ML20028A575

From kanterella
Jump to navigation Jump to search
LER 82-022/03L-0:on 821012,circuit Breaker for Reactor Bldg Cooling Unit Fan XFN-62B Discovered Open & in Discharged Position.Cause Undetermined.All 480-volt Safeguard Switchgear Checked.Procedures Revised to Verify Position
ML20028A575
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/11/1982
From: Koon A
SOUTH CAROLINA ELECTRIC & GAS CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20028A574 List:
References
LER-82-022-03L, LER-82-22-3L, NUDOCS 8211220302
Download: ML20028A575 (1)


Text

, , _-_.-

+ .

'N M F18 4 Sid U.C. NUCL7AI) 021ULAT@QY C@MMISSIRN APPft 4VM tLY & M a

""" LICENSEE EVENT REPORT $'S E $eswa 1

CONTROL BLOCK: l l l l l l l@ (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) f oli ll s I ci

, S .

vl Cl sli l@l 0101 -10 l LaCENSE L8CENSEE CODE I. .5 01010101-NUMBER 10101@l 4l1 101010 l@l 35 .6 LIC E NSE TY PE 3.

I S. CAT 5.

l@

CON'T l o li l ""; "l, l Il@i0 l 5 l 010l 0l3 l 9 l 5 l@l 1l0 l 1 l 2 l 8 l2 l@l1 l 1l 1l1 l8 l 2 l@

y e .. .. DOCKETNUMBER .. .. EVENT D ATE .. .9 REPORT D ATE ..

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h Io12llWith the Plant in Mode 3. NRC Resident Inspector discovered that the circuit l l 013 l l breaker for Reactor Building Cooling Unit Fan XFN-62B was open and in the l l o I4 l l discharned position. The fan would not have started on an auto start sinnal. I I o Is l I There were no adverse consequences as the ' remaining selected fan was OPERABLE l o 6 l and both trains of Reactor Building Spray were OPERABLE. Also, the Plant was in l l o l 7 l l Mode 3 prior to initial criticality. l NI 'uiE "

ca .::mE e..P.NENT..DE .3:u S::mE I

l o 19 l l S l B I @ d,, 8 d,, 8 lC IK! Tl BlK lR l@ l Fl@ lZ l@

E.ENT. EAR

=T :/^.' *""" ": "" "mr """'.'*"

@ $"i" , l a 12 I l, l 101 212 I I/I 10131 I-I

_,, .. . .. ., .. .. L..lJ ,, L.o._I

= =": ::=, '==" M..R. . ."= u. . '"=P=-  :::,=R@

l,,xj @ L..aj @ I.z.J O L..zJ @ InIninio.J. .,

@:==@ L.,tJ L..uj@ L..aj @ b.. l 2 1 0 1 2 ,1.

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l 1 I o l l Event appears to be an isolated case for which cause has not been determined. l l 1 l 1 l l Fan functioned properly on October 7, 1982, during surveillance test with no l i 2 l subsequent maintenance on fan or breaker. Corrective action was taken to check j l i I a l l all 480V safeguard switchgear. No problems were discovered. Also, procedures l l i l 4 l l are being revised and developed to require signMf verification of position. l STAT S  % PO W E R OTN E R ST ATU*. D IS C O V E R Y DiSCOVENT DESCRIPTION I t l s l l B l @ l 0 l 0 l 0 l@l N/A l l D l@] NRC Inspection l RELE SED RELE ASE AMOUNT OF ACTIVITY LOC ATION OF R ELE ASE l il sl. .W @ W@l N/A l l N/A I

NUMBER TVPE D E S C R IPTION l1171lOl0lOl@[3J@l N/A l

PER.ONNEL iNJURIE S I il s .l .l 0101 Ol@l N/A l

'"," I' * " *D E S' RP "" = i*O' ' ' "@

l iI 9 I L. zj@l N/A l NRC USE ONLY i.suRE"'DESC RiPfiON h N/A I lll1Illllllll l 2 l a l L. sJ@l N AME OF PRFPA4Fn PHONE: (803) 345-5209 0211220302 821111 A. R. Koon. Ir.

PDR ADOCK 05000395 g PDR