ML20052B641

From kanterella
Jump to navigation Jump to search
Effects of Vessel Head Voiding During Transients & Accidents in C-E Nsss.Prepared for C-E Owners Group
ML20052B641
Person / Time
Site: San Onofre  
Issue date: 03/31/1982
From:
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
To:
Shared Package
ML13323A274 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.K.2.17, TASK-TM NUDOCS 8205030402
Download: ML20052B641 (78)


Text

CEN - 199 EFFECTS OF VESSEL HEAD VOIDING DURING TRANSIENTS AND ACCIDENTS IN C-E NSSS's Prepared for the C-E OWNERS GROUP MARCH,1982 SkS T MS COMBUSTION ENGINEERING. INC.

820503DNoa

LEGAL NOTICE THIS REPORT WAS PREPARED AS AN ACCOUNT OF WORK SPONSORED BY COMBUSTION ENGINEERING, INC. NEITHER COMBUSTION ENGINEERING NOR ANY PERSON ACTING ON ITS BEHALF:

A.

MAKES ANY WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, WITH RESPECT TO THE ACCURACY, COMPLETEN$SS, OR USEFULNESS OF THE INFORMATION CONTAINED IN THIS REPORT, OR THAT THE USE OF ANY INFORMATION, APPARATUS, METHOD, OR PROCESS DISCLOSED IN THIS REPORT MAY NOT INFRINGE PRIVATELY OWNED RIGHTS: OR B.

ASSUMES ANY LIABILITIES WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FrdM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THIS REPORT.

(

5 e

p m

_~

ABSTRACT I

This report has been prepared in response to Item II.K.2.17 of NUREG-0737, potential for voiding in the reactor coolant system during transients.

Three types of plant transients which have the potential to cause voiding in the reactor vessel upper head region are addressed. These transients are normal operational transients, natural circulation cooldown transients, and the t

depressurization and overcooling transients addressed in Chapter 15 of the

(

plant Safety Analysis Report. The evaluation concludes that any potential void formation during these transients is not great enough to impair reactor coolant I

circulation or core coolability.

l 9

L i

.i i

e 4

1 9

t P

f T

Y b

I I

{

i TABLE of CONTENTS Section Title Page t

i

1.0 INTRODUCTION

l -l l

1.1 Purpose 1-1 I

1.2 Scope 1 -1

1.3 Background

1-2 1.4 RCS Voiding 1-2 i

1.5 Operator's Role in RCS Voiding 1-3 1.6 Format of Report 1-3 l

1.7 Results of Evaluation l-4 1

2.0 TRANSIENTS 2-1 2.1 General 2-1 2.2 Normal Operational Transients 2-2 f

I 2.3 Natural Circulation Cooldowns 2-4 l-2.4 SAR Chapter 15 Transients 2-7 2.5 Related Issues 2-13 I

3.0 SIMULATION CAPABILITIES 3-1 3.1 LTC 3-1 3.2 CESEC 3-1 4

1 e

P 4,

4.0

SUMMARY

4-1 i

5.0 REFERENCES

5-1 l

1 11

LIST OF APPENDICES Appendfx Title Page A

Typical C-E Emergency Procedure A-1 Guidelines Related to RCS Voiding b

G e

fii

~

LIST OF TABLES Table Title Page 2-1 Typical Parameters for Plant Classes 2-16 2-2 Asymptotic Fluid Temperature 2-17 Difference (AT) Between the Reactor Vessel Upper Head and Upper Plenum Regions 2-3 Temperature Difference Which Will 2-18 Cause Stagnation in Isolated Steam Generator for an Asymmetric Cooldown 2-4 Integrated Primary to Secondary 2-19 Leakage and MSSVs Releases 6

iv

LIST OF FIGURES i

Figure Title Page 2-1 Inadvertent Opening of an Atmospheric 2-20 Dump Valve with Loss of Offsite Power Reactor Vessel Liquid Volume vs Time 2-2 Steam Line Break with Loss of Offsite Power 2-21 Operating Plants Reactor Vessel Liquid Volume vs Time 2-3 Steam Line Break with Loss of Offsite Power 2-22 Operating Plants l'

RLS Pressure vs Time 2-4 Steam Line Break with Loss of Offsite Power 2-23 Operating Plants Safety Injection Flow vs Time 2-5 Steam Line Break with Loss of Offsite Power 2-24 Operating Plants Core Power vs Time 2-6 Steam Line Break with Loss of Offsite Power 2-25 3410 Mwt Plants l

Reactor Vessel Liquid Volume vs Time 2-7 Steam Line Break with Loss of Offsite Power 2-26 i

3410 Mwt Plants RCS Pressure vs Time 1

2-8 Steam Line Break with Loss of Offsite Power 2-27 3410 Mwt Plants Safety Injection Flow vs Time v

5 LIST OF FIGURES (continued)

Figure Title Page 2-9 Ste3m Line Break with Loss of Offsite Power 2-28 3410 Mwt Plants Core Power vs Time 2-10 Steam Line Break with Loss of Offsite Power 2-29 3800 Mwt Plants Reactor Vessel Liquid Volume vs Time l

2-11 Steam Line Break with Loss of Offsite Power 2-30 3800 Mwt Plants RCS Pressure vs Time 2-12 Steam Line Break with Loss of Offsite Power 2-31 3800 Mwt Plants l

Safety Injection Flow vs Time 2-13 Steam Line Break with Loss of Offsite Power 2-32 l

3800 Mwt Plants 1

Core Power vs Time 2-14 Steam Line Break with Loss of Offsite Power 2-33 3800 Mwt Plants (Mixing Effect)

RCS Pressure vs Time 2-15 Steam Line Break with Loss of Offsite Power 2-34 3800 Mwt Plants (Mixing Effect)

Safety Injection Flow vs Time 2-16 Steam Line Break with Loss of Offsite Power 2-35 3800 Mwt Plants (Mixing Effect)

Core Power vs Time vi

LIST OF FIGURES (continued)

Figure Title Page 2-17 Steam Generator Tube Rupture with 2-36 Loss of Offsite Power Operating Plants Reactor Vessel Liquid Volume vs Time 2-18 Steam Generator Tube Rupture with 2-37 i

I Loss of Offsite Power Operating Plants RCS Pressure vs Time i

2-19 Steam Generator Tube Rupture with 2-38 Loss of Offsite Power Operating Plants Safety injection Flow vs Time 2-20 Steam Generator Tube Rupture with 2-39 Loss of Offsite Power i

3410 Mwt Plants 4

Reactor Vessel Liquid Volume vs Time 2-21 Steam Generator Tube Rupture with 2-40 Loss of Offsite Power 3410 Mwt Plants RCS Pressure vs Time 2-22 Steam Generator Tube Rupture with 2-41 Loss of Offsite Power 3410 Mwt Plants Safety Injection Flow vs Time vii w

LIST OF FIGURES

/

(continued)

Figure Title Page 2-23 Steam Generator Tube Rupture with 2-42 Loss of Offsite Power 3800 Mwt Plants Reactor Vessel Liquid Volume vs Time 2-24 Steam Generator Tube Rupture with 2-43 Loss of Offsite Power 3800 Mwt Plants RCS Pressure vs Time 2-25 Steam Generator Tube Rupture with 2-44 Loss of Offsite Power 3800 Mwt Plants Safety Injection Flow vs Time 2-26 Steam Line Break with Loss of Offsite Power 2-45 Operating Plants Reactor Vessel Liquid Volume vs Time 2-27 Steam Line Break with Loss of Offsite Power 2-46 Operating Plants RCS Pressure vs Time t 28 Steam Line Break with Loss of Offsite Power 2-47 3800 Mwt Class of Plants Reactor Vessel Liquid Volume vs Time 2-29 Steam Line Break with Loss of Offsite Power 2-48 3800 Mwt Plants

. RCS Pressure vs Time viii

I i

i i

c LIST OF FIGURES l

f (continued) i

?

i Figure Title Page

[

I i

i 1

2-30 Steam Line Break with Loss of Offsite Power 2-49 t

I t

3800 Nt Plants Safety Injection Flow vs Time i

3-1A LTC Model 3-4 1

3-1R LTC Volume Description 3-5 j

,t 3-2A CESEC Nodal Scheme 3-6 3-28 Physical Description of Nodes 3-7 9

J r

i 4

e r

.e e

I e

?

I

?

IX t

e n.

?

2

1.0 INTRODUCTION

1.1 Purpose This report provides the results of an evaluation on the potential for voiding in the reactor coolant system (RCS) during transients as required by NUREG-0737. Item II.K.2.17 (Reference 1). More specifically the report addresses the following concerns:

1.

Situations which will cause voiding, 2.

Effects of void formation on system response, 3.

Feasibility of preventing voids from forming, and 4.

Adequacy of operator guidance for mitigating the consequences of voids or dealing with void formation.

The assessment of void formation on system response for nuclear steam supply systems (NSSSs) designed by C-E shows that any potential void formation during 1

the transients addressed in this report is not great enough to impair reactor coolant circulation or core coolability. The voids calculated to occur in the reactor vessel upper head region during these transients were not predicted to expand beyond the top elevation of the hot legs. This is consistent with test data gathered at the LOFT facility, under more extreme conditions, which demonstrates that natural circulation flow is not significantly affected even when there are small (less than 15% void fraction) amounts of voids in the hot leg.

1.2 Scope 9

Three types of plaM 'cansients which have the potential to cause voiding in the reactor vessel g,,er head region are 1) normal operational transients (such as plant trips, load changes, cooldown with the reactor coolant pumps (RCPs) running), 2) natural circulation cooldown transients, and 3) the i

depressurization and overcooling transients addressed in Chapter 15 of the plant Safety Analysis Report (SAR). These three types of plant transients are addressed in this report.

