1 NUCl. EAR OPERA 10NS COPY N0.
SOUTII CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION CORE OPERATING LIMITS REPORT FOR CYCLE 12 REVISION 2 AUGUST 1999
- R'98881!?88L3 P
\\
LIST OF EFFECTIVE PAGES j
PAGE REVISION i
2 l
ii 2
iii 2
l' 2
2 2
3 2
4 2
5 2
6 2
7 2
8 2
9-2 10 2
11 2
12-2 13 2
14 2
15 2
16 2
17 2
18 2
19 2
20 2
21 2
22 2
23 2
24 2
25 2
26' 2
27 2
28 2
29 2
i 30 2
1 r
Table of Contents Section P_ age 1.0 Core Operating Limits Report............................................................................ 1 2.0 O pe ra t i n g Li mi ts............................................................................................
2 2,1 Moderator Temperature Coefficient (Specification 3.1.1.3).................. 2
)
1 2.2 Shutdown Rod Insertion Limits (Specification 3.1.3.5).........................
2 l
2.3 Control Rod Insertion Limits (Specification 3.1.3.6)..........
2 2.4 Axial Flux Difference (Specification 3.2.1)....................................... 2 l
(
Heat Flux Hot Channel Factor - F (z) (Specification 3.2.2)................. 3 2.5 9
2.6 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor - (Specification 3.2.3).................................................. 3
\\
2.7 Power Distribution Measurement Uncertainty (Specifications 3.2.2 and 3.2.3)............................................................... 4 3.0 References.....................................................................................................5 i
Revision 2
I
{..
List of Tables i
J l
(
)
Table fase
' Table 1.
RAOC W(z) at 150 MWD /MTU V. C. S ummer - Cycle 12......................................................................... 1 1 Table 2.
RAOC W(z) at 800 MWD /MTU V. C. Su mmer - Cycle 12............................................................................ 13 Table 3.
RAOC W(z) at 6000 MWD /MTU V. C. S umme r - Cycle 1 2.......................................................................... 15 Table 4.
RAOC W(z) at 10000 MWD /MTU V. C. S umme r - Cycle 12....................................................................... 17 Table 5.
RAOC W(z) at 20000 MWD /MTU V. C. S umme r - Cycle 12.......................................................................... 19 Table 6.
Baseload W(z) at 150 MWD /MTU V. C. S ummer - Cyc le 12......................................................................... 21 Table 7.
Baseload W(z) at 3400 MWD /MTU V. C. S umme r - Cycle 12..............................
....................................... 23 Table 8.
Baseload W(z) at 6000 MWD /MTU f
V. C. S um mer - Cycle 12......................................................................... 25 Table 9.
Baseload W(z) at 10000 MWD /MTU V. C. S um me r - Cycl e 12.............................................................................. 27 Table 10.
Baseload W(z) at 20000 MWD /MTU V. C. S u m me r - Cy cle 12............................................................................... 29 ii Revision 2
List of Figures Figure fage Figure 1.
Moderator Temperature Coefficient Versus Power Level V.C. S u m me r - Cycle 12.............................................................................. 6 Figure 2.
Rod Group Insertion Limits Versus Thermal Power for Three Loop Operation V. C. S u m me r - Cyc le 12.......................................................................... 7 Figure 3.
Axial Flux Difference Limits as a Function of Rated Thermal Power V. C. Su mme r - Cycle 12................................
.................................. 8 Figure 4.
K(z) Normalized F (z) as a Function of Core Height n
V. C. S u mme r - Cyc le 12..................................................................... 9 Figure 5.
RAOC W(z) at 150 MWD /MTU V. C. S u mme r - Cycle 12........................................................................ 10 Figure 6.
RAOC W(z) at 800 MWD /MTU V. C. S u mmer - Cycle 12................................................................ 12 Figure 7.
RAOC W(z) at 6000 MWD /MTU V. C. S u mme r - Cycle 12........................................................................ 14 Figure 8.
RAOC W(z) at 10000 MWD /MTU V. C. S u mme r - Cycle 12...............................................................
16 Figure 9.
RAOC W(z) at 20000 MWD /MTU V. C. S u mme r - Cycle 12...................................................................... 18 Figure 10. Baseload W(z) at 150 MWD /MTU V. C. S u m me r - Cycle 12............................................................... 20 Figure 11. Baseload W(z) at 3400 MWD /MTU V. C. S u mme r - Cy cle 12............................................................................ 22 Figure 12. Baseload W(z) at 6000 MWD /MTU V. C. S u m mer - Cycle 12.................................................................. 24 Figure 13. Baseload W(z) at 10000 MWD /MTU V. C. S u mme r - Cycle 12........................................................................ 26 Figure 14. Baseload W(z) at 20000 MWD /MTU V. C. Su mme r - Cycle 12.............................................................................. 28 Figure 15. RCS Total Flowrate Versus R for Three Loop Operation V. C. S u m me r - Cy c le 12.......................................................................... 30 iii Revision 2
' V. C. Summer Cycle 12 COLR, Revision 2 '
August 1999
- 1.0 Core Operating Limits Report This Core Operating Limits Repon (COLR) for V. C. Summer Station Cycle 12 has been prepared in accordance wit). 'he requirements of Technical Specification 6.9.l.11.
