Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML20210R6081999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Dresden Nuclear Power,Units 1,2 & 3.With ML20210D3071999-06-30030 June 1999 Corrected Page 8 to MOR for June 1999 for DNPS Unit 3 ML20209E1291999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20195G6381999-05-31031 May 1999 Monthly Operating Repts for May 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20206N2821999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20205N7491999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20207M6921999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20199C8951998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Dnps,Units 1,2 & 3 ML20197G8591998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Dresden Nuclear Power Station.With ML20195D2861998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Dresden Nuclear Power Station.With ML20154L3681998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20151Y2711998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20237A7161998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20236M6041998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20248M3021998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20247F3391998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20216C9651998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20216E2531998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Dresden Nuclear Power Station ML20202F7831998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Dresden Nuclear Power Station ML20198P5321997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Dresden Nuclear Power Station ML20203F8781997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Dresden Nuclear Power Station ML20199B0701997-10-31031 October 1997 Monthly Operating Repts for Oct 1997 for Dresden Nuclear Power Station ML20217H7201997-09-30030 September 1997 Monthly Operating Repts for Sept 1997 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20216J3781997-08-31031 August 1997 Monthly Operating Repts for Aug 1997 for DNPS ML20210H5511997-07-31031 July 1997 Monthly Operating Repts for July 1997 for DNPS IAW RG 1.16 & GL 97-02 ML20216J3991997-07-31031 July 1997 Revised Page 6 to Monthly Operating Rept for July 1997 for Dresden Nuclear Power Station,Unit 2 ML20216J3891997-06-30030 June 1997 Revised Page 6 to Monthly Operating Rept for June 1997 for Dresden Nuclear Power Station,Unit 2 ML20140D7401997-05-31031 May 1997 Monthly Operating Repts for May 1997 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20140D7461997-04-30030 April 1997 Revised Monthly Operating Rept for Apr 1997 for Dresden Nuclear Power Station,Unit 3 ML20141A9861997-04-30030 April 1997 Monthly Operating Repts for April 1997 for DNPS ML20137T3411997-03-31031 March 1997 Monthly Operating Repts for March 1997 for DNP ML20136G4521997-02-28028 February 1997 Monthly Operating Repts for Feb 1997 for Dresden Nuclear Power Station ML20134L6081997-01-31031 January 1997 Monthly Operating Repts for Jan 1997 for Dresden Nuclear Power Station ML20133K4181996-12-31031 December 1996 Monthly Operating Repts for Dec 1996 for Dresden Nuclear Power Station Units 1,2 & 3 ML20132A9541996-11-30030 November 1996 Monthly Operating Repts for Nov 1996 for Dresden Nuclear Power Station ML20134K5681996-10-31031 October 1996 Monthly Operating Repts for Oct 1996 for Dresden Nuclear Power Station ML20128P5091996-09-30030 September 1996 Monthly Operating Repts for Sept 1996 for Dresden Nuclear Power Station Units 1,2 & 3 ML20149H1821994-10-31031 October 1994 Monthly Operating Repts for Oct 1994 for Dresden Nuclear Power Station ML20059G3771993-12-31031 December 1993 Monthly Operating Repts for Dec 1993 for Dresden Nuclear Power Station ML20058L5851993-11-30030 November 1993 Monthly Operating Repts for Nov 1993 for Dresden Nuclear Power Station ML20058G8151993-10-31031 October 1993 Monthly Operating Repts for Oct 1993 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20046D0311993-07-31031 July 1993 Monthly Operating Repts for July 1993 for Dresden Nuclear