IR 05000440/1982004
ML20054F553 | |
Person / Time | |
---|---|
Site: | Perry |
Issue date: | 05/31/1982 |
From: | Gildner M, Konklin J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
To: | |
Shared Package | |
ML20054F549 | List: |
References | |
50-440-82-04, 50-440-82-4, 50-441-82-04, 50-441-82-4, NUDOCS 8206170095 | |
Download: ML20054F553 (4) | |
Similar Documents at Perry | |
---|---|
Category:INSPECTION REPORT
MONTHYEARIR 05000440/19990131999-09-13013 September 1999
[Table view]Insp Rept 50-440/99-13 on 990712-30.Violations Noted. Major Areas Inspected:Effectiveness of Pnpp Program for Identification,Resolution & Prevention of Technical Issues & Problems That Could Degrade Quality of Plant Operations IR 05000440/19990091999-09-0909 September 1999 Insp Rept 50-440/99-09 on 990709-0825.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20211M6521999-08-31031 August 1999 Revised Page Number 4, P2 Status of EP Facilities,Equipment & Resources IR 05000440/19990121999-08-12012 August 1999 Insp Rept 50-440/99-12 on 990712-16.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program IR 05000440/19990081999-07-22022 July 1999 Insp Rept 50-440/99-08 on 990518-0708.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000440/19990031999-06-10010 June 1999 Insp Rept 50-440/99-03 on 990407-0517.Two Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000440/19990071999-05-12012 May 1999 Insp Rept 50-440/99-07 on 990412-16.No Violations Noted. Major Areas Inspected:Rp Performance & Oversight of Refueling Outage Activities IR 05000440/19990061999-05-0606 May 1999 Insp Rept 50-440/99-06 on 990303-04 & 0412-16.No Violations Noted.Major Areas Inspected:Inservice Insp Efforts & Overlay Repairs of N4C Feedwater Nozzle IR 05000440/19990021999-05-0303 May 1999 Insp Rept 50-440/99-02 on 990225-0406.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000440/19990051999-04-0202 April 1999 Insp Rept 50-440/99-05 on 990301-05.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Npps ML20204E7901999-03-17017 March 1999 Insp Rept 50-440/99-01 on 990113-0224.Non-cited Violation Identified.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19990041999-03-17017 March 1999 Insp Rept 50-440/99-04 on 990222-26.No Violations Noted. Major Areas Inspected:Radiation Protection Program & Radiological Planning for Upcoming Refueling Outage,Which Included Review of Rwps,Alara Reviews & Dose Goals IR 05000440/19980191998-12-23023 December 1998 Insp Rept 50-440/98-19 on 981021-1202.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000440/19980221998-11-25025 November 1998 Chemistry & RP Insp Rept 50-440/98-22 on 981102-06.No Violations Noted:Major Areas Inspected:Implementation of Chemistry Program,Meteorological Monitoring Program & Control & Monitoring of Personnel Radiation Dose IR 05000440/19980211998-11-18018 November 1998 Insp Rept 50-440/98-21 on 981019-22.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20195C7361998-11-10010 November 1998 Insp Rept 50-440/98-18 on 980909-1020.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980171998-10-0707 October 1998 Insp Rept 50-440/98-17 on 980831-0914.Violations Noted. Major Areas Inspected:Review of Implementation of Solid Radwaste Mgt & Shipping Program.Insp Also Reviewed Conduct of Radiological Environ Monitoring Program IR 05000440/19980161998-09-25025 September 1998 Insp Rept 50-440/98-16 on 980723-0908.No Violations Noted. Major Areas Inspected:Resident Inspectors Evaluation of Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19980151998-09-0808 September 1998 Insp Rept 50-440/98-15 on 980727-31.Violations Noted. Major Areas Inspected:Effectiveness of Selected Elements of Security Program IR 05000440/19980131998-08-21021 August 1998 Insp Rept 50-440/98-13 on 980605-0722.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980141998-08-19019 August 1998 Insp Rept 50-440/98-14 on 980620-24 & 0720-22.No Violations Noted.Major Areas Inspected:Licensee C/A for Issues Identified by NRC Inspections & Licensee Event Repts Submitted to NRC ML20236R8251998-07-16016 July 1998 Insp Rept 50-440/98-11 on 980518-22.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures, Training,Equipment & Supporting Documentation for Maint of medium-voltage & low-voltage Power Circuit Breakers ML20236N0281998-07-0909 July 1998 Insp Rept 50-440/98-10 on 980421-0604.Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support IR 05000440/19980121998-06-25025 June 1998 Insp Rept 50-440/98-12 on 980601-05.Violations Noted.Major Areas Inspected:Plant Support ML20217M1311998-04-29029 April 1998 Insp Rept 50-440/98-07 on 980223-0305.Violations Noted. Major Areas Inspected:Operations,Engineering & Maintenance IR 05000440/19980051998-04-27027 April 1998 Insp Rept 50-440/98-05 on 980209-0408.No Violations Noted. Major Areas Inspected:Portions of Licensee Fire Protection Program IR 05000440/19980061998-04-0101 April 1998 Insp Rept 50-440/98-06 on 980128-0310.Violations Noted.Major Areas Inspected:Licensee Operations,Maint & Engineering IR 05000440/19980031998-03-26026 March 1998 Insp Rept 50-440/98-03 on 980223-27.No Violations Noted. Major Areas Inspected:Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000440/19980021998-03-12012 March 1998 Insp Rept 50-440/98-02 on 980112-16 & 26-30.No Violations Noted.Major Areas Inspected:Operations,Engineering & Review of Effectiveness of CA Program ML20203D8241998-02-20020 February 1998 Insp Rept 50-440/97-21 on 971202-980127.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000440/19970171998-01-21021 January 1998 Insp Rept 50-440/97-17 on 971103-07 & 971215-18.No Violations Noted.Major Areas Inspected:Ep Program IR 05000440/19980041998-01-16016 January 1998 Insp Rept 50-440/98-04 on 980105-09.No Violations Noted. Major Areas Inspected:Radiolological,Environ & Chemistry Sections Programs IR 05000440/19970201998-01-12012 January 1998 Insp Rept 50-440/97-20 on 971202-05.No Violations Noted. Major Areas Inspected:Review of Physical Security Program ML20202J1301998-01-0202 January 1998 Insp Rept 50-440/97-16 on 971004-1201.Violations Noted. Major Areas Inspected:Operations,Maint & Plant Support IR 05000440/19970221997-12-31031 December 1997 Insp Rept 50-440/97-22 on 971015-1201.Violations Noted. Major Areas Inspected:Circumstances That Led to Inadvertent Loss of Reactor Pressure Vessel Water Inventory That Occured on 971011 IR 05000440/19970151997-12-21021 December 1997 Insp Rept 50-440/97-15 on 970922-1023.No Violations Noted. Major Areas Inspected:Isi Efforts & Installation Activities of Suppression Pool Suction Strainer Mod IR 05000440/19970091997-11-26026 November 1997 Insp Rept 50-440/97-09 on 970624-0808.Violations Noted. Major Areas Inspected:Operations,Maintenance & Surveillance, Engineering & Plant Support IR 05000440/19970121997-11-26026 November 1997 Insp Rept 50-440/97-12 on 970809-1004.