4 2

KLD TR174D 3

EVACUATION PLAN UPDATE for Seabrook Station Seabrook, New Hampshire Procress Report No. 5 PRELIMINARY EDITION Prepared for a.

The Commonwealth of Massachusetts civil Defense Agency and Office of Emergency Preparedness by KLD Associates, Inc.

300 Broadway Hutington Station, NY 11746

/

l

.E February 18, 1986

'~":PDRs6oatroose 86o3o5 ADOCK 05000443 F

. r. --

pm s,

?)...

t

~

s,

KLD TR174D EVACUATION PLAN UPDATE for Seabrook Station Seabrook, New Hampshire Procress Recort No. 5 PRELIMINARY EDITION I

Prepared for The Commonwealth of Massachusetts Civil Defense Agency and Office of Emergency Preparedness by KLD Associates, Inc.

i !

300 Broadway Hutington Station, NY 11746 February 18, 1986

i 1

TABLE OF CONTENTS Pace INTRODUCTION 11 SCOPE-OF FIFTH PROGRESS REPORT 1

EVACUATION TIME ESTIMATES 2

LIST OF TABLES E2m Title Pace 12 Description of Evacuation Scenarios 1-10 3

25 Identification of the Seabrook Staging 4

Emergency Planning Areas (ERPA) 14 Towns Included Within ERPA 6

26 Estimated Times to Evacuate from within 2 Miles 7

of Seabrook Station after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios

?

27 Estimated Times to Evacuate from within 5 Miles 8

of Seabrook Station after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios E28 Estimated Times to Evacuate from within 10 Miles 9

of Seabrook Station after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios 29 Estimated Times to Evacuate from within the 10 Seabrook Station EPZ after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios 30 Estimated Time to Evacuate from within the 11 Indicated Region of the Seabrook Station EPZ after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios l

LIST OF FIGURES Egz Title Pace 28 Map of EPZ Delineating all Emergency Response 5

Planning Areas (ERPA) i k

i

k 6

3 1.

INTRODUCTION This is the fifth of a series of Progress Reports which document the activities performed, and the results obtained, in connection with a study to update the existing evacuation plan

~

for the Seabrook Station.

The practice of publishing progress reports for distribution departs, somewhat, from the conventional practice of completing the study before publishing a Final Report.

We have chosen this approach for the following reasons:

It is hoped that the early publication of these reports 1.

would prove of value to other planning groups.

2.

Hopefully, these reports will also stimulate responses from all involved public agencies, citizen planning committees and town officials.

3.

The timing of these progress report publications will enable us to review all such responses -- both constructive and critical -- prior to the completion of the study.

Any responses which are received in a timely manner and judged to contribute to the accuracy and/or reliability of the final study results, will be incorporated into the evacuation plan development, prior to the publication of the Final Report.

This approach is endorsed by the Massachusetts Civil Defense Agency (MCDA), which is sponsoring this activity.

It is assumed that the reader also has a copy of the prior progress report, since many references are made thereto.

Also, the section numbers of this report are a continuation of those of the prior report so that:

i I

o Continuity of text is preserved o

Reference by future Progress Reports to the earlier reports are clear and unambiguous.

e 11

18. SCOPE OF FIFTH PROGRESS REPORT This oreliminary report describes the activities undertaken since the publication of the fourth Progress Report.

Specifically, time estimates (ETE) were computed for a broad

' range of evacuation scenarios, for each of 9 regions within the Seabrook Station Emergency Planning Zones (EPZ).

These computations use the current estimates of employment, the computed trip generation time distributions and apply the recommended traffic management policies.

The traffic management policies have been reviewed by almost all the police chiefs of the communities within the EPZ.

Many of these policies, in fact, were suggested by these police chiefs; all of these suggestions are incorporated within the evacuation plan.

Detailed descriptions of these control policies will be published shortly.

This oreliminary edition is published so as to present the Evacuation Time Estimates (ETE) as soon as they were computed.

A final edition of this Progress Report, complete with all details (see Table 13) and with selected graphical representations (see Figures 20-27) will be published as soon as possible.

I 1

i

i

19. EVACUATION TIME ESTIMATES (ETE)

This section presents the current results of the computer analyses using the IDYNEV System.

These results cover:

Ten evacuation scenarios as described in Table 12.*

o Nine regions within the Seabrook Station EPZ, as defined o

in Table 25.

Each region consists of one or more Emergency Response Planning Areas (ERPA). These ERPA are shown on Figure 28*; the communities comprising each ERPA are listed in Table 14*.

These ETE for each Region-Scenario combination, are j

presented in Tables 26-30:

o Table 26 presents the ETE for the two-mile area about Seabrook Station.

o Table 27 presents the ETE for the five-mile area about Seabrook Station, o

Table 28 presents the ETE for the ten-mile area about Seabrook Station.

Table 29 presents the ETE for the entire Emergency o

Planning Zone (EPZ) of Seabrook Station.

Table 30 presents the ETE only for the regions ordered to o

evacuate.

For example, if it is determined that everyone within 5 miles of the Station should evacuate, then all communities within Region 5 (ERPA A, B, C,

D) will be t

ordered to evacuate.

The ETE of interest, then, are those within 5 miles of the Station -- the area between the five-mile, area and the EPZ boundary is outside the area of potential risk.

1 j

The values of ETE are obtained by interpolating from IDYNEV output, which are generated at 30-mir".te intervals, then rounding to the nearest 5 minutes.

Thus, the numerical precision of these values is within 10 minutes.

l i

  • These Tables and Figure are abstracted from Progress Report No.

2 and included herein for the reader's convenience.

i l

l 2

=

1 Table 12.

Description of Evacuation Scenarios 1-10 Scenario Season Day Time Wea ther Comments 1

Summer Weekend Mid-day Good Beach area population at capacity. Employees are at 70 pct. of mid-week in towns with beach areas, 40 pct.

in remaining towns. Tourists fill available seasonal and overnight facilities, with half of them at the beach areas.

2 Summer Weekend Mid-day Rain As above. Sudden rain occurs with beach population at capacity concurrent with accident at Seabrook Station.

Beach area and tourist popul' tion at 75 pet. of capacity.

3 Summer Mid-week Mid-day Good a

Employees are at 100 pct. of mid-week work force.

4 Summer Mid-week Mid-day Rain As above. Sudden rain occurs.

5 Off-Season Mid-week Mid-day Good Tourist population at 50 pet, of yearly capacity (i.e.

facilities which remain open the entire year). No beach area transients. Employees at 100 pet.

6 Off-season Mid-week Mid-day Rain As above, but for inclement (rain) weather, 7

Of f-Season Mid-week Mid-day Snow Oonditions the same as for Scenario 5 except that there is inclement weather (snow). Evacuees must clear driveways.

8 Off-Season Mid-week Evening Good Tourist population at 50 pct. of yearly capacity. No Weekend All day beach area transients. Employees at 25 pct. of mid-week, mid-day.

9 Off-Season Mid-week Evening Rain As above, but for inclement (rain) weather.

~

Weekend All day 10 Off-Season Mid-week Evening Snow As above, but for inclement (snow) weather. Evacuees Weekend All day must clear driveways,

Table 25.

Identification of the Seabrook Station Emergency Planning Areas (ERPA)

Recion Radius ERPA Desienation 1

EPZ bdry.

A-G Entire EPZ 2

EPZ bdry.

A, D, G North Region 2

3 EPZ bdry.

A, C,

F West Region 3

4 EPZ bdry.

A, B, E South Region 5

Five Miles A,

B, C,

D Entire Five-Mile Region 6

Five Miles A, D North Region 7

Five Miles A, C West Region 8

Five Miles A, B South Region 9-Two Miles A

Entire Two-Mile Region ll 4

~~-

~ ~.

125 l

s l

.s NEW k

g NEWFIELDS__

GREENg D 18 CgSTLE ORTSMOUTHg EFE

/

BORY

?

/

1A 1

,, 85 s

XETER STRATHAM #

1 J BRENTWOOD 95 RYE 125 51

^

h 11 NORT t

101C 8) 1010 111

_HAMPTON I

88

,e E' S T 101C Kl GSTONl KINGSTO tiAMPT HAMPTdA l

51 107 Sb

,,)

/

HAMPTO 1507,,

M%

H, J' NEWTON

\\

MASS, MESBURY SALISBURY 125 108 MERRIMA 11 0 b

w_

Di I

11 3 NEWBU

\\./%

WEST NEWBURY r#

NEWBURY gpg 69U i

Figure 28.

Map of EPZ Delineating all Emergency Response Planning Areas (ERPA) 5

Table 14.

Towns Included Within ERPA Towns comorisina Indicated ERPA ERPA A

Hampton Falls, Seabrook B

Amesbury, Salisbury C

Kensington, South Hampton D

Hampton, North Hampton E

Merrimac, Newbury, Newburyport, West Newbury F

Brentwood, East Kingston, Exeter, Kingston, Newfields, Newton G

Greenland, New Castle, Portsmouth, Rye, Stratham 6

4

Table 26.

Estimated Times to Evacuate from within 2 Miles of Seabrook Station after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios Region Scenario 1 2,

2 1

1 1

2 1

-2 1

5:50 5:25 4:50 5:50 5:50 4:50 4:50 5:50 4:50 2

7:35 7:35 6:15 3

5:40 4:35 4:35 56 5:40 4:35 4:35 5:40 4:35 4

7:25 7:25 6:05 5

4:30 3:25 3:35 4:30 4:30 3:35 3:35 4:30 3:35 6

5:50 5:50 4:15 7

6:40 6:40 5:15 8

3:30 3:30 3:30 3:30 3:30 3:30 3:30 3:30 3:30 9

4:10 4:10 3:35 10 5:15 5:15 4:30 7

Table 27.

Estimated Times to Evacuate from within 5 Miles 1

of Seabrook Station after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios Region Scenario 1

1 2

1 1

i 1

1 2

1 6:10 5:25 5:10 6:10 6:10 5:10 5:10 6:10 5:10 2

7:50 7:50 6:30 3

5:55 4:45 4:45 5:55 5:55 4:45 4:45 5:55 4:45 4

7:40 7:40 6:20 5

4:50 4:00 4:00 4:40 4:50 4:00 4:00 4:40 4:00 6

6:05 6:00 4:35 7

7:00 7:00 5:35 8

4:40 3:35 3:35 3:35 3:35 3:35 3:35 3:35 3:35 9

6:00 5:05 4:00 10 6:10 5:30 4:35 6

I 8

Table 28.

Estimated Times to Evacuate from within 10 Miles of Seabrook Station after the Order to Evacuate from the Indicated Regions, for,the Individual Evacuation Scenarios Region Scenario 1 2

1 1

1 1

1 1

1 l

1 6:15 5:50 5:10 6:10 6:10 5:15 5:10 6:10 5:10 I

j 2

8:40 7:55 6:40 3

6:05 5:55 4:50 6:00 6:05 4:50 4:50 6:00 4:50 4

7:45 7:45 6:25 5

5:10 5:05 4:00 5:10 5:05 4:00 4:00 4:45 4:00 4

6 7:00 6:40 4:40 t

7 7:05 7:00 5:40 4

3 8

4:40 4:10 3:40 3:40 3:40 3:35 3:40 3:40 3:40 9

6:05 5:10 4:00 10 6:20 6:00 4:40 l

1 I

t P

l 9

l Table 29.