Power Station ML20045B1961993-05-31031 May 1993 Monthly Operating Repts for May 1993 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20035E5541993-03-31031 March 1993 Monthly Operating Repts for Mar 1993 for Dresden Nuclear Power Station Units 1,2 & 3 ML20044C0251993-02-28028 February 1993 Monthly Operating Repts for Feb 1993 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20128L1741993-01-31031 January 1993 Monthly Operating Rept for Jan 1993 for Dresden Nuclear Power Station ML20127E4761992-12-31031 December 1992 Monthly Operating Repts for Dec 1992 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20125E4061992-11-30030 November 1992 Monthly Operating Repts for Nov 1992 for Dnps,Units 1,2 & 3 ML20248J4221991-06-30030 June 1991 Monthly Operating Repts for June 1991 for Dresden Nuclear Power Station Units 1,2 & 3 ML20058H2911990-10-31031 October 1990 Monthly Operating Repts for Dresden Nuclear Power Station for Oct 1990 1999-07-31
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20249C8491999-09-30030 September 1999 1999 Third Quarter Rept of Completed Changes,Tests & Experiments Evaluated,Per 10CFR50.59(b)(2), for Dresden Nuclear Power Station. with ML20217A1691999-09-22022 September 1999 Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers ML20210R6081999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Dresden Nuclear Power,Units 1,2 & 3.With ML20209J3481999-06-30030 June 1999 1999 Second Quarter Rept of Completed Changes,Tests & Experiments, Per 10CFR50.59.With ML20209E1291999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20210D3071999-06-30030 June 1999 Corrected Page 8 to MOR for June 1999 for DNPS Unit 3 ML20195G6381999-05-31031 May 1999 Monthly Operating Repts for May 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20195B2591999-05-19019 May 1999 Rev 66a to CE-1-A,consisting of Proposed Changes to QAP for Dnps,Qcs,Znps,Lcs,Byron & Braidwood Stations ML20206N2821999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20205N7491999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20206B1901999-03-31031 March 1999 First Quarter Rept of Completed Changes,Tests & Experiments Per 10CFR50.59 for Dresden Nuclear Power Station. with ML20207M6921999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20207E9311999-02-26026 February 1999 Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced ML20199M0891999-01-22022 January 1999 Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc ML20199C8951998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Dnps,Units 1,2 & 3 ML20205M7061998-12-31031 December 1998 Unicom Corp 1998 Summary Annual Rept. with ML20199D3261998-12-31031 December 1998 10CFR50.59 SER for 1998-04 Quarter, of Changes,Tests & Experiments.With ML20197G8591998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Dresden Nuclear Power Station.With ML20196A4191998-11-19019 November 1998 Safety Evaluation Accepting QA TR CE-1-A,Rev 66 Re Changes in Independent & Onsite Review Organization by Creating NSRB ML20196J0061998-11-19019 November 1998 Rev 66 to Topical Rept CE-1-A, QA Program ML20195D2861998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Dresden Nuclear Power Station.With ML20154L3681998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20154N4131998-09-30030 September 1998 1998 Third Quarter 10CFR50.59 Rept, for Dresden Nuclear Power Station of Completed Changes,Tests & Experiments ML20153C5061998-09-21021 September 1998 SER Accepting Qualified Unit 1 Supervisor Initial & Continuing Training Program for Dresden Nuclear Power Station,Unit 1 ML20151Y2711998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Dresden Nuclear Power Station,Units 1,2 & 3.With ML20237E2331998-08-21021 August 1998 Revised Pages of Section 20 of Rev 66 to CE-1-A, QA Topical Rept ML20237A1341998-08-0707 August 1998 Safety Evaluation Supporting Amend 163 to License DPR-25 ML20237A7161998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20236M6041998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20236T8391998-06-30030 June 1998 Rev 1 to EMF-96-141, Dresden Unit 3 Cycle 15 Reload Analysis Rept