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19970191997-11-25025 November 1997 Insp Rept 50-440/97-19 on 971027-31.No Violations Noted. Major Areas Inspected:Radiological Controls,Radwaste Controls,Radiation Worker Practices & High Radiation Area Controls IR 05000440/19970071997-10-24024 October 1997 Insp Rept 50-440/97-07 on 970503-0623.Violations Noted. Major Areas Inspected:Operations,Maintenance,Surveillance, Engineering & Plant Support IR 05000440/19970141997-10-17017 October 1997 Insp Rept 50-440/97-14 on 970915-19.No Viiolations Noted. Major Areas Inspected:Review of Radiation Protection Program,Including Radiation Protection Planning & Coverage for Sixth Refueling Outage ML20212A3721997-10-16016 October 1997 Predecisional Enforcement Conference Rept on 971007.Areas Discussed:Apparent Violations Identified During Insp & CA Taken or Planned by Licensee.Apparent Violations Involved SE That Failed to Identify Unreviewed Safety Question IR 05000440/19970131997-09-29029 September 1997 Insp Rept 50-440/97-13 on 970826-28.No Violations Noted. Major Areas Inspected:Followup to Maintenance Rule Baseline Insp ML20198L5241997-09-23023 September 1997 Insp Rept 50-440/97-08 on 970721-0827.Violations Noted. Major Areas Inspected:Unresolved Items & Insp follow-up Items Identified by Design Insp Conducted from 970127-0327 IR 05000440/19970101997-08-29029 August 1997 Insp Rept 50-440/97-10 on 970728-0801.Violations Noted. Major Areas Inspected:Review of Solid Radioactive Waste Processing & Shipping Program.Additionally,Radiation Protection Planning for Upcoming Refueling Outage Reviewed IR 05000440/19970111997-08-26026 August 1997 Insp Rept 50-440/97-11 on 970728-31.No Violations Noted. Major Areas Inspected:Licensee Fire Protection Program IR 05000440/19960161997-08-0404 August 1997 Predecisional Enforcement Conference Rept on 970418.Areas Discussed:Violations Noted in Insp Repts 50-440/96-16, 50-440/96-17 & 50-440/96-18 & Corrective Actions IR 05000440/19970041997-06-16016 June 1997 Insp Rept 50-440/97-04 on 970322-0502.No Violations Noted. Major Areas Inspected:Operation,Maint & Surveillance, Engineering & Plant Support ML20140F8371997-06-10010 June 1997 Insp Rept 50-440/97-201 on 970217-0327.Issues Identified Which Challenged Capability of Sys to Perform Complete Scope DBA Mitigation Actions.Major Areas Inspected:Hpcs & Eec Sys IR 05000440/19972011997-06-10010 June 1997 Insp Rept 50-440/97-201 on 970217-0327.Issues Identified Which Challenged Capability of Sys to Perform Complete Scope DBA Mitigation Actions.Major Areas Inspected:Hpcs & Eec Sys 1999-09-09 Category:NRC-GENERATED MONTHYEARIR 05000440/19990131999-09-13013 September 1999
[Table view]Insp Rept 50-440/99-13 on 990712-30.Violations Noted. Major Areas Inspected:Effectiveness of Pnpp Program for Identification,Resolution & Prevention of Technical Issues & Problems That Could Degrade Quality of Plant Operations IR 05000440/19990091999-09-0909 September 1999 Insp Rept 50-440/99-09 on 990709-0825.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20211M6521999-08-31031 August 1999 Revised Page Number 4, P2 Status of EP Facilities,Equipment & Resources IR 05000440/19990121999-08-12012 August 1999 Insp Rept 50-440/99-12 on 990712-16.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program IR 05000440/19990081999-07-22022 July 1999 Insp Rept 50-440/99-08 on 990518-0708.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000440/19990031999-06-10010 June 1999 Insp Rept 50-440/99-03 on 990407-0517.Two Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000440/19990071999-05-12012 May 1999 Insp Rept 50-440/99-07 on 990412-16.No Violations Noted. Major Areas Inspected:Rp Performance & Oversight of Refueling Outage Activities IR 05000440/19990061999-05-0606 May 1999 Insp Rept 50-440/99-06 on 990303-04 & 0412-16.No Violations Noted.Major Areas Inspected:Inservice Insp Efforts & Overlay Repairs of N4C Feedwater Nozzle IR 05000440/19990021999-05-0303 May 1999 Insp Rept 50-440/99-02 on 990225-0406.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000440/19990051999-04-0202 April 1999 Insp Rept 50-440/99-05 on 990301-05.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Npps ML20204E7901999-03-17017 March 1999 Insp Rept 50-440/99-01 on 990113-0224.Non-cited Violation Identified.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19990041999-03-17017 March 1999 Insp Rept 50-440/99-04 on 990222-26.No Violations Noted. Major Areas Inspected:Radiation Protection Program & Radiological Planning for Upcoming Refueling Outage,Which Included Review of Rwps,Alara Reviews & Dose Goals IR 05000440/19980191998-12-23023 December 1998 Insp Rept 50-440/98-19 on 981021-1202.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000440/19980221998-11-25025 November 1998 Chemistry & RP Insp Rept 50-440/98-22 on 981102-06.No Violations Noted:Major Areas Inspected:Implementation of Chemistry Program,Meteorological Monitoring Program & Control & Monitoring of Personnel Radiation Dose IR 05000440/19980211998-11-18018 November 1998 Insp Rept 50-440/98-21 on 981019-22.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20195C7361998-11-10010 November 1998 Insp Rept 50-440/98-18 on 980909-1020.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980171998-10-0707 October 1998 Insp Rept 50-440/98-17 on 980831-0914.Violations Noted. Major Areas Inspected:Review of Implementation of Solid Radwaste Mgt & Shipping Program.Insp Also Reviewed Conduct of Radiological Environ Monitoring Program IR 05000440/19980161998-09-25025 September 1998 Insp Rept 50-440/98-16 on 980723-0908.No Violations Noted. Major Areas Inspected:Resident Inspectors Evaluation of Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19980151998-09-0808 September 1998 Insp Rept 50-440/98-15 on 980727-31.Violations Noted. Major Areas Inspected:Effectiveness of Selected Elements of Security Program IR 05000440/19980131998-08-21021 August 1998 Insp Rept 50-440/98-13 on 980605-0722.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980141998-08-19019 August 1998 Insp Rept 50-440/98-14 on 980620-24 & 0720-22.No Violations Noted.Major Areas Inspected:Licensee C/A for Issues Identified by NRC Inspections & Licensee Event Repts Submitted to NRC ML20236R8251998-07-16016 July 1998 Insp Rept 50-440/98-11 on 980518-22.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures, Training,Equipment & Supporting Documentation for Maint of medium-voltage & low-voltage Power Circuit Breakers ML20236N0281998-07-0909 July 1998 Insp Rept 50-440/98-10 on 980421-0604.Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support IR 05000440/19980121998-06-25025 June 1998 Insp Rept 50-440/98-12 on 980601-05.Violations Noted.Major Areas Inspected:Plant Support ML20217M1311998-04-29029 April 1998 Insp Rept 50-440/98-07 on 980223-0305.Violations Noted. Major Areas Inspected:Operations,Engineering & Maintenance IR 05000440/19980051998-04-27027 April 1998 Insp Rept 50-440/98-05 on 980209-0408.No Violations Noted. Major Areas Inspected:Portions of Licensee Fire Protection Program IR 05000440/19980061998-04-0101 April 1998 Insp Rept 50-440/98-06 on 980128-0310.Violations Noted.Major Areas Inspected:Licensee Operations,Maint & Engineering IR 05000440/19980031998-03-26026 March 1998 Insp Rept 50-440/98-03 on 980223-27.No Violations Noted. Major Areas Inspected:Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000440/19980021998-03-12012 March 1998 Insp Rept 50-440/98-02 on 980112-16 & 26-30.No Violations Noted.Major Areas Inspected:Operations,Engineering & Review of Effectiveness of CA Program ML20203D8241998-02-20020 February 1998 Insp Rept 50-440/97-21 on 971202-980127.