Estimated Times to Evacuate from within the Seabrook Station EPZ after the Order to Evacuate-from the Indicated Regions, for the Individual Evacuation Scenarios Region Scenario 1 1

1 1

1 1

1 1

2 1

6:40 6:15 5:15 6:10 6:20 5:15 5:15 6:10 5:15 2

8:45 7:55 6:45 3

7:10 7:05 4:50 6:10 6:10 5:15 4:50 6:10 4:50 4

9:40 7:45 6:25 5

6:00 6:00 4:05 5:30 5:05 4:05 4:05 4:45 4:05 6

7:30 6:40 4:40 7

8:00 7:00 5:40 8

5:00 4:40 4:00 4:00 4:05 4:00 4:00 4:00 4:00 9

6:05 5:10 4:05 10 6:30 6:00 5:00 6

's 4

i 10

,---.-nn.-e e-

~-

-m-,s-,

Table 30.

Estimated Times to Evacuate from within the Indicated Region of the Seabrook Station EPZ after the Order to Evacuate from the Indicated Regions, for the Individual Evacuation Scenarios Region Scenario 1 1

1 1

1 1

1 1

1 1

6:40 6:15 5:15 6:10 6:10 5:10 5:10 6:10 4:50 2

8:45 7:50 6:15 3

7:10 7:05 4:50 6:10 5:55 4:45 4:45 5:55 4:35 4

9:40 7:40 6:05 5

6:00 6:00 4:05 5:30 4:50' 4:00 4:00 4:40 3:35 6

7:30 6:00 4:15 7

8:00 6:15 5:15 8

5:00 4:40 3:40 4:00 3:35 3:35 3:35 3:35 3:30 9

6:05 5:05 3:35 10 6:35 5:30 4:30 i

i 5

11 0

APPENDIX I (Rev. 1.5)

TRAFFIC MANAGEMENT AND CONTROL (Subject to Second Review by Police Chiefs) 4 O

Traffic Control Post No. A-HB-01 I

ERPA: A TOWN:

Hampton (Hampton Beach)

LOCATION:

!!ampton Beach State Park NODE:

7 Hampton State Light Beach Parking N

X o%

X@

o Bridge K

X l4g (p>

X x

Route 1A i

1 Hampton Beach State Park Parking hy:

I

^

> Movement facilitated rl Movement discouraged Traffic guide i

O Traffic cone

)( Traffic barricade i.

DESCRIPTION:

1.

Encourage all traffic to move north along Route 1A.

4 I

i MANPOWCR/ EQUIPMENT 1

traffic guido 3

traffic cones 5

barricades

d Traffic Control Post No. A-HB-02 ERPA: A TOWN:

Hampton (Hampton Beach) l LOCATION:

Ocean Blvd. (Route lA) & Church St.

NODE:

12 A

I l

3 Stores I

l I

l I

Lic ht I

N

[Moteld I

i l

i Church St.

i

,/

g U

k C CM'CO g

s i

g I

l 1

Route 1A I

I I

I I

I I

i l

I I

a s

Parking i

g:

Movement facilitated

r; Movement discouraged O Traffic guide O

Traffic cone i

)( Traffic barricade DESCRIPTION:

1.

Facilitate traffic turnir-g onto Church St.

2.

Divert southbound traffic onto Church St.

3.

Facilitate traffic moving north on Route lA.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

Traffic Control Post No. A-HB-03 TOWN:

Hampton (Hampton Beach)

LOCATION:

Highland' Ave., Church St., Brown Ave.

NODI {:

311 h

N Church St.

4 g

4 N

N@

/

Route 51 f

Highland Ave.

=

Light 1

0

[lO I

O Brown Ave.

l 1

m: -

>- Movement facilitated r i Movement discouraged O' Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

l '.

All eastbound traffic makes U-turn.

2.

Westbound traffic on Highland Ave. merges with westbound traffic on Church St.,

then onto Route 51.

MNPOWER/EOUIPMENT 2

traffic guidos 3

traffic cones

Traffic Control Post No. A-HF-01 ERPA: A TOWN:

Hampton Falls

^

LOCATION:

Route 1 & Route 88 NODE:

80

}\\

Lafayette Rd.

Route 1 N

Route 88 sd f

Shopping

~~ @

b Area 000 Ky Movement facilitated

==l Movement discouraged O Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate northbound traffic on Route 1.

2.

Discourage southbound traffic on Route 1.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones

Traffic Control Post No. A-SE-01 ERPA: A r

TOWN:

Seabrook

- LOCATION:

Route 1 & Main St.

NODE:

83

\\ \\ Main Street To Route 286 Light N

=

k

. - - - - - - - - - ~

l~

o s

Tom

/

Church I

Hall l;-l A

=

Light O

o Northbound Route 1 d

Ky:

=

Movement facilitated Ol Movement discouraged

@ Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate southbound traffic along Main St.

2.

Discourage southbound and northbound traffic along noute 1.

MANPOWER / EQUIPMENT 2

traffic guides 10 traffic cones

Traffic Control Post No. A-SE-02 ERPA: A TOWN:

Seabrook LOCATION:

Route 286 & Washington Street NODE:

85 A

Washington St.

N

'OOOX

=

O lOo Route 286 i

Light M:

>= Movement facilitated Dal Movement discouraged

@ Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate westbound traffic on Route 286.

2.

Discourage all eastbound traffic.

@NPOWER/ EQUIPMENT 2

traffic guides 6

traffic cones 2

traffic barricades

Traffic Control Post No. A-SE-03 ERPA: A TOWN:

Seabrook LOCATION:

New Zealand Rd. (Route 107) & Lafayette Rd. (Route 1)

! ODE:

82 N

Route 1 l

) [

N

'l Route 107 Occooo O

O OOO seabrook s

O station very O

Entrance Light o

o I _O d

i I

I1 Route 1 g:

> Movement facilitated

>l Movement discouraged O Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate traffic turning westbound onto Route 107.

2.

Discourage through traf fic on Route 1.

MANDOWER/ EQUIPMENT 2

traffic guides 19 traffic cones

O Traffic Control Post No. A-SE-04 ERPA: A j

TOWN:

Seabrook LOCATION:

New Zealand Rd. (Route 107) & I-95 Very NODE:

202 Light I-95

/

/

f i N

2

/

l/f~"

's

/

i

/

/

0 j

^

o._

A i

=

g

=

=

N O

Route 107 P;g

/

/

/

/

/

/

/

/

g:

/ Ax

>- Movement facilitated 8

IX g

= l Movement discouraged f

O Traffic guide f

O Traffic conc very 9

): Traffic barricade DESCRIPTION:

1.

Discourage traffic from getting off I-95.

2.

Discourage castbound traffic on Route 107 3.

Facilitate movement from Westbound Route 107 onto I-95.

MANPOWER /EOUIPMENT 4 traffic guides 8 traffic barricades 3 traffic cones

Traffic Control Post No. A-SE-05 ERPA: A TOWN:

Seabrook LOCATION: ' Route 1A - Hampton Town Line NODE:

4 Bridge to Hampton Beach

' N N

N f

Qa*L3to n

l "dbr o

i f i

s

~

XXX XXX Route 1A e

J s

/

\\

37 d

g:

>- Movement facilitated

= l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Route all traffic south along Route lA.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic barricados

Traffic Control Post No. A-SE-06 ERPA: A TOWN:

Seabrook tOCATION:

Ocean Blvd. (Route 1A) & Route 286 NODE:

.6 h

O,o N

Route 286 gyg O

0 o

I ~Sause w miee very Light O

I fU o

Ocean Blvd.

O O

O Route 1A O

O g:

>- Movement facilitated

=l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Phcilitate tra#fic Trm ont frcn southbomd bute M onto Wsthound toute 286. If westbound traffic on )bute 266 'wca.e= congested, then send traffic southbound on Ibute 1A. Nhen Poute 286 traffic moves away frcn intersection, revert to guiding traffic onto Route 286. Thus, the preferential movement is onto MA!JPOWER/ EQUIPMENT Ibute 286; however, keep traffic moving out of Seabrook Beach even if Routa 286 is mngested.

2 traffic guidos 2.

Northbound traffic on Route 1A is to be turned 16 traffic cones back to travel southbound on Poute 1A.

3 traffic barricades

Traffic Control Post No. B-AM-01 ERPA: B TOWN:

Amesbury LOCATION:

Amesbury Center:

Route 150, Water St. & Elm St.

NODE:

40 A

Route 150 o

yi@

O O

f Ab Ro $

?

i I

ut@' /

)

I y

Water St.

  1. @ St.

g

'l Light j

Route 150

.i i

g:

?

Movement facilitated

>l Movement discouraged O Traffic guide O Traffic cone

~

)( Traffic barricade DESCRIPTION:

1.

Discourage northbound traffic along Route 150.

2.

Facilitate movement around traffic circle toward evacuation routes.

MANPOWER / EQUIPMENT 2

traffic guides 4

traffic cones

Traffic Control Post No. B-AM-02 ERPA: B TOWN:

Amesbury

' LOCATION:

Macy St. & Hillside Ave. (Route 110 & Route 150)

NODE:

104 Hillside Ave.

(Route 150) gg o

O o

I Light

__f e

i

~<g

- To I-4 95 1

O o.

o*'

-u Macy St*

(Route 110) g:

Movement facilitated

Movement discouraged O

Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Discourage eastbound movement along Macy St.

and northbound movement along Hillside Ave.

2.

Facilitate southbound movement on Hillside Ave.

toward entry ramp onto I-495 westbound.

MANPOWER / EQUIPMENT 2

traffic guides 12 traffic cones

Traffic Control Post No. B-AM-03 ERPA: B TOWN:

Amesbury LOCATION:

I-495 & Hillside Ave.

NODE:

249 & 250

}\\

Hillside Ave.

yl 00o

~e N

.d l\\- N N

o

'o I-495 s

e I-495

's Light X

X

- h g>lA Hunt Rd.

I l p

Ligh~$,

f N

l OOO x

h q g:

x Movement facilitated Hillside Ave.

>l Movement discouraged Light Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage movements along Hillside Ave.

2.

Facilitate traffic movement onto westbound I-495.

3.

Discourage eastbound movement on I-495.

MANPOWElt/ EQUIPMENT l

3 traffic _ guides 7 barricades 9 traffic cones

Traffic Control Post No. B-AM-04 ERPA: B i

TOWN:

Amesbury LOCATION:

Macy St. & Main St.

NODE:

44 Main St.

N 00_O Macy St.

f M-4 Route 110 g

O A

o 000 O

Light 6,

M:

> Movement facilitated

>l Movement discouraged O

Traffic guide O

Traffic cone

)(

Traffic barricade DESCRIPTION:

1.

Facilitate westbound movement along Macy St.*(Route 110).

2.

Discourage eastbound movement on Route 110.

MANPOWER / EQUIPMENT 1

traffic guide 9

traffic cones

Traffic Control Post No. B-AM-05 ERPA: B TOWN:

.Amesbury 1.OCA' PION:

Market St. & Main St.

NODE:

38 A

Main St.

N OO Market St.

s O

lf Light I

Key:

Movement facilitated

l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate westbound movement along Market St.

2.

Discourage northbound movements on Main St. and eastbound movements on Market St.

MANPOWI:H/l:OUIPMUNT, 1

traffic guido 6

traffic cones

Traffic Control Post No. B-AM-06 ERPA: B TOWri:

Amosbury

,L_OCATION :

I-95 & Route 110 NODE:

253, 255 I l I-95

\\

x x x.,

If[l Route 110 k

g o,U 2

y_\\

From o o o o@ o o o c

-s

=

=

salisbu y

'1' Light x

h-- f N

^"

s I*'y t

g:

y p p

> Movement facilitated

'Very

>l Movement discouraged Light O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Discourage eastbound movement along Route 110 and northbound movement along I-95.

