NUCLEAR POWER BUSINESS UNIT 0122H P-OPER ATING INSTRUCTIONS MINOR

' p, Revision 5 CHANOING BORIC ACID CONCENTRATES January 25,1997 FILTERS (F-5A&B)

Unit RECORD PROCEDURE VERIFIED CURRENT AND ClECKED FOR TEMPORARY CHANGE 3 IF FIELD bale COPIES REQUIRED. USE PDF@26 IAW NP 12 4 AND DO EQI COMPLETE TH1$ BLOCK DSS 1

BY; DATE:

1.0 PURPOSE To provide detailed instructions for changing the boric acid concentrates filters, F-5A&B.

2.0 REFERENCES

IR 96-006, NRC Inspection Report; NRC Commitment for Operations procedures PMT/QC reviews.

3.0 PRECAUTIONS AND LIMITATIONS Review precautions and limitations of 01-22.

INITIALS 4.0 INITIAL CONDITIONS In addition to the initial conditions of OI-22, ensure the following:

4.1 A 15/16" wrench and/or socket is available 4.2 A 1/2" banding kit is available 5.0 PROCEDURE 5.1 Flush the filters with reactor makeup water or demineralized water to the concentrates tank until there is a level increase of greater than 20%.

4 5.1.1 Reactor makeup water can be used by filling the appropriate boric acid evaporator feed tank and pumping same through the Siters.

~

5.1.2 Demineralized water is available from a connection in the Unit 2 sample room. Remove the inlet pressure gauge on the filters.

Rig a hose from the inlet pressure gauge connection to the demineralized water connection in the Unit 2 sample room.

a 9702180268 970210 Page1of2 REFERENCE USE PDR ADOCK 05000301*-

i P

PDR

2 NIJCLEAR POWER BUSINESS UNIT OI 22H OPERATING INSTRUCTIONS MINOR

' p Revision 5 CHANGING BORIC ACID CONCENTRATES January 25,1997 FILTERS (F-5A&B)

INITIALS 4

140TE:

Removal of the heater controlfuse might blow thefuse. Check that j

thefuseis goodafter replacing it.

5.2 Deenergize the heat tracing circuits by removing the fuse in the heater control box.

J 5.3 Shut the filters inlet and outlet valves.

5.4 Drain the filter vessel to a floor drain.

5 NOTE:

Filter vesselinsulation and heat tracing comes offin two sections.

5.5 Remove filter vessel insulation and heat tracing.

5.6 Loosen four (4) top flange bolts and remove the top flange.

5.7 Manually lift out the old filter and dispose of per HP instructions.

)

5.8 Inspect and clean the vessel, top flange and seating surface.

5.9 Wet new O-ring with DI water, install new filter element and re-secure top flange.

5.10 Shut the vessel drain valve.

l PMT 5.11 Fill and vent. Leak test the top flange with either boric acid evaporator feed tank pump discharge pressure or demineralized water header pressure.

5.12 When tested satisfactory, valve in for normal operation.

5.13 Reinstall the filter vessel insulation and heat tracing.

5.14 Energize heat tracing circuits by replacing the fuse in the heater control box.

5.15 Inform PAB Auxiliary Operator and control room of filter status.

5.16 Pump flush water in boric acid concentrate tank back to a holdup tank.

5.17 Ensure the area is cleaned up and checked for contamination.

5.18 Decontaminate and return tools to storage location.

i 1

i l