-l 17 77)

, 1.lCENSEE EVENT REPORT Update Report. Previous Report Date:

~

CONTROL 8 LOCK: l 1

l l l l l 6

lh (PLEASE PRINT CR TYPE ALL REQUl%ED INFORMATION) lo i1l1

> a e Il LluCENsEE Dl RlS CooE l 3 l@l 0 l0 l- l0 l0uCENsE is ts l0 l0mumeER 10 l - l 0 l 0 l@ a 4as l 1 uCENsEl 1 l1Tvet l 1 l@l a l

s7c4Tsa@

l CON'T l0l1l 7 8

,"ouRCE lt @l 0 l 5 l0 l0 l0 l2 l4 19 @l 1 l 1 l 0 l 7 l 8 l 1 l@l 0 I 1 l 1 l 2 I A l 2__l@

60 El DOCKET NUMSER 88 69 EVENT DATE 74 7s REPORT DATE 80 EVENT DESCRIPTION AND PROSABLE CONSEQUENCES h Io l2l l While performing Auto Blowdown Permissive surveillance DIS 287-1, pressure switch PS3- I

,o,3, g 1554E would not operate at required pressure (Tech. Spec. Table 3.2.2) . The health and l

,n ,,,gsafety of the general public was not endangered. 2 vent was of minimal safety signifi- l lo isl lcance since redundant pressure switches were operable. This is the first occurrence of I loI6l l this type. l lo l7I l l lotalI l

? se a0

$cSE Co$E seCNE CouroNENT CoOE sut D'E S O l0l9l 7 8 l S l F l@ {@ l E l@ lI lN lS lT lR lU l@ l S l@ IZ l@

9 10 11 12 13 18 19 20

,_ stoUENTIAL OCCURRENCE REPORT REvtsloN LE RIRo EVENT YEAR REPORT No. CoOE TYPE No.

@ ,RE l8 l 1l l-l l0l3l6l l/l l0l31 y

(--.] W

_ 21 22 M 24 3 27 3 3 0 31 32 Hours 22 *

  • KN A P T M 5 e iTT 8. PL MA FC RER

[B J@lZ 33 34 l@ l Zi@

36 1 21 @

34 l010101oI IN l@

37 41 lY l@ lNI@ lMl2l3l5l@

40 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 jijollThe cause of the failure was a plugged instrument snubber. The snubber was cleaned l

,,,,,land the pressure switch operated properly. DIS 287-1 will continue to be performed l'

monthly. No further action considered necessary. I 1 i 131 l l 11 141 l l 7 s 9 80 A  % POWER oTHER STATUS isCo R DiscoVERv CEsCRIPTioN NA l1 i 5 l l_EJ@ l 0l 6 l 1 l@l l lBl@l Surveillance Test l AbviTV C$ TENT (ELEAst LOCATION oF RELEASE @

l1 l 6* *l l Z l @o ' on RELEASE AuouNTor NA lZl@lACTiv "

l Tv @ l NA l

  • ERsoNNEL ExposOEs "

NuweER

~[gily; l0l0l0l@lgl@lotsCRimoN @

Tvet NA l

' ' ' ,ERseN~ENuhs "

NuM8ER DEsCRimoN@

li t a8l 91010101@l12 7 11 NA I 80 TV E DEsCR o l1l9l 8 9

@l10 NA l 7 30 PuSLICITY NRC USE ONLY issufD l 2 l o l l N lhlDEsCRi*T1oN 7 8 9 10 NA l 67 69 ll llllll ll ll lf

30. g

. as 815-942-2920. Ext. 422 NAME OF PREPARER PHON E: {

O

. , R .- - -. -

i

~

. l

. SUPPLEMENT TO DVR DVP. NO. .

STA UNIT. YEAR N0 D- 12 , 3 . 81 74

~

PART 1 l TITLE OF EVENT OCCURRED Auto Blowdown Permissive Pressure Switch 3-1554 E 11-7-81 1100 n,e nf c21 f krn H nn DATE T IfiE I REASON FOR SUPPLEMEfiTAL REPORT Correct Occurrence Date on Licensee Event Report PART 2 l .

ACCEPTANCE BY STATION REVIEW M- [ ._

,Au

, u n ,- ntso SUPPLEMENTAL REPORT APPROVED /

AND AUTHORIZED FOR DISTRIBUTION , C0r . / [8L

.ST ON SUPERINTENDENT /

'DATE l

l e

.