2.

Facilitate movement of traffic from Route 110 onto southbound I-95.

14AtJPOWCH/CQtlIPMENT 4

traffic guidos 11 traffic cones 12 ;; traffic barricades

Traffic Control Post No. B-AM-07 ERPA: B TOWN:

Amesbury LOCATION:

Route 110 & Elm St.

NODE:

45 Elm St.

N N

\\

Route 110 (Macy St.)

00O i

~

Light enna 000 Bestaurant Light 9

1 Motel Clark St.

g:

> Movement facilitated

> l Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.,

Facilitate eastbound movement along Route 110 to I-95 ramp.

2.

Discourage northbound movement along Elm Street.

MANPOWER / EQUIPMENT 1

traffic guide 9

traffic cones

= _ _ _ _ _ _ _ -.. -, _ _ _ - _ - _ - - _.. _. _ _ - _ _ -. - _ _ _ - _

Traffic Control Post No. B-AM-08 ERPA:

B-TOWN:

Amesbury LOCATION:

Interchange of Route 110 with I-495 NODE:

103, 248 I-495 u/

/

=

V.

Route 110

/

l I

l l N

l Ky:

>= Movement facilitated Or: Movement discouraged

@ Traffic guide

'O Traffic cone

)( Traffic barricade DESCRIPTION:, 1.

Facilitate traffic movements onto the entry ramo to I-495 southbound, from Route 110.

2.

Discourage through traffic movements along Route 110.

MANPOWER / EQUIPMENT 1

traffic guide 10 traffic cones

Traffic Control' Post No. B-AM-09 ERPA: B TOWN:

Amesbury

' LOCATION:

Intersection of South Hampton Rd. & Market St. (Route 150)

NODE:

41 O

4/

Light "g

  1. 4e

\\

N

,\\'

000 O

O O

O00 g:

=

McVement facilitated

=l Movement discouraged 0 Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate traffic movements onto South Hampton Road northbound.

2.

Discourage all movements onto Route 150.

MANPOWER / EQUIPMENT 1

traffic guide 9

traffic cones

i Traffic Control Post No. B-SA-01 ERPA: B TOWN:

Salisbury LOCATION:

Forest St. (Route 286) & Lafayette Rd. (Route 1)

NODE:

. 87 A

Route 1 N

Liquor Store N

000 OOOO Route 286 w

w

=

0 0

,O O

Route 1 g:

>- Movement facilitated M Movement discouraged O Traffic guide O

Traffic cone

><. Traffic barricade DESCRIPTION:

1.

Facilitate westbound movement along Route 286.

2.

Discourage northbound and eastbound movements.

MANPOWER /EOUIPMENT 1

traffic guide 10 traffic cones

Traffic Control Post No. B-SA-02 ERPA: B TOWN:

Salisbury LOCATION: Forest St. (Route 286), High St. & Main St.

NODE:

90 Connector to Northbound I-95 g

^ Locust St.

N O

ooo Main St.

+

\\

m 8t, e

so

_O 4

4

\\

%c O

Forest St.

N Route 286 High St.

or--

O 00

\\

E!!Z8

>> Movement facilitated

%g

'e

1 Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate traf fic moving along Route 286 from High St. to Main St. westbound.

2.

Discourage eastbound traffic on Route 286 and Main St.

MANPOWER / EQUIPMENT 3 traffic guidos 15 traffic cones

Traffic Control Post No. B-SA-03 ERPA: B TOWN:

Salisbury LOCATION:

Congress St., Locust St. & Main St.

NODE:

35 1-es Congress St.

hw W O

lm poute 286

'M 7 -- -F Ysr.:

l

> Movement facilitated

>l Movement discouraged O

Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate traffic entering 7-95 southbound ramp.

2.

Discourage castbound traf fi- :n Main St.

MTNPOWER/EQtlIPMENT 1

traffic guide 6

traffic cones

Traffic Control Post No. B-SA-04 ERPA: B TOWN:

Salisbury

. LOCATION:

Route 1A & North End Blvd.

NODis:

5 4

O Central Avenue Route 1A N

North End Blvd.

Route lA OOO coe

, ___=

~.

Very Light j

OOO ooo Town Police Railroad Avenue

' Parking Cable Station Lot Avenue g:

i

>- Movement facilitated

=l Movement discouraged Traffic' guide O

Traffic cone X

Traffic barricade DCSCRIPTION:

1.

Accommodate all westbound flow on Route lA.

2.

Discourage castbound and northbound movements.

MANPOWCR/COUIPMENT 2

traffic guides 12 traffic cones i

Traffic Control Post No. B-SA-05 ERPA: B TOWN:

Salisbury

.LCCATION:

Route 1A & Stato Beach Rd.

4 NODE:

3 O

Route 1A g

N 4

e O

O

- 0 0

O O

O O

O O

d State Beach Rd.

O O

O EP.Z8

> Movement facilitated

>l Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate vehicles turning west from State Beach Rd. and merging with through traffic on Route 1A.

2.

Discourage movement eastbound along Route 1A.

MANPOWER /EOUIPMENT 1

traffic guide 18 traffic conos

Traffic Control Post No. B-SA-06 ERPA: B TOWN:

Salisbury

- LOCATION:

Elm St. (Route 110), Bridge Rd., Pleasant St., Beach Rd. (Route 1A), Lafayette Rd. (Route 1) & School St.

NODE:

93 Route 110 to I-95

/

O N

Mudnock O

Road NO N

Route 1 y

O School St.

3, o

g, o

O N

o o\\

.d W

Route 1, lA y

.l M:

Pleasant St.

O,

> Movement facilitated Route 1A

>l Movement discouraged O

Traffic guide

\\

\\

O Traffic cone

)( Traffic barricado DESCRIPTION:

Split the traffic moving wast on Route 1A onto two lanes approaching the intersection.

The two lanes will move continuously onto Route 110.

All traffic moving south on Route 1 will be diverted westbound to Route 110.

Northbound traffic on Route 1 will be' routed to Route 110 via School Street.

MANPOWER / EQUIPMENT 5

traffic guidos 32 traffic cones 3

traffic barricades

Traffic Control Post No. B-SA-07 ERPA: B TOWN:

Salisbury LOCATION:

Elm Street (Route 110) & Mudnock Road near Crossroads Plaza NODE:

4

] N N

Cushing Street R ute 110 OOC

.U c

9

=

=

k Light l}

=

To I-95 f

Mudnock Road

\\ %J E.*Z 8

> Movement facilitated

.?, Movement discouraged O

Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage eastbound, movement along Route 110.

2.

Facilitate westbound movemost along Route 110.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones 3

traffic barricades

Traffic Control Post No. B-SA-08 ERPA: B TOWN:

Salisbury

' LOCATION: North of Bridge Crossing on Route 1 at Ferry Road NODE:

b\\

N OOC Ferry Road V

O O

o o

Light Route 1 i

To Bridge - south l

U to Newburyport j(ey,:

s Da-Movement facilitated mai Movement discouraged i

@ Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate southbound movements on Route 1.

2.

Discourage northbound movement on Route 1.

i I

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

Traffic Control Post No. B-SA-09 ERPA: B TOWN:

Salisbury LOCATION:

Ocean Blvd. (Route 1A) & Route 286 NODE:

6 h

0 1

Route 286

{

gyg 0*

O}

o Salisbury Town Guide c

very Light 0

I f Ocean Blvd.

o

.O O

O Route 1A O

O E.*Xt

> Movement facilitated

=l Movement discouraged O

Traffic guide O

Traffic cone X Traffic barricado DESCRIPTIOti: 1.

Facilitate traffic run nnt frcr1 routhbottnd lbute 1A onto Westhound leute 286.

If westbound traffic on 1bute 266 la_mes congested, then send traffic southbound on Ibute 1A. Nhen 'bute 286 traffic rnovos away frcm intersection, revert to guiding traffic onto Ibute 286. Thus, the preferential rrovement is onto QANPOWUft/CQUIPMENT Ibute 286; however, koop traffic rioving out of Scilbrook Dcach even if Ibute 286 is congested.

2 traffic guidos 2.

Northbound traffic on Route 1A is to be turned 16 traffic conen back to travel soutib mnd on Ibute IA.

3 traffic barricades

Traffic Control Post No. C-KE-01 ERPA: C TOWN:

Kensington LOCATION:

Route 108 & Route 150 NODE:

131 To Exeter d

k N

Store O

'O iO Route 150 U

9 Route 108 K*J.8 Movement facilitated Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate southbound traffic along Route 108.

2.

Discourage southbound movement along Route 150.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones

i Traffic Control Post No. C-KE-02 ERPA: C TOWN:

Kensington

~

LOCATION: Intersection of Route 84 and Route 150 NODE:

~4 3 i l N

J t

I Wild Pa!,ture Road Lig t

i S o ey ad Route 150 f

A

( N

\\ N Route 84 Amesbury Road oute 150 M8 Movement facilitated Crl Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:, 1.

Facilitate northbound traffic along Route 150.

2.

Discourage all other movements.

Permit south-

. bound traffic on Route 150 to continue south to avoid turbulence at this location.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

f Traffic Control Post No. C-KE-03 ERPA: C TOWN:

Kensington LOCATION:

Intersection of Route 150 and Route 107 N DE:

42 0

tt i

1 1 Route 150 f

l#

U o p

\\

f jv oute 107 Route 150 M:

> Movement facilitated r; Movement discouraged Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

,1.

Facilitate the movements of traffic onto westbound Route 107.

2.

Discourage all other movements.

Permit traffic travelling eastbound on Route 107 to move onto Route 150 northbound to avoid turbulence at the MANPOWER / EQUIPMENT intersection.

1 traffic guide 7

traffic cones

Traffic Control Post No. C-SH-01 ERPA: C TOWN:

South Hampton

LOCATION
Town Center at Route 107A and Hilldale Avenue NODE:

122

) \\

9 Route 107A A

=

o Light

\\oo o,

i f

l 7

f A

=

Light

'go o M dale Avenue ht F.D.

7bwn School Whitehall Hall Road M

Movement facilitated M Movement discouraged 9 Traffic guide O Traffic cone

)C Traffic barricade DESCRIPTION:, 1.

Facilitate westbound traffic novements along Route 107A and Hilldale Avenue.

2.

Discourage eastbound traffic along Route 107A and southbound traffic.

MANPOWER / EQUIPMENT 1

traffic guide 9

traffic cones

Traffic Control Post No. C-SH-02 ERPA: C TOWN:

South Hampton

' I,0 CATION :

Intersection of Route 107A and Chase Road N

NODE:

,123 N

South Road OOC Route 107A

_/

/

O g

Light U

Light Chase Road i

M:

> Movement facilitated

= ; Movement discouraged

@ Traffic guide O Traffic cone JC Traffic barricade DESCRIPTION:

,1.

Facilitate traffic movements westbound on Route 107A and southbound onto Chase Road.

2.

Discourage traffic movements eastbound on Route 107A and northbound onto South Road.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

Traffic Control Post No. D-HA-01 ERPA: D

' lWP!:

Hampton E

LO_ CATION: High St. (Route 101C) & Lafayotto Rd. (Routo 1)

NODC:

73 I I Light N

s Lafayette Rd. (Route 1) 5 0

Route 101C f

~

4 b I

)

O 1

e' IO Light r

}O O

Exeter Rd.