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000440/19970171998-01-21021 January 1998 Insp Rept 50-440/97-17 on 971103-07 & 971215-18.No Violations Noted.Major Areas Inspected:Ep Program IR 05000440/19980041998-01-16016 January 1998 Insp Rept 50-440/98-04 on 980105-09.No Violations Noted. Major Areas Inspected:Radiolological,Environ & Chemistry Sections Programs IR 05000440/19970201998-01-12012 January 1998 Insp Rept 50-440/97-20 on 971202-05.No Violations Noted. Major Areas Inspected:Review of Physical Security Program ML20202J1301998-01-0202 January 1998 Insp Rept 50-440/97-16 on 971004-1201.Violations Noted. Major Areas Inspected:Operations,Maint & Plant Support IR 05000440/19970221997-12-31031 December 1997 Insp Rept 50-440/97-22 on 971015-1201.Violations Noted. Major Areas Inspected:Circumstances That Led to Inadvertent Loss of Reactor Pressure Vessel Water Inventory That Occured on 971011 IR 05000440/19970151997-12-21021 December 1997 Insp Rept 50-440/97-15 on 970922-1023.No Violations Noted. Major Areas Inspected:Isi Efforts & Installation Activities of Suppression Pool Suction Strainer Mod IR 05000440/19970091997-11-26026 November 1997 Insp Rept 50-440/97-09 on 970624-0808.Violations Noted. Major Areas Inspected:Operations,Maintenance & Surveillance, Engineering & Plant Support IR 05000440/19970121997-11-26026 November 1997 Insp Rept 50-440/97-12 on 970809-1004.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19970191997-11-25025 November 1997 Insp Rept 50-440/97-19 on 971027-31.No Violations Noted. Major Areas Inspected:Radiological Controls,Radwaste Controls,Radiation Worker Practices & High Radiation Area Controls IR 05000440/19970071997-10-24024 October 1997 Insp Rept 50-440/97-07 on 970503-0623.Violations Noted. Major Areas Inspected:Operations,Maintenance,Surveillance, Engineering & Plant Support IR 05000440/19970141997-10-17017 October 1997 Insp Rept 50-440/97-14 on 970915-19.No Viiolations Noted. Major Areas Inspected:Review of Radiation Protection Program,Including Radiation Protection Planning & Coverage for Sixth Refueling Outage ML20212A3721997-10-16016 October 1997 Predecisional Enforcement Conference Rept on 971007.Areas Discussed:Apparent Violations Identified During Insp & CA Taken or Planned by Licensee.Apparent Violations Involved SE That Failed to Identify Unreviewed Safety Question IR 05000440/19970131997-09-29029 September 1997 Insp Rept 50-440/97-13 on 970826-28.No Violations Noted. Major Areas Inspected:Followup to Maintenance Rule Baseline Insp ML20198L5241997-09-23023 September 1997 Insp Rept 50-440/97-08 on 970721-0827.Violations Noted. Major Areas Inspected:Unresolved Items & Insp follow-up Items Identified by Design Insp Conducted from 970127-0327 IR 05000440/19970101997-08-29029 August 1997 Insp Rept 50-440/97-10 on 970728-0801.Violations Noted. Major Areas Inspected:Review of Solid Radioactive Waste Processing & Shipping Program.Additionally,Radiation Protection Planning for Upcoming Refueling Outage Reviewed IR 05000440/19970111997-08-26026 August 1997 Insp Rept 50-440/97-11 on 970728-31.No Violations Noted. Major Areas Inspected:Licensee Fire Protection Program IR 05000440/19960161997-08-0404 August 1997 Predecisional Enforcement Conference Rept on 970418.Areas Discussed:Violations Noted in Insp Repts 50-440/96-16, 50-440/96-17 & 50-440/96-18 & Corrective Actions IR 05000440/19970041997-06-16016 June 1997 Insp Rept 50-440/97-04 on 970322-0502.No Violations Noted. Major Areas Inspected:Operation,Maint & Surveillance, Engineering & Plant Support ML20140F8371997-06-10010 June 1997 Insp Rept 50-440/97-201 on 970217-0327.Issues Identified Which Challenged Capability of Sys to Perform Complete Scope DBA Mitigation Actions.Major Areas Inspected:Hpcs & Eec Sys IR 05000440/19972011997-06-10010 June 1997 Insp Rept 50-440/97-201 on 970217-0327.Issues Identified Which Challenged Capability of Sys to Perform Complete Scope DBA Mitigation Actions.Major Areas Inspected:Hpcs & Eec Sys 1999-09-09 Category:INSPECTION REPORT MONTHYEARIR 05000440/19990131999-09-13013 September 1999
[Table view]Insp Rept 50-440/99-13 on 990712-30.Violations Noted. Major Areas Inspected:Effectiveness of Pnpp Program for Identification,Resolution & Prevention of Technical Issues & Problems That Could Degrade Quality of Plant Operations IR 05000440/19990091999-09-0909 September 1999 Insp Rept 50-440/99-09 on 990709-0825.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20211M6521999-08-31031 August 1999 Revised Page Number 4, P2 Status of EP Facilities,Equipment & Resources IR 05000440/19990121999-08-12012 August 1999 Insp Rept 50-440/99-12 on 990712-16.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program IR 05000440/19990081999-07-22022 July 1999 Insp Rept 50-440/99-08 on 990518-0708.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000440/19990031999-06-10010 June 1999 Insp Rept 50-440/99-03 on 990407-0517.Two Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000440/19990071999-05-12012 May 1999 Insp Rept 50-440/99-07 on 990412-16.No Violations Noted. Major Areas Inspected:Rp Performance & Oversight of Refueling Outage Activities IR 05000440/19990061999-05-0606 May 1999 Insp Rept 50-440/99-06 on 990303-04 & 0412-16.No Violations Noted.Major Areas Inspected:Inservice Insp Efforts & Overlay Repairs of N4C Feedwater Nozzle IR 05000440/19990021999-05-0303 May 1999 Insp Rept 50-440/99-02 on 990225-0406.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000440/19990051999-04-0202 April 1999 Insp Rept 50-440/99-05 on 990301-05.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Npps ML20204E7901999-03-17017 March 1999 Insp Rept 50-440/99-01 on 990113-0224.Non-cited Violation Identified.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19990041999-03-17017 March 1999 Insp Rept 50-440/99-04 on 990222-26.No Violations Noted. Major Areas Inspected:Radiation Protection Program & Radiological Planning for Upcoming Refueling Outage,Which Included Review of Rwps,Alara Reviews & Dose Goals IR 05000440/19980191998-12-23023 December 1998 Insp Rept 50-440/98-19 on 981021-1202.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000440/19980221998-11-25025 November 1998 Chemistry & RP Insp Rept 50-440/98-22 on 981102-06.No Violations Noted:Major Areas Inspected:Implementation of Chemistry Program,Meteorological Monitoring Program & Control & Monitoring of Personnel Radiation Dose IR 05000440/19980211998-11-18018 November 1998 Insp Rept 50-440/98-21 on 981019-22.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20195C7361998-11-10010 November 1998 Insp Rept 50-440/98-18 on 980909-1020.