',6 4

! ntroy%,

i UNITED STATES E"

NUCLEAR REGULA. TORY COMMISSION n

,I WASHINGTON, D. C. 20555 f'

j/

OCT 2 01981

+

a MEMORANDUM FOR:

Emmet Murphy Jack Nehemias Tim Mo Pat Easely Charlie Miller Herb Conrad Bernard Turovlin Tom Kane t.

?

FROM:

Robert A. Clark, Chief Operating Reactors Branch #3, DL

SUBJECT:

POINT BEACH STEAM GENERATOR TUBE SLEEVING - DEMONSTRATION PROGRAM As the Point Beach Project Manager, Tim Colburn, discussed with you on the telephone last week, a hearing has been scheduled by the Atomic Safety and Licensing Board (ASLB) on the subject issue to be held in the Federal Building, Milwaukee, Wisconsin on the 29th, 30th and 'possibly 31st of October.

The ASLB has requested.that those NRC staff technical reviewers providing input for the Safety Evaluation Report (SER) be available to testify at the hearing in order to answer questions the ASLB might have regarding the SER.

You should make the appropriate arrangement in your schedules and plan to attend.

The attached information will be helpful to you in preparation of your travel requests. Enclosure 1 is information on the time and place of the hearing. is information on flights and hotel reservations made for myself and Tim Colburn by 0 ELD and is provided to assist you in making your travel arrangements. is a proposed hearing agenda.

If you have any questions or cannot be available to testify, please contact Tim Colburn ASAP on X29547.

n

... y f S

f6 C

l Robert A. Clark, Chief Operating Reactors, Branch #3 Division of Licensing

Enclosures:

As stated t

I cc:

D. Eisenhut V. Benaroya l

T. Novak W. Kreger S. Treby W. Gammill R. Blockman R. Houston R. Ballard D. Muller S. Pawlicki W. Johns F. Congel gf

/ *

]lDF Q

o. t h q

k, UfJITED ST'ATES

'. e.s t'(( %

NUCLEAR REGULATORY COMMISSION

.- x*.. c ATOf/.lC SAFETY AftD LICEf4SitJG BOARD PAf4EL n.

n

$,'gQh l.

4

,, '*jsHINGToN,D.C.205ss REQUEST TOR RIPORTING SERVICE"'

o,,..

Work Order No. ARC-IB-70

+

.1.

tot 1

Wis'consin Electric Power co.

facesding:

Point Beach Nuclear Plant, Units 1 & 2' 50-266-OLA Docket No. (s) sin-301-OLA

.4 U.S. District Court Location of:'.? rehearing Federal ~ Building

  • Key to c6 pit room in m 3-

~

u.d. t ax t,ourt. Koom p.w

.17 E. Wisconsin Av.enue 5

haswauAct, H i st.ulls lli Hearing OLA i.

e..

, e.-.

m o

es e

e

.*s

=

e e.

ss.

e

  • i.'.

1.'.

=

Phone: (414)291-3 Patrick DeWane

?IRSOh TO C0hTACT AT HEARING LOCATION Deputy Clerk of the Court IT :5 30 S DE.ED.

eti=ated Duration:

? rehearing Hearing -

-3 Meeting _,

(WeesL N s 4 % diacM J slw*~M kn +;M.)

li t e 10/29,. 3.0 I 31

? rehearing Ecaring x

xeeting l.ernate 11/5 & 6 h=2 of: 9:3D---

? rehearing Eearing Meeting X

l l

9.NSCRIPT SERVICE REQUIRED:

? rehearing

i. r,

' - ~ ' '

Hearing Next day copies go to place of hearinq live c>:act r.u=ber of copies r Board, Staff (ELD) or Meeting 2nd & 3^ hay c pies to Anita McNamara lthers & vhen & uhere.to 4350 East ' West M1ghway' lo delivered.

. Bethesda, MD b all "I'n Camera" Hearings, (original copies go to Anita McNamara)

I copias for Soard, 2 copies ELD, 3 copies to Board and 2 to Staff sd 1 criginal are required.

Peter B. Bloch Me=bers Jerry R. Kline / Huch C. Paxton/_

$ard Chair =an hpo of Proceeding:

Evidentiary 128 epies of. transcript may (--f e) be sold.