ML20236F8131998-06-30030 June 1998 Rev 0 to Defueled SAR Dresden Nuclear Power Station Unit 1 Commonwealth Edison Co ML20236T8331998-06-30030 June 1998 COLR for Dresden Station Unit 3,Cycle 15 ML20236Q5851998-06-30030 June 1998 1998 Second Quarter 10CFR50.59 Rept, for Dresden Nuclear Power Station of Completed Changes,Tests & Experiments ML20248M3021998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20248F3531998-05-21021 May 1998 Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being Adopted ML20247F3391998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20217D0281998-04-22022 April 1998 Part 21 Rept Re Additive Constants Used in MCPR Determination for Siemens ATRIUM-9B Fuel by Core Monitoring Sys Were Found to Be non-conservative.SPC Personnel Notified All Customers w/ATRIUM-9B Lead Test Assemblies ML20216C9651998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Dresden Nuclear Power Station,Units 1,2 & 3 ML20216D4411998-03-31031 March 1998 First Quarter Rept of Completed Changes,Tests & Experiments for 10CFR5059 ML20216E2531998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Dresden Nuclear Power Station ML20203H2441998-02-25025 February 1998 Safety Evaluation Supporting Amends 166 & 161 to Licenses DPR-19 & DPR-25,respectively ML20203K5201998-02-25025 February 1998 Safety Evaluation Supporting Amends 165 & 160 to Licenses DPR-19 & DPR-25,respectively ML20202F7831998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Dresden Nuclear Power Station ML20199K1651998-01-23023 January 1998 Rev 65h to Topical Rept CE-1-A, Comm Ed QA Tr ML20202E2971998-01-0505 January 1998 Safety Evaluation Supporting Amends 164,159,179 & 177 to Licenses DPR-19,DPR-25,DPR-29 & DPR-30,respectively ML20198P5321997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Dresden Nuclear Power Station ML20198P7021997-12-31031 December 1997 Fourth Quarter Rept of Completed Changes,Tests & Experiments Per 10CFR50.59 ML20216D3611997-12-31031 December 1997 Unicom Corp 1997 Summary Annual Rept ML20203F8781997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Dresden Nuclear Power Station ML20199B0701997-10-31031 October 1997 Monthly Operating Repts for Oct 1997 for Dresden Nuclear Power Station 1999-09-30
[Table view] |
Text
._
Commonwealth Edison Company Dresden Generating Station 69N) North Dresden Road Morris, !!. 60 MO Tel Hl5-912-2920 May 11,1998 JMHLTR: #98-0138 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Monthly Operating Data Report for April 19.98 Dresden Nuclear Power Station Commonwealth Edison Company Docket Nos.50-010, 50-237, and 50-249 Enclosed is the Dresden Nuclear Power Station Monthly Operating Summary Report for April 1998.
This information is supplied to your office as required by Technical Specification 6.9. A.5, in accordance with the instructions set forth in Regulatory Guide 1.16. and Generic Letter 97-02.
Sincerely, h
i J
- 1. He e ite Vice Prei ent Dresden Stati l
Enclosure cc:
NRC Region Ill Office Illinois Dept. of Nuclear Safety, State ofIllinois l
NRC Senior Resident inspector, Dresden Station UDI, Inc. - Washington, DC File / Numerical-9905190291 990430 PDR ADOCK 05000010 R
pon j-[,) l-l li u
l
\\
A Unicom Company
]
r.
i l-
- /
- j. '
MONTHLY NRC l
SU14%RY OF OPERATING EXPERIENCE, PER REGULATORY GUIDE'1.16 FOR DRESDEN NUCLEAR POWER STATION CONNONWEALTH EDISON COMPANY FOR APRIL 1998 UNIT DOCKET LICENSE 1
050-010 DPR-2 2
050-237 DPR-19 3
050-249 DPR-25 I
i l
l l
L: 8360\\ 8301 \\ misc \\ 98\\ 98050501. GA 1
j
[
L___________.1._.
1 4
1 TABLE OF CONTENTS APRIL 1998 NRC REPORT 1.0 Introduction 2.0 Summary of Operating Experience 2.1. Unit 2' Month'ly-operating Experience Summary.
22 -Unit 3' Monthly Operating Experience Summary.
j 3.0 Operating Data Statistics 3.1 Operating Data Report - Dresden Unit 2 3.2-~
Operating Data Report - Dresden Unit 3 3.3 Unit 2 Shutdowns 3.4' Unit 3 Shutdowns 4.0 Unique Reporting Requirements 4.1 Main Steam' Relief and/or Safety Valve Operations -
Unit'2 and Unit.3 4.2 Technical Specification-Amendments 1
l l
l 1,: 8360\\8301\\ mise \\98\\98050501.GA 2
l I
i_______.._._..i._.__ _.. _ _ _.
