ae' .

N JC FJN M 316

"*" U.C. NUCLE A A . 32U LAT2QY CRM MITITAM APPa&Vu;ts t Y @ MJ LICENSEE EVENT REPORT l' :MYa's.st .:

CONTROL BLOCK: l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

(1]

I oli ..l I q Cl y ClS l ligl0 l 0 l- l 0l0 r 010 l0 t- 10 P l@l 4 P I 0 1010 l@l,, o,i ..I @

mo........ .. .. um..E... .. .. u.E ...... ..

CONI l o li l " '!"[l Ll@l Ol 5 l 0lo.cnErnum.E. 010 l 3l 9 l 5l@l 014 l=v.=voar. 1l 4 l 813 ul@l n0I $ l 113 l 813 l@

, . .. .. .. .. . . .. . r . r . ..

EVENT DESCRIPTION AND PROBABLE CONSECUENCES h I o l: lI The Pressurizer Safety Valve Position Indication on valves XVR-8010-A/B/C failed l Lo p l l to function properly during the performance of a Channel Calibration. The Main l lo (4 l l Control Board indication of valve position was received during the sinulatal valve l jol5ll opening; however, the indication did not change once received. There were no l j o j e l l adverse consequences since alternate nethods of monitoring the valve position were l lo;7ll availabls for Operations personnel if the valves had opened while in Itdes 1, 2, j

" 3-to!.II I

'mc" E c':: . can, e. .. - ...E .::::s. .":n:,

lo!9 l l Il D j @ l Bj @ l A j @ l Il q $ 'Il Rl U j @ l S l @ l Z l @

, . . i. i. .. n .. .. ..

-E . E ., , o . unt,";'.".' *"=""" " m "' "';'t.' "

g '1"j".*,, l 8l 3 l

. . , n l _._ l n

l 0l 3 l6 l n ..

jfl

[ 0l3 l g..

l ._l l0 l u

'1:" 'w": ' ' " c' ' " " " ~~

..... @ ': = ,~,t"' ."; "" .. ", ;.L,1~'- c

"'n @

[_Aj@lFl@ lZl@ IZ i@ l 01 0 010 l l Ylh lNl@'lLl@ l- Cl 7 l 110ol n u n u n .. .. n u CAUSE DESCRIPTION AND CC RRECTIVE ACTIONS h l t l o l l The cause of the switch fail'ure was excessive current flow during contact l

l t l i l l closure. The current was a result of the discharge of the cable capacitance. l l t ! 2 i l The switch assenblies were replaced, and the circuit is being mcdified to I

, , j nclude a current limiting resistor nearby the switches.

i 'Ihe modification has j

, ,, , ; been tested and wil'1 prevent a future recurrence of this failure.  ;

.?A .  % OTM E R .T ATef. 1.COVERY .I.C OV E R Y D E.c aI#TIO N

  • l1l5ll l@l 0l3wER j0 [gl N/A l lB lgl Surveillance Tests l

, .. .. n u - o .

p KLE .ED RELE E AMOUNTOP ACTavtTY LOC ATION OF R ELE A.E l116ll lhl ..

lhl ,, -

l l l

" "'::" " ",',* 't " ". E . . . ..,,.2p 12 2115 0 l0 l@l Zlg; N 9

, . . .I .. .. ..

NWW.Em C Sca lPTtO N UU N/A liisil  ! l l@l l

, .. ii .. 8305200515 830513 ..

Lo.,. o r o. on E.-..c. .Einio" t o . c uv PDR ADOCK 05005395 N/A S PDR litsllr f @l l

I

... "'T Ec'. i.,io n @ NRC USE ONLY I :c !

18! .. . .

l l 111 l l l l l l ll 1 N ave Or FR: PARER -' M #F~

PHON (8 0 3 ) 345-5209 c.or. McKinney/ /