The report additionally addresses the following three issues in providing for the assessment of void formation on system response for NSSSs designed by C-E.

1-1

These are 1) the effect of void formation in the reactor vessel upper head l

region on Emergency Core Cooling System (ECCS) performahce, 2) the consequences of non-uniforn void mixing in the reactor vessel upper head region on system response, and 3) the effects of hot spots on system response.

The C-E plants addressed in this report are those listed in Table 2-1.

These include Ft. Calhoun, Maine Yankee, Palisades, Calver Cliffs Units 1 and 2, Millstone Unit 2, St. Lucie Units 1 and 2, Arkansas Nuclear One Unit 2, San l

Onofre Units 2 and 3, Waterford Unit 3, Palo Verde Units 1, 2, and 3, Yellow Creek Units 1 and 2, and WNP Units 3 and 5.

f

1.3 Background

The NRC request to address the RCS voiding concern was originally sent to Babcock and Wilcox (B&W) licensees only. The letter sent by R. W. Reid of the NRC (Reference 3) cited as a general safety concern the coarse representation of analysis models for simulating the reactor vessel upper head region transient response and, therefore, their inability for predicting the effects j

of voids properly.

Item II.K.2.17 of NUREG-0737 made the above request generic

[

to all PWR operating reactors and applicants.

l l

1.4 RCS Voiding l

I RCS voiding is a phenomenon dependent on the temperature and pressure of the coolant and the amount of coolant inventory in the system. When the system l

pressure is rapidly reduced as in a depressurization and cooldown event, RCS j

regions where the flow is small or negligible can become hot spots that reach saturation.

This is because the fluid in those regions may thermally lag the rest of the RCS during the depressurization.

The most likely region in the RCS to become saturated is the reactor vessel I

upper head region. Only a small fraction of the total core / upper plenum flow i

goes through this region when the reactor coolant pumps are running. The j

region becomes relatively stagnant when the pumps are shut off. Once the RCS j-pressure reaches the saturation temperature of the reactor vessel upper head region during a depressurization, voids are likely to form due to flashing of i

the hot fluid.

Additionally, the effect of the heat transfer from the reactor f

vessel walls and internals enhances the void formation in the upper head region 1-2

i through boilof f.

However, voids in the upper head region, although not desirable, are not an operational concern. The pressurizer normally operates with a void, that is, a steam space. Additionally, the ability of an operator to cope with such a situation was demonstrated during the natural circulation cooldown event at St. Lucie Unit 1 (Reference 6).

Voids may also be formed in an isolated steam generator loop during a cooldown, if the flow in that loop is stagnant and the RCS is depressurized below the isolated steam generator saturation temperature / pressure. However, by conducting non-symmetric cooldowns in a controlled manner, voiding under this circumstance can be prevented.

1.5 Operator's Role in RCS Voiding The operator's role during RCS voiding situations is to mitigate the consequences of voids while maintaining the critical safety functions (Reference 7). The safety functions being the success paths the operator has to ensure core reactivity control and heat removal and primary system inventory control, pressure control, and heat removal.

The C-E emergency procedure guidelines documented in CEN-152 (Reference 2) provide technical input for utilities owning C-E NSSSs to develop detailed emergency procedures. The C-E guidelines adequately address the steps that the operator can take to prevent voids and mitigate or deal with voids if they do occur. A summary of the C-E emergency procedure guidelines addressing voids is provided in Appendix A.

1.6 Format of Report Section 2.1 provides the preface for Section 2.0: Transients.

Sections 2.2, 2.3, annd 2.4 discuss, respectively, the types of plant transients addressed in

~

the report, namely, the normal operational transients, the natural circulation cooldowns, and the SAR Chapter 15 transients. Section 2.5 addresses related issues such as the consequences of non-uniforre mixing in the reactor vessel upper head region and the effects of hot spo',s on system response. The effects of void formation in the reactor vessel upper head region on ECCS performance is addressed in Section 2.4.

1-3

Section 3.0 provides a synopsis of the analytical capabilities used by C-E in support of the information presented in the report.

Section 3.1 summarizes the capabilities of the LTC code, while Section 3.2 summarizes the capabilities of CESEC.

Section 4.0 provides a summary, in the form of conclusions, of the information presented in Section 2.0.

The references are detailed in Section 5.0.

Appendix A, as previously mentioned in Section 1.5, summarizes the C-E emergency procedure guidelines which address RCS voiding.

1.7 Results of Evaluation The results of the evaluation show that voiding in the reactor vessel upper head region is not expected to occur for normal operational transients. For natural circulation cooldown transients voiding may occur in the reactor vessel upper head region. However, in the event that voids are formed, the operator guidance provi.ded in C-E's emergency procedures guidelines (Reference 2) adequately address how to control and reduce the voids. Stress calculations performed using conservative asssumptions have shown that cooldown of a voided upper head with cooler reactor coolant system water is well within the reactor vessel stress limits. For SAR Chapter 15 transients the impact of voiding will not result in violation of the Nuclear Regulatory Commission (NRC) Standard Review Plan (SRP) requirements for all C-E plants.

Additionally, the report concludes that the consequences of non-uniform mixing in the reactor vessel upper head are of secondary nature when compared to the consequences from not explicitly modelling the reactor vessel upper head region and that hot spots have negligible effects on plant parameters and, more importantly, on transient consequences.

Finally, the report concludes that any potential void formation during the plant transients addressed is not great enough to impair reactor coolant circulation or core coolability.

1-4

2.0 TRANSIENTS 2.1 General Voids in the RCS are formed as a result of not maintaining a subcooled margin in the reactor coolant system. The extent of void formation is mainly affected by the rate of RCS depressurization, the metal structure heat transfer area, the fluid volume in the reactor vessel upper head region, the fraction of vessel flow which passes through the upper head, the cooldown rate of the secondary side, the performance of the ECCS, the ratio of NSSS power level to RCS fluid volume, and the initial steady state fluid conditions.

The RCS region of most concern regarding voiding is the reactor vessel upper head region.

Under normal operating conditions the subcooled margin is maintained via the pressurizer pressure control system using the pressurizer sprays and heaters.

Since this system is designed to accommodate normal operational transients with adequate subcooled margin, voids in the RCS are highly improbable during normal operating conditions.

During a natural circulation cooldown, circulation of fluid through and cooldown of the reactor vessel upper head are reduced. As a consequence the fluid in this region may reach saturation conditions during depressurization resulting in voids in the upper head.

Subcooled margin cannot be maintained during certain design basis events 1

analyzed in the SARs. These SAR events are the depressurization and rapid cooldown transients.

For these events, the pressurizer fluid drains or the system pressure drops to saturation conditions and voids form in the reactor vessel upper head region, where the hottest fluid in the system is located.

The results provided herein are by class of C-E plants. The conclusions apply to all plants considered. Key plant parameters were identified for the C-E plants in order to facilitate categorization of the plants into classes. The C-E plants were categorized under three basic classes:

the operating plants, the 3410 Mwt plants, and the 3800 Mwt plants. The C-E plants and the typical parameters for these plant classes are identified in Table 2-1.

The significance of including the ratio of upper head volume to RCS volume 2-1

is that the larger the upper head volume is, the greater the impact of void formation upon transient RCS pressure.

The safety injection actuation setpoint and the high pressure safety injection pump shutoff head are parameters which significantly affect steam line break events.

The auxiliary feedwater flow and I

capacity of the main steam safety valves are parameters which influence the releases during a steam generator tube rupture event.

The saturation pressure at the hottest temperature of the system provides an indication as to how low the pressure in the RCS system would have to drop before voids would form.

~

2.2 Normal Operational Transients Normal operational transients are defined as those plant events wherein most or all of the RCPs continue running throughout the event.

Examples of normal operational transients are plant trips, load changes, and loss of one RCP.

These transients have been analyzed in CEN-128 (Reference 4). The calculations have shown that the subcooled margin in the RCS loop, which excludes the reactor vessel upper head region, for these events is at least 50 F.

l The reactor vessel upper head region is potentially susceptible to voiding since only a small fraction of the total ccre/ upper plenum flow goes through this region.

Typically, this fraction is about one percent when any of the RCPs are running. This flow is sufficient to completely replace the entire reactor vessel upper head region fluid in about two minutes for the operating plants and the 3410 Mwt plants and in about 5 minutes for the 3800 Mwt plants.

The forcing functions which determine the reactor vessel upper head region fluid temperature during RCP operation are the mass flow rate into it and the corresponding temperature of that fluid. A detailed energy balance considering conduction, radiation, and convection has shown that the region is typically about 1 F cooler than the core exit / upper plenum region temperature under steady state operating conditions. Hence, the subcooled margin in the i

reactor vessel upper head region is essentially equal to that of the RCS hot legs under steady state operation.

i Under transient conditions, with the RCPs running, there will be a time lag between a change in the core exit / upper plenum temperature and the time when the reactor vessel upper head fluid temperature reaches approximately the same temperature. This time lag is approximately proportional to the ratio of the total thermal masses of the region, including the metal contributions, divided 2-2 l

by the net energy flow rate through the region. Numerically, the time lag for l

the operating plants and the 3410 Mwt plants has been calculated to be about 8 L

minutes. For the 3800 Mwt plants, the time lag has been calculated to be about 25 minutes. The time lag and the RCS cooldown rate will then determine the fluid temperature difference between the reactor vessel upper head region and the upper plenum region.

This fluid temperature difference has been calculated for three constant cooldown rates assuming an operator controlled cooldown conducted in such a manner as to maintain a 50 F subcooling in the RCS loop. The asymptotic values reached by the temperature difference for the various cooldown rates are presented in Table 2-2.

The reduction in the reactor vessel upper head region subcooling relative to the RCS loop subcooling is at most 4'F for the operating plants and the 3410 Mwt plants. For the 3800 nwt plants this maximum value is 14*F.