A
, i_
.1.01 Introduction Dresden: Nuclear.. Power Station is a three reactor
~
- generating' facility owned and' operated by the Comed Company-of Chicago,-Illinois.
Dresden Station:is
-located at_the'confluenc'e'of;the Kankakee and Des J
.Plaines Rivers, in.'Grundy County, near, Morris,
-Illinois.
Dresden Unit 11 is.a GeneralLElectric Boiling; Water' Reactor.'with awdesign net electrical output rating of 200 megawatts electrical (MWe).
The' unit is=being decommissioned with all nuclear fuel removed from the reactor vessel.. Therefore, no; Unit:1 operating data is l
provided in this report.-
m Dresden Units 2 and 3 are General Electric Boiling-Water Reactors, each licensed at 2527 megawatts-thermal.
The gross outputs of Units 2 and 3 are 832 and.834 megawatts. electrical,-respectively,Lwith design.-
net. electrical' output.: ratings of 794 MWe each.
The
~
commercial service date for-Unit 2 is 11 August 1970,.-
and'30' October 1971 for. Unit 3..
Waste heat is rejected to,a man-made cooling-lake using.
the Kankakee River for.make-up and the Illinois River for blowdown.
~
The Architect-Engineer.for Dresden Units 2 and 3 was-
'l Sargent and Lundy of Chicago,' Illinois.
This report for APRIL 1998,.was compiled by Gary A.
Abrell of Dresden Regulatory Assurance Staff,. telephone number ~(815) 942-2920, extension 3749.
1 l
~
L: 8360\\8301\\ misc \\98\\98050501.ca 3
~
___:___1___.
i t
2.0
SUMMARY
OF OPERATING EXPERIENCE FOR APRIL 1998 2.1 UNIT 2 MONTHLY OPERATING EXPERIENCE
SUMMARY
Unit 2 began the period with core reload in progress.
Core' reload was completed at 2006 on April 1, 1998.
A reactor startup began at 2046 on April 15, 1998, and the reactor was critical at 0117 on April 16, 1998.
The unit was placed on system at 1606 on April 17, 1998, ending the refuel outage D2R15. The unit began power ascension and startup testing.
The unit tripped at 0858 on April 20, 1998, by a Generator Load reject signal. The load reject was the result of a design error that occurred during a recent modification to the unit auxiliary transformer. The unit was restarted at 1237 on April 22, 1998 following the root cause investigation and corrective actions.
The reactor was critical at 1751 on April 22, 1998, and placed on system at 1429 April 23, 1998.
Power ascension and startup testing resumed.
The unit reached full power at 2106 on April 27, 1998.
I 2
)
i Lt 8360\\8301\\ misc \\98\\98050501.GA 4
L
I 2.0
SUMMARY
OF OPERATING EXPERIENCE FOR APRIL 1998 2.2 UNIT 3 MONTHLY OPERATING EXPERIENCE
SUMMARY
Unit 3 began the period near full power. At 1522 on April 8, 1998, a Main Steam Line High Flow Switch failed during surveillance testing and Operators removed the fuse from that channel generating a half Group I isolation signal.
At 0040 on April 9, 1998, the reactor tripped when the Main Steam Isolation Valves closed. It was determined that the other Group I circuit opened momentarily as a result of a high resistance relay contact. Following a root cause investigation and corrective actions, the reactor was restarted at 1341 on April 13, 1998.
The reactor was critical.
at 1926 on April 13, 1998, and placed on system at 1653 on April 14, 1998.