Begin pagination of transcript with 1

ate of or:1 recuest to Reporting Co. and e se. cc.tacted.

Date Contactf bte ef written confirmation fg

[

cc-PBloch Fouchard ASLSP P. Kreutzer pe=icSafety&Licensingsoard?anel

q Flight and Hotel Reservations for Milwaukee, Wisconsin...

4

.be Hotel Accommodations-Park East Hotel 916 East Stite Street Milwaukee, Wisconsin 53202 (414)276-8800 Rese'rvations have been made at the hotel for members of OELD staff and T.' G. Colburn and R.-A. -CJark of Operating Reactors Branch #3. The hotel is located approximately 7 blocks from the hearing site. The cost is consistent with the per diem rate for this area.

Flights

~

Northwest Airlines flight'375 departs National Airport at 3:30 PM on.

October 28,.1981.

It arrives in Milwaukee, Wisconsin at 5:12 PM:. local

~

time.

Return flight number is United Airlines flight No. UA 1058 leaving Milwaukee,-

Wisconsin on October 30, 1981 at 4:45 PM and arriving at Cleveland at 6:48 PM. Transfer to United Airlines flight UA 1038 departing at 7:35 PM and arriving at National Airport at 8:36 PM.

% 6 @

O e

e 9

4 O

H en e

9 e

--~

  • h UNITED STATES OF AMERICA Z

gggM NUCLEAR REGULATORY C0FNISSION fynwee[k"~'*

~

ATOMIC SAFETY AND LICENSING BOARD n2 Before Administrative Judges':

8 Peter B. Bloch, Chairman Jerry R. Kline

- T.]

Hugh C." Paxton

)-

WISCONSIN ELECTRIC POWER COMPANY

)

Docket Nos. 50-266-OLA

)

50-301-OLA (Point Beach Nuclear Plant,

)

Units 1 and 2)

). October 15, 1981

)

MEMORANDUM AND ORDER SETTING AGENDA AND RULES FOR OCTOBER 29-30 HEARING Subject to change by motion of a party, the agenda for the 9:30 am, October 29-30, 1981, combined hearing will be:

~

'I A show cause hearing concerning Wisconsin. Electric Power Company's

~

(WE) motion to obtain interiin relief so that it.can operate its

[

power reactor with up to six deteriorated. steam generator tubes sleeved rather than plugged.

II Additional argument, if any, concerning WE's motion for sumary judgment.

(However, the Board is inclind to rule that at this stage of a proceeding, when discovery has.not yet been completed, that the standards for sumary judgment are the standards'already articulated with respect to the show cause order.)

III If.~necessary, to conduct a limited ~ videntiary hearing for the e

. purpose of helping' to resolve.the-.show cause or sumary judgment motions.

IV If necessary and helpful, to con' duct 'an evidentiary hearing on unresolved issues of material fact.

The parties are required to exchange a witness list and documents that will be relied on at the hearing at least 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the hearing, unles's they have good cause for being unable to do so with respect w

/

jfh a

nr fv

c.

?;

i e

October 29 Agenda:

2 r.

to particular witnesses or documents. The witness list should include a curriculum vita (including principal publications) for each witness and a.

reasonably complete ' statement of the particular safety or environmental aspects of the sleeving project that will be of concern to each witness.

In addition, parties may file briefs-(including WE's response to intervenor's' brief attempting to show good cause for blocking._the, demons,tration program);.

a up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to the hearing.

l.

Due to the tight time schedule within whic.h blisco'nsin's~ Environmental --

Decade must work,- WE-may conduct -discovery only to the extent that Decade agrees that the scope of the requested discovery will not unduly interfere

~

with it in the preparation of its case.

~

~

~ ~ ~ ~

Parties are advised to be prepared for night sessions and, possibly,.

In addition, a Sa'turday sess. ion if required for the completion of business;-.....

, arties are advised that the hearing may be recony'ened on November 6 and 7...

p

~

'if necessary.

IT,IS 50 ORDERED..

FOR THE

~

ATOMIC SAFETY AND LICENSING BOARD

[,

1 Feter B." Bloch, Chairman ADMINISTRATIVE JUDGE l

October 15, 1981 Bethesda, Maryland S

O g

L

_