O High St.

O g

s l

1.?X*

l

> Movement facilitated

>l Movement discouraged

@ Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Allocato service to traffic moving west onto Exeter Rd. from Route 1 northbound and High St.

westbound.

2.

Discourage southbound or cantbound traf fic.

MANPOWCR/COUIPMCNT s

2. traffic guides l

6 traffic conos

Traffic Control Post No. D-HA-02 ERPA: D TOWN:

Hampton

. LOCATION:

Interchange of Route 51, Route 101C & I-95

/8

/

230,233,235,236,/

NODE:

237,238 I-95 l

d w

I (

N I

h

.d

/

I A. r..i uj Route { j /

~

.. ~%

0 s e.34oo N 000 i

b

- s O,

0,

,,,y......pr.~.... T.gjgg....,o,

.pr s,

N 1 s.

m I

=

Movement facilitated I-95

= ; Movement discouraged O Traffic guide

')*

O Traffic cone g

)( Traffic barricade Route 51 DESCRIPTION:

1.

Facilitate movements from Route 101C to Route 51 west 2.

Facilitate traf fic moving from Route 51 to I-95 north 3.

Facilitate traffic westbound on Route 51.

4.

Discourage traffic from exiting Route 51 onto Route 101C and from northbound I-95 onto Route 51.

MANPOWER / EQUIPMENT 5

traffic guides 16 traffic barricades 40 traffic cones

Traffic Control Post No. D-HA-03 ERPA: D TOWN:

Hampton LOCATION: Occan Blvd. (Route 1A) & liigh St. (Route 101C)

NO'D E :

14 KingsHighwayJ Route 101C N

Lig t

[ Restaurant l 19th St g

Yh-ight 1

ffee o

gyJ7.7.T & f 18th St.

k~

SL*.I. GEM,,

Route 1A

  1. ^ thing M

>- Movement facilitated

>l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate movements from Route 1A to westbound Route 101C and northbound 1A.

2.

Discourage southbound movement along Route 1A.

MAtlPOWCR/EQUIPMErlT 2

trkffic guido 3

traffic cones 2

traffic barricades A m_

Traffic Control Post No. D-HA-04 ERPA: D TOWN:

llampton LOCATION:

Ocean Divd. (Route 1A) & Winnacunnet Rd. (Route 101C)

NODC:

13 Winnacunnet Rd.

N

=

(Route 101E) ndos Stores I (

ytnas HiCM "Y Q.CY

\\

{

/

dW d

4

-***7 Route 1A Parking 7

g L

)

)

Ocean Blvd. (Route 1A)

E.!Z8

> Movement facilitated

=l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate northbound traffic along Route IA.

2.

Discourage southbound traffic; divert it west on Route 101E.

_MAf@OWCR/COUIPMENT 2

traffic guides 12 traffic cones

Traffic Control Post No. D-HA-05 ERPA: D TOWN:

Hampton

~ LOCATION:

Ocean Blvd. (Route 1A) & Highland Ave.

NODE:

10 P,arking v

i l

l j..

I i

1 1

I Lic hti

~ l l

N I

I I

Highland Ave.

=

9


g a

6cyeo l

Ashworth l

i Route 1A Motel I

g I

.~

I l

I I

I I

I 1

I 1

Parking nex:

O Movement facilitated Of Movement discouraged 9

Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Highland Ave, will be converted to a one-way westbound street.

Eastbound traffic will be diverted to Brown Ave.

MANPOWER / EQUIPMENT 2

tra'ffic guides 6

traffic cones

Traffic Control Post No. D-HA-06 ERPA: D

. TOWN:

Hampton LOCATION: Route 1A & Ashworth Ave.

NODE:

7 P

/

N 5

9 O

N'N s

s Route 1A MI p>

Movement facilitated

t Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Allocate service to vehicles turning north onto Route 1A.

2.

Discourage southbound traffic.

MANPOWER / EQUIPMENT 3

traffic guides 3

traffic conus

Traffic Control Post No. D-HA-07 ERPA: D TOWN:

llampton LdC'ATION:

Routes 1 & 51 NODC:

205,206,207 Light

/

<l)

N Xxx

//

Route 1 South r

Xl*

Light

=

x 0

f f

i N

"Y

' ye, O

4.t.

Route 1 North

(!)

d 58 Route 51

>- Movement facilitated

= 1 Movement discouraged

@ Traffic guide O

Traffic cone

)(

Traffic barricade DESCRIPTIOti:

1.

Facilitate northbound traffic on Route 1.

2.

Facilitate westbound traffic on Route 51.

3.

Discourage southbound traffic on Route 1.

4.

Discourage eastbound traffic on Route 51.

5.

Discourage merging of traffic streams.

MANPowcR/courPMcNT 5 traffic guidos 14 barricades

Traffic Control Post No. D-HA-08 ERPA: D TOWN:

Hampton OCATION:

Route 51 & Landing Rd.

NODE:

j k N

Light Landing Rd.

l Route 51 I

30009 e[

O Light

=l O

O

)

Light M:

1

> Movement facilitated

>l Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate westbound traffic along Route 51.

2.

Discourage eastbound traffic along Route 51.

MANPOWER /COUIPMENT 2 traffic guides 6

traffic cenes

Traffic Control Post No. D-HA-09 ERPA: D TOWN:

Hampton

~

LOCATION:

Intersection of Route 151 with Route 1 NODE:

71 d

N ll Lig lt J i tre i

Route 151-6oo Route 1 g:

> Movement facilitated l

>l Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate westbound traffic movement onto Route 151 and northbound movement on U.S.

Route 1.

2.

Discourage southbound traffic movement on Route 1.

MANPOWER / EQUIPMENT 1

traffic guide f

3 traffic cones

Traffic Control Post No. D-NH-01 ERPA: D TOWN:

North Hampton LOCATION:

Intersection of Route 1 and North Road NODE:

61 U.S. Route 1 North Road North Road 8

l I

o*

Li Ngh

} \\

o g

'N U.S. Route 1 M:

>= Movement facilitated y=l Movement discouraged O Traffic guide

'O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate northbound traffic movement on Route 1.

2.

Discourage southbound traffic movement on Route 1 and eastbound movement on North Road.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

Traffic Control Post No. D-NH-02 ERPA: D TOWN:

North Hampton.

' LOCATION:

Route 151 and Route 10lt

/

h NODE:

49 Y

N Route 151 s

-w

==

O T

- Light oute 101D f

k

/.-

i Route 101D g

M:

I

>- Movement facilitated

> ; Movement discouraged

\\

@ Traffic guide Route 151 O Traffic cone

>< Traffic barricade DESCRIPTION:

1.

Discourage southbound movement along Route 151 and all movements along Route 101D.

2.

Facilitate northbound movement along Route 151.

MANPOWER / EQUIPMENT 3

traffic guides 5

barricades 9

traffic cones

Traffic Control Post No. D-NH-03 ERPA: D TOWN:

North Hampton LOCATION:

Lafayette Rd. (Route 1) &

Route 101D NODE:

62 N

Light Route 1 Route 101D U

A e

2 Light d

gO O

O O

O m:

>- Movement facilitated

= I Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate northbound and westbcond through movements through the intersection.

2.

Discourage movements south and east.

MANa'OWER/ EQUIPMENT 1

traffic guide 6

traffic conos

Traffic Control Post No. E-ME-01 ERPA: E TOWN:

Merrimac LOCATION:

I-495 & Broad St.

NODE:

268 & 269

'\\

road St.

o g "/o \\..

O

=N pc Q. y('

N

..'\\

N

'/

\\

's I-495

,A I-495

\\ \\ (_,

A tiet w *b

\\\\\\

x.

\\.

y;-

O\\

/

\\~,/

O Y

\\

~ k([

\\&-

M:

.s

>- Movement facilitated Broad St.

=I Movement discouraged

\\

O' Traffic guide Light O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage eastbound movement along I-495 and northbound movement along Broad St.

2.

Facilitate movement from Broad St. onto westbound I-495.

MANPOWCR/EOUIPMENT 3 traffic guides 8 barricades 11 traffic cones

Traffic Control Post No. E-ME-02 ERPA: E TOWN:

Merrimac I.OCATION:

Church St. & Main St.

NODE:

107 O

Church St.

N Main St.

ooo1 Route 110 O

I I

Broad St.

K_ey,:

e 3>-

Movement facilitated Orl Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate all traffic movements onto southbound Broad St. toward entry ramp to I-495 westbound.

2.

Discourage eastbound movement along Main St. and northbound movement along Church St.

MANPOWER / EQUIP' MENT 2 traffic guides 6 traffic cones

Traffic Control Post No. E-NB-01 ERPA: 'E TOWN:

Newbury Plum Island Tpke & Old Point Rd./ Sunset Dr.

LOCATION:

NODE:

1 A

u Old Point Rd.

Plum Island Tpke.

=

0 Sunset Dr.

M:

3>-

Movement facilitated

t Movement discouraged

@ Traffic guide O

Traffic cone

)C Traffic barricade DESCRIPTION:

1.

Allocate service time to the three movements to provide a smooth continuous flow.

MANPOWER / EQUIPMENT 1

traffic guide

~

Traffic Control Post No. E-NB-02 ERPA: E

~

TOWN:

Newbury

. LOCATION:

Route lA, Parker St., Green St.,

Rolfe Lane & Hanover St.

NODE:

99, 86, 68 From Plum Island Rolfe Lane Route lA v*

4 N

Y o

1 0

Town

@00 g

g Light Route lA 8

Green Street

,s Newburyport,,*F From Hanover St.

Parker Street h-To Route 1 Key:

N

>>- Movement facilitated Orl Movement discouraged 0 Traffic guide

'O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage, northbound movement along Route 1A and Rolfe Lane.

2.

Facilitate southbound movement along Route lA.

3.

Facilitate southbound movement along Green St.

and Hanover St.

t MANPOWER / EQUIPMENT 3

traffic guides 12 traffic cones

Traffic Control Post No. E-NB-03 ERPA: E TOWN:

Newbury

} LOCATION:

Hanover Street, Middle Road, U.S. Route 1 NODE:

70 h

N U.S. Route 1 O

O uj/ O*o)bsoo O

25sm 0

Middle y

Hanover O O O

O Street Road O

{

,)

O O

'N o

g O O

O.

C) oJ y Oi IfO O

N O O g:

9 3>-

Movement facilitated

^

n=1 Movement discouraged

@ Traffic' guide O

Traffic cone t

)( Traffic barricade DESCRIPTION:

1.

Discourage northbound movement along Route 1.

2.

Facilitate southbound movement from Hanover St.

onto Route 1.

Maintain two lanes of traffic moving south on Route 1; these will merge downstream.

MANPOWER / EQUIPMENT 2

traffic guides 31 traffic cones

Traffic Control Post'No. E-NP-01 ERPA: E TOWN:

Newburyport

-LOCATION :

Intersection of Route 1, Parker St. & State St.

NODE:

97 N

.N Route 1 State Street Parker Street

/N o

O\\

v Jg

o o

I3 Light g

e ooo j

  • o N

l o@

\\

h O

go O

EeZ:

Light

>- Movement facilitated D-1 Movement discouraged O Traffic guide O Traffic cone U.S. Route 1

>< Traffic barricade DESCRIPTION:

1.

Discourage northbound movement along Route ~l and State Street.

2.

Facilitate southbound movements from Route 1, Parker St. and State St. onto Route 1.