Therefore, the reactor vessel upper head region subcooling during cooldowns with RCPs running remains sufficient to preclude any voids from forming in this region even at the maximum controlled cooldown rate allowed by plant Technical Specifications of 100 F/hr.

For a reactor trip from normal operation, a rapid cooldown follows the trip.

The loop cooldown as a result of RCS shrinkage will lower the pressurizer pressure and level. For this case, a conservative estimate of the reactor vessel upper head region minimum subcooling during the cooldown can be made from the initial fluid temperature in the region and the minimum RCS pressure. From the results presented in Reference 4 for one pump loss of forced reactor coolant flow, a ceaservative estimate of the reactor vessel upper head region subcooling was made. The minimum calculated value of about 30*F over the short time interval following a reactor trip when there is no operator action will preclude any voids from forming in this rgion.

The results presented in Reference 4 are typical of the operating plants. However, essentially the same conclusions can be made if similar calculations were to be performed for the 3410 Mwt plants and the 3800 Mwt plants.

In summary, RCS voiding is not expected for C-E plants for normal operational transients. The subcooled margin in the RCS loop expected for these events is typically 50 F or higher; the reactor vessel upper head region subcooling margin can be lower than that for the RCS loop but still high enough to prevent voids from forming.

2-3

2.3 Natural Circulation Cooldowns The preferred mode for performing a plant cooldown is by forced circulation.

However, whenever the RCPs are not available, an alternate method for cooling down the plant is by natural circulation. The cooldown of the plant by natural circulation is possible as a result of temperature gradients in the reactor coolant system. Natural circulation cooldowns as specified by C-E guidelines (Reference 2) require at least 20 F subcooling in the reactor coolant system hot legs. The hot leg temperature must be larger than the cold leg temperature for primary to secondary heat transfer to occur. Therefore, maintaining subcooling with respect to the hot leg temperature will generally suffice to prevent the RCS loops from voiding.

RCS voids may be formed under the following circumstances even though steam generator heat removal is being maintained:

1.

A rapid enough depressurization so that the reactor vessel upper head region reaches saturation.

As previously stated in Section 2.2 this region receives about one percent of the total core / upper plenum flow when the RCPs are running. However, during natural circulation conditions this is not the case.

Instead, the fluid flow into the reactor vessel upper head region is largely due to shrinkage of the fluid in the vessel head caused by conductive cooling heat transfer. As a result, the reactor vessel upper head region fluid is relatively stagnant and will thermally lag the rest of the RCS during a natural circulation cooldown. Failure to account for this lag will result in a steam void being created in the reactor vessel upper head region if the RCS pressure is allowed to drop to the saturation point of the fluid in this region during the cooldown.

C-E's emergency procedure guidelines (Reference 2) recommend a rapid cooldwon within technical specification limits to enhance the conductive cooling capability of the reactor vessel upper head regien (A large temperature difference between the reactor vessel upper head and the RCS fluid will yield a large thermal gradient and a greater heat transfer rate). Additionally, the guidelines recommend that the RCS pressure be maintained as high as possible, within operating restrictions, until the RCS has been cooled down to shutdown cooling initiation temperature and at least 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> has elapsed since the start 2-4

of cooldown. This cooldown strategy will minimize the possibility of voiding in the reactor vessel upper head region.

The time required to cool the reactor vessel upper head region under natural circulation conditions to shutdown cooling entry temperature has been calculated to be about 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> for the operating plants and the 3410 Nt plants and about 55 hours6.365741e-4 days <br />0.0153 hours <br />9.093915e-5 weeks <br />2.09275e-5 months <br /> for the 3800 Nt plants. The larger time requirement of the 3800 Nt plants is due to the larger volume of water in the reactor vessel upper head region (see Table 2-1) and a smaller flow area to fluid volume ratio than for the other plants.

2.

An asymmetric cooldown which results in stagnated flow in one steam generator loop.

An event such as a steam generator tube rupture may require that one steam generator be isolated continuously from the RCS as a heat sink. With one steam generator isolated, the non-isolated unit will carry the total share of the decay heat / sensible heat load.

In order to carry the higher heat load, the non-isolated steam generator has to be at a lower secondary temperature than the isolated one. During normal forced flow conditions in the RCS sufficient reverse heat transfer in the isolated unit occurs to maintain the isolated steam generator at the same relative temperature as the non-isolated RCS loop during a plant cooldown. However, with no RCPs operating, that is, under natural circulation flow, the cooler (non-isolated) steam generator will have larger flows than the hotter (isolated) steam generator. This will result from the secondary temperature difference between the two generators. As the secondary temperature difference between the two generators increases the flow in the isolated generator may eventually stagnate leaving the isolated generator in a hot condition. The temperature difference at which stagnation would occur is a function of the decay heat level and, thus, of the time following the reactor trip. Representative values of the temperature difference which will cause stagnation are provided as a function of time after trip in Table 2-3.

This condition by itself will not necessarily affect core cooling via natural circulation in the non-isolated steam generator and RCS loop. As long as reactivity control, RCS pressure control, RCS inventory control, and RCS heat removal are properly maintained in the non-isolated loop, sufficient natural circulation flow will be maintained through the l

2-5

-z

core and operating loop. However, for a hot isolated steam generator, the temperature in that loop will lag the temperature of the non-isolated loop during the cooldown. This situation could present a problem when trying to depressurize the RCS to initiate shutdown cooling. Depressurization of the RCS below the isolated steam generator's saturation temperature / pressure could then cause voids to form in the isolated RCS loop. This could lead to interruption of the natural circulation cooling established in the non-isolated RCS loop or could cause the isolated steam generator to act like the pressurizer and prevent further depressurization to the shutdown cooling entry pressure. Therefore, asymmetric cooldowns will have to proceed more slowly than symmetric cooldowns in order to cool down the isolated steam generator before shutdown cooling is aligned.

CEN-152 (Reference 2) provides for a preferred method and for an alternate method of cooling an isolated steam generator. The preferred method being to start any RCP, if available, and the alternate method is, if possible, to drain (not completely dry) and refill the isolated steam generator secondary water volume. Control of the cooldown in the isolated loop would then be regulated by the refill rate of the cool feedwater.

Although voiding in the reactor vessel upper head region is possible under the natural circulation cooldown condition discussed above, voids can be prevented by allowing sufficient time for the fluid in the reactor vessel upper head region to cool prior to depressurizing the RCS. For asymmetric cooldowns, voids in the RCS loop can be prevented by a controlled cooldown of the isolated steam generator before shutdown cooling is aligned.

C-E's emergency procedure guidelines adequately address the potential voiding situations by stating that additional time is required to conduct control natural circulation cooldowns.

In addition, the guidelines identify those plant parameters whose changes indicate that a void may exist and provide guidance for eliminating the void.

This guidance consists of a drain and fill procedure to control and reduce the voids. Stress calculations using conservative modeling assumptions have shown that filling the reactor vessel upper head regions with cooler reactor coolant system water is well within the reactor vessel stress limits.

6 2-6

2.4 SAR Chapter 15 Transients SAR Chapter 15 depressurization and overcooling transients which have a potential for causing void formation due to pressurizer drain or depressurization to saturation conditions are increased heat removal by the secondary system events (e.g., steam line break) and the decrease in primary system inventory events (e.g., steam generator tube ruptu;e). Analyses of these transients have been conducted in support of the Waterford Unit 3, St. Lucie Unit 2, and CESSAR-F SARs to evaluate the impact of void formation in the reactor vessel upper head region on system response and in terms of meeting criteria as specified by the SRP guidelines.

The most limiting Chapter 15 accident with respect to void formation for the increase in heat removal events is the steam line break.

For the decrease in inventory events the steam generator tube rupture is limiting. The most limiting anticipated operational occurrence (A00) is the inadvertent opening of an atmospheric dump valve with loss of offsite power (most limiting single failure). Conclusions from these analyses, for which the most severe depressurization is predicted, bound the rest of the SAR Chapter 15 depressurization and overcooling events.

The SAR analyses performed for the above referenced dockets with vessel head voiding indicate that voiding is not extensive enough to uncover the reactor vessel hot legs. Additionally, these analyses conclude that voiding does not result in violation of the SRP requirements for C-E plants.

The main impact of the vessel upper head void is a slower pressure response; since once this relatively stagnant region reaches saturation, it acts like a pressurizer. The slower pressure response can hold up the pressure for steam generator tube rupture and steam line break events. This will increase the primary to secondary leakage during a steam generator tube rupture event and reduce the safety injection flow during a main steam line break event.

However, as discussed below, the impact of these effects do not result in a violation of the criteria specified by the SRP guidelines, even though upper head voiding has an impact upon transient values of plant parameters.

2-7

2.4.1 Increased Heat Removal Events The effect of upper head voiding on the consequences of excess heat removal A00s and accidents (steam line breaks) has been considered for the C-E plants identified in Table 2-1.

The impact of the formation of voids for these events upon the transient values of plant parameters varies from substantial for RCS pressure to negligible for steam generator secondary side pressures.

The impact is qualitatively similar for all C-E plants. Howeve.,

quantitatively the effect of voids is a strong function of the initial energy stored in the reactor vessel upper head region. The larger the upper head volume is, the more the initial stored energy and, consequently, the greater the impact of void formation upon transient RCS pressure.

For overcooling A00s the concern is for potential degradation in fuel performance prior to and during reactor trip (referred to as the pre-trip regime). For steam line breaks there is an additional concern. This is degradation in fuel performance during the post-trip portion of the event when there exists a potential for a return to power condition due to the cooldown.

The issue of pressurized thermal shock, which can be a concern during transients with a severe depressurization and overcooling of the reactor vessel followed by a repressurization, is addressed separately from this report as part of another C-E Owners Group activity.

