Text
i f
4 00CKETED UNITED STATES OF AMERICA US?lRC NUCLEAR REGULATORY COfEISSION
'g Before the Atomic Safety and Licensing Board
',. - g.,,
- i. -
l-In the Matter of
)
Philadelphia Electric Company
)
Docket Nos. 50-352 (Limerick Generating Station,
)
50-353 Units 1 and 2)
TESTIMONY OF B.W. BARTRAM, G.F. DAEBELER, C.F. GUARINO, G.D. KAISER S. LEVINE, E.R. SCHMIDT, A.L. TOBLIN, R. WALLER RELATING TO CONTENTION CITY-15 Contention City 15, as admitted by the Atomic Safety and Licensing Board, reads as follows:
The DES does not adequately analyze the Contamination that could occur to nearby liquid pathways, and the City's water supplies sourced therefrom, a: a result of precipitation after a release. A reasoned decision as to environrental impacts cannot be made without a site specific analysis of such a scenario.
The DES addresses at great length releases to ground-water (DES at 5-34 ej seq. ), but gives only a cursory end conclusory discussion of contamination of open water (DES at 5-33). This issue is of crucial concern here as the two major water bodies at and near the facility are the City's only water supplies. The City also has open reservoirs within its boundaries which l
could be contaminated through precipitation. For an issue of such great importance, insufficient consideration has been given here. The mandate of NEPA to take a hard look at environmental consequences has been ignored.
INTRODUCTION AND
SUMMARY
l B.W. Bartram 1.
The purpose of this testimony is to estimate the public G.F. Daebeler risk associated with the contamination of the City of 8406060085 840604 PDR ADOCK 05000 T
1 l
~ - - _.. _ _ -,. -.
G.D. Kaiser Philadelphia's (" City") drinking water af ter a severe acci-S. Levine dent at the Limerick Generating Station. A probabilistic i
E.R. Schmidt treatment of the levels of contamination of the drinking A.L. Toblin water is also provided.
B.W..Bartram 2.
This testimony considers the deposition of airborne radio-G.F. Daebeler nuclides onto the Schuylkill and Delaware watersheds and G.D. Kaiser predicts Complementary Cumulative Distribution Functions S. Levine (CCDFs) of the concentration of those radionuclides that E.R. Schmidt are the most important contributors to the longer term A.L. Toblin contamination of water supplies, strontium and cesium.
This is accomplished using a computer model that was originally developed for use at Indian Point (Ref.1, Appl. Exh.
- Ref 2, Appl. Exh.
).
This testimony considers dry deposition as well as the " rainout" scenario postulated by the contention. CCDFs of the con-centration of strontium and cesium are calculated for drinking water supplies taken from the Delaware and Schuylkill Rivers. The probability that these rivers will be contaminated above the Pennsylvania Emergency Management Agency's (PEMA) Protective Action Guides (PAGs) is shown to be very small. The probability of contamination of the drinking water supplies as a result l
of direct deposition onto the raw water basins or other open reservoir at the City's water treatment facilities is also discussed.
It is shown that the contamination of drinking water after reactor accidents as a result of 2
- .~
0 atmospherically deposited radionuclides or as a result of direct deposition onto the raw water basins or other open reservoirs is a small contributor to risk compared with the risk arising from the airborne pathways and therefore may be properly neglected in terms of overall risk considerations.
B.W. Bartram 3.
This testimony also contains in the context of an envi-G.F. Daebeler ronmental impact evaluation some general discussion of C.F. Guarino countermeasures that could be considered in both the G.D. Kaiser short and long term in the extremely unlikely event that S. Levint in the rivers or raw, in-process, or finished water E.R. Schmidt were to be contaminated above PEMA's PAGs.
It should be A.L. Toblin clear, however, that the Applicant believes that its R.
Waller evaluation demonstrates that the probability and risk associated with this pathway is so small that specific planning considerations are not required; in any event this testimony does not purport to consider the emergency planning requirements of 10 CFR part 50 Appendix E, or NUREG-0654.
DESCRIPTION OF MODEL B.W. Bartram 4.
The model used in the preparation of this testimony has G.F. Daebeler the following parts; (1) calculation of the amount of G.D. Kaiser radioactive material deposited in each watershed (i.e.,
3
S. Levine Schuylkill and Delaware) for each combination of fission E.R. Schmidt product source term, weather sequence and wind direction, A.L. Toblin using CRAC2; (2) calculation of the consequent time de-pendent concentrations of radioactive strontium and cesium in the City drinking water supplies; (3) relating the drinking water concentrations to population dose; (4) repetition of the calculations for different wind direc-tions, weather sequences and fission product source terms in order to compile CCDFs of radionuclide concentrations in water and CCDFs of population dose. The analysis focuses on strontium and cesium because, by virtue of their potentially large release quantities, relatively long radiological half lives, and recognized radio-toxicity, they dominate the long term contamination of ingestion pathways (Ref. 2, Appl. Exh.
- Ref. 3, Appl.
Exh.
).
WASH-1400 also considered strontium and cesium as the principal contributors to long-term doses received via the ingestion pathways (see WASH-1400 Ap'fendix VI,
- p. 8-22, Ref. 4, Appl. Exh.
).
However, when consider-ing population doses arising from the drinking of con-taminated water in the short term (e.g., one month), con-133 sideration is given to other radionuclides, such as 7
131 and I as discussed in paragraph 18 below.
G.D. Kaiser 5.
The amount of radioactive material initially deposited on S. Levine the two watersheds is calculated by the CRAC2 code, using E.R. Schmidt the methods and assumptions described in Chapter 10 and 4
.-.- -. ~...-.
r I
Assessment (SARA) to calculate the point estimate CCDFs.
For each weather sequence and source term, CRAC2 cal-culates the activity of each radionuclide deposited on the ground in Curies per square meter, as a function of distance from the reactor. This information, together with informatior, on the plume width as a function of dis-tance downwind, is used by the LIQPATH code.
G.D. Kaiser.
6.
The LIQPATH code is a modification by NUS of the code E.R. Schmidt IPRES that was used at the Indian Point Hearings (Ref. 1;,
A.L. Toblin Appl. Exh.
3 Ref. 2, Appl. Exh.
).
LIQPATH takes the deposited levels of radioactivity provided by CRAC2 and calculates the total amount of strontium and cesium that is deposited in the Schuylkill or Delaware watershed.
This is done in the code by essentially overlaying the plume footprint on a map of the watershed and integrating the deposited activity over that part of the plume that lies within the watershed.
It should be noted that the deposition in the watershed also includes that directly j
deposited in the river.
l B.W. Bartram 7.
Once the total amount of each radionuclide that has been l
G.D. Kaiser deposited within each watershed has been calculated, the
(
E.R. Schmidt LIQPATH code predicts.the subsequent temporal variation I
of the concentration of each radionuclide in the City of A.L. Toblin i
Philadelphia drinking water. Physical phenomena which i
5
O influence these concentrations include radioactive decay, run-off, erosion, ground water transport, sediment scaveng-ing enroute and possible removal of radionuclides by the water treatment system itself and are empirically treated as discussed below.
B.W. Bartram 8.
The LIQPATH code contains an empirical correlation that
(
G.D. Kaiser relates the quantity of a radionuclide deposited in the A.L. Toblin watershed to the subsequent concentration in City drinking water. This correlation, which is described in detail in l
Appendix 1, is based on the analysis by Codell (Ref. 2, l
Appl. Exh.
), which correlated the measured rate of 90 r from atomic bomb tests with measured fallout of S
90 r in New York City tapwater over a concentrations of S
period of about twenty years. This correlation is shown l
in Figure 1, which is reproduced from Codell's work.
l Within LIQPATH, this correlatior is described by an l
l empirical expression that contains a number of parameters l
l (see pp 12 and 19 of Ref. 2, Appl. Exh.
) that are l
determined by fitting the data as described in j
Appendix 1.
l B.W. Bartram 9.