MANPOWER / EQUIPMENT 5

traffic guides 19 traffic cones

. Traffic Control Post No. E-NP-02 ERPA: E TOW:3 :

Newburytiort

~

LOCATION:

I-95 & Storcy Ave. Interchanyc NODL::

258,259 I

I I

yl 1-95

~~~

X H

l N

' N s il I

' t o

CC JC, Storev Ave.

C Route 113 o -

\\

m Ligiit j'

~

~~

Y O

. c t

(b N

h f

j ji

- - - - > Movement facilitated Very

>1 Movement discouraged Light O Traffic guide O Traffic cor:o X Traffic barricado o

DCSCRIPTION:

1.

Facilitate all movements from Storey Ave. onto southbound 1-95 and southbound movement along I-95.

2.

Discourage all other movements.

MA!!!'8 JWl:lt/l:QU T l'Mi-:NT 4

t ra f f ic qu i alcu 18 t.raf f ic conon 4 laa r r i <*.nles:

l Traffic Control Post No. E-NP-03 ERPA: E l

TOWN:

Newburyport

. LOCATION: ' Intersection of Route 113 with Moseley Ave., Ferry Rd.,

Noble St. & Low St.

NODE:

79, 101

\\.

Ferry

\\

Moseley Ave.

\\

Road Noble g

Stree

\\

a ge.

A' igh St.

y

[

Route f

lA t.

\\

Low Street N

/ToI-95 L __

g:

>- Movement facilitated

=l Movement discouraged O Traffic guide O

Traffic cone

)<

Traffic barricade DESCRIPTION:

1.

Facilitate all movements to travel westbound on Route 113.

2.

Discourage all eastbound and northbound movements.

MANPOWER / EQUIPMENT 3

traffic guides 21 traffic cones

Traffic Control Post No. E-NP-04 ERPA: E TOWN:

Newburyport OCATION: liigh St. & Broad St.

NODE:

167

} \\

N Broad St.

High St.

O Toppans N

Route 113 Lane High School M:

>- Movement facilitated

&l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate westbound movement along High St.

MAtlPOWER/COUIPMUNT 1

traffic guide

~-

Traffic Control Post No. E-NP-05 ERPA: E TOWrJ :

Newburyport (OCATION:

Route 1 & Merrimac St.

NODE:

96 A

u.S.

p!

Route 1 r

~ L, V,

N Merrimac St.

9 XXXX

~

f i

g:

Light

>- Movement facilitated

>l Movement discouraged O Traffic guide Q Traffic conc X Traffic barricado DESCRIPTION:

1.

Discourage northbound movement along Route 1 and traffic along Merrimac St.

2.

Facilitato southbound movement along Route 1.

mat 4POwnn/courPMCNT 2

traffic guides 9

traffic conos 6 barricades

Traffic Control Post No. E-NP-06 ERPA: E TOWN:

Newburyport

~ LOCATION: Parker St., Graf Rd.,

Low St. & Mulligan Way Low Street NODE:

mfM ft A

i Graf Road N

Mulligan Way /

3 ei'

^"

gd Parker Street j

Parker Street r

/

Newbur rt l' *, M ewbury s

.I To I-95 Scotland Road j

/

i M:

>- Movement facilitated

?* ~ Movement discouraged O Traffic guide O Traffic cone i

)( Traffic barricade

~

DESCRIPTION:

1.

Discourage northbound movement along Parker St.

and Graf Rd. and eastbound hovement along Parker St. and Low St.

t 2.

Facilitate southbound movements onto Parker St.

(

toward Scotland Ave. and I-95.

MANPOWER / EQUIPMENT 2

traffic guides 12 traffic cones l

Traffic Control Post No. E-NP-07 ERPA: E TOWN:

Newburyport LOCATION: Water St., Plum Island Turnpike & Ocean Ave.

NODE:

100 0

N Water St.

/

/

o Plum Island Ocean Ave.

N Newburyport Rolfe Newbury Lane K_ey,:

e

>>- Movement facilitated

l Movement discouraged

@ Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage westbound movement along Water St. and eastbound movement along th6 P.I.T.

2.

Facilitate movements onto Ocean Ave. southbound.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

I

\\..

'mAFFIC CONTROL POST N0. E-WN-01 ERPA: E

'IOWN:

WEST N W IDCATION:

Route 113 at Newburyport Tmm Line NODE:

[.'...

... '.,.* Artichoke River Route 113 N

  • c Light e

Light;; s

-x y i........ q! ;

j....:..:

  • . '::
  • p

.i f:... :

West Newburg !!:':'.:..:.'..!:Newburyport

[......;i'.:;'.i:.

Legend

Movement f acilitated
  • Movement discouraged

@ Traf fic guide O Traf fic cone x Traf fic barricades l

DESCRIPTION:

1.

Facilitate traffic covement in the directions indicated.

MANPOWER / EQUIPMENT:

1 - traffic guide 3 - traffic berricades l

e

TRAFFIC CONTROL POST NO.E-WN-02 TOWN:

WEST NEWBURY LOCATION:

Rouet 113 and Pentuckett School near Groveland Tom 1.ine NODE:

151 Pentucket School i

/

e e

x2,i Route 113 Legend

Movement facilitated 4 Movement discouraged

@ Traf fic guide O Traf fic cone u Traf fic barricades DESCRIPTION:

1.

Facilitate movements into/out of access road to the Pentuckett School and southbound along Route 113.

2.

Discourage northbound movements along Route 113.

MANPOWFR/ EQUIPMENT:

2 - traffic guides 3 - traffic cones 3 - traffic barricades

6.-

Traffic Control Post No. E-WN-0 3 ERPA: E TOWN:

West Newbury LCCATION:

South Street & I-95 Interchange & Scotland R:ai i

NODE:

262, 263 I

e.

I-95 N

i 4

iiG I

r a

I

\\ '.

xxbxx South St.

c-~~~*~'

~~='

oOM 9.g O

o

lO

[o00 C.

py s

G-I

'lo.

'tU y

k' E.er:

k.

2 I

h Movement facilitated l

  • I Movement discouraged j

O Traffic gu).de 7,igh t O

Traffic cone

,X Traffic barricade DESCRIPTION:

1.

Facilitate vehicles moving from South St. t:

I-95 southbound.

2.

Discourage northbound movement on I-95 and eastbound movement on South St.

l l

MANPOWER / EQUIPMENT l

3 traffic guides 9

traffic cones j

9 traffic barricades l

L

~ _ _

TRAFFIC CONTROL POST NO. E-W-04 ERPA: E

~

TOWN:

WEST NEWBURY LOCATION:

Georgetown Road and Crane Neck Road NODE:

Georgetown Road N \\

Light N% " -

N e

t s

x, Crane Neck Road x,,

b

,r Light Legend Movement facilitated

' Movement discouraged 8 Traffic guide O Traf fic cone x Traf fic barricades DESCRIPTION:

1.

Facilitate trovements onto Crane Neck Road, westbound 2.

Discourage northbound and eastbound traffic movements.

PM POWER /EQULPMENT:

1 - traffic guide 3 - traffic cones 6 - traffic barricades

i_

I.

IRAFFIC CONIROL POST NO. E-tC-05 ERPA: E TOWN:

WEST NEWBURY IDCATION: Bridge Street at Rock Village Bridge

')

NODE:

i i

I:!-

i1 i

V'

I.: (
i Haverhill 7:.

,s West Newbury

\\;;

\\

q..

' \\. y

\\

w kYa

!f Bridge Street

!i Merrimac River

, Legend Movement f acilitated l

' Movement discouraged i

@ Traf fic guide j

i O Traffic cone 4

x Traf fic barricades f

DESCRIPTION:

1.

Facilitate traffic to West Newbury for Merrirac parents traveling to pick up. children.

k 2.

Discourage all other through cove:nents.

MANPOWER / EQUIPMENT:

i 1 - traffic guide 3 - traffic cones 3 - traffic barricades

l Traffic Control Post No. F-BR-01 ERPA: F' TOWN:

Brentwood LOCATION: Route 125 & Route lllA NODE:

193 d

Route 125 N

Light Route lllA O

Light j

Key,

? Movement facilitated

=l Movement discouraged O

Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate movement along Route 125 northbound and Route lllA westbound.

2.

Discourage movement onto Route 111A eastbound.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones

Traffic Control Post No. F-BR-02 ERPA: F TOWN:

Brentwo5d LOCATION:

Intersection of South Road and Route 125 NODE:

183 N

N I

2:

To Route 107 South Road

-l C, m

y'? l o

Light o

000 k

Route 125 Mr pm-Movement facilitated l

2 l Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade

  • '~

DESCRIPTION:

1.

Facilitate traffic moving westbound on South Road or northbound on Route 125.

2.

Discourage eastbound traffic novement on South Road or southbound on P.oute 125.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones e

M

Traffic Control Post No. F-BR-03 ERPA: F TOWN:

Brentwood

- -LOCATION:

Intersection of Route 125 and North Road NODE:

i l a

Ligh b,

1 Or i North Road Route 125 M:

>- Movement facilitated

>l Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate northbound traffic movement along Route 125.

2.

Discourage all other traffic movements.

MANPOWER / EQUIPMENT

'l traffic guide 6

traffic cones

~

Traffic Control Post No. F-EK-01 ERPA: F TOWN:

East Kingston

- LOCATION: Intersection of Route 108 & Route 107 at Monahan Corner NODE:

128 N

Route 108 N

Route 107 Route 107/108 000h U

Light South Rd.

Kg:

Movement facilitated rt Movement discouraged O Traffic guide O. Traffic cone

)<

Traffic barricade DESCRIPTION:

1.

Facilitate westbound traffic on Route 107.

2.

Facilitate southbound traffic on Route 108 and traffic turning west onto Route 107/108.

3.

. Discourage movements eastbound on Route 107 and northbound on Route 108.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

}

Traffic Control Post No. F-EK-02 ERDA : F TOWN:

East Kingston LOCATION:

Intersection of Routes 107, 107/108 and 108 (west)

NbDE:

165 Route 107 gs___

Route 107/108 Light e

b b

  • h g

Route 108 N

g:

D>-

Movement facilitated

Movement discouraged

@ Traffic guide O Traffic cone

)( Traffic barricade

~

DESCRIPTION:

1.

Facilitate westbound traffic movement on Route 107 and southbound movement on Route 108.

2.

Discourage eastbound traffic movenent on Routes 107/108.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones O

Traffic Control Post No. F-EK-03 ERPA: F TOWN:

' East Kingston LOCATION:

Intersection of Route 107A and Route 108 NODE:

164 h

l Route 108 N

t

/

N Y

Light ooc Route 107A ig g

I f tigh :

Ky:

\\ -

't

-> Movement facilitated

- M Movement discouraged

@ Traffic guide O Traffic cone

)C Traffic barricade DESCRIPTION:

.l. Facilitate through neverents of traffic westbound on Ibute 107A ard southbound on !bute 108.

I

2. Discourage eastbound and northbound traffic revements.,
3. Discourage turning moverents frun westbound !bute 107A and l

southbound Ibute 108.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones 1

Traffic Control Post No. F-EX-01 ERPA: F TOWN:

Exeter LOCATION:

Interchange of Routes 111, 111A & 108 NODE:

133, 134, 140 ll Route 108

\\>@h O

Route 101C o

l s l

)

9 e

Route lilA e

n

==l Light N

Light Route 111 Route 108 I

Key:

Movement facilitated hal Movement discouraged 1

0 Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate traffic moving west on Route 111A.

2.

Discourage traffic moving east on Route 101C.

3.

Facilitate northbound traffic on Route 108 north of Exeter and southbound on Routes 111 and 108 south of Exeter.

MANPOWCR/ EQUIPMENT 2

tra f fic guides i,'

3 traffic cones i

'e

1

]

Traffic Control Post No. F-EX-02 ERPA: F TOWN:

Exoter

. LOCATION:

Route 101 & Epping Rd.

NODE:

137 A

Watson.

N Rd.

101 N,Ny 4

99

/

~

N N

X N

Light -

X

_g L

k Epping Rd.

g:

>- Movement facilitated

>l Movement discouraged

@ Traffic guide O Traffic conc

)( Traffic barricade DESCRIPTION:

1.

Discourage castbound movement along Route 101.

2.

Facilitate merging traffic moving west along Route 101.

MANPOWER /EOUIPMENT 1

traffic guido 5

barricados

Tra'ffic Control Post No. F-EX-03 ERPA: F TOWN:

Exeter

-LOCATION:

Exeter-Hampton Expressway & Route 85 NODE:

218, 219 8

i Route 85 j\\

/

i l

N Exeter M-y

~

A

~%

1

'7 I

I Lighp i

i N A +#

(

Key:

I

>- Movement facilitated

>-1 Movement discouraged O Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Discourage traffic from getting on/off the expressway.

2.

Facilitate northbound traffic along Route 85.

MANPOWER /EOUIt' MENT 1

traffic guide 4

barricades l

Traffic Control Post No. F-EX-04 ERPA: P l

TOWN:

Exetor LOCATION: Exeter-Hampton Expressway & Exetcr Rd. Interchange NODE:

47, 211, 212 h

Exeter Rd.

(Route 101D)

N g

'O z

s e

L1