The unit reached full power at 1630 on April 18, 1998, and remained at that load except for brief load reductions for minor maintenance and surveillance tecting.
l l
l L
'J.)h0 \\ B 301 \\ ml oc\\ 98 \\ 48 J50SOI.GA 5
l i
i
e.
l
,4 l
3.0 OPERATING DATA STATISTICS 3.1 OPERATING DATA REPORT - DRESDEN UNIT TWO DOCKET No.
050-237 DATE May, 1998 COMPLETED BY-G. A. ABRELL TELEPHONE (815) 942-2920 l
OPERATING STATUS 1.
REPORTING PERIOD:
APRIL 1998 2.
CURRENTLY AUTHORIZED POWER LEVEL (MWth):
2,527 MAXIMUM DEPENDABLE CAPACITY (MWe NET) :
772 DESIGN ELECTRICAL RATING (MWe Net) :
794 3.
POWER LEVEL TO WHICH RESTRICTED (MWe Net) : No restrictions 4.
REASONS FOR RESTRICTIONS (IF ANY):
See Section 2.1 of this report.
REPORTING PERIOD DATA l-l PARAMETER THIS MONTH YEAR TO DATE CUMULATIVE l
5 HOURS IN PERIOD 719 2,879 242,975 6 TIE REACTOR CRITICAL 302 1,774 17b,781 7 TIE REACTOR RESERVE SHUTDOWN (Hours) 0 0
t.
8 TIE GENERATOR ON-LINE (Hours) 242 1,697 168,451 9 TIE GENERATOR RESERVE SHUTDOWN (Hours) 3 3
4 10 THERMAL ENERGY GENERATED DerHt Gross) 431,171 3,843,154 353,606,577 11 ELucTRIcAL zwansy azuzRATED (bSRHe Gross) 133,358 1,248,730 112,982,56t 12 ELECTRICAL ENERGY GENERATED (MNEHe Net) 123,281 1,186,022 10b,866,197 13 REACTOR SERVICE FACTOR (%)
42.O%
61.61 72.8%
14 REACTOR AVAILABILITY FACTOR (%)
42.0%
61.b4 72.84 15 GENERATOR SERVICE FACTOR (%)
33.7%
58.9%
69.34 l
16 GENERATOR AVAILABILITY FACTOR (%)
34.1%
59.0%
69.31 17 CAPACITY FACTOR (Using MCD Net) - (%)
22.2%
53.41 57.0%
18 CAPACITY FACTOR (Using DER Net) (%)
21.6%
51.94 55.44 19 PDRCt.D OUTAGE FACTOR (%)
24%
9.64 12.74
\\
i l
L: 8360\\8301\\rnisc\\98\\9M 30bOI.GA b
3.0- OPERATING DATA STATISTICS 3.2 OPERATING DATA REPORT - DRESDEN UNIT THREE I
DOCKET No.
050-249 DATE May 4,1998 i
COMPLETED BY G. A. ABRELL TELEPHONE'.
(815) 942-2920 OPERATING STATUS l
l 1.
REPORTING PERIOD:
APRIL 1998 2.
CURRENTLY AUTHORIZED POWER LEVEL (MWth):
2,527 MAXIMUM 1 DEPENDABLE CAPACITY (MWe Net):
773 l
DESIGN ELECTRICAL RATING (MWe Net):
794 3.
POWER LEVEL TO WHICH RESTRICTED: No restriction i
4.
REASONS FOR RESTRICTIONS (IF ANY):
See Section 2.2 of this report.
REPORTING PERIOD DATA E
PARAMETER THIS MONTH YEAR TO DATE CUMULATIVE HOURS IN PERIOD 719 2,879 232,295 1
T M REACTOR CRITICAL 606 2,766 164,707 TIME REACTOR RESERVE SHUTDOM4 (Hours) 0
-0 0
T M GENERATOR CN-LINE (Hours) 584 2,744 157,168 TM GENERATOR RESERVE SHUTDolet (Hours) 0 0
0 l
THERMAL ENERGY GENERATED (16fHt Gross) 1,383,637 6,683,543 329,888,516 ELECTRICAL ENERGY GENERATED (MNEHe Gross) 452,445 2,186,305 105,674,464 ELECTRICAL ENERGY GENERATED (>54EHe Net) 433,588 2,103,511 100,210, 42 fl REACTOR SERVICE FACTOR (%)
84.3%
96.1%
70.91 REACTOR AVAILABILITY FACTOR (%)
84.3%
96.1%
70.9%
GENERATOR 8ERVICE FACTOR (%).