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980171998-10-0707 October 1998 Insp Rept 50-440/98-17 on 980831-0914.Violations Noted. Major Areas Inspected:Review of Implementation of Solid Radwaste Mgt & Shipping Program.Insp Also Reviewed Conduct of Radiological Environ Monitoring Program IR 05000440/19980161998-09-25025 September 1998 Insp Rept 50-440/98-16 on 980723-0908.No Violations Noted. Major Areas Inspected:Resident Inspectors Evaluation of Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19980151998-09-0808 September 1998 Insp Rept 50-440/98-15 on 980727-31.Violations Noted. Major Areas Inspected:Effectiveness of Selected Elements of Security Program IR 05000440/19980131998-08-21021 August 1998 Insp Rept 50-440/98-13 on 980605-0722.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980141998-08-19019 August 1998 Insp Rept 50-440/98-14 on 980620-24 & 0720-22.No Violations Noted.Major Areas Inspected:Licensee C/A for Issues Identified by NRC Inspections & Licensee Event Repts Submitted to NRC ML20236R8251998-07-16016 July 1998 Insp Rept 50-440/98-11 on 980518-22.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures, Training,Equipment & Supporting Documentation for Maint of medium-voltage & low-voltage Power Circuit Breakers ML20236N0281998-07-0909 July 1998 Insp Rept 50-440/98-10 on 980421-0604.Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support IR 05000440/19980121998-06-25025 June 1998 Insp Rept 50-440/98-12 on 980601-05.Violations Noted.Major Areas Inspected:Plant Support ML20217M1311998-04-29029 April 1998 Insp Rept 50-440/98-07 on 980223-0305.Violations Noted. Major Areas Inspected:Operations,Engineering & Maintenance IR 05000440/19980051998-04-27027 April 1998 Insp Rept 50-440/98-05 on 980209-0408.No Violations Noted. Major Areas Inspected:Portions of Licensee Fire Protection Program IR 05000440/19980061998-04-0101 April 1998 Insp Rept 50-440/98-06 on 980128-0310.Violations Noted.Major Areas Inspected:Licensee Operations,Maint & Engineering IR 05000440/19980031998-03-26026 March 1998 Insp Rept 50-440/98-03 on 980223-27.No Violations Noted. Major Areas Inspected:Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000440/19980021998-03-12012 March 1998 Insp Rept 50-440/98-02 on 980112-16 & 26-30.No Violations Noted.Major Areas Inspected:Operations,Engineering & Review of Effectiveness of CA Program ML20203D8241998-02-20020 February 1998 Insp Rept 50-440/97-21 on 971202-980127.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000440/19970171998-01-21021 January 1998 Insp Rept 50-440/97-17 on 971103-07 & 971215-18.No Violations Noted.Major Areas Inspected:Ep Program IR 05000440/19980041998-01-16016 January 1998 Insp Rept 50-440/98-04 on 980105-09.No Violations Noted. Major Areas Inspected:Radiolological,Environ & Chemistry Sections Programs IR 05000440/19970201998-01-12012 January 1998 Insp Rept 50-440/97-20 on 971202-05.No Violations Noted. Major Areas Inspected:Review of Physical Security Program ML20202J1301998-01-0202 January 1998 Insp Rept 50-440/97-16 on 971004-1201.Violations Noted. Major Areas Inspected:Operations,Maint & Plant Support IR 05000440/19970221997-12-31031 December 1997 Insp Rept 50-440/97-22 on 971015-1201.Violations Noted. Major Areas Inspected:Circumstances That Led to Inadvertent Loss of Reactor Pressure Vessel Water Inventory That Occured on 971011 IR 05000440/19970151997-12-21021 December 1997 Insp Rept 50-440/97-15 on 970922-1023.No Violations Noted. Major Areas Inspected:Isi Efforts & Installation Activities of Suppression Pool Suction Strainer Mod IR 05000440/19970091997-11-26026 November 1997 Insp Rept 50-440/97-09 on 970624-0808.Violations Noted. Major Areas Inspected:Operations,Maintenance & Surveillance, Engineering & Plant Support IR 05000440/19970121997-11-26026 November 1997 Insp Rept 50-440/97-12 on 970809-1004.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19970191997-11-25025 November 1997 Insp Rept 50-440/97-19 on 971027-31.No Violations Noted. Major Areas Inspected:Radiological Controls,Radwaste Controls,Radiation Worker Practices & High Radiation Area Controls IR 05000440/19970071997-10-24024 October 1997 Insp Rept 50-440/97-07 on 970503-0623.Violations Noted. Major Areas Inspected:Operations,Maintenance,Surveillance, Engineering & Plant Support IR 05000440/19970141997-10-17017 October 1997 Insp Rept 50-440/97-14 on 970915-19.No Viiolations Noted. Major Areas Inspected:Review of Radiation Protection Program,Including Radiation Protection Planning & Coverage for Sixth Refueling Outage ML20212A3721997-10-16016 October 1997 Predecisional Enforcement Conference Rept on 971007.Areas Discussed:Apparent Violations Identified During Insp & CA Taken or Planned by Licensee.Apparent Violations Involved SE That Failed to Identify Unreviewed Safety Question IR 05000440/19970131997-09-29029 September 1997 Insp Rept 50-440/97-13 on 970826-28.No Violations Noted. Major Areas Inspected:Followup to Maintenance Rule Baseline Insp ML20198L5241997-09-23023 September 1997 Insp Rept 50-440/97-08 on 970721-0827.Violations Noted. Major Areas Inspected:Unresolved Items & Insp follow-up Items Identified by Design Insp Conducted from 970127-0327 IR 05000440/19970101997-08-29029 August 1997 Insp Rept 50-440/97-10 on 970728-0801.Violations Noted. Major Areas Inspected:Review of Solid Radioactive Waste Processing & Shipping Program.Additionally,Radiation Protection Planning for Upcoming Refueling Outage Reviewed IR 05000440/19970111997-08-26026 August 1997 Insp Rept 50-440/97-11 on 970728-31.No Violations Noted. Major Areas Inspected:Licensee Fire Protection Program IR 05000440/19960161997-08-0404 August 1997 Predecisional Enforcement Conference Rept on 970418.Areas Discussed:Violations Noted in Insp Repts 50-440/96-16, 50-440/96-17 & 50-440/96-18 & Corrective Actions IR 05000440/19970041997-06-16016 June 1997 Insp Rept 50-440/97-04 on 970322-0502.No Violations Noted. Major Areas Inspected:Operation,Maint & Surveillance, Engineering & Plant Support ML20140F8371997-06-10010 June 1997 Insp Rept 50-440/97-201 on 970217-0327.Issues Identified Which Challenged Capability of Sys to Perform Complete Scope DBA Mitigation Actions.Major Areas Inspected:Hpcs & Eec Sys IR 05000440/19972011997-06-10010 June 1997 Insp Rept 50-440/97-201 on 970217-0327.Issues Identified Which Challenged Capability of Sys to Perform Complete Scope DBA Mitigation Actions.Major Areas Inspected:Hpcs & Eec Sys 1999-09-09 Category:UTILITY MONTHYEARIR 05000440/19900121990-11-13013 November 1990