A correlation similar to that given for New York City G.D. ' Kaiser drinking water is applicable to any watershed and l
A.L. Toblin any radionuclide, although the numerical values of the J
l parameters may change. The appropriate parameters for a l
l l
6 i
I
~ - -
given watershed can be calculated given a data base consisting of the salient variables (in this case deposition rate and drinking water concentrations). The parameters in the correlation can then be adjusted so that a best fit of the data base is obtained. This parametric adjustment has been made in the calculations described herein.
B.W. Bartram 10.
With regard to data on which to base the correlation G.D. Kaiser parameters, a long term, continuous monthly record A.L. Toblin of fallout rate is available as a function of latitude (Refs. 5, 6 and 7,, Appl. Exh.
and
) and has been used in the calculations described in this testimony. By far tne. best available data on tapwater concentrations is that for New York City, for which there is a nearly con-90 tinuous, monthly data base of Sr from 1954 through late 137 s (Ref. 8, 1981, and a seventeen-year data base of C
Appl. Exh.
).
This New York City tapwater concentra-tion data base is unique. For the Schuylkill and Delaware Rivers, limited data are available from a number of sources. The Department of Health, Education, and Welfare (REW:
Ref. 9, Appl. Exh.
) measured quarterly 90 r concentrations in the Delaware and Schuylkill Rivers S
at Philadelphia (and other rivers such as the Susque-hanna) sporadically from the third quarter of 1959 through the third quarter of 1967. The Philadelphia 7
Electric Company (PECor Ref. E, Appl.
Exh.
) took 90Sr measurements in the Schuylkill River in the vicinity of Limerick between June 1971 and October 1977. The Environmental Protection Agency (EPA; Ref. M, 90 r measurements in Appl. Exh.
) has taken infrequent S
the Delaware River at Trenton, New Jersey (as well as other rivers such as the Susquehanna) since 1976. A sin-gle 90 r measurement on May 8,1979 was taken for the S
City of Philadelphia Water Department from finished water at each of its three major plants as well as from one distribution point. The results of this single measure-ment appear to be high when compared with the concurrent EPA readings and internally inconsistent (the concentra-tion at the distribution point is greater than at any of l
the plants).
B.W. Bartram 11.
Figure 2 shows the comparability of the concentrations in G.D. Kaiser the Schuylkill, Delaware, and New York City tapwater.
A.L. Toblin The Susquehanna River data indicate similar comparability.
This is expected for the following reasons; o The deposition (fallout) rate is latitude dependent (Ref. 7, Appl. Exh.
); these watersheds are at 90 r and S
similar latitudes (i.e., the quantities of 137Cs falling on each watershed per unit area are approximately equal).
l 8
~ -
4 i
s o The watershed dynamics (e.g., removal rates) in response to deposition is. expected to be similar for these northeast United St'ates sites, which have similar values for rainfall, run-off and sediment yield (i.e., the fraction $ of the total 90 r removed S
over a given time are equal, Ref. 12, Appl.<Er.h.
).
o The flow rates per unit watershed area are approximately
\\
equal for these systems, (Ref. 13, Appl. Exh.
).
B.W. Bartram 12.
In order to extend the limited Schuylkill and Delaware G.D. Kaiser River radionuclide water concentration data bases (to A.L. Toblin obtain a long continuous record which can ba used to find i
the appropriate coefficients of the equations in Appen-dix 1), the 1959 through 1967 HEW data for each river l_
were correlated with the New York City tapwater concen-trations. Since the range of HEW concentrations is much 1
larger that that of the other measurement' programs, the HEW correlations were applied to the 28 years of New York City da'a to simulate a 28-year monthly t
l data base for each of the Delaware and Schuylkill Rivers at Philadelphia. This data base was then used to find the appropriate parameters in the expression relating initial deposition to concentrations in each of the Philadelphia rivers. Details are given in Appendix.l.
I 9
B.W. Bartram 13.
It is important to note that the New York City tapwater G.D. Kaiser data have been correlated with the Schuylkill and A.L. Toblin Delaware river water data. This approach can be used because the New York City water has minimal treatment.
There may be a further reduction in the predicted Dela-ware and Schuylkill drinking water concentrations to allow for some removal of strontium and cesium by the Philadelphia water treatment system (Ref. 14, Appl.
Exh.
).
However, it is not expected that the system as presently operated will significantly reduce strontium and cesium concentrations between the river and the
(,
drinking water and no credit has been taken for such c~
removal.
J)
B.W. Bartram 14.
As noted in paragraph 7, the expression relating the G. D. Kaiser amount of each radionuclide deposited in the watershed A.L. Toblin to the subsequent tapwater concentrations encapsulates the important physical processes that occur as the radio-nuclide is transported from the watershed to the tap-water. Other. calculations carried out by the LIQPATH code arc straightforward. These include taking the input data file from CRAC2 and calculating the total amount of each radionuclide deposited in the watershed for each combination of cource term and weather sequence, as described in paragraph 6.
The calculation of drinking water concentrations is repeated for each combinaition of 10
}
n" weather sequence, wind direction and source term. The output of these calculations is the CCDF of concentra-
~tions in tapwater, as described below.
PUBLIC RISK - WHOLE BODY DOSE B.E. Bartram 15.
The consumption of drinking water containing radio G.D.
Kaiser nuclides from a postulated accidental airborne release S.
Levine from LGS would result in radiological doses to the E.R. Schmidt population of Philadelphia. The method used to calculate A.L.
Toblin these doses from the calculated concentrations in river water and the calculated concentrations arising from direct deposition onto raw water basins or other open water bodies at the City's water treatment works is described below. Doses resulting from water used outside the body make a very small contribution to total exposure and thus are not considered further here.
B.W. Bartram 16.
First, the formulas given in Appendix 1 for the time G.D. Kaiser dependent concentrations of strontium and cesium in the A.L. Toblin river water were used; the nuclides Cs, Cs,' Sr and 'Sr were included. The population was assumed to consume this water for fif ty years and the resulting pop-ulation doses calculated in accordance with the methods outlined in NRC Regulatory Guide 1.109 as implemented in 11
the LADTAP II computer code (Ref.,15,, Appl. Exh.
Ref. 16,, Appl. Exh.
).
An exception to the methods of Regulatory Guide 1.109 was the use of ingestion dose con-version factors as given in WASH 1400 (Ref. 4, Appl.
Exh.
, p. 8-24) so as to be consistent with the analy-sis of ingestion pathways given in SARA. The Regulatory Guide 1.109 conversion factors are based on recommenda-tions of the International Commission on Radiological Protection, Publication 2, 1957 (ICRP 2), are much closer to the more recent recommendations of ICRP 30.
B.W. Bartram 17.
The LADTAP II methodology was applied separately to the G.F. Daebeler Delaware and Schuylkill rivers and to each fission pro-C.F. Guarino duct source term, since the proportions of strontium and G.D. Kaiser cesium differ between the two rivers and between differ-S. Levine ent source terms.
It is likely that the Schuylkill would E.R. Schmidt be more heavily contaminated than the Delaware (see para-A.L. Toblin graph 21). According to the City, in an emergency, the R. Waller Baxter plant, which takes water from the Delaware, can supply the City's entire needs with the exception of the Belmont High Service District and the Roxborough High Service District, which represents about 21 mgd out of the City's total needs of 324 mgd; or about 7 percent (Ref. 17, Appl. Exh.
, and Ref. 18, Appl. Exh.
).
Therefore, it was assumed that 7 percent of the City's population would be supplied by the Schuylkill and 93 percent by the Delaware.
12
B.W. Bartram 18.
With the assumptions given in paragraphs 16 and 17, it is G.D. Kaiser straightforward to calculate a CCDP of population dose A.L. Toblid starting from the initial probabilistic treatment of con-centrations of radionuclides in the river water. Since the calculations were done on the basis of strontium and cesium, this CCDF represents the chronic or long term contribution to the population dose. With regard to the contribution of other more short-lived radionuclides, such as radioiodine, a simplified calculation was made as follows. For each source term, weather sequence and winds direction, the isotopes of iodine deposited on the Schuylkill or Delaware watersheds were assumed to pass into the rivers immediately at a rate approximately fif ty times that of Strontium. This factor of fifty is a bounding factor, as approximatley 2 percent of the Strontium is expected to pass directly into the river (Ref. 12; Appl.