During the pre-trip portion of the overcooling A00s and steam line breaks no void formation is calculated to occur in the reactor vessel upper head region, since the system remains above saturation. The system becomes saturated af ter the reactor has tripped and the pressure has dropped below the low pressurizer pressure trip setpoint. Therefore, there is no impact from voids on calculated system parameters during the pre-trip regime for overcooling A00s and steam line breaks. As a result there is also no impact upon the fuel performance calculations during this time period.

Void formation can occur in the upper head region for overcooling A00s. This is illustrated in Figure 2-1 for the inadvertent opening of an atmospheric dump valve with loss of offsite power (most limiting single failure) for the 3800 Mwt plants. The effect is less adverse for the other C-E plants. For this event reacter trip occurs at 45 seconds. As seen from the figure, void formation in the reactor vessel upper head region begins at 60 seconds into the 2-8

transient. The void volume increases slowly with the cooldown until reaching its maximum value near the time of steam generator dryout.

Thereafter, the void volume decreases slowly with the RCS pressure increase due to decay heat and the influx of flow from the high pressure safety injection (HPSI) pumps.

The dynamic response of the void volume is dependent on the initial pressurizer level selected. The case shown assumed maximum initial pressurizer level.

This case is compatible with that presented in CESSAR-F.

The impact of void formation in the reactor vessel upper head region upon the post-trip return to power can be very significant for steam line breaks. The amount of boron from the HPSI flow which reaches the core prior to the affected steam generator dryout will impact the negative reactivity available for shutdown and, thus, the potential for a return to power conJition. The HPSI flow is a function of the safety injection actuation signal (SIAS) setpoint and the shutoff head and capacity of the pumps.

Therefore, the higher the saturation pressure and the more energy that is stored in the upper head, the greater the delay in SIAS and the more the flow from the HPSI pumps will be impeded. S;mply stated, as the RCS cools down during a steam line break, the RCS pressure will eventually fall below the saturation pressure of the liquid in the vessel head. The higher this pressure is, the sooner flas,hing takes place in the upper head. Additionally, the higher the stored energy in the liquid and metal of the upper head region is, the more the boiloft. These two effects, will keep the RCS pressure up and, therefore, affect the HPSI flow rate.

The effect of the reactor vessel upper head voiding upon steam line breaks 1

initiated transients is illustrated in Figures 2-2 through 2-13.

Figures 2-2 through 2-5 show calculated results for the operating plants; Figures 2-6 through 2-9 show the results for the 3410 Mwt plants; and Figures 2-10 through 2-13 show the results for the 3800 Mwt plants. The transient presented for each case is a double-ended guillotine break of a main steam line inside containment. The event is initiated from a full power condition with the conservative licensing assumptions of concurrent loss of offsite power, failure of one HPSI pump, and the most reactive CEA stuck in the fully withdrawn position. This information is similar to that presented in the Waterford Unit 3, St. Lucie Unit 2, and CESSAR-F SARs.

2-9

The two sets of curves shown in Figures 2-2, 2-6, and 2-10 represent the following: The solid curves show the transient reactor vessel liquid volume for the case in which the reactor vessel upper head region is explicitly modeled. The dashed curves show the reactor vessel liquid volume for the case for which the fluid volume in the upper head region is assumed to be completely mixed with that of the reactor vessel outlet plenum. Similar comparisons are shown for the RCS pressure (Figures 2-3, 2-7, and 2-11), the safety injection flow (Figures 2-4, 2-8, and 2-12), and the core power (Figures 2-5, 2-9, and 2-13).

Figures 2-2, 2-6, and 2-10 show the reactor vessel liquid volume versus time for the three classes of C-E plants. The dynamic response shown assumes maximum initial pressurizer level to maximize the effect on ECCS performance and, therefore, maximize the post-trip effect on fuel performance.

Calculations performed with a minimum pressurizer level yielded results which quantitatively predict a larger void volume. The larger predicted void volumes are calculated to remain above the top of the hot legs. However, the return to power, which is a key concern for steam line breaks, is more adverse for the cases with the higher initial pressurizer level. These are the cases shown in this document which are consistent with the calculations performed in support of the Waterford Unit 3, St. Lucie Unit 2, and CESSAR-F SARs.

Figures 2-3, 2-7, and 2-11 illustrate the effect of the higher RCS pressure caused by the voids in the upper head and the consequent effect on the safety injection flow (Figures 2-4, 2-8, and 2-12) and core power (Figures 2-5, 2-9, and 2-13). The impact upon safety injection flow for plants with high HPSI shut-off head will be less than that presented in Figures 2-4, 2-8, and 2-12.

Void formation in the upper head will occur for the increase in heat removal events discussed in this section. C-E emergency procedure guidelines (Reference 2) adequately address how to control and reduce the voids as previously mentioned in Section 2.3.

In summary, there is no effect of upper head voiding upon pre-trip consequences for increased heat removal events. Se:ondly, during the post-trip portion of a steam line break transient, upper head voiding may cause a greater potential for return to power. Thirdly, the greater the amount of initial stored energy in the upper head region, the greater the impact upon transient 2-10

results. Lastly, and most importantly, the consequences of steam line breaks as demonstrated in support of the Waterford Unit 3, St. Lucie Unit 2, and CESSAR-F SARs satisfy the SRP acceptance criteria when the reactor vessel upper head region voids effects are conservatively modelled. The licensing calculations presented in the above dockets include the assumption that no mixing occurs between the RCS fluid and the reactor vessel upper head fluid from the time the RCPs are shut off (loss of offsite power is assumed at time 0.0) to the time the RCS fluid begins to re-expand. Once the RCS fluid begins to re-expand, some mixing will take place, as a result of the upper plenum fluid flowing into the upper head. The upper head fluid then starts to cooldown and shrinks. Mixing during the initial portion of the event has a small effect on RCS pressure as seen in Figure 2-14 (one percent of the initial core / upper plenum full power flow was assumed). However, the effect upon the safety injection flow and, consequently, upon the return to power is more significant as shown in Figures 2-15 and 2-16.

2.4.2 Decrease in Primary System Inventory Events The limiting event with respect to void formation in the decrease in primary system inventory event category is the steam generator tube rupture event. The effect of upper head voiding on the consequences of this event has been evaluated for the C-E plants identified in Table 2-1.

The impact is qualitatively similar for all C-E plants. Analyses performed for this event in support of the Waterford Unit 3, St. Lucie Unit 2, and CESSAR-F SARs bound all other events for which void formation is less limiting and/or non-existent in the above event category. This is due to slower cooldown rates and higher minmum RCS pressures for the other events in the category. The major concern for this event is the primary to secondary leakage and, consequently, the seecondary side activity releases.

The loss of primary coolant for a double-ended tube rupture results in a steady decline in RCS pressure. This steady pressure decline continues until the reactor trips (e.g., low pressurizer pressure).

Subsequent to reactor trip the RCS pressure drops very quickly and the pressurizer empties. Voids due to flashing begin to form in the reactor vessel upper head region after the RCS pressure reaches the saturation temperature of the fluid. The RCPs are shutoff subsequent to a SIAS. The thermalhydraulic decoupling of the upper head from 2-11

the rest of the RCS subsequent to the RCPs shutoff and the effect of the metal structure heat transfer from the reactor vessel walls and internals, enhances the void formation in the upper head regions through boiloff.

The analyses presented for the double-ended break of a steam generator tube assume event initiation from a full power condition with the assumptions of loss of offsite power subsequent to generator trip, one percent of the full power core / upper plenum flow into the upper head up to the time that the RCPs are shutoff, RCPs shutoff coincident with loss of offsite power, and the most reactive CEA in its fully withdrawn position.

The effect of the reactor vessel upper head voiding upon the system response is illustrated in Figures 2-17 through 2-25.

Figures 2-17 through 2-19 show the calculated results for the operating plants; Figures 2-20 through 2-22 show the results for the 3410 Mwt plants; and Figures 2-23 through 2-25 show the results for the 3800 Mwt plants.

The solid lines and dashed lines represent, respectively, as for the analyses discussed in Section 2.4.1, the case for which the reactor vessel upper head region is explicitly modelled and the case for which the upper head fluid is mixed completely with that of the reactor vessel outlet plenum. Also, as for the analyses discussed in Section 2.4.1, the maximum allowable pressurizer liquid volume was assumed for these analyses. The radiological consequences of the steam generator tube rupture event are more adverse when maximizing this parameter. However, they still satisfy the SRP guidelines.

Figures 2-17, 2-20, and 2-23 illustrate the reactor vessel upper head response. The amount of voids formed is less limiting than for the analyses shown in Section 2.4.1 and definitely not large enough to expand the steam bubble beyond the top elevation of the hot legs. The duration of the voids will be a function of the rate of RCS cooldown and the safety injection flow rate. The HPSI flow is shown in Figures 2-19, 2-22, and 2-25.

The slower RCS pressure decay for the case for which the upper head is explicitly modelled (see Figures 2-18, 2-22, and 2-24) results in a delayed SIAS and a corresponding delay in the time at which delivery of the HPSI flow begins.

The slower pressure decay for this case is caused by the voids as after the pressurizer empties, the reactor vessel upper head behaves as a pressurizer.

For the 3800 Mwt plants with the upper head not modelled the relatively large amount of HPSI flow (Figure 2-25) results in the crossing of the RCS pressures 2-12

late in the transient as shown in Figure 2-24.

For this plant class the HPSI shutoff head is higher than for the other plant classes which causes this dissimilarity in behavior.

