ML20071H971
| ML20071H971 | |
| Person / Time | |
|---|---|
| Site: | 05000000, Ginna |
| Issue date: | 02/16/1982 |
| From: | Lyons J Office of Nuclear Reactor Regulation |
| To: | Carter J, Harold Denton, Eisenhut D NRC |
| Shared Package | |
| ML19302F297 | List:
|
| References | |
| FOIA-82-309 NUDOCS 8203110339 | |
| Download: ML20071H971 (2) | |
Text
s s
%,o,,
C.
C t:
UNITED STATES NUCLEAR REGULATORY COMMISSION e
o 3
WASHINGTON, D. C. 20555 e.
5
/
V*=O%*/
February 16, 1982 c
MEMORANDUM FOR:
H. Denton J. Carter D. Eisenhut R. Purple T. Novak R. Tedesco G. Lainas S. Hanauer R. Vollmer R. Mattson H. Thompson J. Sniezek T. Ippolito J. La Fleur
+
THRU:
Dennis M. Crutchfield, Chief Operating Reactors Branch #5, DL
~
FROM:
James E. Lyons, Project Manager Operating Reactors Branch #5, DL
SUBJECT:
DAILY HIGHLIGHT R. E. GINNA.
Rochester Gas and Electric Corporation (RG&E) has completed a television (TV) inspection of the periphery of the "B" steam generator (S/G) hot leg.
Inspection results indicate approximately 7-10 previously plugged tubes in the peripheral area near the ruptured tube are severly damaged. At least i
two tubes appear to have been completely severed 1-2 inches above t.se. tube l
sheet.
The remaining damaged tubes in this area appear to have been heavily I.
impacted at the same elevation, with penetrations and siignificant dents i
visible. Two pieces of foreign metal have be~eli removed from the steam generator.
The larger, approximately 6:1/2" x 4" x 7/16", was found in an area approx-imately 8 to 10 feet from the ruptured tube. 8 to 10 previously plugged tubes in this area were' scarred and dented to a lesser degree than those in the area of the rupture.
RG&E plans to perfom further TV inspections of the "B" S/G (cold leg periphery and hot leg tube lane) and to perfom the same I
inspection of the "A" S/G. Westinghouse specialists arrived on-site today to provide techhical assistance.
RG&E will continue "tYevaluate the res~ lts of the inspections.
u
- h. f.
W hy Jam s E. Ly roject Manager.
'ating Re s Branch #5 a
[l0 y
Division of Licensing
.ff 1
.