[Table view]Insp Rept 50-440/90-12 on 900917-21 & 1001-05.Violations Noted.Major Areas Inspected:Maint,Engineering,Support of Maint & Related Mgt Activities IR 05000440/19900191990-10-12012 October 1990 Insp Rept 50-440/90-19 on 900905-21.No Violations Noted. Major Areas Inspected:Changes in Organization,Outage Planning & Preparation,Internal Exposure Assessment & Zn-65 Contribution to Shutdown Dose Rate IR 05000440/19900131990-08-21021 August 1990 Insp Rept 50-440/90-13 on 900625-0802.Violation Noted.Major Areas Inspected:Completed & in-progress Design Changes, Including Licensee Program for Controlling Temporary Mods IR 05000440/19900161990-08-0808 August 1990 Insp Rept 50-440/90-16 on 900709-13.No Violations Noted. Major Areas Inspected:Operational Radiation Protection & Radwaste Programs Including,Audits & Appraisals,Changes in Organization & Outage Planning & Preparation IR 05000440/19900171990-08-0101 August 1990 Insp Rept 50-440/90-17 on 900709-13 & 25.No Violations Noted.Major Areas Inspected:Confirmatory Measurements & Radiological Environ Monitoring Programs Including,Audits & Appraisals,Changes in Organization & Equipment IR 05000440/19900041990-07-20020 July 1990 Insp Rept 50-440/90-04 on 900305-08,0416-19,0620-22 & 0702. No Violations Noted.Major Areas Inspected:Licensee Actions Re off-gas Sys Operation IR 05000440/19900111990-07-18018 July 1990 Partially Withheld Security Insp Rept 50-440/90-11 on 900611-19 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Physical Barriers,Protected Areas,Vital Areas, Compensatory Measures,Assessment Aids & Access Control IR 05000441/19900011990-07-17017 July 1990 Insp Rept 50-441/90-01 on 900625-28.No Violations Noted. Major Areas Inspected:Preservation Activities Affecting Structures,Components & Matl During Extended Const Delay IR 05000440/19900081990-06-29029 June 1990 Safety Insp Rept 50-440/90-08 on 900416-0611.Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Items,Independent Safety Engineering Group,Info Notice,Ler & SER Followups & Monthly Surveillance Observation IR 05000440/19890251989-09-27027 September 1989 Insp Rept 50-440/89-25 on 890829-0901.No Violations, Deficiencies or Deviations Noted.Major Areas Inspected: Annual Emergency Preparedness Exercise Involving Observation by NRC of Key Functions & Locations During Exercise IR 05000440/19890211989-09-13013 September 1989 Safety Insp Rept 50-440/89-21 on 890731-0911.No Violations Noted.Major Areas Inspected:Startup Testing Activities Subsequent to Initial Refuel Outage,Including Core Performance & Reactor Engineering IR 05000440/19890241989-09-0707 September 1989 Partially Withheld Insp Rept 50-440/89-24 on 890821-24.No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits,Protected & Vital Area Physical Barriers & Detection & Assessment Aids ML20247G9341989-09-0707 September 1989 Insp Rept 50-440/89-22 on 890807-23.Violations Noted.Major Areas Inspected:Licensee Response to Diagnostic Evaluation Team Rept of Facility,Dtd May 1989 IR 05000440/19890171989-08-18018 August 1989 Safety Insp Rept 50-440/89-17 on 890606-0811.Violations Noted.Major Areas Inspected:Allegation Followup, Operational Safety Verification,Surveillance & Maint Observation & Onsite Followup of Events IR 05000440/19890141989-07-0505 July 1989 Safety Insp Rept 50-440/89-14 on 890425-27 & 0620.No Violations or Deviations Noted.Weakness Noted Re Licensee Review of Contractor Engineering Efforts.Major Areas Inspected:Loose Drywell Head Bolting Event IR 05000440/19890201989-06-26026 June 1989 Enforcement Conference Rept 50-440/89-20 on 890607.Major Areas Discussed:Possible Potential for Overexposure,Apparent Violations Associated W/Matter & Licensee Perspective & Corrective Actions IR 05000440/19890071989-06-21021 June 1989 Insp Rept 50-440/89-07 on 890309-0605.Violations Noted.Major Areas Inspected:Licensee Action on Previous Insp Items, Refueling Activities,Operational Safety Verification,Maint Observation,Allegation Followup & Onsite Followup of Events IR 05000440/19890151989-06-16016 June 1989 Insp Rept 50-440/89-15 on 890515-0608.No Violations Noted. Major Areas Inspected:Refueling Activities During First Refuel Outage at Plant ML20244C2351989-06-0505 June 1989 Insp Rept 50-440/89-16 on 890502-0602.Violations Noted Re Inadequate Surveys & Failure to Use Dosimetry in High Radiation Area.Major Areas Inspected:Allegations of Possible Overexposure.Overexposure Probably Did Not Occur IR 05000440/19890131989-05-17017 May 1989 Partially Withheld Physical Security Insp Rept 50-440/89-13 on 890424-28 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Audits, Protected & Vital Area Physical Barriers & Aids IR 05000440/19890101989-05-16016 May 1989 Safety Insp Rept 50-440/89-10 on 890314-0510.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp Activities,Including Review of Programs & Procedures & Observation of Work Activities IR 05000440/19890191989-05-16016 May 1989 Insp Repts 50-440/89-19 & 50-441/89-01 on 890425-28.No Violations or Deviations Noted.Major Areas Inspected: Equipment,Structure & Matl Preservation Activities During Extended Const Delay & Heat Damaged Cables IR 05000440/19890181989-05-16016 May 1989 Enforcement Conferenence Rept 50-440/89-18 on 890511.Major Areas Discussed:Violations of 10CFR50,App B,Criterion Xvi Re Inadequate Licensee Corrective Action to Correct & Prevent Recurrence of Previously Identified Deficiencies IR 05000440/19890111989-05-0505 May 1989 Safety Insp Rept 50-440/89-11 on 890320-0419.Deviation Noted.Major Areas Inspected:Environ Qualification of Electrical Equipment Per 10CFR50.49,weep Holes in Terminal Boxes,Asco MSIV Solenoids & Reg Guide 1.97 Commitments IR 05000440/19890081989-04-0303 April 1989 Insp Rept 50-440/89-08 on 890306-10.Violations Noted.Major Areas Inspected:Operational Radiation Protection Program During Refueling Outage,Including Organization & Mgt Control & Audits & Appraisals IR 05000440/19890041989-03-20020 March 1989 Insp Rept 50-440/89-04 on 890206-10.No Violations Noted. Major Areas Inspected:Confirmatory Measurements,Including Plant Chemistry Organization,Mgt Controls,Training & Qualifications,Qa,Audits & PASS IR 05000440/19880141988-10-21021 October 1988 Insp Rept 50-440/88-14 on 880829-0923.No Violations Noted. Major Areas Inspected:Operational Radwaste & Transporation Program & Operational Radiation Protection Program IR 05000440/19880131988-09-26026 September 1988 Insp Rept 50-440/88-13 on 880830-0901 & 0913-15.No Violations Noted.Major Areas Inspected:Licensee Action on Previously Identified Insp Findings & Licensee Compliance W/ 10CFR50.62 ATWS Rule IR 05000440/19880121988-09-14014 September 1988 Insp Rept 50-440/88-12 on 880701-0823.Violations Noted.Major Areas Inspected:Nrc bulletins,10CFR21 Repts,Nrc Generic Ltrs,Operational Safety,Nonroutine Events,Lers,Esf Sys Walkdown & Physical Security IR 05000440/19880111988-07-0505 July 1988 Insp Rept 50-440/88-11 on 880613-17.No Violations Noted. Major Areas Inspected:Info Notices IR 05000440/19880061988-06-22022 June 1988 Insp Repts 50-440/88-06 & 50-441/88-03 on 880502-05.