Table 2-4 sumarizes the integrated primary to secondary leakages and the integrated releases through the main steam safety valves (MSSVs) for the three plant classes. When the upper head region is explicitly modelled, the results are more adverse. However, the radiological consequences satisfy the SRP acceptance criteria. The more adverse results are due to the relatively higher RCS pressures and primary to secondary heat transfer for the case the upper head region is explicitly modelled.

In summary, void formation in the upper head will occur for the event presented in this section. C-E emergency procedure guidelines (Reference 2) adequately address how to control and reduce the voids as previously mentioned in Section 2.3.

Secondly, for void formation in the upper head region to occur the pressurizer does not have to drain. Depressurization of the system to saturation conditions is sufficient for voids to be generated (e.g., after a steam line break the rate of depressurization is such that this situation exists). ThirdTy, although natural circulation will not be impeded since the upper head voids do not expand beyond the top of the hot legs, an asymmetric cooldown as discussed in Section 2.3 will exist. Precautions as detailed in that section to prevent voids from forming in the affected steam generator loop need to be considered. Lastly, the consequences of a steam generator tube rupture as demonstrated in the Waterford Unit 3, St. Lucie Unit 2, and CESSAR-F SARs satisfy the SRP acceptance criteria when the reactor vessel upper head region is explicitly modelled.

2.5 Related Issues

~

As discussed previously, the RCS region of most concern regarding voiding is the reactor vessel upper head region. Under natural circulation conditions voids may be formed in this region. For the SAR Chapter 15 transients addressed in Section 2.4 voids will be formed in this region. The SAR transients which maximize the voiding effects are the inadvortent opening of an atmospheric dump valve, the double-ended rupture of a steam line, and the double-ended rupture of a steam generator tube.

2-13

The analyses presented in this report did not consider non-uniform mixing in the reactor vessel upper head region or non-equilibrium effects. The models currently utilized assume homogeneity within the reactor vessel upper head region. However, a hand calculation has been performed for the most limiting SAR Chapter 15 transients, in terms of void formation, in order to provide justification for the methodology that is currently used. For this reason the effect of heterogeneity has been addressed for a steam line break. The model used in the calculations simulates separation of the phases by approximating the response that would occur if the liquid coming into the upper head compressed the vapor present rather than mixed with it.

The calculation assumed that the compression would be isentropic. The reasoning behind this approach is that the incoming liquid in this scenario would compress the vapor in the upper head decreasing its volume and leaving its mass unchanged, that there is no appreciable mixing of the liquid entering,the volume with the vapor space in the volume, and that heat transfer between the two phases and between the metal and vapor is small. As a result for the heterogeneous model assumed, voids would never disappear, but only reduce in volume.

In the homogeneou

,odel voids are predicted to collapse as the enthalpy of the upper head decreases due to the inflow of cooler liquid.

The results of the hand calculations are compared with analyses performed using current models and are shown in Figures 2-26 through 2-30.

The comparisons were only made for the operating plants and the 3800 Mwt plants. The liquid level in the upper head and RCS pressure responses as predicted by the hand calculations are as would be expected if the vapor is compressed rather than mixed with the liquid. No comparison was shown for the HPSI flow for the operating plants, since for the case presented, the calculated RCS pressure remained above their shutoff head.

The hand calculations performed are considered bounding since convective currents within the upper head region are expected to provide some mixing.

Further, heat transfer between the vapor and liquid and between the vapor and metal would slowly cause a reduction in void volume.

In sumary, since the effect of the mixing of the RCS fluid with the upper head fluid occurs after the cooldown phase of the transient (see Figures 2-26 and 2-28), heterogeneity has very little potential impact upon steam line break transient consequences in terms of return-to-power (see Figures 2-5 and 2-14

2-13) for C-E plants. Even for the case for which the RCS pressure (see Figure 2-27) rema, ins above the HPSI shutoff head (operating plants) the potential impact on return-to-power is minimized. The return-to-power is predicted shortly after the maximun upper head void volume (see Figures 2-26 and 2-28) has been calculated and, therefore, prior to the time at which the re-expansion of the RCS fluid can have an effect. The impact of heterogeneity for the steam generator tube rupture in terms of radiological consequences during the time prior to which operator action would be assumed (30 minutes) is also minimal. This results again from the fact that the effect of mixing cf the RCS fluid with the upper head fluid occurs after the cooldown phase of the transient. This is predicted to occur about the time at which operator action i

is assumed.

In general, it can be concluded that heterogeneity is of secondary nature when compared to the effect from not explicitly modelling the upper head region.

l Hot spots effects are expected to be minimal under natural circulation cooldown conditions and SAR Chapter 15 transients.

If any, the effect of hot j

spots in the upper head response would be to start forming voids slightly sooner without changing the total expected amounts of void formed. Under this scenario any hot spots in the upper head would reach saturation temperature sequentially within a short time interval until all of the fluid would be saturated. The impact in RCS pressure response would be negligible. Hot spots in the upper plenum region where voiding may exist are expected to rapidly condense in the subcooled fluid leaving the core / upper plenum region.

In summary, hot spots would have negligible effect on plant parameters and, more importantly, on transient consequences as currently modelled.

1 9

2-15

TABLE 2-1 Typical Parameters for Plant Classes Plant Class l

Item Operating Plants l

3410 Mwt Plants 3800 Mwt Plants; Plants within class Ft. Calhoun, Maine Arkansas Nuclear Palo Verde 1,2,&3, Yankee, Palisades One-2, San Onofre Yellow Creek 1&2, Calvert Cliffs 1 &

283, Waterford 3 WNP 385

' 2, tiillstone 2, St. Lucie 182 NSSS Power Hwt)

<0.24

<0.29 0.28 z

RCS Volume 3

ft 3

RCS Volume (ft )

11,000 12,000 13,400 Upper Head Volume RCS Volume 0.06 0.08 0.14 Safety Injection Actuation Setpoint (psia) 1578 1560 1578 High Pressure Safety Injection Pump Shutoff Head (psia) 1165 1400 1750 Auxiliary Feedwater Flow (% of Initial Flow) 2.2 4.6 5.0 Main Steam Safety Valve Relief Capacity /

Number of Valves Obm/hr/ valve) 868,300 at 785,000 at 1,071,250 at 900 psia /8 1000 psia /10 1345 psia /10 P

at Thot(psia) saturation 1500 1675 1800 2-16

3 F

TABLE 2-2 Asymptotic Fluid Temperature Difference (AT) Between the Reactor Vessel Upper Head and the Upper Plenum Regions AT, F j

RCS Cooldown Rate, Operating and 3800 ht l

OF/hr 3410 Nt Plants Plants

[

I f

^

50 2

7 i

75 3

10 f

1 l

100 4

14 d

4 I

h i

i i

t i

l 4

s I

i 2-17

TABLE 2-3 Temperature Difference Which Will Cause Stagnation in Isolated Steam Generator for an Asymmetric Cooldown*

Time After Trip Temperature Difference Between From Full Power, sec Secondary Sides of Steam Generators, gF 100 N 150 1000 N 110 10,000 N 75 100,000 N 50

  • Flows between isolated and non-isolated loops will be an order of magnitude different.

I I

I 2-18 I

TABLE 2-4 Integrated Primary to Secondary Leakage and MSSVs Releases Plant Class Integrated Primary to Integrated MSSVs Secondary Leakage at 1800 Releases at 1800 Seconds, lbm Seconds, lbm With W/0 Upper With W/0 Upper Upper Head Head Upper Head Head Operating 69,000 63,4000 87,330 67,400 3410 Mwt 65,300 61,400 85,100 83,200 3800 Mwt 80,300 77,300 110,000 97,300 2-19

t'

  1. 0 l

l l

TOP 0F REACTOR VESSEL 2000 LIQUID VOLlfE 1500 e

1@

WITH UPPER HEAD m

5

- - -- W/0 UPPER WAD U

500 TOP 0F HOT LEG e

0 I

I I

0 500 1000 1500 2000 TIME,SEC0f0S FIGURE 2-1 INADVERTANT OPENING OF AN ATMOSPERIC DlfP VALVE WITH LOSS T OFFSITE POWER REACTOR VESSEL LIQUID WLLNE VS TIME 2-20

{

l 1563 i

i i

TOP 0F REACTOR VESSEL

";d250 WITH UPPER HEAD W/0 UPPER HEAD d

5 938 LIQUID VOLUME

/

l

=

$625

~

S8 O 312 l

( TOP OF HOT LEG, 0

0 100 200 300 400 500 TIME, SECONDS c

FIGURE 2-2 STEAM LINE BREAK WITH LOSS OF 0FFSITE POWER OPERATING PLANTS REACTOR VESSEL LIQUID VOLUME VS TIME

[

2-21

i I

2500 g

j i

i l

T m

a-2000 WITHIPPERHEAD W/0 !PER HEAD w

Mom m

1500 W

t z

L l

I m

o l

E 1000 -i w

500 0

I I

I O

100 200 300 400 500

TIME, SECONOS FIG!PE 2-3 STEE LINE BREAK WITH LOSS OF 0FFSITE POfR
l., '

OPERATING PLANTS RCS PRESSURE VS TIE B

6 e

2-22

50

..._._._..,_..._.,_..;m.._.._...

."---::=.:. - ~!. _ __ _ t ~

~

.__4 W{

~ ~ -

4

..1__~.'.....

l

..._ q __.._ r=t-t==n...

W0. UPPER HEAD- --.-

_ _ __la e._:=4--

.... __. ir '- - l 1 -M-d=ir.ziff:"p7

.. :_ _:.W'_-$D - _. __ _ ;,,,-N..i.__.'.__=,. 3.;s M ITu:-5 40

=__..-.r....... _,...__.._...._..,.

p_

_..j

7. _-- t._..._ m ;_..-

L.

g 3_.__

r:iTCE : !E_. =.-. _i: :: _--i--:---

..-. "- =.-.*==.=-:=

2 rr= f -'

r r: u r.;; - __r- - r:._

rr : = : - -" n.___--.