The Teci 2.ic_, Specifications affected by this report are listed below:
3.1.1.3 Moderator Temperature Coefficient 3.1.3.5 Shutdown Rod Insertion Limits 3.1.3.6 Control Rod Insertion Limits 3.2.1 Axial Flux Difference 3.2.2 Heat Flux Hot Channel Factor 3.2.3 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor 3.3.3.11 Power Distribution Measurement Uncertainty 1
Revision 2
V.C. Summer Cycle 12 COLR Revision 2 August 19h9' 2.0 Operating Limits The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the subsections which follow. These limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.11.
2.1 Moderator Temperature CoeNicient (Specification 3.1.1.3):
2.1.1 The Moderator Temperature Coefficient (MTC) limits are:
The BOUARO-MTC shall be less positive than the limits shown in Figure 1.
J 4
The EOUARO/RTP-MTC shall be less negative than -5x10 Ak/k/*F.
2.1.2 The MTC Surveillance limit is:
q 4
The 300 ppm /ARO/RTP-MTC should be less negative than or equal to -4.1 x10 Ak/k/*F where: BOL stands for Beginning of Cycle Life j
ARO stands for All Rods Out RTP stands for RATED THERMAL POWER EOL stands for End of Cycle Life
]
2.2 Shutdown Rod Insertion Limits (Specification 3.1.3.5):
The shutdown rods shall be withdrawn to at least 228 steps.
2.3 Control Rod Insertion Limits (Specification 3.1.3.6):
The Control Bank Insertion Limits are specified by Figure 2.
2.4 Axial Flux DiNerence (Specification 3.2.1):
2.4.1 The Axial Flux Difference (AFD) Limits for RAOC operation for Cycle 12 are shown in Figure 3.
2.4.2 The Axial Flux Difference (AFD) target band during base load operations for Cyclel2 is:
BOL - EOL (0 - 23,320 MWD /MTU): iS% about a measured target value.
2.4.3 The minimum allowable power level for base load operation, APLND,is 85% of RATED THERMAL POWER.
2 Revision 2
' V. C. Summer Cycle 12 COLR, Revision 2 August 1999 2.5 Heat Flux Hot Channel Factor - F (z) (Specincation 3.2.2):
n RTP Fq F (z)s x K(z).
for P > 0.5 q
p RTP F (z)s 05
- Rat d herma Power q
Ff = 2.40 2.5.1 2.5.2 K(z)is provided in Figure 4 2.5.3 Elevation dependent W(z) values for RAOC operation at 150, 800,6,000,10,000, and 20,000 MWD /MTU are shown in Figures 5 through 9, respectively. This information is sufficient to determine W(z) versus core height in the range of 0 MWD /MTU to EOL bumup through the use of three point interpolation.
2.5.4 Elevation dependent W(z)3t values for base load operation between 85 and 100% of rated thermal power with the item 2.4.2 specified target band about a measured target value at 150,3,400,6,000,10,000, and 20,000 MWD /MTU are shown in Figums 10 through 14, respectively. This information is sufficient to determine W(z)st versus core height for burnups in the range of 0 MWD /MTU to EOL burnup through the use of three point interpolation.
N 2.6 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor - F3H (Specification 3.2.3):
N AH Thermal Power where: P = Rated Thermal Power R=
RTP N
p x ;, pp x (1 - P)
All AH RTP 2.6.1 F
= 1.62 3g 2.6.1 PF3g = 0.3 2.6.3 The Acceptable Operation Region from the combination of Reactor Coolant System total flow and R is provided in Figure 15.
3 Revision 2
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 2.7 Power Distribution Measurement Uncertainty (Specifications 3.2.2 and 3.2.3):
)
If the Power Distribution Monitoring System is OPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, Upan, to be applied to the Nuclear Enthalpy Rise Hot Channel Factor N
F shall be calculated by the following formula Ugy UFAH = 1.0 + 100.0 when:: UAH = Uncertainty for enthalpy rise as defined in equation (5-19) in Reference 1.