~~~

  • x Truck

++

/

C/

\\

E ute S1

/

+

/

5

/

Light o

% U m ton pg, n

O g:

> Movement facilitated

>l Movement discouraged O Traffic guide O Traffic cone X Traffic barricade DESCRIPTION:

1.

Discourage westbound traffic from getting off the expressway.

2.

Force eastbound traffic off the expressway onto Exeter Road.

MANDOW11R/EOUIPML:NT 3 traffic guidos 7 barricades 6

traffic c>nes

Traf fic Control Post No. F-EX-0 5 ERPA: F TOWN:

Exeter I.OCATION:

Intersection of Route lllA & Epping.Rd.

_N O D E :

136 h

Epping Rd.

N Light 02 0, 9,o #

N

/

M:

>= Movement facilitated m>l Movement discouraged O

Traffic guide O

Traffic conc X Traffic barricade DESCRIPTION:

1.

Discourage northbound movement along Epping Rd.

2.

Facilitate traffic turning west onto Route ll1A or continuing west on Route lilA.

MAN t'OWER/EOU IPMl?NT 1

traffic guide 3

cones

-x

Traffic Control Post No. F-EX-06 (Summer,'only)

ERPA: F

~

TOWN:

Exeter LOCATION:

Intersection of Route 101C and Spur Road NODE:

46 Spur Road Light 00 Lt

/

p ptoU n

gbt Route 101C e---

=

4' O

O Light 1

oute 88 Ky:

=

Movement facilitated

= l Movement discouraged Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate westbound traffic movement onto, and alcaq, Hampton Road, Route 101C.

2.

Discourage eastbound traffic movenent along Route 101C northbound along Spur Road and southbound along Route 88.

MANPOWER / EQUIPMENT 2

traffic guides 14 traffic cones o

1 Traffic Control Post No. F-KI-01 ERPA: F TOWN:

Kingston 10 CATION:

Routes 107, 107A, 125 & 111 NODE:

127, 116 u

I Route Route 111 I

l I

Route 107 y ooo h7

~

~

f o

O Light M

o h

o I

h Ligh t 1

I

\\

\\

Route 125

\\

\\

l Route 107A i

MI

> Movement facilitated

=; Movement discouraged

@ Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage eastbound traffic on Routes 107 and 107A.

2.

Facilitate southbound movement along Route 111 and all permitted movements through intersections.

MANPOWER / EQUIPMENT 2

traffic guides 12 traffic cones 2

barricades

Traffic Control Post No. F-KI-02 ERPA: F TOWN:

Kingston LOCATION:

Route 107 & Route 125 NODE:

114 Route 125

}\\

Route 107 i

J X

\\

000 l

)

} \\

Route 125/107 M:

> Movement facilitated Ol Movement discouraged O

Traffic guide O

Traffic cone

>< Traffic barricade DESCRIPTION:

1.

Discourage southbound movement along Route 125/107.

2.

Facilitate traffic moving north on Routes 107 and 125.

MANPOWER / EQUIPMENT 1

traffic guide 2

barricades 3

traffic cones

I Traffic Control Post No. F-KI-03 ERPA: F TOWN:

Kingston LOCATION:

Intersection of Route 125 and Route 111 NODE:

126 Route 125 Route 111 R/

Light - 1,.

( cr g

h

(

N g:

>- Movement facilitated

=l Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1. Facilitate through traffic mvcrents westbound along Route 111 and along Route l*3 in both directions.
2. Dis <nurage all turn rovements exceot for eastbound traffic along Ibute 111. Discourage eastifA:nd movement along Route 111.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones

o Traffic Control Post No. Y-KI-04 ERPA: F TOWN:

Kingston LOCATION:

Intersection of Route 111 and Old Haverhill Road NODE:

Route 111 N

[

o

//

00o 5

'f i

o Old Haverhill Road 9

gh Route 111 M:

>- Movement facilitated

> l Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate southbound traffic movement along Route 111.

2.

Discourage northbound traffic movement along Route 111

~

and southbound along Old Haverhill Road MANPOWER / EQUIPMENT 1

traffic guide 9

traffic cones O

Traffic Control Post No. F-NF-01 ERPA: F TOWN:

Newfields LOCATION: ' Route 108 & Route 85 NODE:

304 I

i l

\\

l s

0000 O C l l e

Route 108 Route 85 N

O Il O

o

/_

O O

O E.*X3 Movement facilitated

= ; Movement discouraged 8 Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate northbound movement on Route 108.

2.

Facilitate left turn movement from Route 85 to Route 108.

3.

Discourage southbound traffic on Route 108 and on Route 85.

MANPOWER / EQUIPMENT 2 traffic guides 12 traffic cones

Traffic Control Post No. F NF-02 EPPA: F.

TMN:.

Newfields LOCATION:

Intersection of Route 85.and Route 87 NODE:

180 h

oute 87 1f d

Route 85 Npg ye R

O'o o 1

t M8 Movement facilitated

= ; Movement discouraged

@ Traffic guide O

Traffic cone

)<

Traffic barricade DESCRIPTION:

1. Facilitate traffic rovernents from Route 85 onto Poute 87 Westbound.
2. Discourage northbound traffic rovannt on Route 85 unless Route 87 is congested.
3. Discourage southbound movsent cn Route 85.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones

.e

.A__

Traffic Control Post No. F-NT-01 ERPA: F TOWN:

Newton LOCATION:

Intersection of Route 108 and Peaslee Crossing _ Road NODE:

Route 108 i l o

u Peaslee g

s' Crossing Roa e

~%

\\ I

} f s.

I

~

Light.

< Route 108

. M8 Movement facilitated

? ; Movement discouraged 9 Traffic guide O

Traffic cone O

)( Traffic barricade DESCRIPTION:

1.

Facilitate southbound traffic novement along Route 10

~

2.

Discourage northbound movement along Route 108.

MANPOWER / EQUIPMENT 1

traf'fic guide 3

traffic cones

Traffic Control Post No. F-NT-02 ERPA: F TOWN:

Newton

.' LOCATION: Intersection of Route 108 with Bear Hill Road and

~

Maple Avenue NODE:

124

.tacle Avenue Route 108 o'

o R

g

/

N O

O o

\\

o Bear Hill o

m,' oo oad 94e s

o s

gh Route 108 3

Movement fac'ilitated r ; Movement discouraged 9 Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate southbound traffic movements onto, and along, Route 108..

2.

Discourage northbound traffic movements along Route 108 and along' Maple Avenue.

Discourage southbound movement along Bear !!ill Road.

MANPOWER / EQUIPMENT 2

traffic guides 15 traffic cones

Traffic Control Post No. G-GR-01 ERPA: G TOWN:

Greenland LOCATION: Post Rd. (Route 151) & Breakfast Hill Rd.

NODE:

158 h

Post Road N

(Route 151)

Breakfast Hill Road

(

e O

}

O O )O

\\ ;O C

f E*X.*

Movement facilitated Ort Movement discouraged

@ Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate traffic turning north onto Post Rd.

or continuing north on Post Rd.

2.

Discourage eastbound and southbound traffic.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

I-Traffic Control Post No. G-GR-02 ERPA: G TOWN:

Greenland LOCATION:

Intersection of Ocean Road and Route 101 NODE:

160

] \\

N 41Ok t

\\

0O o

Route 101 US an-Movement facilitated I

l Movement discouraged

@ Traffic ~uide g

O Traffic cone

)C Traffic barricade

""~

DESCRIPTION:

1.

Facilitate all novenents onto Route 101 northbound.

2.

Discourage eastbound and southbound novements.

MANPOWER / EQUIPMENT l'

traffic guide 6

traffic cones O

l l

Traffic Control Post !!o. G-GR-03

- ERDA:

G TOWN:

Greenland l

. LOCATION:

Intersection of Route 151 and Route 101 l

l NODE:

158 4 \\

Light

'N l

Ll9 l

9 Route 101 sh' l

0 l

l I

Route 151 i l l

I K.*Z8 l

>- Movement facilitated j

= l Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade j'

DESCRIPTION:

1.

Facilitate all novenents onto Route 101 castbound.

2.

Discourage noverents onto Route 151 northbound (north of Rt. 101) and southbound.

MANPOWER / EQUIPMENT 1

traffic guide

(

6 traffic cones

Traffic Control Post No. G-NC-01 ERPA: G TOWN:

New Castle.

LOCATION:

Wentworth Road at the Bridge to Portsmouth NODE:

j i N

Portsmouth E

e-Wentworth Road g

g#

.)

Route 1B

/

New Castle M8 Movement facilitated Movement discouraged O Traffic guide

() Traffic cone'

)( Traffic barricade DESCRIPTION: 1.

Reverse the direction of all inbound (i.e. eastbound) traffic.

2.

Facilitate the traffic movement westbound along Route 1B toward Portsmouth.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic barricades

i Traffic Control Post No. G-NC-02 ERPA: G TOWN:

New Castle LOCATION:

Portsmouth Avenue at the Bridge to Portsmouth NODE:

O N

Portsmouth Avenue, Route 1B

.ap__ _,

G r y

=r -

Portsmouth New Castle l

l E*18 Movement facilitated Movement discouraged l

Traffic guide O

Traffic cone

)C Traffic barricade

1. Reverse the direction of all inbound (i.e. westbound)

DESCRIPTION:

traffic.

2. Facilitate the traffic movement westbound along Route 1B toward Portsmouth.

MANPOWER / EQUIPMENT 1 traffic guide 3

traffic barricades

Traffic Control Post No. G-PO-01 ERPA: G TOWN:

Portsmouth LOCATION:

Route 1 Bypass traffic circle NODE:

129 a 195 stort@

Spaulding Turnpike

?'93 1

-/-

Route 1 V

[Hote ll '

U b

+

rw

>- Movement facilitated WI Movement discJuraged O Traffic guide O

Traffic cone

,X Traffic barricade DESCRIPTION:

1.