Exh.
).
The population of Philadelphia was assumed to consume this water and the
(
resulting increment in population dose was calculated using the methods of LADTAP II.
In this way, the CCDF calculated for strontium and cesium was modified to include iodine.
i B.W. Bartram 19.
A further potential source of radiation dose would be the i
f G.F. Daeboler consumption of water from the City's treatment works that i
l C.F. Guarino might be contaminated by direct deposition (dry or wet) 13
G.D. Kaiser on raw water or finished water basins.
In practice, much S. Levine or all of this contaminated water could be bypassed, dis-E.R. Schmidt charged to the river or sewers, or flushed through fire A.L. Toblin hydrants (see paragraph 30). For the purposes of this R. Waller calculation, however, it is assumed that all of the con-taminated water is processed through the City's distribu-tion system at the usual rate of consumption. Again, the LADTAP II methodology was used to calculate population doses arising from the consumption of this water. When combined with the probabilistic distribution of concen-l trations in water calculated by LIQPATH, a CCDF of population dose results, which was combined with the CCDF described in paragraph 18 to give an overall CCDF of population dose to the people of Philadelphia. This CCDF is shown in Figure 3.
l B.W. Bartram 20.
The area under this CCDP is 0.39 man-rem per reactor, c
G.F. Daebeler which is made up of 0.01 man-rem per reactor year from C.F. Guarino the consumption of water contaminated by direct G.D. Kaiser deposition into the system, 0.1 man-rem per reactor year E.R. Schmidt from strontium and cesium deposited on the watershed and i
A.L. Toblin 0.28 man-rem per reactor year from the iodine deposited I
l R. Waller on the watershed. This figure of 0.39 man-rem per year is to be compared with 70 man-rem per year to the people of Philadelphia from the airborne pathway as considered in SARA. Note that the population dose via the water l
14
pathway has been derived with many fewer assumptions about countermeasures than that via the atmospheric path-way; in CRAC2, protective actions such as interdiction of milk and decontamination of land are routinely assumed.
As described below, countermeasures are possible in the liquid pathway case which could give further reduction in risk. Overall, it is concluded that the public risk via the water pathway is a small fraction of that via the atmospheric pathway. This conclusion is in agreement with that of other authors (Ref. 3, Appl. Exh.
).
CONCENTRATIONS IN TAPWATER - RESULTS B.W. Bartram 21.
Figure 4 displays the complementary cumulative distribu-90 G.D. Kaiser tion function (CCDP) of the c,oncentration of Sr in S. Levine drinking water obtained from the Schuylkill, averaged over E.R. Schmidt the first month and averaged over the first year, and then l
A.L. Toblin at 1 month, 6 months,1 year and 5 years af ter the initial l
}
deposition. Figure 5 provides the same information for l
the Delaware River. These curves give the frequency with l
which the corresponding concentration is equalled or 90 cxceeded.
It is apparent that the concentration of Sr during the first month is considerably higher than that at l
l later times (the average over the first month is given, l
l since the parameters in the empirical correlation cannot l
predict in greater detail than the original data, which is I
15 i-
averaged on a monthly basis). _After 1 month, the con-centration in the river declines slowly.
B.W. Bartram 22.
In order to judge the significante of the concentrations G.D. Kaiser require that it is necessary to compare them with Federal S. Levine_
or State Guidelines. The Federal Government has pub-E.R. Schmidt lished standards for normal releases in 10CFP.20 Appen-131 90Sr, 137Cs, 134Cs, I33I and 7
A.L. Toblin dix B and the values for are reproduced in Table 1.
The Commonwealth of Pennsylvania Emergency Management Agency (PEMA) has published Protective Action Guides (PAGs) (Ref. 19, Appl.
l Exh.
)which are also reproduced in Table 1.
are based on the UsEPA National Interim Drinking Water Regulations, EPA-570/9-76-003, Appendix B; see also 40 CFR 141.16.
As can be seen from Table 1, PEMA has two sets of l
PAGs which are applicable to the situation being I
considered.
For uncontrolled discharges to surface water, and in circumstances where the water supply is influenced by contaminated run-off and fallout, the USEPA Appendix B l-concentrations multiplied by 12 will apply. This assumes that the exposure time will not exceed one year. The associated dose commitment to any organ is 50 mrem.
Second, PEMA states that, for acute crisis conditions where no other water supply is available and the duration is less than thirty days, the average concentration may reach 1,000 times the USEPA Appendix B concentrations.
]
l 1
l 16 i
The associated dose commitment to any organ is 330 mrem.
For accidents affecting Philadelphia drinking water, the
'PEMA standards have been assumed to apply.
B.W. Bartram 23..
Returning to Figures 4 (Schuylkill) and 5 (Delaware),
G.D.
Kaiser since ' Sr is principally considered as a contributor to S.
Levine the long term accumulation of radiation dose, the most 90 E.R.
Schmidt appropriate PEMA guide for comparison with Sr concentra-A.L.- Toblin tions is that for circumstances in which the water supply is influenced by contaminated run-off and fall-out, i.e.
96 pCi/l averaged over 12 months. The probability that the Schuylkill will be contaminated above this guide is one in 500,000 per reactor year, and the probability that the Delaware will be contaminated above this guide is one in 14 million per reactor year.
B.W. Bartram 24.
The above probabilities have been obtained by assuming G.D. Kaiser that no preventive actions take place. As discussed in S.
Levine paragraph 34 preventative measures which could sub-90 E.R. Schmidt stantially reduce the long term impact of Sr are A.L.
Toblin possible. Assuming that such procedures could be implemented in one month, the probability of exceeding the PEMA one year limit in the subsequent year would be in the range of one in three million to one in 30 million per reactor year for the Schuylkill and about one in a hundred million to less than one in a billion per reactor 17
year for the Delaware.
It should be noted that, as indicated in paragraph 20, even if the countermeasure are not taken, the man-rem contribution is a small fraction of that from other pathways.
B.W. Bartram 25.
The discussion given in paragraphs 23 and 24 shows that G.D. Kaiser the probability that there will be long term contamina-S. Levine tion of the Delaware even in the absence of protective E.R. Schmidt actions is quite small, and that the probability that A.L. Toblin such contamination could not be dealt with using available techniques is vanishingly small (one in a hundred million per reactor year or less). For the Schuylkill, the corresponding probabilities are about a factor of thirty higher, but even so the implementation of reasonable countermeasures reduces the probability of exceeding the PEMA long term guide to one in fif ty million per reactor year. Thus, there is a very small probability that long term interdiction of the Schuylkill would be required, and a vanishingly small probability that long term interdiction of the Delaware would be required. Note that the calculations show that there is l
less than one chance in a billion per reactor year that either the Schuylkill or Delaware will be contaminated above PEMA one year PAGs by radiocesium.
18
B.W. Bartram 26.
In the short term, the PEMA one-month PAG (8000pCi/l of 90 90 G.D. Kaiser Sr) applies. For Sr alone, the probability of S. Levine '
exceeding this limit is about once chance in 5 million E.R. Schmidt per reactor year in the Schuylkill and less than one A.L. Toblin chance in a billion per year for the Delaware. However, the one month average is complicated by the fact that 131, cannot be neglected; other radionuclides, such as I
it is expected that the radioiodines will be significant (perhaps dominant) contributors to the dose (330 rem in one month) that is the basis for PEMA's PAG.
The calculation of the rate at which iodine, deposited on a watershed, leaches into the river is not as well understood as for strontiun.. Therefore, a detailed quantitative analysis is not possible. However, uring
\\
the model for iodine concentration averaged over the I
first month, as described in paragraph 18, the iodine I
l would determine if the PEMA short-term PAGs were exceeded. There would be a chance of about one in a hundred thousand per reactor year that the PEMA short-term PAGs might be exceeded in the Schuylkill River, and about one in two hundred thousand that they might be exceeded in the Delaware River. These are upper bound 1
probabilities and, furthermore, take no account of the i
possibility of countermeasures (see paragraph 30).