. _.. t _.- u==:= t : =.:n =__= c: -

- - r m :. p=.1 = t== t=:.t=.==

g

=*,..___.o 4-_.___,..

_ _ I = - "== ' =_=.d =.= =I" 30

- ;~ = ', _~= =. '.,' =___"_ "_4 _ ___......._

=

r---

- = t.:___ i.._ _. 4

. _-t-1__ ____. i _ i___ b. =_ t- -- -

= _..

...._;g.__ _..

_._.g.____._.

...__ _p,. r.

.o t _.y.-

__.._____t._.__..a.___._,.__a_.

.== J E n.-i== =t t_--- p ;;

.1 _ __. t.._.. _ J- - - r 1 r_- c.. j _. i r.-

_.. - -m =. _ g----._n._. _.,. w

=--

a :_..

20

.. = _ ', --

'------_~___7-., _

-. =.,. _ -,

-~.

w

_ + _....

y-,

..-)_...,___t-------*

  • ----'----&------t---:----'--+__-=--

. _. _.. t:=--! :.. _ rt:

,_..a _.-

. =r -.

r==_. t.__..--)

= = =- ; _ =-= z _ + _ _ -..v.. _. _,.

e._.. _. /=

"-~=_._.___"_,__,__U-_.__,'._......2=='===E 10

..._l_._.

p

4..__

__b_._.___.:.__....i

/i.

_._I-..4-

__.-r----------

- / -- *

~~::- :.e = =.-._._-

p._..._.r.~':-.

L._

-,____-._____t==l-n_.

-~-

_. =;__.

, _. 2-. ]._.. _..._....*f"'.----._..--~l-.:-*.i7_.,__

= t.----..!! r___.._

-~~ l
;;..- ;

--+6 g

Q i

n- _;-. ;---

+-- *- T p

[. J. ----*

0 100 200 300 400 500 TIME,SEC t

FIGURE 2-4 STEAM LIE BREAK WITH LOSS T OFFSITE PWER OPERATING PLANTS SN ETY INJECTION Fl.0W VS TIME 1

f 2-23

~

125 i

i i

WITH UPPER HEAD

- - -- W/0 llPPER RAD 10C H

)

75---

9 5C w

~

33

  • . _ < c X Cl

.. g P-l C

ICL 200 3 C C "' s 400 5CC

TIME, SECCNCS FIGURE 2-5 STEAM LINE BREAK WITH LOSS OF 0FFSITE PCIER OPERATING PLANTS COR,E POlER VS TIE 2-24

f I

l 1

l TOP T REACTOR VESSEL 1000 _'

WITH UP3ER HEAD

- - - -h'/0 UPPE1 HEAD EE 5

l

$M LIQUID VOUJE b9 e 4W 5

l 200 TOP T HDT LE 0

0 50 100 150 200 250 TIE, SEC FIGURE 2-6 STEAM LIE BREAK WITH LOSS T TFSITE POKR 3410 MWT PLANTS REACTOR VESSEL LIQUID VOLlFE VS TIE 2-25

\\

2800

~

I 2400 WITH OPER EA1 W/0 UPER EAD 2000 5

fc

\\

,f 1600

'g i

1200 I

r

(~ ~~. ~

800 I

I I

I O

50 100 150 200 25C

TIME, SECCNCS FIGUE 2-7 STEAM LIE BREAK WITH IDSS OF TFSITE POER 3410 MWT PLANTS RCS PRESSURE VS TIE i

2-26 1

I

i 100 g

i i

i t

WITHUPPERHEAD W/0 UPPER {AD 80

~

I 60'-

,',,p__________________________

r i

oW 40

  1. .J

~

g 20 l

l 1

0 I

I I

O 50 100 150 200 25C TIME, SECONCS FIGURE 2-8 STEAM LINE BREAK WITH LOSS OF 0FFSITE PWER 3L110 MWT PLANTS i

SAFETY INJECTION RDd VS TIE 9

2-27

1

, o --

'0 1

1 i

r z

WITHUPPERliEAD u)

M 10C W/0UPPERHEAD La O_.

e tu 2

75--

o c.

LU e

O LJ gg __

23 _.

e


.........._W~~~-r---------3 0

I i

i 0

50 100 150 200 250

TIME, SECONCS FIGURE 2-9 STEAM LINE BPEAK WITH LOSS OF 0FFSITE POWER 3410 MWT PLANTS COREPOWERVSTIE

)

I 2-28 i

p --._ -

f M

I I

I I

.r-TOP W REACTOR VESSEL

---_L-------..--.-------

WITH UPPER W AD 2000

--- WO UPKR WAD LIQUIDV0UIE "1500

~

4

$1000 E

s

._ g 500 e8U TOP OF HOT LEG

[n 0

n i

I 0

100 200 300 400 500 l

TIME, SECONDS FIGURE 2-10 STEAM LIE BREAK WITH LOSS T TFSITE PWER 3800 MWT PLANTS REACTOR VESSEL LIQUID VOLlliE VS TIE 2-29

= = - - -

2500 i

i l

5 WITH UPPER HEAD W/0 UPPER HEAD e

a-2000 --

\\

e 1

aa g

m 1500 1

x

\\

i m

\\

u

\\

E 1000

~\\

~s 's N

~,

's s

~ ~ ~

500 O

I I

I I

O 100 200 300 400 500 TIME, SECONGS FIGURE 2-11 STEAM LINE BREAK WITH LOSS OF 0FFSITE POWER 3300 f1WT PLANTS RCS. PRESSURE VS_ TIME 2-30

200 i

I i

i WITH UPPER HEAD

-- --W/0 UPPER HEAD _

160 M

m 120 gij a

y' d

80 I

ts I

I l

40 I

~

l 0

I I

i 1

1 0

100 200 300 400 SCO TIME, SECCMOS 1

FIGURE 2-12 STEAM LINE BREAK WITH LOSS OF 0FFSITE POWER 3800 MWT PLANTS SAFETY INJECTION FLOW VS. TIME 2-31 es*.

.~

15C i

1 5 -

__ __. _- WITH UPER HEAD W/0 ~ UPPER HEAD zwu e

10C -

w 0

ocw 2

75 o

o_

w G:

o

~

u 50--

25 O--

0 i

i O

100 200 300 400 5CC TIME, SECONCS FIGURE 2-13 STENi LINE BREAK WITH LOSS OF 0FFSITE MER 3800 MWT PLANTS COREPOWERVSTIME

,.m..,

h -

  • ~

2500 i

i i

I

\\

WO MIXING

-- - - WITH MIXING _

2000

's a

's s G

1500

~~s c-

~

u3

~

g

~..

12W 100C-ene 500 0

I I

I I

0 100 200 300 400 500 TIE, SEGNDS FIGlRE 2-14 STEM LIE BREAK WITH LOSS OF 0FFSITE POWER 3800 MWT Pl. ANTS (MIXING EFFECT)

RCS PRESSUE VS TIE l

l 2-33 I

G

l 200 i

1 1

W/0 MIXIh'G 160

- - - - WITli MIXING y

120 E

B u_

g 80

,s'

('

40 i

l I

O I

I I

I I

0 100 200 300 400 5C0

TIME, SECONOS FIGlRE 2-15 STEN 1 LIE BEAK WITH LOSS OF 0FFSITE F0htR 3800 MWT PLANTS (MIXING EFFECT)

SAFETY INJECTION FL0d VS TIE 2-34

150 I

125 W/0 MIXING -

r

_ _ _ __WITH MIXIhG zw oe 100 w

CL ew 2

75 "

o weoa 50 I

25-K 0

I i

0 100 200 30C 400 500 TIME, SECONCS FIGURE 2-16 STEAM LINE BREAK WITH LDSS T TFSliE P(MER 3800 MIT PLANTS (MIXING EFFECT)

CmEPOKRVSTIME f

2-35

\\

f 1500 l

l l

l l

TOP 0F REACTOR VESSEL 1250 m

tZ 1000 S

'd

?5 h750 LIQUID VOLUME 8

J W5 EE 500 WITH UPPER HEAD e


W/0 UPPER HEAD E

-3 250--

TOP OF HOT LEG


f 0

I l

l I

I 0

300 600 900 1200 1500 180 TIME, SECONDS FicuRE 2-17 STEAM GENERATOR TUBE RUPTURE WITH LOSS OF 0FFSITE POWER OPERATING PLANTS REACTOR VESSEL LIQUID VOLUME VS TIME 2-36

^

r i

i i

2500 l

l l

l l

WITH V3) R HE0 WO UP3-k EA) 2200 1900 1

l h1600 1

~

t E

1300 i

I

's% ~ - -. _ _.

1000 700 l

l l

l l

0 300 600 900 1200 1500 1800 TIME, SECONDS FIGURE 2-18 STEAM GENERATOR TWE RUPTURE Willi LOSS T OFFSITE POWER OPERATING PLANTS RG PESSWE VS TIE 2-37

120 i

i l

WIE UPPER HEAD 100

-- --W/0 UPPER HEAD 80 y 60 Ei.

