o,mnu,nxiiti siti..n o.nicam litt wirti (ervicr:tatig hiatiori (iMNi Norili litt sk si Iton!
Mottn ll.N4MI 1< l ns v> u vna December 8,1997 JSPLTR: #97-0209 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Monthly Operating Data Report for November 1907 Dresden Nuclear Power Station Commonwealth Edison Company Docket Nos. 50 010,50 237, and 50 249 linclosed is the Dresden Nuclear Power Station Monthly Operating Summary Report for November 1997.
This information is supplied to your omce as required by Technical Specification 6.9.A.5, in accordance with the instructions set forth in Regulatory Guide 1.16. and Generic Letter 97 02.
Sincerely, L
ft W 'tei ien Perry Site Vice President Dresden Station linclosure cc:
NRC Region til OMce Illinois Dept. of Nuclear Safety, State ofillinois k
f NRC Senior Resident inspector, Dresden Station UDI, Inc. Washington, DC File / Numerical
'2h,g 9712170479 971130 PDR ADOCK 05000010 R
PDR 1.1,I,l!Il,lill.!!!. l.l r
A l'ttN ofM OHilpJit)
t
,.j 4-i t
l.
l t
P MONTHLY NRC i
SUMARY OF OPERATING EXPERIENCE, j
3 PER REGULATORY GUIDE 1,16 FOR DRESDEN NUCLEAR POWER STATION t
CO6HONNEALTH EDISON COMPANY FOR NOVEMBER 1997
{
UNIT DOCKET LICENSE 1
050-010 DPR-2 2
050-237 DPR-19 3
050-249 DPR-25 t
t 1
- Lt\\t)60\\9301\\M180\\91\\970120401 GA
+
i i
i
?
P TABLE OF CONTENTS
.P NOVEMBER 1997 NRC REPORT i
1.0 Introduction 2.0 Summary of Operating Experience 2.1 Unit-2 Honthly Operating Experience Summary.
2.2 Unit 3 Monthly Operating Experience Summary.
3.0 Operating Data Statistics 3.1 Operating Data Report - Dresden Unit 2 3.2 Operating Data Report - Dresden Unit 3 3.3 Unit 2 Shutdowns 3.4 Unit 3 Shutdowns j
4.0 Unique Reporting Requirements f
4.1 Main Steam Relief and/or Safety Valve Operations -
Unit 2 and Unit 3
+
l I
i
\\
i 1
2 L t \\t M O\\ t 3 D n \\M1 sc\\t ? \\ t 10120401. GA
~... _ _ _.,. _. _.... -
i 4
i 1
i 1.0 Introduction Dresden Nuclear Power Station is a three reactor generating facility owned and operated by the Comed Company of Chicago, Illinois.
Dresden Station is located at the confluence of the Kankakee and Des l
Plaines Rivers, in Grundy County, near Morris, Illinois.
- t Dresden Unit 1 is a General Electric Boiling Water Reactor with a design not electrical output rating of 200 negawatts electrical (MWe).
The unit is being accommissioned with all nuclear fuel removed from the reactci vessel.
Therefore, no Unit 1 operating data is provided in this report.
Dresden Units 2 and 5 are General Electric Boiling Water Reactors, each licensed at 2527 megawatts
~
thermal.
The gross outputs of Units 2 and 3 are 032 and 834 megawatts electrical, respectively, with design not electrival output ratings of 794 MWe each.
The commercial service date for Unit 2 is 11 August 1970, and 30 October 1971 for Unit 3.
Waste heat is rejected to a man-made cooling lake using the Kankakee River for make-up and the Illinois River for blowdown.
The Architect-Engineer for Dresden Units 2 and 3 was Sargent and Lundy of Chicago, Illinois.
This report for NOVEMBER 1997, was compiled by Gary A.
Abrell of Dresden Regulatory Assurance Staff, telephone number (815) 942-2920, extension 3749.
)
3 l
1.t\\9360\\9301\\ Misc \\M \\t1012040),GA
'w-w-,
w e
r i
2.0 SLD64ARY OF OPERATING EXPERIENCE FOR HOVEMBER 1997 i
2.1 UNIT 2 MONTHLY OPERATING EXPERIENCE
SUMMARY
I, Unit 2 began the period near full power and l
remained at that level except for short periods i
for maintenance and surveillance' testing.
On_
November 15, 1997, a load _ drop to 150 MWE began in preparation for single. loop operation to replace i
2 the brushes on the 2A Recirculating Pump Motor Generator.