Discourage movements to southbound I-95 and southbour Route 1.

2.

Facilitate movements around traffic circle

'either to Route 1 (Bypasc), to Spaulding Turnpike or to I-95 northbound.

MANPOWER / EQUIPMENT 4 traffic guides 10 barricades

Traffic Control Post No. G-PO-02 ERPA: G T_OWN:

Portsmouth LOCATION:

Market St. & I-95 Interchange NODE:

280 l

\\

l O U O.

l l

l l

l k

I i

Interstate Route 95 5

=

x x x.

s LightI

-l

\\

\\

N-r

\\l l8 I

d Ol l

O g 01 i

8 O

Market Street

=

Movement facilitated l

bl Movement discouraged l

O Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate entry to northbound I-95.

2.

Discourage westbound traffic on Market St.,

entry to southbound I-95 and exiting via northbound I-95 off-ramp.

@ FOWER/ EQUIPMENT 2

traffic guide 10 traffic cones 3

traffic barricades g

T i

Traffic Control Post No. G-PO-03 ERPA: G TOWN:

Portsmouth LOCATION:

Middle St. & Miller Ave.

NODE:

118 d

Middle St.

N Light Hospital i l Summer St.

y Miller Ave.

1-(

\\ s.

)

00 O E.*Zl

=

Movement facilitated

>l Movement discouraged

@ Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitato northbound ' movement on ' Middle St.

2.

Facilitate traffic turning north onto Middle St.

MANPOWER / EQUIPMENT 1

traffic guido 3

traffic cones

Traffic Control Post No. G-PO-04 ERPA: G TOWN:

Portsmouth LOCATION:

State St. t Middle St.

NODE:

117 John Paul Jones !!ouse A

State St.

M morial O

Bridge

~

O Service Station N

=

Middle St.

E.2X3 Movement facilitated

=l Movement discouraged O

Traffic guide O

Traffic cone X Traffic barricade DESCRIPTIOt!:

1.

Facilitate traffic turning north onto State St.

2.

Facilitate westbound traffic on Middle St.

MANPOWER / EQUIPMENT 2

traffic guides 3

traffic cones

t Traffic Control Post No. G-PO-05 ERPA: G TOWN:

Portsmouth

- LOCATION:

Congress St. & Maplewood Ave.

NODE:

121 b To Route 16 Maplewood St.

Municipal Parking i l Islington St.

Congress St.

O i(

e From Light Memorial 8

Bridge 300 Drug Public Store Library N-Middle St.

?.*X 3 Movement facilitated

t Movement discouraged Traffic guide O

Traffic cone X

Traffic barricade DESCRIPTION:

1.

Facilitate westbound traffic on Maplewood Ave.

MANPOWER / EQUIPMENT O

2 traffic guides 10 traffic cones

.~.

Traffic Control Post No. G-PO-06 ERPA: G TOWN:

Portsmouth

, LOCATION:

Intersection of Maolewood Avenue and Dennet Street NODE:

142 j (

To Woodbury Avenue To I-95 Northwest St.

Myrtle Light Ave.

N O

')

0 N8g,,,

j] g Dearborn Street ext.

Oe 4

O Light

-l 0

0 000 Dennett Street Maplewood Ave.

Dearborn Street E.*X.3 Movement facilitated

=rl Movement discouraged O Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate movement west on Maplewood Ave.

2.

Facilitate turns onto the Route 1 Bypass Access Rd., Myrtle Ave.

MANPOWER / EQUIPMENT 2

traffic guides i

9 traffic cones

Traffic Control Post No. G-PO-07 ERPA: G TOWN:

Portsmouth LOCATION:

Interchange of Route 101 with I-95 southbound NODE:

243 0

0 s

\\.

O \\

\\ Route 101 i

s

\\

k O

i 1

N 5

t i

I I

I X

g X

I-95 y

S/B f

Oo g:

I i

Light

=

Movement facilitated

= l Movement discouragr+d

@ Traffic guide O

Traffic cone

)( Traffic barricade DESCRIPTION:

MANPOWER / EQUIPMENT 1

traffic guide 9

traffic cones 4

barricades

Traffic Control Post No. G-PO-08 ERPA: G TOWN:

Portsmouth LOCATION: Greenland Road (Route 101) at Northbound I-95 Ramo NODE:

242 Orchard Park i

l N

H d

Greenland Road. (Route 101)

I i

O

_S O_O g 03-O 0

x _

= m; 0 r

n---__.----.-_._-_...____

O l

t I

Northbound j

1-95 Access I

g:

O Movement facilitated l

3l Movement discouraged O Traffic guide O

Traffic cone

)<

Traffic barricade DESCRIPTION:

1.

Facilitate movement onto I-95 northbound ramo.

2.

Discourage continued movement along Route 101.

r MANPOWER / EQUIPMENT i

3' traffic guides 12 traffic cones I

Traffic Control Post No. G-PO-09 ERPA: G TOWN:

Portsmouth

, LOCATION:

Lafayette Rd. (Route 1) & Elwyn Rd.

NODE:

174 A

YOKUMS I

M ht Lafayette Rd. N Service (Route 1)

Station Peverly Hill Rd.

gf[

Elwyn Rd.

V DJ g.

_,a/

A 9

000 M:

Movement facilitated

1 Movement discouraged O Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Facilitate northbound and westbound traffic.

2 Discourage southbound and eastbound traffic.

MANPOWER / EQUIPMENT 2

traffic guides 6

traffic cones

i l

i Traffic Control Port No. G-PO-10 ERPA: G TOWN:

Portsmouth

' ' LOCATION:

Peverly Hill Rd. & Middle Rd. (Route 101) l NODE:

173 l

l I

N Middle Rd.

000 Peverly Hill Rd.

Plains Ave.

1 I s

t l

@g

@ kO

~ kg ffo U

l Light l

Route 101 i

to I-95 4

j-Key:

i Movement facilitated j

=rl Movement discouraged O Traffic guide l

O Traffic cone

)( Traffic barricado DESCRIPTION:

1.

Facilitate movement from Peverly Hill Rd..to westbound Middle Rd. (Route 101).

2.

Facilitate westbound movement.

MANPOWER / EQUIPMENT 2

traffic guides 6

traffic cones L

Traffic Control Post No.-G-PO-ll ERPA: G TOWN:

Portsmouth LOCATION:

Intersection of Market Street and Kearsage Way NODE:

I l Kearsarge Way c:

To Route 4, 16 N

OOn

/ c,A c

Light

=

Market Street ext.

l E!DC8 Ir Movement facilitated

Movement discouraged O

Traffic guide C)

Traffic cone JC Traffic barricade DESCRIPTION:

1.

Facilitate westbound movement along Market Street extension.

2.

Discourage northbound and castbound movements on/from Kearsage Way.

MANPOWER / EQUIPMENT 1

traffic guide 3

traffic cones

I i

i Traffic Control Post No. G-PO-12 ERPA: G TOWN:

Portsmouth i

LOCATION:

Intersection of Gosling Road with Noodbury Avenue and 4

with Soaulding Turnpike NODE:

305, 306 i

d 94 Gosling Road i

41

,94e 0

,\\

U a

i s

f Toodbury Avenue I

t 4/p4

  • o Spaulding Turnpike Pease AFB Mt 1

O Movement facilitated

= ; Movement discouraged l

9 Traffic guide O

Traffic cone i

i

)( Traffic barricade i

DESCRIPTION:

1.

Discourage eastbound movements along Hoodbury Avenue and Spaulding Turnoike.

2.

Facilitate westbound movenents along these highways.

MANPOWER / EQUIPMENT i

4 traffic guides 20 traffic cones

Traffic Control Post No. G-PO-13 ERPA: G TOWN Portsmouth l

LOCATION:

Intersection of Route 1 with Ocean Rd. & with Lang Rd.

NODE:

53, 52 l

l

/

Lang Road Ygh h

94e '

Ocean U.S. Route 1 l

Road-N N

l i

Oo l

i i

l 1

t 58 Movement facilitated L

= ; Movement discouraged S Traffic guide l

O Traffic cone JC Traffic barricade l

DESCRIPTION:

1. Facilitate traffic rovemnt westbound onto Ocean Ibad. If Ocean Road is conry2stod, facilitato northbound imrarrmt along !bute 1.
2. Discourage southbound novment along Houte 1 and along Img Thyl.
3. Facilitate traffic movcrent frczn lang Ibad onto northbount U.S. Ibuto 1.

MANPOWER / EQUIPMENT 2

traffic guides 6

traffic cones l

i Traffic Control Post No. G-PO-14 l

ERPA: G TOWN:

Portsmouth l

LOCATION:

Intersection of Route.lA with Route IB (Wentworth Rd.)

NODE:

177 g

I I I

I I

l l

I L Route 1A N

i I

i l

.r X I

aL 4 f

0001 I

t i

l l

i l

M t

l r

Movement facilitated l

r ; Movement discouraged

@ Traffic guide O

Traffic cone l

)( Traffic barricade DESCRIPTION:

1., Facilitate traffic movements onto Route 1A northbound.

2.

Discourago eastbound movements on Route IB and southbound movement on Route 1A.

l MANPOWER / EQUIPMENT I

1 traffic guide l

6 traffic cones

l l

Traffic Control Post No. G-RY-01 ERPA: G l

[-

TOWN:

Rye LOCATION:

Breakfast Hill Rd., Washington Rd. & Lafayette Rd.(Rt. 1) i NODE:

58 l

0 l

l Lafayette Rd.

i N

(Route 1) l t

Light l stores l l l l

Breakfast Hill Rd.

Washington Rd.

=

8 l 0 Light Ol O

n 1

fO O

[ Stores]

l mi

~

= Movement facilitated r ; Movement discouraged 9 Traffic guide O Traffic cone

~

X Traffic barricade DESCRIPTION:

1.

Facilitate traffic turning west onto Breakfast Hill Rd. from Route 1.

2.

Facilitate traf fic turning north onto Route 1 from Washington Rd.

3.

Discourage southbound and eastbound traf fic.

MANPOWER / EQUIPMENT 1

traffic guide 6

traffic cones

Traffic Control Post No. G-RY-02 ERPA:'G TOWN:

Ryo LOCATION:

Sagamore Rd. & Pioneer Rd.

NODC:

175 h

i Light N

Elwyn.Rd.

]

Pioneer Rd.

=

g 8

O j

Light O.

O 0 00 Sagamore Rd.

Ma 2

Novement facilitated r i Movement discouraged 9

Traffic guide O

Traffic cone X Traffic barricade DESCRIPTION:

1.

Facilitate westbound and northbound traf fic. movements.

2 Discourage southbound'and eastbound traffic movoments.

MANPOWCR/CQUIPMUNT 1

traffic guido 6

traffic cones

i l

Traffic Control Post No. G-ST-01 ERPA: 'G 4

TOWN:

Stratham i

LOCATION:

Route 108 & Route 101 f

l l

r NODE:

154 l

1 l

l f

l Route 101 f

l t

i l

l

?

l 000 Rou p /108 101 s

/

I I

j 6

1 1

Route 10

/

l

/

/

s s

s 1,1,qht A

~,__ -

t

?2X' l

> Movement facilitated ri Movement discouraged 8 Traffic guide O Traffic cone

)( Traffic barricade DESCRIPTION:

1.

Discourage traffic turning eastbound on

[

Route 101 and southbound on Routes 101/108.

l 2.