N 40

,~

/

-N N

I I

x I

N 20 g

i I

l 0

I I

il I

0 300 600 900 1200 1500 1800 TIME, SE(DNDS FIGURE 2-19 STEM GEfERATOR TUBE RUPTURE WITH LOSS T OFFSITE PCWER OPERATING PLANTS SMETY. ItUECTION FLOW VS TIME 2-38

l l

l l

l l

TOP OF REACTOR VESSEL F

1000 WITH UPPER HEAD 1

- - -- W/0 UPPER HEAD y

-800 S

LIQUID VOLUME as z

W 600 8

E

=5 S 400 EL l

5 3

200 TOP 0F HOT LEG I

I 0

0 300 600 900 1200 1500 1800 TIME, SECONDS FIGURE 2-20 STEAM GENERATOR TUBE RUPTURE WITH LOSS OF 0FFSITE POWER 3410 MWT PLANTS REACTOR VESSEL LIQUID VOLUME VS TIME 2-39

i i

i l

l 2400 WITH IPPER HEAD W/0 UPPER HEAD g

1900 g 1650 l

g 1400

\\N

's

' 'w m >

1150 l

I I

I I

900 O

300 600 900 1200 1500 1800 TIE, SEC0f0S FIGURE 2-21 STEAM GEERATOR TUBE RUPTWE WITH LOSS OF 0FFSITE POWER 3410 MWT PLANTS RCS PRESSURE VS TIE 2-40

120 i

i i

l WITH LPPER EAD 100 WO LPPER EAD v80 in b

h60

~ ~ ' ' =

/

,'l

/

A 40

/

(- w I

I I

20 l

I I

0 i

i il I

i

~

0 300 600 900 1200 1500 1800 TIE, SECONDS FIGlRE 2-22 STEAM GENERATOR TUBE RUPTURE WITH LOSS OF 0FFSITE POWER 3410 MWT PLANTS SAFETY INJECTION FLOW VS TIME 2-41

2500 i

i i

i i

/

TOP 0F REACTOR VESSEL 2000 m

!Z LIQUID 1500 "i

VOLUME WITH UPPER HEAD W


W/0 UPPER HEAD

@1000 d

B a

A 500' 3

TOP 0F HOT LEG O'

l l

l l

l 0

300 600 900 1200 1500 1800 TIME, SECONDS FIGURE 2-23 STEAM GENERATOR TUBE RUPTURE WITH LOSS OF 0FFSITE POWER 3800 MWT PLANTS REACTOR VESSEL LIQUID VOLUME VS TIME 2 42

2500 i

i l

1 I

2250 WITH LPRR RAD

- - - -- W/0 LPRR HEAD 2000._

's e

k 1750

'z E

i s

n, n w

$ 1500

/

\\

/

N~l

\\

.1250 4

1000 l

l l

l 0

300 600 900 1200 1500 1800 TIE, SE00NDS FIGlRE 2-24 l

STEAM GEERATOR TlBE RlPTURE WITH LOSS OF 0FFSITE PNER 3800 MWT PLANTS RCS PRESSlRE VS TIE 2-43

120 l

l l

l I

WITH IPPER EAD 100 W/0 DPPER HEAD

(s I

\\

i i

I

\\

l l

l 80 i

i 1

l

\\

l

\\

l

\\

r y

60 i

l

\\

l

\\

g l

x 40 l

'x l

l l

1 20-l I

l I

l l

I l

l l

l 0 0 300 600 900 E l)

MJ E0 TIE, SECONDS FIGURE 2-25 STEM GEEPATOR TUBE RlPTURE WITH LOSS E OFFSITE POWER 3800 MWT PLANTS SAFETY INJECTION FLOW VS TIE 2-44

1563 i

i i

i g TOP OF REACTOR VESSEL

~

1250 -

HOMOGENE0US UPPER HEAD mE

. HETEROGENEOUS UPPER HEAD 5

'i 05 938

[

LIQUID VOLUME B@

p-E 625

/

4

=

9 e

o S 312 a

TOP OF HOT LEG l

0 0

100 200 300 f400 500 TIME, SECONDS FIGURE 2-26 STEAM LINE BREAK WITH LOSS OF 0FFSITE POWER OPERATING PLANTS REACTOR VESSEL LIQUID VOLUME VS TIME 2-45

~~

2500 i

i 3

H0mGEE00S UPPER HEAD

- - -ETER0 GEE 00S UPPER EAD _

2000 tu x

D (D

m 1500 x

/-

a-

,L '

m u

E 1000

~

500 O

I l-1 I

O 100 200 300 400 500

TIME, SECONOS FIGURE 2-27 STEAM LINE BREAK WITH LOSS OF 0FFSITE P0fR OPERATING PLANTS

~

RCS PESSIK VS TIME-6 O

b 2-46

~

i i

i i

2500'

_ _ _ _ _ j _ _ TOP OF REACTOR VESSEL m 2000 T

5"i i_IQUID VOLUME g 1500 l

W g

$1000 d

HOMOGENE0US' UPPER HEAD caE HETER 0GENF0llS llPPER HEAD 3 500 TOP 0F HOT LEG 0

O 100 200 300

400, 500 TIME, SECONDS FidVRE 2-28 STEAM LINE BREAK WITH LOSS OF 0FFSITE POWER 3800 MWT PLANTS REACTOR VESSEL LIQUID VOLUME VS TIME 2-47

2500 i

i r

HOMOGENEOUS UPPER TAD e

HETEROGENEOUSUPPERHEAD m

a-2000 w

x D

m m

1500 we o_

mo" 1000 s

5G0 O

I I

I I

O 100 200 300 400 500

, TIME.

SECONGS FIGURE 2-29

~

SlFR1 LIFE BREAK WITH 1.0SS T TFSITE PD!ER

~

3800 MWT PLANTS RCS PRESSURE ys TIME i

2-48

I e

200 i

i i

I H010GBE00S LP R HEAD


HETEROGENEDUS UTER HEAD 160

~

120 M

80 b

h g

40

\\

N O

I I

1 k-0 100 200 300 400 500

TIME, SECONOS FIGlRE 2-30 STEAM LINE BREAK WITH LOSS OF 0FFSITE POIR p,

3800 MWT PLANTS SAFE 1Y INJECTION FLOW VS TIME s

I e

h l,

2-49

l 3.0 SIMULATION CAPABILITIES The C-E computer codes LTC (Reference 4) and CESEC (Reference 5) were used to generate all of the information related to normal operational transients, natural circulation cooldown transients, and SAR transients discussed in this report. The former code was used for the first two types of transients, while the latter one was used for the SAR transients. A brief summary on each code is presented below.

3.1 LTC LTC (Reference 4) is a one-dimensional, single-phase system simulation code which models the primary coolant system with 17 nodes and 20 flow paths (see Figures 3-1A and 3-18).

The code conserves subcooled liquid mass and energy in each node and momentum in each flow path. Cold leg asymmetries are not transported to the core or hot legs due to the existence of only series-connected flow paths in the reactor vessel regions.

The reactor coolant pumps are explicitly modeled.

The pressurizer is modelled as an inhomogeneous nonequilibrium node with phase variation. The reactor vessel closure head region is modelled as a two-phase node. The coupled equation set consists of 51 equations. Except for the pressurizer and vessel closure head nodes, the nodal mass, energy, and state equations are solved simultaneously with the internodal flow path momentum equations. The code does not inodel two-phase conditions outside the pressurizer and c'osure head, since one of its independent state variables is temperature.

LTC has been used in support of information presented in References 2 and 4.

~

The code has also been verified against experimental data including the Arkansas Nuclear One Unit 2 turbine trip test and the St. Lucie Unit I natural circulation cooldown event.

3.2 CESEC The CESEC digital computer program (Reference 5) prs.1 des for the simulation of a Combustion Engineering NSSS. The program, which calculates the plant response for non-LOCA initiating events for a wide range of operating 1

3-1

conditions, is used by C-E in NSSS and reload licensing analyses, to provide analytical support to the plant start-up tests, and in support of the development of plant emergency procedure guidelines and training packages.

CESEC assunes a node / flow-path network to model the NSSS. The RCS, consisting of the reactor coolant loops, the reactor vessel, and the pressurizer is divided into 26 nodes of constant volume. The nodal scheme given in Figures 3-2A and 3-2B was chosen to appropriately simulate the RCS component volumes and, thus, provide an adequate description of the spatial variation of the coolant properties. Node 26, which is the pressurizer node, is subdivided into a steam and a liquid region having variable volumes. The CESEC pressurizer model assumes the steam and liquid regions to exist in any one of the eight thermodynamic states specified in Reference 5.

The fluid in nodes 1 through 25 is assumed to be homogeneous and in thermal equilibrium. The nodal scheme for the reactor vessel allows for the effect of a temperature tilt in the reactor core to be explicitly accounted for during a steam line break event and other non-symmetric events.

During the rapid contraction of the primary coolant which takes place as a result of the limiting.depressurization events, the pressurizer empties and/or voids begin to form in the RCS. Since flow through the upper head is only a small fraction of the RCS flow, the temperatures in the upper head remain high and voiding first occurs there.

To some extent, the upper head itself then begins to perform the function of a pressurizer. Therefore, the reactor vessel upper head region is explicitly modeled in CESEC to more accurately predict the RCS pressure. The coolant flow from the upper plenum nodes (upstream half) to the vessel head node is specified by user input fractions.

The vessel head fluid returning into the outlet plenum nodes (downstream half) is assumed to be evenly distributed.

The thermalhydraulic model solves the conservation of mass and energy equations coupled with the equation of state for each control volume or node. There are 29 equations with 29 unknowns for the case that the pressurizer contains steam and liquid regions. For the case that only one phase exists in the pressurizer, the number of equations and unknowns is reduced to 28. A flow

(

model is used to determine the mass flow rate through each reactor coolant l

l pump.

The flow model calculates the mass flow rate through each reactor coolant pump. The model includes explicit simulations of the reactor coolant b

.c,

I 3-2 e

L

pumps and of the effects of natural circulation flow. The calculation is based on a solution of the one-dimensional momentum equation for each pump loop.