A drywell entry was made at low power to add oil to the 2B Recirc Pump._ The 2A Recirc i
Pump was restarted at 1530 on November 16, 1997, I
and a load increase began at 2030.
Load increase was halted early on the morning of November-18, l
1997 because of Feedwater Regulating Valve oscillations.
t Following valve repairs, the unit was brought'to
[
full power at-1630 on November 23, 1997.
1 J
i i
i.
Y-1 h
t P
'4-j-
tiusmosotuusnmnenowiu -
i
-1 l-.-.--
i
~
9 2.0 SUl44ARY OF OPERATING EXPERIENCE FOR NOVEMBER 1997 2.2 UNIT 3 MONTHLY OPERATING EXPERIENCE
SUMMARY
Unit 3 began the period at 515 MWE dropping load to begin a weekend outage to repair reactor coolant leakage in the drywell.
At 1900 on November 1, 1997, the turbine was tripped, and at 2000 the reactor was scrammed to complete the shutdown. A freeze seal was installed to repair a f ailed weld joint on the High Pressurc Flow Element Venturi Instrument Line on the B Recirc loop.
Upon completion of the repairs, reactor startup began about 2030 on November 4, 1997. The reactor was critical at 0055 on November 5, 1997. The unit was on system about 0400 on November 6, 1997, and at full load at 0900 on November 9, 1997.
i 1
5 t t \\l 160\\ 9 301 \\M!sc\\ li \\ t ? 012 0401. M
)
k r
3.0 OPERATING DATA STATISTICS 3.I OPERATING DATA REPORT - DRESDEN UNIT TWO DOCKET No.
050-237 DATE DECEMBER 4, 1997 COMPLETED BY G. A. ABRELL
"'ELEPl!ONE (815) 942-2920 OPERATING STATUS 1.
REPORTING PERIOD:
NOVEMBER 1997 2.
CURRENTLY AUTHORIZED POWER LEVEL (MWth):
2,527 MAXIMUM Dh,PENDABLE CAPACITY (MWe NET) :
772 DESIGN ELECTRICAL RATING (MWe Net) :
794 3.
POWER LEVEL TO WilICH RESTRICTED (MWe Net) : No restrictions 4.
REASONS FOR RESTRICTIONS (IF ANY):
See Section 2.1 of this report.
REPORTING PERIOD DATA l'ARAMET ER THIS MONTHiYEAR TO DATE CUMULATIVE 720 8,01f 239,352 6 HOURA IN PERIOD _
6 TIE REACTOR CRITICAL 720 7,1B1 174,34.1 7 TIM REACTOR 14.8ERVE &HUTDOWN (Hours) 0 C
8 TIM GENERATOR ON*LINE (Hours) 720 7,09; 16 6,10 ^1 9 TIW GENERATOR RESERVE SHUTDOWN (Hours) 0 C
1 10 THEM4AL ENERGY GENERA 1&D (NWHt Gross) 1,051,4bl 10,606,9be 34b,310,859 11 ELacTmicAL swamor onwsmATED (MNEHe Gross) b 4 0, 965 5,361,099 111,259,031 12 ELECTRICAL ENERGY GENERATED (MWLHe Net) 517,b4:
$,124,b21 105,226,250 13 REACTOR SERVICE FACTok (4) 100.0v b9.6%
72.06 14 REACTott AVAILABILITY TACTOR (t) 100.04 09.0%
72.84 15 GENERATOR SERVICE TACTOR (4) 100.0%
88.5%
69.46 16 GENERATOR AVAILABLILITY FACTOR (4) 100.04 88.St 69.4%
17 CAPACITY FACTOR (Using I G Net) (t) 93.1%
82.69 b6.94 15 CAPACITY FACTOR (Using DER Net) (4) 90.St 80.6%
bb.44 19 ft*CEn OUTAGE FACTOR (4) on 11.bv 12.89 6
ti \\l 360\\I l01 \\M18C\\ t1\\ t101204 t.. CA
i f
I e
i 3.0 OPERATING DATA STATISTICS 3.2 OPERATING DATA REPORT - DRESDEN UNIT Ti1REE DOCKET No.
050-249 DATE DECEMBER 4, 1997 COMPLETED BY G. A. ABRELL TELEPHONE (015) 942-2920 OPERATING STATUS 1.
REPORTING PERIOD:
NOVEMBER 1997 2.
CURRENTLY AUTliORIZED POWER LEVEL (MWth):
2,527 MAXIMUM DEPENDABLE CAPACITY (MWe Net):
773 DESIGN ELECTRICAL RATING (MWo Net):
794 3.