If the Power Distribution Monitoring System is OPERABLE, as defined in Techincal Specification 3.3.3.11, the uncertainty, Upg, to be applied to the Heat Flux Hot Channel Factor F (z) shall be 9
calculated by the following formula Un, Upq =
1.0 + 100.0, e
where: Uq = Uncertainty for power peaking factor as defined in equation (5-19) in Reference 1.
U,
= Engineering uncertainty factor.
= 1.03 If the Power Distribution Monitoring System is INOPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, UFAH, to be applied to the Nuclear Enthalpy Rise Hot N n hall be calculated by the following formula Channel Factor F s
UFAH = UFAHm where: U
= Base Fan measurement uncertainty.
FAHm
= 1.04 If the Power Distribution Monitoring System is INOPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, Upg, to be applied to the Heat Flux Hot Channel Factor F (z) shall be calculated by the following formula i
n i
UFQ = Uqu U, where: U
= Base Fq measurement uncertainty.
= 1.05 U,
= Engineering uncertainty factor.
=1.03 i
4 Revision 2
V. C. Summer Cycle 12 COLR, Revision 2.
August 1999 4
3.7 References
- 1) WCAP-12473-A (Non-Proprietary), " BEACON Core Monitoring and Operations Suppon System", August,1994.
5 Revision 2
F
]
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 4. Moderator Temperature Coenielent Versus Power Level V.C. Summer - Cycle 12 1.00 0.90 Unacceptable Operation 0.80 C
b2 0.70 To 0
l j 0.60 3
Acceptable j
Operation 0 0.50 E
)
3 8 0.40 E
0 8
lii3 0.30 3o2 0.20 0.10 0.00 O
10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power 6
Revision 2
' V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 5. Rod Group Insertion Limits Wrsus Thermal Power for Three Loop Operation V. C. Summer - Cycle 12 230 I lillilllll
/
220 (0.54,228) l j
I l----
210
/
200
/
(1.0,194) r f
)
190 1
180
?
/
J f
BANK C
/
170
/
y f
160
/
J p
150
/
/
c J
i 2 140 t
l
/
/
f g 130 j
I 120 j
/
Gi (0.0,118)
/
n.110
/
1 0' 100 f
3 90 j
BANK D x
/
/
80 j
/
70
/
/
60 j
50 j
40
/
j 30 j
20
/
)
d 10 ----p (0.048, 0) 0 O.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Fraction Of Rated Thermal Power 7
Revision 2
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 6. Axial Flux Difference Limits as a Function of Rated Thermal Power V. C. Summer - Cycle 12 120
(-8,100)
(+8,100) 100
/
\\
L Unacceptable
[
k Unacceptable
/
\\
3 80 g
/
\\
E
/
Acceptable
)
a
\\
E
/
\\
3
/
\\
E b
f
\\
lii J
\\
/
\\
(-22, 50)
(+20, 50)
B n.
40 20 0
-40
-30
-20
-10 0
10 20 30 40 Axial Flux Difference (% AI) 8 Revision 2
1 1
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 l
Figure 4. K(z)- Normalized F (z) as a Function of Core Height n
V. C. Summer - Cycle 12 1.10 (0.0,1.0)
- (6.0,1.0)
(12.b,0.92hi) 0.90 0.80 i
j J 0.70 uJ E
g, p
g
- u. 0.60
]
y e
g o
Z n
N
- 0.40 M
0.30 1
i 0.20
..~........
4 0.10 l
0.00 0
2 4
6 8
10 12 Bottom Core Height (Feet)
Top 9
Revision 2
V. C. Summer Cycle 12 COLR. Revision 2 August 1999 Figure 5. RAOC W(z) at 150 MWD /MTU V. C. Summer - Cycle 12 1.50
..s..,u.....
..>..s,..
....s...>..s..
.........s,..
1.45 +..... +.
+-
4
..r....+....s...r.......s...s..
....s...>..s..
.....>..>..........s...
+
1.40 y
..r.....
..s.........
..>..s......s...>..s..
..,......+.
3...,....
1.35 p
- h. t.. r...
..:..t..r..
..... a... t.........:..:.........
.. r..........
i 1.30 i
.....u......
..u..
..s..
.....s...
n
- 1.25
..s.+
.....s.........s...r..
.....s......
1.20 3...,...,..
3..
,... s... s.. r.....>..>..s.........>..>..........s...
..r.....>....s...,...
n..........
+.,....
O 1.15
..r....>....n.........
..r..
...>..s.......s...>..........>..
....,.... s.... g.
n. _.,. m.,%.....,...,...
a.....++ M o,.
1.10 q.
v.......+..
.........,. +...
..... +
..t..r...
..:..t..r..
..:..t..
1...
..r.......