81.2%
95.3%
67.74 GENERATOR AVAIIABLILITY FACTOR (%)
81.2%
95.3%
67.7%
CAPACITY FACTOR (Using ICD Net) (%)
78.1%
94.6%
55.9%
CAPACITY FACTOR (Using DER Net) (%)
76.0%
92.01 54.3%
l FORCED OUTAGE FACTOR (%)
18.81 4.71 14.2%
t La 8360\\ 8301\\ misc \\ 98\\ 96050501.GA 7
{
l l
L____--____.___-_____
4 j
Y 3.3-UNIT 2 SHUTDOWNS REPORT MONTH OF APRIL'1998 NO DATE TYI'E DURATION REASON (2 METHOD OF.
CORRECTIVE ACTIONS /
(1)
(HOURS)*
).'
SHUTTING gg-COMMENTS REACTUM (3) 2 980307 S
398 C
1 D2R15 3
980420 F
'76 H
3 LER 2-98-008 i
Year-to-date forced outage hours==181 Cumulative forced outage hours = 24,609 TABLE KEY:
(1)
(3)
- F:.
Forced Method:
- S:
Scheduled
- 1. '
Manual 2.
Manual Scram (2) 3.
Automatic Scram Reason:
4.
Other (Explain)
A Equipment Failure (Explain).
5.
Load Reduction B'
Maintenance or' Test.
C-Refueling D
Regillatory Restriction.
.)
E Operator Training &
j Licensing Exam
-j F
Administrative G-Operational Error H~
. Other (Explain)
I I
I l
i L 8360\\8301\\ misc \\98\\98050501.GA O
l
e C
l j
'3.4 UNIT 3 SHUTDOWNS REPORT MONTH APRIL 1998 NO DATE TY F'E (1 )
DURATION REASON (2)
METHOD Of CORRECTIVE (HOURS)*
SHUTTING ACTIONS /
DOWN COMMENTS RCACTOR (3) 1 980409 F
135 A
3 LER 3-98-003 Year-to-date forced outage hours = 135 Cumulative forced outage hours = 26,075 q
TABLE KEY:
(1)
(3)
F:
Forced Method:
S:
Scheduled 1.
Manual 2.
Manual Scram (2) 3.
Automatic Scram Reason:
4.
Other (Explain)
A Equipment Failure 5.
Load Reduction (Explain)
B Maintenance or Test C
Refueling D
Regulatory Restriction E
Operator Training &
j Licensing Exam F
Administrative l
G Operational Error H
Other (Explain)
L: 83f.0\\ B301 \\rni se\\ 48\\ 98050501.GA 9
l 4.0 UNIQUE' REPORTING REQUIREMENTS 4.1-MAIN STEAM RELIEF AND/OR SAFETY VALVE OPERATIONS -
UNIT 2.
Four safety valves were overhauled and lift tested at the station prior to reinstallation on Unit 2.
On April 16, 1998 during the testing program following D2R15, Safety relief valves and the Target Rock valve f
were manually opened at low pressure in accordance with Dresden Operating Surveillance, DOS 0250-04
" Relief Valve Testing At Low And At High Pressure."
There was no activity on Unit 3 during the period.
- 4.2 Technical Specification Amendments Amendment 168 was implemented on Unit 2 prior to Mode 2 entry after D2R15.
This amendment changes the MCPR Safety Limit for Unit 2 to 1.09 from 1.08 to account for statistical uncertainties in the calculation for MCPR Safety Limit.
This is a single cycle amendment as reflected in the Design Feature Section of the Technical Specifications. A permanent amendment is pending approval which removes the single cycle restrictions on Units 2 and 3.
i 10 L \\8)fG830lMS(h9h97011001 (iA
__..