POWER LEVEL TO WHICH RESTRICTED: No restriction 4.
REASONS FOR RESTRICTIONS (IF ANY) :
See Section 2.2 of this report.
REPORTING PERIOD DATA PARAMETER THIS MONTH YEAR TO DATE CUMULATIVE 5
WO N IN PEA 100 720 e,olt 228,672 6
T1 2 RhCTOR Ch171 CAL 643 S:540.1 161,191
~
7 T12 AEACTok REstRVE sNUTuotrH (Houras o
0 0
8 TIM M E MTOR ON+L1 2 (Nours) ett 5,15e 163, t BC 9
TIS GEERATOR MSERVE SHOTDOtfN (Hours) 0 0
0 10 TWEst4A1. ENEROY otWLnATED (hsfut cross) 1,421,217 11,102,b39 321.37b,01t 11 stacf>2cAI. assseurr asMamArap (pessne erosel 463,019 3,615,822 102,eed,963 12 11.ECTRICAL RRRGY GP.MRATED (HbfEHe Net) 444,606 3,447,876 97,$30,379 13 NRACTOR stRVICE FACTOR (t) 89.39 66.6t 10.59 14 REACTOR AVAllAb1L17Y FACTOR (t) 69.33
- 66. o 70.St 15 eMamAfon stRVICE FACTOR (t) sS.o 64.36 67.29 16 WERATOR AVAILABLILITY I ACTok (t) 8S.6%
64.39 67.26 17 CAPACITY FACTOR (Using MCD Wat) (t) 80.04
$$.7%
$$.29 18 CAPACITY FACTOR (Using DER Net)
- d. t )
77.00 54.25 5 3. 'I t 19 FORCED OUTAGE I ACTOR (t) i
- 14. 4 tl 14.49 14.46 Y
}
w 7
Lt\\$360\\Il01\\ MISC \\t1\\t10110401.GA 1
e-
, -,,< --+-
m
_v.
' l l
I
- t t
3.3 UNIT 2 sNUTDONNS-
' )
REPORT MONTH OF NOVEMBER 1997 l
l NO DATE TYPE DURATION REASON METHOD CORRECTIVE
.j ACTIONS /
- l (1)
(HOURS)*
(2) 0F SHUTTING COMMENTS DowN REACTOR (3)
I
- l i
f y
i i
' l Year-to-date forced outage hours = 925 Cumulative forced outage hours = 24,331 l
TABLE KEY:
(1)
(3) k F
Forced Method:
i St Scheduled 1.
Manual i
2.
Manual Scram (2) 3.
Automatic Scram Reason:
4.
Other (Explain)
A-
. Equipment. Failure (Explain)
. 5.
Load Reduction B
. Maintenance or Test C
Refueling j
i D
Regulatory Restriction E
Operator Training &
Licensing Exam F-
-Administrative G-
. Operational Error' t
H
-Other'(Explain).
i i
8 i
- Li\\0 s60\\0 301\\ MISC \\91\\t10120401,GA --
i
L 3.4 tHIT 3 SHUTDOWNS REPORT MONTH NOVEMBER 1997 lJO DATE TYlt(1)
(AJPAT ION REASCW(?)
METHOD Cf COFILCTivt (HWPJ)*
SHV77!N3 AMIONS/
HN C#911.NTS i.,
6 971101 F
104 A
1 IER 97+01?
Year-to-date forced outage hours = 864 Cumulative forced outage hours = 25,940 TABLE XEY:
(1)
(3)
F:
Forced Method:
S:
Scheduled 1.
Manual 2.
Manual Scram (2) 3.
Automatia Scram Reason:
4.
Other (Explain)
A
'quipment Failure 5.
Load Reduction (Explain)
B Maintenance or Test C
Refueling D
Regulatory Restriction E
Oporttor Training &
Licensing Exam F
Administrative G
Operational Error H
Other (Explain) 9 Lt\\B360\\$301\\ MISC \\t1\\l10120401.GA
_ -. -.. ~. ~. -. - -. -.. -. - -...
n.
I i
l i
4.0
- UNIQUE MPORTING MQUIMMENTS i
i 4.1 MAIN STEAM MLIEF AND/OR SAFETY VALVE OPERATIONS - UNIT 2 f
AND UNIT 3 None t
r L
F r
r r
i F
F l
r l
l l
h l
l 1
I 10
~Lt\\tliO\\t301\\M:8C\\tt\\910120401,GA l
l-1
.c.
.. ~. -...
. _.,. -. ~... _.. _ _. _. _... _. _..., _.-
.