19
DEPOSITION ON WATER BASINS AND RESERVOIRS B.W. Bartrds 27.
The problem described above is one of long term G.F. Daebeler contamination of the rivers as a result of C.F. Guarino deposition of long lived radionuclides such as G.D.
Kaiser strontium and cesium cn the watershed. A short term S. Levine problem may exist if radionuclides are deposited directly E.R. Schmidt onto the surface of the raw water basins at Baxter, Queen A.L. Toblin Lane and Belmont or the filtered water reservoir at East A. Waller Park.
(The Oak Lane and half of the East Park filtered water reservoirs are protected by floating covers with provisions to drain rain water to the sewers so that the filtered water would not be contaminated.) CCDFs of 90 instantaneous Sr, Cs and I concentration in these
(
reservoirs are shown in Figures 6 and 7.
Note that all l
three plants and the reservoirs are so close together (compared to a typical plume width) that they have l
essentially the same CCDF and would be contaminated at the same time.
B.W. Bartram 28.
As noted the concentrations given in Figures 6 and 7 are i
G.D. Daebeler instantaneous values in the raw water in the basins.
If C.F.
Guarino this water were to be processed (without removal of any G.D. Kaiser radioactivity) and distributed at the normal rate the i
S. Levine contaminated water would be all gone af ter approximately E.R. Schmidt 3 days. The 30 day average concentration would therefore A.L. Toblin be one tenth of that given in Figures 6 and 7.
The R. Waller likelihood that the PEMA 30 day PAG will be exceeded is l
20
therefore approximately one chance in a million per 13l reactor year based, on I.
As described in paragraph 30 countermeasures based on available techniques are pos-sible in this unlikely event. Again as noted in para-graph 20 the risk from contaminated water is small compared to that from other pathways.
POSSIBLE COUNTERMEASURES B.W. Bartram 29.
The preceeding testimony shows that the risk resulting G.F. Daebeler from the contamination of the City of Philadelphia water C.F. Guarino supply is a small fraction of the risk from other G.D. Kaiser pathways.
In making this assessment the only action S. Levine assumed to be taken was to maximize the use of Delaware E.R. Schmidt River water. No credit was taken for countermeasures to A.L. Toblin either prevent the use of contaminated water or to remove R. Waller activity from the water. The following section discusses, in general, possibly counter.-measures in order to place some perspectives on the risks involved. This discussion centers on short and intermediate term measures.
30.
Countermeasures could be implemented in the unlikely event of an accident resulting in contamination of either the Schuylkill or Delaware River water sources or treatment plants, depending upon the nature and severity of the contamination. For those occurrences which result in the early contamination of a water supply in excess of 21
the PEMA 30 day PAG, the interdiction of that source would be possible with replacement water provided from the other sources, albeit with some usage restrictions likely. Direct deposition into the uncovered portion of the East Park Reservoir can be accommodated by isolating and bypassing this reservoir. Direct deposition in a raw water basin would be most readily accommodated by bypassing the basin and processing raw water without the pre-sedimentation provided by the raw water basins. The contaminated water could also be returned to the river or flushed from the system using, for example, fire hydrants.
It should be noted that the water system has uncovered filtered water storage facilities with approximately two days supply of water (at normal usage rate) which would not be contaminated and could continue to be used.
In addition, if the water to local areas is excessively contaminated, distribution of clean drinking water by trucks is possible while continuing to use the 1
normal water supply for other purposes.
E.R. Schmidt 31.
At lower contamination levels involving watershed deposi-A.L. Toblin tion which are likely to persist for more extended C.F. Guarino periods of time, the affected water source would require R. Waller some modificationc in the water treatment processes to l
I provide reductions in the finished water concentrations.
t 22
The treatment processes currently in use (Ref. M, Appl.
Exh.
) includes o Pre-sedimentation of some suspended matter in the raw water.
o Chlorination to destroy taste and odor causing materials and for control of bacteria.
o Chemical addition of carbon or sodium chlorite for taste and odor control, lime for pH control, and alum or ferric chloride as flocculants.
o Flocculation and sedimentation to remove suspended impurities.
o Sand filtration to remove remaining suspended impurities.
l E.R. Schmidt 32.
Extensive research on removal of various fission products l
l A.L. Toblin from water was conducted from the early 1950s to the mid l
C.F.
Guarino 1960s largely as a result of concern about fallout from A.
Waller atmospheric weapons testing during that period (Ref. 20, Appl.
Exh.
).
As a result of that research, the decontamination factor provided by the current treatment processes can be anticipated to be no more than 2 (i.e.,
23
9 50% removal) for total radioactivity, and less than that for dissolved strontium, cesium and iodine. As stated in paragraph 13 no credit was taken for any removal in the treatment process.
E.R. Schmidt 33.
Modifications to the current treatment process are A.L.
Toblin feasible which could achieve reductions in the concentra-C.F.
Guarino tion of certain nuclides by factors of frca 5 to 10.
A. Waller The addition of activated carbon with the other chemicals prior to flocculation gives a decontamination factor for iodine of from 4 to 5 (Ref. 20, Appl. Exh.
Table 8.3).
Adding a layer of activated carbon to the surfaces of the sand filters would provide additional decontamination, perhaps by a factor of 2, for a total DF for radioiodine of from 8 to 10.
E.R. Schmidt 34.
Dissolved strontium can be effectively removed by A.L. Toblin the use of a lime-soda softening process normally C.F. Guarino employed to remove dissolved calcium and magnesium A. Waller carbonates and sulfates from "hard" water, due to the chemical similarity between magnesium, calcium and l
strontium (all are Group IIA elements). Decontamination factors of from 5 to 10 can be obtained by co-precipita-tion in an initial softening step with dosages of soda ash (sodium carbonate) in excess of those indicated by stoichiometric requirements alone.
"Repea ted-precipita-l tion", in which a small quantity of calcium is added and 24 l
1 L
removed provides an equal decontamination factor in each step. Thus, a second step in which a DF of between 5 and 10 is obtained, would produce an overall process DF of between 25 and 100 (Ref. 20, Appl. Exh.
).
If it were necessary to provide this second stage of processing without constructing a major plant addition, the affected plant could be operated as two sequential process lines.
That is, the treated effluent from one half of the plant would be returned to the rapid mixing stage of the other half to provide the second stage of treatment. This would, of course, also reduce the throughput capacity of the affected plant by half and would probably require additional pumping capacity.
CONCLUSION B.W. Bartram 35.
The contribution to the public risk via the drinking G.F. Daebeler water pathway is small relative to that predicted l
C.F. Guarino for the City of Philadelphia via the airborne path-G.D. Kaiser ways. The probability that there will be long term con-90 S. Levine tamination of the Delaware River by Sr and 137 s C
E.R. Schmidt even in the absence of protective measures is small, and i
A.L. Toblin the probability that such contamination could not be l
A. Waller dealt with using available techniques, is vanishingly small (one in a hundred million per reactor year or less).
For the Schuylkill River, the corresponding 25
probabilities are higher, but even so the implementation, of reasonable countermeasures reduces the probability of exceeding the PEMA long term guide to one in thirty million per reactor year. Thus, there is a very small probability that long term interdiction of the Schuylkill River would be required, and a vanishingly small prob-ability that long term interdiction of the Delaware River would be required. The probability that short term concentrations in excess of the PEMA one month PAG might occur has also been shown to be small.
If the raw and finished water basins were to be contaminated by direct deposition, the probability tht the PEMA short term PAGs would be exceeded is small and the resulting contribution to public risk is small. Countermeasures to reduce or eliminate this source of risk are possible.
l
(
3 I
26
APPENDIX 1 DISCUSSION OF THE EXPRESSION RELATING THE RATE OF DEPOSITION OF A RADIONUCLIDE
' ONTO A WATERSHED 'IO THE TEMPORAL VARIATION OF ITS CONCENTRATION IN TAPWATER B.W. Bartram 1.