Each pump loop (4 in all) also considers the reactor vessel, a hot leg, and a steam generator. The loops are divided into a number of nodes whose densities, temperatures, and flows are obtained from the thermalhydraulic model. The flow model calculates the sum of the various forces around each loop. The forces acting on the fluid volume consist of (1) gravitational forces due to density and elevation changes around the loop (2) viscous o

forces due to wall friction and geometric expansions and contractions of the piping, and (3) forces due to the RCS pumps. A major assumption of the thermal-hydraulic model in CESEC is that the pressure around the reactor coolant loops and vessel is assumed to be uniform.

Assessment of CESEC by C-E includes comparisons of code predictions to existing experimental data for C-E operating plants (including the Arkansas Nuclear One Unit 2 turbine trip test and the St. Lucie Unit i natural circulction cooldown event) and to other C-E design codes. This information is presented in Reference 5.

4 3-3

G 3

6 x

A

\\

s.

Q)

\\ ~)>

(

I I!

(d O

<=

%) n an e

su

~

gE i.

20 IE e

IS is

,e

\\

U t

l i

l NY

'* b h#

g n

O

\\

\\

l

\\

,e i

3-4

(

i FIGURE 3-1B LTC VOLUME DESCRIPTION VOLUME 1

Upper Plenum i

2 Hot Leg and SG Inlet Plenum 3

Hot Leg and SG Inlet Plenum 4

SG Tubes 5

SG Tubes 6

Pump Suction Leg (plus 1/2 pump volume) 7 Pump Suction Leg (plus 1/2 pump volume) 8 Pump Suction Leg (plus 1/2 pump volume) 9 Pump Suction Leg (plus 1/2 pump volume) 10 Pump Discharge Leg (plus 1/2 pump volume) 11 Pump Discharge Leg (plus 1/2 pump volume) 12 Pump Discharge Leg (plus 1/2 pump volume) 13 Pump Discharge Leg (plus 1/2 pump volume) 14 Downcomer and Lower Plenum 15 Core 16 Upper Head 17 Pressurizer and Surge Line 4

3-5

d STEAMLINE U STEAMLINE f

S

^

e SG2 SG1 e FEEDWATER 26 WATER I

W fn

/

\\

/

\\

9 9

f 23 22 25 10 11 24 21 20 19 7

8 9

12 18 6

17 5

h g

15 3

SI SI LETDOWN CHARGING CHARGING SPRAY

-e -

a I PIf i fit 13 14 2

1 SI SI 16 4

[~. SPRAY LETDOWN HARGING CHARGING r

SI SI CESEC NODAL SCHEP.1E FIGURE 3-2A 3-6

e

' NODE PHYSICAL DESCRIPTION 1

COLD LEG A 2

UPSTREMi HALF OF INLET PLENUM (BEFORE FLOW MIXING) 3 DOWNSTREAM OF INLET PLENUM (AFTER FLOW MIXING) 4 COLP LEG B 5

CORE 6

UPSTREMI HALF 0F OUTLET PLENUM 7

DOWNSTREAM ll\\LF OF OUTLET PLENUM 8

HOT LEG 9

STEAM GENERATOR INLET PLENUM 10 UPSTRFAM HALF OF STEAM GENERATOR TUBES 11 DOWNSTREN! HALF OF STEXi GENERATOR TUBES 12 STEM 1 GENERATOR OUTLET PLE:.'JM 13 SAME AS 1 IN OTHER STEM! GENERATOR LOOP 14 SAME AS 2 IN OTHER STEK! GENERATOR LOOP 15 SAME AS 3 IN OTHER STEAM GENERATOR LOOP 16 SAME AS 4 IN OTHER STEN 4 CENERATOR LOOP i

17 SAME AS S IN OTHER STEM 1 GENERATOR LOOP 18 SAME AS.6 IN OT!ER STEAM GENERATOR LOOP 19 SAME AS 7 IN OTHER STFRi GENERATCR LOOP F

20 Sf_"_ f.S 9 IN OTHER STEAM.:.f5ERn0R LGOP 21 SAME AS 9 IN OTHER STEMi CENERATOR LOOP 22 SAME AS 10 IN OTHER STEMi GE:ERATOR LOOP 23 SM!E AS 11 IN OTHER STEM 1 GENERATOR Loup 24 SAME AS 12 IN OTHER STEMI GENERATOR LOOP 25 REACTOR VESSELUPPER HEAD 26 PRESSURIZER e

e FIGURE 3-2B PHYSICAL DESCRIPTION OF NODES bg 3-7

A_

m L_

ma J-s

-an

-+_.- -.

4.0

SUMMARY

The information presented in this report has addressed the issues identified in Section 1.2.

The conclusions from this effort are:

1.

Voiding in the reactor vessel upper head region is not expected for normal operational transients.

2.

Voiding in the reactor vessel upper head region may occur during natural circulation cooldowns. A rapid enough depressurization can result in the reactor vessel upper head region fluid temperature reaching saturation.

Additionally, during an asymmetric natural circulation cooldown voids may be formed in the isolated steam generator loop if the flow in that loop is stagnant and the RCS is depressurized below the isolated generator saturation temperature / pressure.

Voiding under any of these circumstances can be prevented by:

Allowing sufficient time for the fluid in the reactor vessel upper head a.

to cool prior to depressurizing the RCS, I

b.

Conducting non-symmetric cooldowns in a controlled manner so as to cool down the isolated steam generator before aligning shutdown cooling.

l I

i 3.

Volding in the reactor vessel upper head region will likely occur for depressurization events such as a double-ended break of a steam line and a double-ended break of a steam generator tube. However, the SAR analyses performed indicate that voiding is not extensive enough to uncover the reactor vessel hot legs. Additionally, voiding will not result in violation of the SRP requirements for these transients for all C-E plants.

4.

The consequences of non-uniform mixing in the reactor vessel upper head are of secondary nature when compared to the consequences from not explicitly modelling the reactor vessel upper head region.

5.

Hot spots have negligible effect on plant parameters and, more importantly, transient consequences.

4-1

Additionally, the evaluation concludes that any potential void formation during the transients addressed is not great enough to impair reactor coolant circulation or core coolability.

As a final remark, it can be stated that C-E's emergency procedure guidelines adequately address the potential voiding situations by stating that additional time is required to conduct controlled natural circulation cooldowns to prevent reactor vessel upper head voiding or stagnated loop voiding for non-symmetric cooldowns.

If voids are present, the guidelines provide very specific operator guidance for dealing with voids and mitigating their Consequences.

1 4

O 4

i l

4-2 l

l i

i I

5.0 REFERENCES

i 1.

NUREG-0737, " Clarification of TMI Action Plan Requirements", October, 1980.

2.

CEN-152, " Combustion Engineering Emergency Procedure Guidelines", June, 1980.

I 3.

Letter from R. W. Reid, NRC, to Licensees of B&W Plants, " Concern for i

4 2

+

Voiding During Transients of. B&W Plants", January,1980.

i 4.

CEN-128. " Response of Combustion Engineering Nuclear Steam Supply System to Transients and Accidents", May, 1980.

5.

LD-82-001 (dated 1/6/82), "CESEC Digital Simulation of a Combustion Engineering Nuclear Steam Supply System" December,1981.

6.

INP0 2/NSAC 16 " Analysis and Evaluation of St. Lucie Unit 1 Natural Circulation Cooldown", December,1980.

7.

"The Operator's Role and Safety Functions", W. R. Corcoran et al, Atomic i

Industrial Forum, March 9-12, 1980.

a F

i e

4 b

i 5-1

APPENDIX A Typicg C-E Emergency Procedure Guidelines Related to RCS Voiding a

A.1 General Guidelines During Depressurization Actions 1.

During the RCS depressurization, monitor for void formation.

Indications of possibilities of voids are:

a) A pressurizer level increase significantly greater than expected while operating auxiliary spray, b) A pressurizer level decrease while operating charging.

c)

If the PLCS is in automatic, an unanticipated letdown flow greater than charging flow.

2.

If voiding of the RCS is indicated, perform the following:

a)

Isolate letdown.

b) Stop the depressurization.

c) Stop the RCS cooldown.

d) Repressurize the RCS by operating pressurizer heaters or HPSI and charging pumps.

3.

If the void formation is suspected to be non-condensible gases, operate t'he reactor vessel head vent as necessary to eliminate the gases.

l 4.

When conditions permit, resume the depressurization to the shutdown cooling system (SCS) initiation pressure.

A-1

5.

Depressurize the RCS to SCS initiation pressure by manually operating auxiliary spray if the following criteria are satisfied:

a) The RCS has been cooled to SCS initiation temperature 300'F,and b) At least 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> has elapsed since the start of the cooldown.

Precautions l.

During all phases of the cooldown, monitor RCS temperature and pressure to avoid exceeding a maximum cooldown rate greater than Technical Specification Limitations.

2.

Evaluate condensate storage inventory. Conduct a plant cooldown and enter shutdown cooling prior to depleting condensate storage inventory. Actions for elimination of voids should only be taken if con &nsate inventory can sustain the extended cooldown to shutdown cooling entry conditions.

A.2 Asyanetric Cooldown Action 1.

If a steam generator is isolated, perform the following activities (listed in order of preference) to prevent voids from forming in the isolated steam gererator loop:

a)

If possible, restart one RCP in each loop to establish cooling of the isolated steam gene.*ator.

b) Periodically drain and refill the isolated steam generator with feedwater.

Precaution 1.

If cooling down by natural circulation with an isolated steam generator, an inverted AT (i.e., T higher than T ) may be observed in the idle h

c loop. This is due to a small amount of reverse heat transfer in the isolated steam generator and will have no affect on natural circulation flow in the non-isolated steam generator.

A-2

e e

e

< s

> ^

+'

e s

- +;'

a r

'p t

y COMBUSTION ENGINEERING, INC.

l 7-t w

. :n..

  • a 4

i g.

b 1:

4 4

A es g'

L'

[.

[;. ;

'P

, g:..

s,*

1 k

,9

?

t'

.g

  • *