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Response Facility Appraisal & Reviews of Radioactive Release Assessment & Meteorological Info IR 05000440/19880101988-06-22022 June 1988 Insp Repts 50-440/88-10 & 50-441/88-05 on 880523-0610.No Violations Noted.Major Areas Inspected:Licensee Implementation of Generic Ltr 83-28 in Areas of Equipment Classification,Vendor Interface & post-maint Testing IR 05000440/19882001988-06-0606 June 1988 Insp Rept 50-440/88-200 on 880314-25.No Violations Noted. Major Areas Inspected:Control Room Operations & Activities That Interfaced W/Operations & Supported Safe Operation of Plant IR 05000440/19880041988-05-27027 May 1988 Insp Rept 50-440/88-04 on 880223-0419.Violations Noted.Major Areas Inspected:Previous Insp Items,Operational Safety, Nonroutine Events,Maint,Surveillance,Esfs,Operational Safety Team Insp Findings & Allegations IR 05000440/19880021988-05-24024 May 1988 Allegation Review Insp Rept 50-440/88-02 on 880323.No Violations Noted.Major Areas Inspected:Review of Allegation Received by Region III of Employee Allegedly in Possession of Illegal Substance.Allegation Not Substantiated IR 05000440/19880081988-05-0606 May 1988 Insp Rept 50-440/88-08 on 880411-15,20,26 & 28.No Violations or Deviations Noted.Major Areas Inspected:Chemistry Program, Including Procedures,Organization & Training,Reactor Sys Water QC Programs & Qa/Qc Program in Lab ML20153G4261988-05-0303 May 1988 Insp Rept 50-440/88-05 on 880404-08 & 13.No Violations Noted.Major Areas Inspected:Followup on Security LER, Security & Implementing Procedures,Mgt Effectiveness, Security Organization,Records & Repts & Testing & Maint ML20148M8301988-03-24024 March 1988 Insp Rept 50-440/87-25 on 880111-15,25-29 & 0209.Violations Noted.Major Areas Inspected:Licensee Action Re Allegation & Maint Activities IR 05000440/19880031988-03-0404 March 1988 Insp Rept 50-440/88-03 on 871231-880222.Violations Noted. Major Areas Inspected:Previous Insp Items,Operational Safety,Nonroutine Events,Maint,Surveillance,Ler,Allegations, Physical Security & Radiological Controls IR 05000440/19870271988-02-0909 February 1988 Insp Rept 50-440/87-27 on 871129-1204.No Violations or Deviations Noted.Major Areas Inspected:Msiv Closure Failures of 871129 & Related Activities IR 05000440/19870231988-02-0202 February 1988 Insp Rept 50-440/87-23 on 871020-1230.Violations Noted. Major Areas Inspected:Previous Insp Items,Ie Bulletins, 10CFR21 Repts,Regional Ofc Request,Operational Safety, Nonroutine Events,Lers,Physical Security & Maint IR 05000440/19870241988-01-22022 January 1988 Augmented Insp Rept 50-440/87-24 on 871104-09.No Violations or Deviations Noted.Major Areas inspected:871029 & 1103 MSIV Closure Failures,Including Root Cause Safety Significance & Maint History IR 05000440/19870261987-12-30030 December 1987 Insp Rept 50-440/87-26 on 871207-11.No Violations or Deviations Noted.Major Areas Inspected:Operational Radiation Protection program,98% Power Radiation Measurement & Chemical & Radiochemical Startup Tests IR 05000440/19870221987-12-29029 December 1987 Insp Rept 50-440/87-22 on 871103-1221.Violation Noted.Major Areas Inspected:Adequacy of 10CFR50.59 Safety Evaluations IR 05000440/19870161987-12-0909 December 1987 Insp Rept 50-440/87-16 on 870813-1019.Violation Noted.Major Areas Inspected:Esfs,Operational Safety,Nonroutine Events, Lers,Startup Testing,Nrc Regional Ofc Requests,Surveillance Testing & Maint Activities IR 05000440/19870131987-12-0101 December 1987 Safety Insp Rept 50-440/87-13 on 870713-1110.Deficiencies Noted.Major Areas Inspected:Environ Qualification of Electrical Equipment,Licensee Action on SER Commitments & Compliance w/10CFR50.49 IR 05000440/19870211987-10-21021 October 1987 Insp Repts 50-440/87-21 & 50-441/87-05 on 870928-1002.No Violations,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness Program,Including Action on Previous Open Items,Licensee Audits & Dose Projection IR 05000440/19870191987-10-0707 October 1987 Safety Insp Rept 50-440/87-19 on 870831-0904.Violations & Deviations Noted.Major Areas Inspected:Electrical & Instrumentation Corrective & Preventive Maint Activities, Review & Followup of LERs & Training IR 05000440/19870201987-10-0202 October 1987 Insp Rept 50-440/87-20 on 870914-18.No Violations or Deviations Noted.Major Areas Inspected:Confirmatory Measurements Program Including Sampling & QC of Analytical Measurements IR 05000440/19870151987-09-15015 September 1987 Safety Insp Rept 50-440/87-15 on 870629-0701 & 0824-28. Violation Noted.Major Areas Inspected:Qa Program,Including Audits & Selected Sections of Listed Insp Modules 1990-08-08 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000440/19990131999-09-13013 September 1999
[Table view]Insp Rept 50-440/99-13 on 990712-30.Violations Noted. Major Areas Inspected:Effectiveness of Pnpp Program for Identification,Resolution & Prevention of Technical Issues & Problems That Could Degrade Quality of Plant Operations ML20212A8531999-09-13013 September 1999 Notice of Violation from Insp on 990712-30.Violation Noted: from 980324-990730,TS SR 3.5.1.4 & 3.5.2.5 Failed to Require Each ECCS Pump to Develop Pump Differential Pressure Greater than or Equal to ECCS Total Flow Resistance IR 05000440/19990091999-09-0909 September 1999 Insp Rept 50-440/99-09 on 990709-0825.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20211M6521999-08-31031 August 1999 Revised Page Number 4, P2 Status of EP Facilities,Equipment & Resources IR 05000440/19990121999-08-12012 August 1999 Insp Rept 50-440/99-12 on 990712-16.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program IR 05000440/19990081999-07-22022 July 1999 Insp Rept 50-440/99-08 on 990518-0708.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000440/19990031999-06-10010 June 1999 Insp Rept 50-440/99-03 on 990407-0517.Two Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Aspects of Licensee Operations,Maint,Engineering & Plant Support ML20207B1291999-05-20020 May 1999 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000.Violation Noted:Centerior Energy Corp Through Actions of RPM Discriminated Againt Rps,On 970716,as Result of RPS Engaging in Protected Activities ML20209B8891999-05-17017 May 1999 EN-99-019:on 990520,notice of Proposed Imposition of Civil Penalty in Amount of $110,000 Issued to Licensee.Action Based Upon Severity Level II Violation Involving Radiation Protection Manager Discrimination Against Supervisor IR 05000440/19990071999-05-12012 May 1999 Insp Rept 50-440/99-07 on 990412-16.No Violations Noted. Major Areas Inspected:Rp Performance & Oversight of Refueling Outage Activities ML20206Q2301999-05-10010 May 1999 Notice of Violation from Investigation Completed on 990129. Violation Noted:On 970114,info Required by Commission Regulations Not Maintained Complete & Accurate in All Matl Respects ML20196A3131999-05-10010 May 1999 Notice of Violation from Investigation on 990129.Violation Noted:On 970114,K Wierman Employed as Training Instructor at Plant & Deliberately Submitted Info to Util That Wierman Knew to Be Incomplete or Inaccurate IR 05000440/19990061999-05-0606 May 1999 Insp Rept 50-440/99-06 on 990303-04 & 0412-16.No Violations Noted.Major Areas Inspected:Inservice Insp Efforts & Overlay Repairs of N4C Feedwater Nozzle IR 05000440/19990021999-05-0303 May 1999 Insp Rept 50-440/99-02 on 990225-0406.Non-cited Violations Noted.Major Areas Inspected:Operations,Maintenance, Engineering & Plant Support IR 05000440/19990051999-04-0202 April 1999 Insp Rept 50-440/99-05 on 990301-05.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Npps IR 05000440/19990041999-03-17017 March 1999 Insp Rept 50-440/99-04 on 990222-26.No Violations Noted. Major Areas Inspected:Radiation Protection Program & Radiological Planning for Upcoming Refueling Outage,Which Included Review of Rwps,Alara Reviews & Dose Goals ML20204E7901999-03-17017 March 1999 Insp Rept 50-440/99-01 on 990113-0224.Non-cited Violation Identified.