An integral part of the model described in the foregoing G.D. Kaiser testimony relates the transient concentrations of radio-A. Toblin strontium (and radiocesium) in drinking water to the time history of the deposition of these nuclides. The relationship calculates the quantity of a radionuclide accumulated on land in a watershed by functionally relating the rate at which the nuclide is accumulated to both the rate at which it is deposited and its removal rate. The drinking water concentration is then considered to have components related to the immediate deposition rate (e.g., direct deposition on the water surface) and the quantity of nuclide on the watershed (e.g., erosion). Each of the functional relationships contain coefficients so that mathematical equations describing these relationships can be written. The following equations are taken from Codell's work (Ref. 2, Appl. Exh.
- p. 12) and are applicable to any watershed and any radionuclide, although the coefficients may changer 27
= AR (1-k ) - ()y + A ) M (1) y 2
C=k AR + Mk 2
3 where M
is the accumulated activity of a radionuclide on land in the watershed, which is available for transport to surface water, Curies C
is the surface water concentration, curies / liter 2
A is the area of the watershed, m R
is the rate of fallout, curies /(yr-m )
k is the fraction of the affected watershed covered by open g
water p
k is the coefficient relating the rate of fallout to 2
surface water concentration, yr/ liter k
is the coefficient relating available accumulgted fallout j
3 on land to surface water concentration, liter"
)(
is the radiological decay rate, yr-1 28 i
)'2 is the effective loss of available fallout from land due
~
to all causes other than radiological, yr B.W. Bartram 2.
For the case of an instantaneous deposition of an amount 2
G.D. Kaiser 5 Curies /m of a radionuclide within a watershed of A. Toblin area A, the solution to equation 1 is C = 6A k3 (1-k ) exp (- (ft+3)t)
(2) y 7
at time t years af ter the deposition takes place; t
should exceed the averaging period for the data on which the correlation is based, in this case one month. The average tap water concentration over time t is given by kk 2 + k (1-k ) (1-exp(-()y + >g) t))/ (7( + A ) )
(3)
C=
3 y
2 B.W. Bartram 3.
As noted in the testimony at paragraph 14, the parameters G.D. Kaiser in eqs. (1) through (3) were obtained after first i
A. Toblin correlating New York City tapwater data on radiostrontium l
with HEW data on radiostrontium concentrations in the Schuylkill and Delaware rivers.
Figure 2 shows how closely the Delaware and Schuylkill data track the New York City data. Figures 8 and 9 show these correlations.
Table 2 gives the values of these parameters for radiostrontium and radiocesium, the radionuclides of f
interest for long term contamination of the water supplies.
29 l'
E
4.
The correlation analysis leading to the coefficients for radiocesium was performed in a manner similar to that for 137 radiostrontium. Deposition rates for Cs were found by 137 s to oroportioning the 90 r rates by the ratio of C
S 9'Sr concentrations in surface air. This ratio (1.8) was found 6.o be practically constant with time (implying equal deposition velocities for these nuclides) (Ref. 21, Appl. Exh.
).
New York City tapwater concentrations 137 for Cs are shown in Figure 2.
It can be seen that 90 these concentrations track the corresponding Sr concentrations quite well, albeit at a much lower level.
13 90 The ratio of Cs to Sr concentrations in New York City water (0.10) were applied to the derived Delaware 90 and Schuylkill rivers Sr concentration data bases in 137 order to obtain the Cs concentration data bases needed to find the radiocesium coefficients of Table 2.
l t
30 l
References 1.
Direc(Testimony of Richard Codell before the Atomic Safety and Licensing Board Concerning Commission Question 1, presenting an analysis of the risk posed by contamination of the Hudson River, reservoirs and other bodies of water that could be caused by severe accidental radionuclide releases at the Indian Point Nuclear Power Plant.
2.
Richard B. Codell, 1984. Potential Contamination of Surface Water Supplies by Atmospheric Releases from Nuclear Plants, Health Physics, to be published.
3.
J. C. Helton, A. B. Muller and A. Bayer, Contamination of Surface Water Bodies t.f ter Reactor Accidents by the Erosion of Atmospherically Deposited Radionuclides, Health Physics, to be published.
4.
U.S. Nuclear Regulatory Commission, 1975. Calculation of Reactor Accident Consequences - Appendix VI of Reactor Safety Study, WASH-1400 (NUREG 75/014), Washington, D.C.
5.
Health and Safety Laboratory, U.S. Energy Research and Development Administration, 1977.
Final Tabulatioc of Monthly ' Sr Fallout Data:
1954-1976, RASL-129, New York, New York 10014.
6.
Larsen, Richard J., 1983. Worldwide Deposition of ' Sr through 1981, EML-415, Environmental Measurements Laboratory, U.S. Department of Energy, New York, New York 10014.
7.
U.S. Environmental Protection Agency, 1976, Radiological Quality of the Environment, Office of Radiation Programs, Washington, D.C.
20460.
8.
Hardy, E.
P., Jr. and L. E. Toonkel, 1982, Environmental Measurements Laboratory Environmental Report, EML-405, Environmental Measurements Laboratory, U.S. Department of Energy, New (ork, New York 10014.
31
9.
U.S. Department of Health, Education, and Welfare, 1960 through 1968, Radiological Health Data, Volumes 1 through 9.
u LimeribkGeneratingStationRadiologicalEnvironmentalMonitoring 10.
Program, 1971-1977, Prepared for Philadelphia Electric Company by Radiation Management Corporation May,1979.
11.
U.S. Environmental Protection Agency, 1976 through 1982, Environmental Radiation Data, Reports 6, 10, 15, 18, 23-24, 25-26, and 29, Office of Radiation Programs, P.O. Box 3009, Montgomery, Alabama 36193.
12.
Menzel, Ronald G.,
1975, " Land Surface Erosion and Rainfall as Sources of Strontium-90 in Streams," Journal of Environmental Quality, Vol. 3, No. 3, pp. 219-223.
13.
U.S. Geological Survey, 1982, Water Resources Data for Pennsylvania Water Year 1982 volume 1 - Delaware River Basin and Volume 2 -
Susquehanna and Potomac River Basins, Water Resources Division, P.O.
Box 1107, Harrisburg, Pennsylvania 17108.
14.
City of Philadelphia Water Department, 1982. How Water in Philadelphia is Treated and Distributed, 1180 Municipal Services Building, Philadelphia, Pa.
19107.
15.
U.S. Nuclear Regulatory Commission, 1977. Calculations of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR50, Appendix I, NRC Regulatory Guide 1.109.
I 16.
Simpson, D.
B., and B. L. McGill, 1980. User's Manual for LADTAPII - A i
Computer Program for Calculating Radiation Exposure to Man from Routine Releases of Nuclear Reactor Liquid Effluents, Oak Ridge National Labora-tory, NUREG/CR-1276.
32 1
I
- 17. Aptowies, Bruce S., 1984. Letter to Robert E. Martin, USNRC, dated April 23, 1984 and private communication, S. Gibbon, PECO and B.
Aptowl,cs, City of Philadelphia, May 25, 1984.
- 18.. Philadelphia Water Department, 1982. Table of pumping, treatment and consumption rates for FY '82, t
19.
Commonwealth of Pennsylvania Disaster Operations Plan, Annex E, Fixed Nuclear Facility Incidents, February 1984, p. E-12-42.
l 20.
Straub, C.P., 1964 Low-Level Radioactive Wastes, Their Handling, Treatment and Disposal, Division of Technical Information, United States Atomic Energy Comunission.
l 21.
