February 12, 1982 MEMORANDUM FOR:
H. Denton J. Carter D. Eisenhut R.' Purple T. Novak.
R. Tedesco G. Lainas S. Hanauer R. Vollmer R. Mattson H. Thompson J. Sniezek T. Ippolito C. Hel.temes, AEOD J. La Fleur:-
THRU:
Dennis M. Crutchfield, Chidf Operating Reactors Branch #5,'DL FROM:
James E. Lyons, Project Manager Operating Reactors Branch #5, DL
SUBJECT:
DAILY HIGHLIGHT R. E. GINNA Fiber optic investigation of the secondary side of the "B" steam generator (S/G) has revealed that there is damage to previously plugged tubes in' wedge area #4 where the ruptured tube is located.
Preliminary indications are that one tube is totally severed and several other tubes in the vicinity are severely damaged. RG&E will continue to investigate the peripheral area of the "B" S/G with improved fiber optics and. television cameras as they are j
available. A S/G team from Westinghouse is expected to be on-site tonight.
RG&E is considering a number of options, including cutting a hole in the side of "B" S/G to gain ' ccess to wedge area #4 Rochester Gas and Electric a
Corporation (RG&E) nas informed the NRC that the meeting previously anned for next week on restart requirements has been cancelled.
?.E.
l James E. L n, Project Manager p.
rating Rea t. ors Branch #5 l
Division of Licensing l
l pf4
.. -.