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19980191998-12-23023 December 1998 Insp Rept 50-440/98-19 on 981021-1202.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering ML20210Q9291998-12-10010 December 1998 Investigation Rept 3-1998-007.No Noncompliance Noted.Major Areas Investigated:Alleged Discrimination Against Radiation Protection Supervisor for Testifying as Witness in Dept of Labor Proceedings IR 05000440/19980221998-11-25025 November 1998 Chemistry & RP Insp Rept 50-440/98-22 on 981102-06.No Violations Noted:Major Areas Inspected:Implementation of Chemistry Program,Meteorological Monitoring Program & Control & Monitoring of Personnel Radiation Dose IR 05000440/19980211998-11-18018 November 1998 Insp Rept 50-440/98-21 on 981019-22.No Violations Noted. Major Areas Inspected:Licensed Operator Requalification Program ML20195C7231998-11-10010 November 1998 Notice of Violation from Insp on 980909-1020.Violation Noted:On 980902,inspectors Identified That Fire Watch Did Not Verify That Special Instructions of Burn Permit B98-DG-83,used for Welding Conducted on DG Were Met ML20195C7361998-11-10010 November 1998 Insp Rept 50-440/98-18 on 980909-1020.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980171998-10-0707 October 1998 Insp Rept 50-440/98-17 on 980831-0914.Violations Noted. Major Areas Inspected:Review of Implementation of Solid Radwaste Mgt & Shipping Program.Insp Also Reviewed Conduct of Radiological Environ Monitoring Program ML20154H1681998-10-0707 October 1998 Notice of Violation from Insp on 980831-0914.Violation Noted:As of 980415,licensee Had Not Made Adequate Surveys to Assure Compliance with 10CFR20.2006 IR 05000440/19980161998-09-25025 September 1998 Insp Rept 50-440/98-16 on 980723-0908.No Violations Noted. Major Areas Inspected:Resident Inspectors Evaluation of Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000440/19980151998-09-0808 September 1998 Insp Rept 50-440/98-15 on 980727-31.Violations Noted. Major Areas Inspected:Effectiveness of Selected Elements of Security Program ML20151V3521998-09-0808 September 1998 Notice of Violation from Insp on 980727-31.Violation Noted: on 971219,licensee Conducted Breath Analysis as Part of for Cause Test Based on Odor of Alcohol,However Drug Portion of for Cause Test Not Conducted in Timely Manner IR 05000440/19980131998-08-21021 August 1998 Insp Rept 50-440/98-13 on 980605-0722.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000440/19980141998-08-19019 August 1998 Insp Rept 50-440/98-14 on 980620-24 & 0720-22.No Violations Noted.Major Areas Inspected:Licensee C/A for Issues Identified by NRC Inspections & Licensee Event Repts Submitted to NRC ML20236R8251998-07-16016 July 1998 Insp Rept 50-440/98-11 on 980518-22.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures, Training,Equipment & Supporting Documentation for Maint of medium-voltage & low-voltage Power Circuit Breakers ML20236R8111998-07-16016 July 1998 Notice of Violation from Insp on 980518-22.Violations Noted: as of 980520,as-tested Instantaneous Trip Function of Circuit Breaker EF1B04 Used for Emergency Closed Cooling Pump Motor 1P42C001A,inadequate ML20236N0281998-07-0909 July 1998 Insp Rept 50-440/98-10 on 980421-0604.Violations Noted.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Plant Support ML20236N0231998-07-0909 July 1998 Notice of Violation from Insp on 980421-0604.Violation Noted:Inspectors Identified That on 980504,operations Personnel Failed to Verify 1 Restoration Items Specified in Surveillance Instruction Sys Restoration Checklist ML20236L8941998-07-0808 July 1998 Errata to Notice of Violation from Insp Rept 50-440/97-21 on 971202-980127.Violation Noted:On 980106,combustible Matl W/No Transient Combustible Permit in Fire Area Containing Redundant Trains of safety-related Equipment,Identified ML20249C5641998-06-25025 June 1998 Notice of Violation from Insp on 980601-05.Violation Noted: on 980504-21,an Individual,Conducting Radiologically Restricted Area Entries Under Radiation Work Permits 980003, 980047 & 980051 Did Not Wear Thermoluminescent Dosimeter IR 05000440/19980121998-06-25025 June 1998 Insp Rept 50-440/98-12 on 980601-05.Violations Noted.Major Areas Inspected:Plant Support ML20217M1311998-04-29029 April 1998 Insp Rept 50-440/98-07 on 980223-0305.Violations Noted. Major Areas Inspected:Operations,Engineering & Maintenance ML20217M1141998-04-29029 April 1998 Notice of Violation from Insp on 980223-0305.Violation Noted:On 980227,licensed Operator Incorrectly Removed Red Tag & Installed Fuse for Annulus Exhaust Gas Treatment Sys Instead of Installing Fuse for ESW Ventilation Sys IR 05000440/19980051998-04-27027 April 1998 Insp Rept 50-440/98-05 on 980209-0408.No Violations Noted. Major Areas Inspected:Portions of Licensee Fire Protection Program ML20212H3331998-04-0909 April 1998 EN-97-106A:on 971218,licensee Responded to NOV & Proposed Imposition of Civil Penalty in Amount $100,000.Licensee Denied Violation Re 10CFR50.59 & Requested Remission.Request Denied & Order Imposing Civil Monetary Penalty Issued IR 05000440/19980011998-04-0707 April 1998 SALP 15 Rept 50-440/98-01 for Plant Covering Period from 960915-980228 IR 05000440/19980061998-04-0101 April 1998 Insp Rept 50-440/98-06 on 980128-0310.Violations Noted.Major Areas Inspected:Licensee Operations,Maint & Engineering IR 05000440/19980031998-03-26026 March 1998 Insp Rept 50-440/98-03 on 980223-27.No Violations Noted. Major Areas Inspected:Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000440/19980021998-03-12012 March 1998 Insp Rept 50-440/98-02 on 980112-16 & 26-30.No Violations Noted.Major Areas Inspected:Operations,Engineering & Review of Effectiveness of CA Program ML20203D8211998-02-20020 February 1998 Notice of Violation from Insp on 971202-980127.Violation Noted:On 971208,an Inspector Observed Fire Door Between Div 2 & 3 Emergency Diesel Generator Rooms Stuck in Fully Open Position ML20203D8241998-02-20020 February 1998 Insp Rept 50-440/97-21 on 971202-980127.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support PNO-III-98-009, on 980123,licensee Declared Unusual Event Under Emergency Plan Because of Spill of Up to 275 Gallons of Refrigerant Called Trichlorethylene.No Plant Personnel Were in Bldg at Time of Spill1998-01-23023 January 1998 PNO-III-98-009:on 980123,licensee Declared Unusual Event Under Emergency Plan Because of Spill of Up to 275 Gallons of Refrigerant Called Trichlorethylene.No Plant Personnel Were in Bldg at Time of Spill IR 05000440/19970171998-01-21021 January 1998 Insp Rept 50-440/97-17 on 971103-07 & 971215-18.No Violations Noted.Major Areas Inspected:Ep Program IR 05000440/19980041998-01-16016 January 1998 Insp Rept 50-440/98-04 on 980105-09.No Violations Noted. Major Areas Inspected:Radiolological,Environ & Chemistry Sections Programs 1999-09-09 |
Inspection Report - Perry - 1982004 | |
---|---|
Assessments |
Text
.