Hardy, E.P., Jr., 1981, Environmental Measurements Laboratory Environ-mental Report, EML-390, Environmental Measurements Laboratory, U.S.
l Department of Energy, New York, New York 10014.
i i
i
}
l 33 l
.~,
Table 1 Protective Action Guides for Drinking Water Concentrations (pCi/ Liter) 90Sr 137 s 134 s 1311 1331 C
C 10CRF Part 20 300. 20,000 9,000 300 1,000 PEMA - uncontrolled 96 2,400 240,000 36 120 discharges to surface water and in circumstances where the water supply is influended by contaminated run-off and fallout-exposure time not to exceed 1 year PEHA - acute crisis conditions 8,000 200,000 2 x 107 3,000 10,000 where no other water supply is available-exposure time not to exceed 30 days
Table 2 Coefficients Used to Relate Deposition and Surface Water Concentrations
~1 (bared on monthly average data)
Schuylkill River Delaware River Sr-89 Sr-90 Cs-134 Cs-137 St-89 St-90 Cs-134 Cs-137 kl 0.0096 0.0096 0.0096 0.0096 0.0207 0.0207 0.0207 0.0207 A (m )
4.903+9 4.903+9 4.903+9 4.903+9 2.015+10 2.015+10 2.015+10 2.015+10 2
di (yr-1) 4.804+0 2.502-2 3.388-1 2.310-2 4.804+0 2.502-2 3.388-1 2.310-2
>2 (yr-1) 7.209-2 7.209-2 7.392-2 7.392-2 9.178-2 9.178-2 9.360-2 9.360-2 k2 (yr/1) 2.978-15 2.978-15 1.732-16 1.732-16 6.486-16 6.486-16 3.773-17 3.773-17 (1-1) 4.335-15 4.335-15 2.517-16 2.517-16 1.032-15 1.032-15 5.989 5.989-17 k3 9
- 4.903+9 = 4.903 x 10
y y
g g
g g
g 2.0 1.8
.N i.e b>
Model Data j!
1.4
.E.
.l d 1.2 s.f 5
1.0 2 3 g I 0.8 Y
l 0.6 i
E 0.4 od'
~
0.2 Modet I
0
'56
'58
'60
'62
'64
'66
'68
'70
'72
'74
'76 Year Figure 1 - Comparison Of Empirical Correlation Relating Rate Of Fallout To Concentration in Tapwater-New York City Data (Table 2 of Ref.
1, Appl.
Exh.)
e E
O s
g tt t,
o,
[ g
=
0 /
s i
j i
a
.o O
3 j'
O 3
s a a
!!5!3a 8
1 1 1 O
f'ijjj cF#
u R
4g
] 4 0 0 0o4 4< a Z 4
2
,r o 45-4 C p
0 40 -
hb
', ' ' a' d e 40 40 40 2
4
'e 40 R
a e
B f
e g
t,g u
.,3 8
[
!2 a
0
'0 A
.x o
I C
3 O
es f
1 4
e
'c c
g :
h 00 a
4 3
0 o
O O
O d-c4 Q3 0 4 3
4 0
3 c
0 4
o O
O O
O g
C 0
3 0 g 0
\\
O 4
3 00 i i e i i e
i e i e i e i t
i t
i i iit g
- 2
- : : : : : : : : : : : : : : : : : :
a non = ~ a 4
(1:
gaWoawzo> ^ z vQwx >WCxn 1
1 1
1 t
1 0
0 0
0 0
0 F
8 7
8 8
4 1
i g
0 u
r e
3 1
I C
d 0
C PC W
D aC H
tD F
hP O
w L
1 I
F aF E
0 O
d yo r 2
B R
W O
Ch io D
W 1
d' I
H tl Y
0 ye O
oB P
L fo E
E d
R 1
Py I
8 h
S 0
0 d
iD O
4 lo N
D as Y
de e
R 1
l -
E d
I D
p 0
O
,M S
8 hD ir E
ai n
Ok N
1 I
d ni 0
ln yg W
a e
0 1
t r
7
SCHUYLKILL WATERSHED - SR90 CONCENTRATION 10-4
_i..nm
.. o nuj i i onnj i.umj... n mj.. noog... n mg.. n nu l
10-5 zo H
i-
<t g
l-z W
OZo 10-e U
g Z
t H
O g
Wo X
W u.
10-7 O
3 oZ W
g O
g Q:
b.
i 10-s
=
1 MONTH AVERAGE I YEAR AVERAGE END OF 1 MONTH 1
END OF 6 MONTHS END OF 5 YEARS 10-8 5
2 d
5 10-'
10-10-'
10 10' 10 10 10 10 i
CONCENTRATION (PIC0 CURIES PER LITER.3 90 Figure 4(a) - CCDF of Concentration of Sr in Schuylkill Water l
l l
- - ~ -,. -
I lll!.IIl kewo wZo> og wXowuoH g oozowz%<&Hoz voym >W<gn F
i 1
1 1
1 1
1 g
0 0
0 0
0 0
u r
8 7
5 4
1 e
0 S
_ _ _ ~:
(
i C
4 b
i H
C n
U
)
n Y
1 O
n N
0 l
L WCE
=
i K
C 2
I aC N L
tD u
L E
D eF T i
1
)
u C
C Y
1 r
R 0
r W
oA f T O
O A
A F
F n
I 6
i A
i T
i v
n C O Y
N t
i E
o 1
A N
4 I
R E
O a
n nN 0
R T
c S
c S
H c
i H
e(
nP i
E t I n
D 1
u rC n
a 0
0 I
t iC i
C oU s
i S
nR n
1 i
1 I
u oE 0
I 3
S 2
i 7
f 3P
' I i
C 1
n 7E i
O a,
1 CR 0
I N
L i
C s
8 nI i
E i
N n
T T
o 1
0 I
R u
S E A
cR T
4 h) u n
O i
I y
l o
N k
1
~
__u 0
i 5
l l
I l
DELAWARE WATERSHED - SR90 CONCENTRATION 10-4
. i o > > >>>j i i nin.j i o iniij i ouni) i minig i i nnuj i i ning i ony 10-5 O
H 4
E W
ZW OZO 10-'
O w
Z H
O g
W g
XW 10-7 u.o O
Zw D
o W
E 1 0-'
1 MONTH AVERAGE 1 YEAR AVERAGE
~
END OF 1 MONTH END OF 6 MONTHS END OF 5 YEARS 1 0-'
10-'
10-"
10-'
10' 10' 10 10' 10 10' 2
4 CONCENTRATION (PIC0 CURIES PER LITER) 90 Figure 5(a)
CCDF of Sr Concentration in Delaware watershed
l l
l,
'11l
!1 l
-i 1ll,i a
oaw2o> oL wxuWwQHze oyowzrE<Wgoz vggy >w<mn 1
1 1
1 1
F 0_
0 0
0_
0 i
g g
e 7
e s
4 1
u r
0 D
2__
t i
E e
5C t
L O
t b N f
n A
(
1 t
o i
I W
0 r
n
)
t
=
C A
E 8
i i
R wCN I
aCT t
D D
i i
E i
d 1
t D
D v
i eF 0
t r
n tD R t
O O
A i
W t
n r
A i
F F
a v.
I A
S 1
A oT i
Y M
o i
T v
fI e
E O
i E
O s
A N
u 1
i R
T e
n Ci t
S H
c i
R o
0 I
S s
n 4
t' i
n H
c(
t i
E eP t
i nI t
i D
e I
C 1
t o
t t
n ra0 0
1 tC t
i C
iU e
i S
oR I
1 nI t
u 1
t 3
oE 0
n u
I 7
2 fS t
I C
y1 t
u O
i 0
t n
N I
C C
8 I
i E
s L
f i I t
N T
n t
n 1
t D E 0
t I
R T
n A
4 eR t
T l) t I
a t
1 t
o O
w t
0 t
o N
a t
2__
__:u r
e s
e e
BAXTER/TORRESDALE RESERVOIR - INSTANTANEOUS CONCENTRATION 10-*
_ iinun i uin iaum i i nnu i u na i i nun i inna i s iniu i i n ui i i sog 10-8
^
E W
g W
Q.
v ZO g
2 W
Og U
e ll31 toZ HQ W
W N
10-'
~
W O
~
~
o
( CS13 l
z yoO W
E La.
10-'
SR90 t 0-'
10-*
10-8 10-'
10' 10' 10 10 10*
10' 10' 10 8
8 7
(
CONCENTRATION CPIC0 CURIES PER LITER) 131 137 O
Figure 7 CCDF of 7,
Cs and Sr Concentrations in the Baxter Reservoir i
i
(
m..
e
i l
!l l'l Il l.
