other |
ML20207K470 | 31 December 1986 | Battelle Memorial Institute PACIFIC NORTHWEST NATION White M | Final Review of Convection Heat Transfer Coefficients Utilized in Fort St Vrain Main Steam Line Break Analysis, Technical Evaluation Rept | Other |
ML20207K402 | 2 January 1987 | Office of Nuclear Reactor Regulation Heitner K | Forwards Final FATE-86-117, Review of Convection Heat Transfer Coefficient Utilized in Fort St Vrain Main Steam Line Break Analysis, Technical Evaluation Rept,For Info | Approval |
ML20207Q443 | 16 January 1987 | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) Merschoff E | Confirms 870126-30 Equipment Qualification Insp,Per 870113 Meeting at Region IV Ofcs.Mgt Entrance Meeting Scheduled for 870126 at Site Visitors Ctr & Exit Meeting Tentatively Scheduled for 870130 at Plant Site | Meeting |
ML20210P524 | 29 January 1987 | Office of Nuclear Reactor Regulation Heitner K | Forwards Draft Evaluation of Confinement Environ Temps Following High Energy Line Breaks Proposed for Fort St Vrain Environ Qualification Program, Technical Evaluation Rept,In Response to Util 861212 & 19 Submittals | Draft Other |
ML20210P645 | 31 January 1987 | Battelle Memorial Institute PACIFIC NORTHWEST NATION White M Wheeler C | Draft Evaluation of Confinement Environ Temps Following High Energy Line Breaks Proposed for Fort St Vrain Environ Qualification Program, Technical Evaluation Rept | Draft Other |
ML20211P495 | 25 February 1987 | Xcel Energy Robert Williams | Informs of Present Status & Plans Re Completion of Environ Qualification Program,Per Open Items Identified During 870130 Site Insp.Program & Implementing Procedures to Assure Environ Qualification in Place.Status of Open Items Encl | Other |
ML20212J293 | 26 February 1987 | Office of Nuclear Reactor Regulation Heitner K | Forwards Amend 50 to License DPR-34 & Safety Evaluation. Amend Changes Tech Specs Re Steam Line Rupture Detection/ Isolation Sys | Approval |