.
U.S. NUCLEAR REGULATORY COMMISSION
REGION III
Reports No. 50-440/82-04(DPRP); 50-441/82-04(DPRP)
Docket Nos.. 50-440; 50-441 Licenses No. CPPR-148; CPPR-149 Licensee: Cleveland Electric Illuminating Company P.O. Box 5000 Cleveland, OH 44101 Facility Name: Perry Nuclear Power Plant, Units 1 and 2 Inspection At: Perry Site, Perry, OH Inspection Conducted: March 1 through April 30, 1982 s
Inspector: .Gildnek f/8I/f2 Approved By: J b
fhonklin, Chief f/8f/g2,
' '
eactor Projects Section 2A Inspection Summary Irspection on March 1 through April 30, 1982 (Reports No. 50-440/82-04(DPRP);
50-441/82-04(DPRP@)
Areas Inspected: Routine inspection by the Resident Inspector of safety related construction activities including plant tours; observation of con-cete placements; observation of assembly of an emergency diesel generator; witnessing tests for proposed correction of biological shield wall voiding; inspection of corrective actions taken by a contractor QA department re-sulting from internal audit; and participation in SALP meeting with License This inspection involved a total'of 135 inspector-hours onsite by one NRC inspector including 18 inspector-hours onsite during off-shift Results: No items of noncompliance or deviations were identified.
I l
l I
l l
l
!
!
B206170095 820601 gDRADOCK 05000440 PDR
.
. -
DETAILS 1. Persons Contacted- Licensee Personnel D. R. Davidson, Systems Engineering.and Construction Vice President
- M. R. Edelman, Nuclear Engineering Department Manager R. L. Farrell, Nuclear Quality Assurance Manager J. J. Waldron, Perry Plant Department Manager J. A. Kline, Construction General Supervising Engineer E. Riley, Construction Quality General Supervising Engineer G. R. Leidich, CQS QE Supervisor Kaiser Engineering, Inc. (KEI)
M. R. Kritzer, Lead Civil Quality Engineer Contractor Personnel T. J. Woodman, Project Manager (L. K. Comstock)
P. R. Merlin, QA/QC Manager (L. K. Comstock)
T. Hesmond, QA/QC Manager (National Engineering)
The inspector also contacted and interviewed other licensee and contractor personnel during this inspection perio * Denotes those attending one or more of the exit meeting . Licensee Action on Previous Inspection Findings (Closed) Unresolved Item (440/82-05-01; 441/82-05-01): Fire sup-pression system in certain safety related areas not in compliance with State Code. Gilbert fire suppression engineers have met with the local fire inspector and are making required system modifications to comply with State Codes for those structures clearly under the jurisdiction of the 1979 Revision to the Ohio Basic Building Cod These system modifications will be complete prior to occupancy of the areas. These system modifications do not degrade compliance with 10 CFR 50. Appendix R design requirements for the Fire Suppression Syste . Licensee Action on Other Items ,
(0 pen) 10 CFR 50.55(e) Reports; Subjects: " Incomplete Fill Detected in Reactor Building #2 Bioshield Wall" and " Biological Shield Walls Heavy Density Concrete, Units 1 and 2". The Resident Inspector wit-nessed placement testing material being evaluated for repair of referenced deficiencies in the heavy density concrete of the bioshield walls of Units 1 and 2. The material, Master Builder's LL-927 High
.
.
Density Grout, was placed in a mockup of the bioshield wall to check for workability into blind voids without subsequent revoiding. Test blocks were made with different durations of vibrating to check for grout separation. Test cores were obtained from various place-monts and checked for density. The lowest obtained density from the
, upper portion of the longest vibrated test placement was in excess of the required density by fifteen (15) percent. The proposed material appears acceptable, however, the 10 CFR 50.55(e) report remains open pending actual bioshield repair and actual placement sample test ]
4. Plant Tours During normal working hours and during off-shifts, the inspector made several walkdowns of the plant to observe general housekeeping and work progres No items of noncompliance or deviations were identifie . Observation of Containment Concrete Placements The inspector observed two placements of part of the upper refueling pools in Reactor Building Number 2 by National Engineering and Con-tracting Company, including placement RB2-WO3-689 on 3/12/82 and placement RB2-WO8-689 on 4/16/82. The inspector verified that the required pre placement inspections were made and documented. The inspector observed inprocess inspection made by the contractor and project CQS inspectors observed concrete sampling, and reviewed test results for interim cure strengt !
No items of noncompliance or deviations were identified.
l 6. Observation of Final Assembly of Diesel Generator The inspector observed the assembly of a Unit 2 Emergency Diesel
- Generator. The assembly was cone by L. K. Comstock using procedure 4.3.28, " Installation of the Rotor and Stator for Emergency Generators".
'
. The installation was being monitored by a General Electric Company technical representativ Installation problems, caused by congestion in the assembly area, required changes in the approved installation procedure. The written changes were field approved by those personnel who approved the original procedure, and by the GE technical repre-
, sentative prior to implementation. All of the field generated pro-cedural changes were incorporated into a subsequent revision to the i procedure for use in assembly of the Unit 1 Emergency Diesel Generator.
,
No items of noncompliance or deviations were identified.
i 7. Review of Contractor Corrective Actions
. The inspector reviewed changes in the QA program of L. K. Comstock i
resulting from a recent internal audit performed by a Comstock i
!
l
!
!
'
- . ~ _ _ - _ _ , _ . - _ . . _ _ . _ . - - . _ - - __ _ - _ . _ . _ .
. . . _ _ _ - _ _ _ _ _ .
'
1 e
! .
Corporate QA team. The changes center around better documentation control by limiting access to documentation flies, a check list of-required documents for each. equipment file, as review of documentation for completeness and accuracy before filing, and procedures which.
.
more clearly define documentation. requirement No items of noncompliance or deviations were identifie ,
8. SALP Meeting with Licensee Management The inspector and NRC Region III management met with Cleveland Electric Illuminating Perry Project Management on April 2, 1982,
- to present and discuss the results of the SALP II evaluation of I the Perry facility. Details of that evaluation are contained in a separate repor . Exit Meeting i The resident Inspector met with the licensee representatives denoted in Paragraph 1 on March 19 and April 30, 1982, to discuss the scope and results of the inspection.