'x@$z$ OIn yxdwOHzt oozug7g HO vawg >w<mn o
F ig 1
1 1
1 1
1 u
0 0
0 0
0 0
r 4
7 e
0 4
1 Q
s
_r i
E 6
U e
i E
Ba C 1
n an C 0
i N
g sd D i
F C i
L 8
O i
A n 9 1
n N
s 0o N
n E
S f 0
q C
r E
e R
I N
i E
in T
n S
n s R
u 1
t E
t aA 0
g R
h nT i
V I
aO s
O e t i
I 1
n Q nN i
R g
0 u e e oC 1
i e uP i
n sI 1
1 n
I C
1 n
L C j
N a
O 0
1 S
a oC n nU i
T u
A e cR N
1 n
eI u
T nE 0 j
A
(
a t S i
N n r i
E d aP n
O 1
B i R 0 n
t E g
U a
S e o i
l nL i
C m
I i
n O
o oT i
u 1
E 0
e g
N n
s C
n f t
R i
E 1) s 3
?
i N
)
n T
R 1
I n
1 R
a I n
q 0
A s
w,
)
i i
T i
I
_m n
O W
1 n
a 3
1
_ _ __ y N
0 t
7 7
e C r s 4
e
(
10.0 D
5.0 R
X g
i 3.0 a
li 8
8 2.0 G
8 X
X 3
M i
1.0 i
XX
=
f x
l e
j 0.5 x
l E
j 0.3 l
0.2 l
0.1 1
1 i f I
I I i 1 1 I
i e
i e
i e i i 0.1 0.2 0.3 0.5 1.0 2.0 3.0 5.0 10.0 80Sr concentrations in tapwater (pCi//)
New York. City e
Figure 8. Correlation between %r concentrations in Schuylkill River water l
and New York City tapwater.
l l
4 10.0 5.0 3
j 3.0
]
x 8
2.0 h
f5o 8
X k
1.0 j
XX X
=
t 5
X XX g
0.5
.E E
2 R3 X
0 0.2 i!
I I
I I
I I
I I I I 0.1 I
I I I I
I I I I 0.1 0.2 0.3 0.5 2.0 3.0 5.0 10.0 New York City "Sr concentrations in tapwater (pCi//)
Figure 9. Correlation between # r concentrations in Delaware River water S
and New York City tapwater.
i
s PROFESSIONAL QUALIFICATIONS BART W. BARTRAM Manager, Radiological Programs Department NUS Corporation My name is Bart W. Bartram. My business address is 910 Clopper Road, Gaithersburg, Maryland 20878.
I am manager of the Radiological Programs Department.
In this position, I am responsible for the performance of radio-logical dose assessments and providing general consulting services in support of uranium fuel cycle facilities, including nuclear power plants, and other nuclear facilities.
I received a Bachelor of Science degree in Physics from Mount Union College in 1967, a Master of Science degree in Physics from the University of Washington in 1971, and a Master of Science degree in Mechanical Engineering from George Washington University in 1976.
From 1971 to 1972, I worked for the Custom Stack Analysis Company.
I conducted pilot plant studies used in the development of a new type of venturi scrubber and a lime wet scrubbing system for removing sulfur dioxide from the flue gases.
l I have been with NUS Corporation since 1972.
I was responsible for the noise impact analysis of nuclear and fossil-fueled power plants and other industrial facilities.
I performed background noise surveys, computer analysis of plant-contributed noise during evnstruction and operation, analysis of l
l alternative cooling system noise, analysis of transmission line electrical 1
effects, and noise impact assessments.
1 i
l
L
'~).
I am involved in licensing and permitting activities associated with uranium mining and milling operations, including the preparation of U.S.
Environmental Protection Agency (EPA) Prevention of Significant Deterioration permit applications, state air permit applications, source material license applications, and environmental reports.
In addition, I was responsible for preparir.g the radiological inputs to an environmental 1. pact statement for remedial actions on the Grand Junction and Rifle uranium mill tailings sites in response to the Uranium Mill Tailings Remedial Action Progran under contract to Sandia National Laboratories.
Other areas of work include radiological dose assessments of Savannah River Plant facilities and operations, high-level waste repositories, and risk assessments of fission-reactors and plutonium-fueled space nuclear systems.
2
AP i
-l 4
PROFESSIONAL QUALIFICATIONS CARMEN F. GUARINO President of Carmen F.-Guarino Engineers Ltd.
EDUCATION -
LaSalle College, B.A., Chemistry and Biology, Engineering and Related Courses at Drexel University, Temple University, Pennsylvania State College, Manhattan College PROFESSIONAL STA'IUS Registered Professional Engineer in Pennsylvania (By Exam.)
Diplomate, American Academy of Environmental Engineers Certified Sewage Treatment Operator, Class "A", Pennsylvania EXPERIENCE Employed by Philadelphia Water Department, 1950 to 1980. Held follow-ing positions; Chief Chemist, Water Pollution Control Plant; Superintendent, i
Northeast Water Pollution Control Plant; Superintendnet, Southeast and Southwest Water Pollution Control Plants; Assistant Chief, Water Pollution Control Plants (3); Chief, Water Pollution Control Division (Includes Water. Pollution Control Plants, Industrial Waste Control, Sewer Maintenance, and Administration).
January 1, 1968 - Assumed duties as Deputy Commissioner January 3,1972 - Appointed Commissioner of the Philadelphia Water Department. Appointment terminated January 7, 1980.
June 1, 1980 - Founded Carmen F. Guarino Engineers Ltd.
Presently serving as President.
January 1, 1981 - Technical Director of S.E.L.E.C.; a design con-struction firm in Turino, Italy.
PROFESSIONAL OFFICES l
Advisor to the Governor of Pennsylvania in his capacity as a Member i
of the Delaware River Basin Commission, 1972 to 1980.
Commissioner, Fairmount Park Commission, 1972 to 1980 Trustee-at-Large, American Academy of Environmental Engineers, 1979-1980.