Facilitate traffic movement around circio

(

to northbound Route 108.

I MANPOWER / EQUIPMENT _

i 2

traffic guides l

6 traffic cones r

+

m.

Traffic Control Post No. G-ST-02 ERPA: G TOWit:

Stratham LOCATION:

Exeter-Ilampton Expressway & Portsmouth Ave. Interchango 1100C:

215, 216 A

i Routes 101, 108)Light $

Portsmouth Ave.

g O

-)OOI

(

Q

!?

N 94e E. n n, z,"% ton Proag ay

?f,l N*Uto 3, 9

E?13

>- Movement facilitated

> 1 Movement discouraged O

Traffic guido O Traffic cone X Traffic barricado DESCRIPT10ti:

1.

Discourage northbound traffic from getting on thn exprennuay.

2.

Fac111tato northbound traffic on Portsmouth Avo.

MAtlPOWtit/LOUIPMorlT 2

traffic guidon 2 barricadon 10 traffic conon

r-l l

l Traffic Control Post No. G-RY-03 l*

ERPAt G TOWN:

Rye LOCATION:

j Intersection of Route 1A and Washington Road NODS:

24 l,

i l l

I 11 Y9h i.

9ht l',

Washington b

Road Route 1A

++

i l,

i M8 Movement facilitated

= ; Movement discouraged 9 Traffic guide l

O Traffic cone

!~

)( Traffic barricade l

DESCRIPTION:

1.

Facilitate traffic movements westbound onto liashington l

Road and northbound along Route 1A 2.

Discourago southbound traffic movemonts along Routo 1A.

l MANPOWER / EQUIPMENT 1

traffic guido 3

traffic barricados =

l,

I I

I i

r i#

I APPENDIX J 4

l DESCRIPTION OF EVACUATION ROUTE!J 1

?

l e

l l

l 1

l l

L

APPENDIX Jt DESCRIPTICH_QF EVACUATION ROUTES The following are descriptions of evacuation routes for each community in the Emergency Planning Zone (EPZ).

Towns are assigned to Emergency Response Planning Areas (ERPA) as defined l

in Table 14.

All routes terminate at the Host Reception Center assigned to each community within the EPZ (see Table 20).

ERPlu_A Seabrook -- Host is Salem Seabrook Take the r.oJt convenient path to Route 286.

Beach Proceed wust on Route 286.

Cross Route 1 and continue went onto Forest Street, following the directions to I-95 South and enter I 'J5 southbound.

At the junction of I-95 and I-495 bear right and enter I-495.

Continun on I-495 and exit either at Route 97 WestScund, or Route 213 westbound.

If Route 97 is chosen, proceed west into Salem.

If Route 213 is chosen, proceed west until the junction with Route 28.

Take Route 28 i

northbo'and to Salem.

Take the most convenient path to Route 107, Inland New Zealand Road.

Proceed west on Route 107 to I-fs5 South.

Enter I-95 southbound and procued as above.

Hsroten Beach -- Heat is_!danchanter Pro: sod north along Route 1A, Deach Road.

The preferred route is to turn left on Highland Avenue to Route 51 and continue traveling westbound on Route 51 until it becomes Route 101.

Continue west on Route 101 to Manchester.

(If Mighland Avenue is congested, continue north on Route 1A and turn left onto Church Street to travel toward Route 51.)

Alternate routes include 1.

Continue north on Route 1A past Church Stroot and turn Icft (wont) on Route 101C; travel wont to I-95 northbound.

Tako I-95 north to Spaulding Turnpike, U.S. Route 4, wontbound.

Continun went on U.S. 4 to I-93, than southbound on I-93 to Manchantor.

J-1

i l

l 1

l l

ERPA B I

Amesbury -- Host is Andover l

Northern Take the most convenient path to South Amesbury l

Hampton Road (Route 107A).

Take Route 107A i

west to the intersection of Route 107A and Route 108.

Proceed south on Route 108 into Haverhill.

Enter I-495 southbound in l

Haverhill and proceed to Andover.

l East of Market Take the most convenient path to Elm Street.

Street Move South on Elm Street to the intersection l

with Route 110.

Turn left onto Route 110 l

and enter the I-95 southbound ramp, or turn right on Route 110 to the southbound I-495 ramp.

In the latter case, travel south on l

I-495 to Andover.

In the former case i

proceed south on I-95 to Route 133.

Proceed l

West on Route 133 to the junction with Routo l

125.

Turn south onto Route 125 and proceed t

to Andover.

South of Elm Take the most convenient path to Macy Street i

Street (Route 110).

Take Route 110 to the southbound I-495 ramp.

Enter I-495 i

southbound and continue to Andover.

4 l

I l

West of Main Take the most convenient path to Hillside Street I

Avenue.

Take Hillside Avenue south, across Route 110 to the I-495 interchange.

Enter l

I-495 southbound and travel to Andover.

i, I

Wsst of Hillside l

Avenue Take the most convenient path south to Haverhill Road (Route 110).

Turn right i

(west) on Route 110 and continue into i

Merrimac.

Continue west on Route 110 or I

turn left onto Broad Street to the I-495 interchange in Herrimac.

Enter I-495 i

southbound and continue to Andover.

It i

continuing west on Route 110, travel to the I-495 southbound ramp.

Enter I-495 south and proceed to Andover.

f I

EAljsbury -- Host is Peak 2d2

(

Salisbury Proceed south along Route 1A and turn went i

Beach onto Beach Road (Route 1A).

Continue west j

l J-3 i

l

\\

i ERPA C Kensincton -- Host is Manchester Northern Section Take the most convenient path to Route 150 northbound.

Travel north on Route 150 to the intersection with Route 108..

Turn south onto Route 108 and proceed to the l

intersection with Route 107.

Turn right (west) cnto Route 107 and proceed to the intersection with Route 111.

Turn left (south) onto Route 111 and proceed to the I-93 interchange. Enter I-93 northbound and j

proceed to Manchester.

i Southern Take the most convenient path to Route 107 section westbound.

Travel west on Route 107 to the intersection with Route 111.

Turn left l

(south) onto Route 111 and proceed to the l

I-93 interchange.

Enter I-93 northbound and proceed to Manchester.

l t

South Ha-eton -- Hont is Salen Take the most convenient path to either Route 107 or Route 107A.

Travel westbound on either route to Route 108.

Travel south on Route 108 into Haverhill, to the intersection with Route 110.

Turn northbound onto Route 110 to the interchange with I-495.

Enter I-495 southbound and travel to the exit at Route 97 Westbound, or Route 213 westbound. If Route 97 is chosen, proceed West into Salem.

If Route 213 is chonen, proceed west to the intersection with Route 28 or I-93.

Take either l

northbound to Salem.

l s

I l

i J-5

l on Route 101C to Route 108 (Portsmouth Avenue).

Turn right (north) onto Route 108 and travel to Dover.

North Hameten -- Host is Dover East of U.S. Rt. 1-Take most convenient path to either Route 101D (Atlantic Avenue) or to South Road, whichever is closer, and travel westbound toward Route 1.

From Route 1010, either continue west toward Route 151 or turn right (north) onto Route 1.

If travelling to Route 151, turn right (north) onto Route 151.

Travel north on l

Route 151 Route 101.

Turn right (east) onto l

Route 101 and proceed to the I-95 northbound raep.

Take I-95 northbound to the Spaulding Turnpike westbound (U.S. Route 4) into Dover.

If turning north onto U.S. Route 1 from Route 101D or from South Road, travel north to Breakfast Hill Road.

Turn left (west) onto Breakfant Hill Road and travel to Route l

151.

Turn right (north) onto Route 151 and proceed to Dover as describ6d above.

If more convenient, take Mill Road north to Washington Road, then west to U.S. Route 1.

Turn right (north) on Route 1 and travel, via Route 1 Bypass to Portsmouth Circle.

Take Spaulding Turnpike U.S. Route 4, from there west to Dover.

West of U.S. Rt. 1-Take the most convenient path to Route 151.

Take Route 151 north and proceed to Dover an described above.

J-7

r l

t Western Section j

West of l

Broad St.

Take the most convenient path to High Street (Route 113) westbound.

Travel west on Route 113 to the I-95 interchange.

Enter I-95 southbound and proceed to Peabody.

i Newbury -- Heat la Peabody I

Plus Island Proceed to the Plus Island Turnpike westbound.

Take Plum Island Turnpike west to Ocean Avenue.

Turn south (left) on Ocean Avenue which becomes Rolfe Lane.

Proceed south on Rolfe Lane to the intersection with l

Route 1A.

Turn south (left) onto Route 1A l

and proceed to Peabody.

Inland Take the most convenient path to either l

Route 1 south, I-95 southbound or Route 1A southbound.

Proceed along any of these l

routes southbound into Peabody.

l l

f I

l t

l i

[

f t

I I

1 l

i L

i e

I e

I J-9

(

i

I i

l l

l l

i For those who access Route 111 in Exeter, travel west on Route 111 to I-93 northbound i

l and proceed to Manchester.

Newfields -- Most is Manchester For most evacuees, take the most convenient path to Route 87 west.

Travel west along Route 87 to the intersection with Route 125.

Turn north (right) onto Route 125 and i

proceed to the intersection with Route 152.

I Turn want (left) onto Route 152 and proceed 4

to the intersection with Route 4.

Turn west (left) onto Route 4 and proceed to the I-93 interchange in Concord.

Enter I-93 southbound and take I-93 to I-293 and into Manchester.

Kinaston -- Host is M:_c =CA= * = t-sQt 1

Take the most convenient path to Rcate 111 south.

Proceed along Route 111 to the I-93 interchange.

Enter 4 91 northbound and proceed to Menehestee, d0" # ""

34 t v,*1 Newton -- Most is Mancheeter-f Take the most convenient path to Route 108 south.

Proceed south on Route 108 to the l

intersection with Route 110.

Turn north onto Route 110 and travel to the interchange with I-495.

Enter I-495 southbound and travel to the interchange with I-93.

Enter I-93 northbound and proceed to Meneheeter.

A ssen I

i l

l 1

l l

J-11

l b

l l

Rye -- Hort in Dovar South of r

Rye Harbor State Park Proceed west along Grove Road to the f

intersection with Washington Road.

Continue l

west on Washington Road to the intersection with Route 1.

Turn right (north) onto Route 1.

Proceed north on Route 1 onto the Route 1 Bypass in Portsmouth.

Enter the Portsmouth Traffic Circle and exit onto I

Spaulding Turnpike *(U.S. Route 4).

Continua north on Route 4 into Dover.

North of Rye Marbor Proceed north along Route 1A.

Route 1A State Park becomes Sagamore Road in fortsmouth.

Cross South Street in Portsmout's and continue on Miller Avenue.

At the irtersection of Miller Avenue and Middle Street turn right r'

(north) onto Middle Street.

Continue north on Middle Street through the intersections of State Street and Congress Street onto Maplewood Drive.

Continue on Maplewood Drive to Spaulding Turnpike.

Enter northbound Spaulding Turnpike and travel north to Dover.

Stratham -- Most is Manchester Take the most convenient path to Route los north.

Proceed north on Route los to either the intersection with Route 152 or with Route 4.

Turn west on Route 152 or Route 4 and continue to the junction of Route 4 and Route 152.

Continue west on Route 4 to the entry ramp to I-93 southbound.

Take I-93 south to I-293 and then inte Manchester.

I i

f t

i

[

i l

t l

a-12 l

f F

i

.