l President, Engineers' Club of Philadelphia, 1979 Vice-President, Engineers' Club of Philadelphia, 1978 l
President, Water Pollution Control Federation, 1980-1981 President-Elect, Water Pollution Control Federation, 1979-1980 i
l 1
i l
y
[
Vice-President, Water Pollution Control Federation, 1978-1979 President, Water Pollution Control Association of Pennsylvania, 1968-1969 President, Eastern Pennsylvaria Water Pollution Control Operators Association, 1965 ASSOCIATIONS WATER POLLUTION CONTROL FEDERATION President, 1980-1981 President-Elect, 1979-1980 Vice-President, 1978-1979 vice-Chairman, Technical Practice Committee, 1977-1980 Chairman, National Conference, 1977 Chairman, Committee on Operation of Wastewater Treatment Plants, Manual of Practice No. 11, 1974 to 1978 Executive, Committee Member Board of Control Member Pennsylvania Director, 1971 WATER POLLUTION CONTROL ASSOCIATION OF PENNSYLVANIA President, 1968-1969 EASTERN PENNSYLVANIA WATER POLLUTION CONTROL OPERA'IORS ASSOCIATION s
President, 1965 AMERICAN SOCIETY OF CIVIL ENGINEERS Chairman, Water Pollution Management Committee, 1975-1976 Chairman, Urban Wastewater Engineering Committee, 1974 Representative to WPCF - Manforce Program, 1970 Committee on Sewerage and Sewage Treatment, 1968-1970 l
l Philadelphia Section:
Board of Directors, 1970 Secretary, 1965-1968 Chairman, Hydraulic and Sanitary Engineering Division, 1966 l
AMERICAN ACADEMY OF ENVIRONMENTAL ENGINEERS Trustee-at-Large, 1979-1980 Trustee-in-Charge, Committee on Upgrading Examinations-General Sanitary and Environmental, 1979 Trustee-in-Charge, Committee on Upgrading Examinations-Water Supply and Wastewater, 1979 2
d i
INTERNATIONAL ASSOCIATION OF WATER POLLUTION RESEARCH U.S. Chairman, " Instrumentation and Automation Workshop",
Munich / Rome, 1981 U.S. Chairman, " Instrumentation and Control of Water and Wastewater and Transport Systems Workshop", London /
Stockholm, 1977 U.S. Chairman, " Instrumentation and Automation Workshop",
London / Paris, 1973 ASSOCIATION OF METROPOLITAN SENERAGE AGENCIES Board of Directors, 1978 to 1980 Member, National Society of Professional Engineers Member, American Water Works Association Member, American Public Works Association Member, Instrument Society of American, Water and Wastewater Industries Division PROFESSIONAL ACTIVIITES Consulting Editoral Staff, Water & Sewage Works Journal, 1978-1982 Consulting Board Member, Milwaukee Water Pollution Abatement Program 1978 to 1980 Member, EPA-National Drinking Water Advisory Council, 1977-1979 Member, Mayor's Science and Technology Advisory Council, 1973 to 1980 Member, State Board of Certification of Sewage Treatment Plants and Water Works Operators Chairman, " Water Plant Instrumentation and Automation Seminar", American Water Works Association Annual Meeting, New Orleans, Louisiana, 1976 Consulting for World Health Organization / Plan American Heath Organization - Prepared Pollution Control Abatement Plans for Rio de Janeiro, Brazil, 1975 a 1976 Participant, United States / Republic of China, " Environmental Pollution l
Seminar", Sponsored by National Science Foundation and National Science l
Council, Taipei, Taiwan, 1974 Participant, Technical Symposium, " Pure Oxygen in Sewage Treatment",
i Sponsored by Union Carbide Company, London, England, 1973 l
l I
l 3
/
i Consultant for EPA, Region III, Review Land Disposal of Sludge Process, London, England (and Environs),1972 Consultant Work in Italy, Japan, Sweden, Switzerland and Africa AWARDS Simon W. Feese Lecture Award, American Society of Civil Engineers, 1979-1980 Morgan Award, Exemplary Inovative Treatment Technology, Water Pollution Control Federation, 1980 Instrument Society of America, Water and Wastewater Industries Division (Contributions to the Advancement of Automation l
Technology), 1978 George Washington Medal, Engineers' Club of Philadelphia, 1977 Haseltine Award, Pennsylvania Water Pollution Control Association (Outstanding Accomplishments in Solving Water Pollution Control Problems in Pennsylvania),1977 Rudolph Herring Award, American Society of Civil Engineers (Technology Contributions),1971 Arthur Sidney Bedell Award, Water Pollution Control Federation (Outstanding Service in the Field of Water Pollution Control and in the Operation of the Association), 1971 High Hat Award, Pennsylvania Water Pollution Control Association (Outstanding Service to the Water Pollution Control Profession),
1965 l
PAPERS AND PUBLICATIONS Over 80 technical papers on water pollution control, municipal and industrial waste treatment, instrumentation, management, treatment and disposal of sludge and other related subjects.
PATENTS i
Patent No. 685,723 issued June 6, 1978: Modification of Activated Sludge Process, r
i 4
l l
PROFESSIONAL QUALIFICATIONS ALAN L. IDBLIN Environmental Services Division NUS Corporation My name is Alan L. Toblin. My business address is 910 Clopper Road, Gaithersburg, Maryland 20878.
I am a consulting engineer in the Radiological Programs Department.
I received a Bachelor of Engineering degree in Chemical Engineering from the Cooper Union in 1968 and a Master of Science degree in Chemical Engineer-ing from the University of Maryland in 1970.
I have taken additional graduate courses in Chemical Engineering at the University of Maryland.
At NUS Corporation since 1971, I have performed analytical and develop-mental work on computer codes for many projects.
I have developed mathematical models of subsurface discharges of heated water in the presence of cross flows and physical boundaries in order to calculate the thermal and concentration distributions in the receiving water.
I developed a mathematical model and a computer code for calculating the dispersion from a continuous point source i
of radioactive material in an aquatic environment, and I performed analytical and developmental work on a computer code to calculate the thermal and con-I centration contours due to heated surface discharges.
I also worked on com-puter codes to calculate the ground-level deposition for the high altitude and low altitude release of particulates.
l l
l l
l l
1 l
l
I k
I coordinate efforts to meet water quality and quantity requirements for construction and operating licenses for power plants and other industrial facilities.
I also perform analyses of heated water discharges and cooling water intake velocities for power plants, and I analyze experimental proce-dures and results of operation of thermal-hydraulic modeling of heated water intakes and discharges.
Recent projects have included the development of a computer code and analyses of the groundwater transport of chemically reactive species; the development of a methodology and a computer code to model the sediment transport in a river due to bottom disturbance; and the development of a methodology and corresponding computer code for calculating the transient behavior of a closed-cycle cooling system including any arbitrary configuration i
of cooling ponds, spray canals, and cooling towers, under varying meteorologi-cal conditions.
I 2
l k
PROFESSIONAL QUALIFICATIONS ROBERT WALLER Director, Gaithersburg Office, PEC Division NUS Corporation My name is Robert Waller. My business address is 910 Clopper Road, Gaithersburg, Maryland 20878. I am Director of the Gaithersburg Regional Office of the PEC Division of NUS.
I received a Bachelor of Science degree in Chemical Engineering from Rensselaer Polytechnic Institute in 1958, a Master of Science degree in Environmental Engineering from Rensselaer in 1961, and a Doctor of Philosophy in Environmental Engineering Science from the John Hopkins University in 1966.
After receiving my Bachelor's degree, I worked for the New York State Department of Health in the Water Supply Section from 1958 to 1962. My primary responsibilities included the review and evaluation of the design and operation of new and existing water supply treatment plants throughout the New York State. Other areas of activity included the collection of data, evaluation of new water treatment techniques, establishment of emergency l
water supplies, and presentation of training courses.
From 1966 to 1969, I worked for E. I. du Pont de Nemours Company, Inc.
I was responsible for technical assistance on more than 60 different problems involving over 30 different plants that manufactured a wide variety of organic and inorganic chemicals, as well as explosives, plastics, ammunition, paints, and pesticides. I developed waste treatment facility designs, 1
1
t planned and directed waste characterization and pollution abatement programs for individual plants, provided assistance for resolution of treatment plant operational problems, and provided liaison with regulatory agencies.
Working for Hittman Associates, Inc., from 1969 to 1972, I was responsi-ble for all technical activities relating to water pollution control. These included industrial waste treatment consulting and process development, advanced waste treatment system development, planning and direction of governmental and industrial research and demonstration projects, and corporate research programs.
I made technical contributions to the following projects:
(1) environmental aspects of alternatives to the internal combus-tion engine, (2) alternative approaches to storm water management and erosion l
control, and (3) evaluation of the potential of desalting technology for meeting water resource needs.
l From 1972 to 1980, I had overall corporate responsibility for program management, operations, and production for Environmental Quality Systems, Inc.
I was project manager for more than 25 different projects and made significant technical and policy contributions to more than 20 other projects. Special areas of expertise included waste treatment process i
development and design, management of toxic and hazardous materials, process residue treatment and disposal, industrial waste treatment, emergency water and waste systems, areawide water quality planning, evaluation of emerging technology, control of non-point-source pollutants, and environmental impact analysis.
In addition, I was a special UNESCO Consultant to the Kingdom of l
t i
2
Morocco and a member of a National Science Foundation Inspection Team evalua-ting damages to the water and sewage systems of Sendai, Japan after a major earthquake.
Since joining NUS Corporation in 1980, I have been responsible for the management and technical direction of projects involving hazardous, indus-trial, and municipal wastes.
I act as principal-in-charge (PIC) on projects performed in the PEC Gaithersburg office as well as project manager on larger projects. Areas of responsibility include impact evaluation, problem defini-tion, technology assessment, planning, evaluation and design of remedial action alternatives, and program planning.
I managed a multidisciplined Public Works Group that completed over 40 facility planning and design assignments for government clients.
3