1.05
.....u.....
..>..s..u.
..s......s.......s.....
1.M 0
2 4
6 8
10 12 Bottom Core Height (Feet)
Top 10 Revision 2
1 V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 1. RAOC W(z) at 150 MWD /MTU V. C. Summer - Cycle 12 Core Height (ft)
W(z)
Core Height (ft)
W(z) 0.00 1.4389 6.08 1.1125 0.16 1.4385 6.24 1.1143 0.32 1.4452 6.40 1.1156 0.48 1.4590 6.56 1.1160 0.64 1.4700 6.72 1.1159 0.80 1.4671 6.88 1.1155 0.96 1.4574 7.04 1.1149 j
1.12 1.4460 7.20 1.1143 1.28 1.4316 7.36 1.1139 1.44 1.4151 7.52 1.1139 1.60 1.3971 7.68 1.1135 j
1.76 1.3774 7.84 1.1123 1.92 1.3562 8.00 1.1103 2.08 1.3343 8.16 1.1079 2.24 1.3122 8.32 1.1048 2.40 1.2894 8.48 1.1004 2.56 1.2656 8.64 1.0947 2.72 1.2424 8.80 1.0900 2.88 1.2231 8.96 1.0899 3.04 1.2088 9.12 1.0904 i
3.20 1.1985 9.28 1.0918 3.36 1.1916 9.44 1.0935 3.52 1.1862 9.60 1.0933 3.68 1.1807 9.76 1.0907 3.84 1.1746 9.92 1.0895 4.00 1.1675 10.08 1.0916 4.16 1.1599 10.24 1.0969 4.32 1.1535 10.40 1.1016 4.48 1.1496 10.56 1.1041 4.64 1.1468 10.72 1.1048 4.80 1.1433 10.88 1.1048 4.96 1.1390 11.04 1.1056 5.12 1.1345 11.20 1.1059 5.28 1.1298 11.36 1.1035 5.44 1.1241 11.52 1.0903 5.60 1.1171 11.68 1.0740 5.76 1.1111 11.84 1.0610 5.92 1.1109 12.00 1.0490 11 Revision 2
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 6 RAOC W(z) at 800 MWD /MTU V. C, Summer - Cycle 12 1.50 j
.7...,..
3..
3...,..
6.....
.....s.....
... g....
1.45 1
y 3...,...,...
. 4,....,.
4
.s.....
..s..e........>..s..
....s...>..r........s...,..
.......t 1.40
..r......+.
.. s... u......
...s...,..
..>..t..
..>..s......
..,.....,. +.
3...,...
,..s..
1.35
...s..
..r........
v t.. r.......
..:..t...
..t..
1.30
. +.........
.. P......
u
- 1.25 3:
....,....,..,......t.,....
,.....s...,...,.....,..;...,..
s................
6..
..... +.....
1.20
..r.....
.. s... e.....
.. >.. s.. u..
..u..........,..
........... o........
+
.* k......
1.15
...u..........s...r......
.s......t........>..s...
.+.......i'.
F_..-.
7+
p
...,..s..,.
1.10 a
,....s..,....,..
,..s..
...r...
..t..r......
....t....
..t..
1.05 1.%
0 2
4 6
8 10 12 j
Bottom Core Height (Feet)
Top
)
12 Revision 2
i V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 2. RAOC W(z) at 800 MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.4299 6.08 1.1266 0.16 1.4295 6.24 1.1292 0.32 1.436J 6.40 1.1313 0.48 1.4500 6.56 1.1326 0.64 1.4611 6.72 1.1333 0.80 1.4584 6.88 1.1336 0.96 1.4490 7.04 1.1337 1.12 1.4379 7.20 1.1337 1.28 1.4240 7.36 1.1339 1.44 1.4080 7.52 1.1344 1.60 1.3905 7.68 1.1347 1.76 1.3714 7.84 1.1340 1.92 1.3507 8.00 1.1326 2.08 1.3296 8.16 1.1308 2.24 1.3084 8.32 1.1282 2.40 1.286 8.48 1.1242 2.56 1.2643 8.64 1.1191 2.72 1.2424 8.80 1.1148 2.88 1.2238 8.96 1.1155 3.04 1.2099 9.12 1.1173 3.20 1.2000 9.28 1.1199 3.36_ _
1.1937 9.44 1.1226 3.52 1.1888 9.60 1.1234 3.68 1.1839 9.76 1.1218
)
3.84 1.1783 9.92 1.1216 4.00 1.1719 10.08 1.1247 4.16 1.1650 10.24 1.1310 4.32 1.1591 10.40 1.1365 j
4.48 1.1557 10.56 1.1399 4.64 1.1532 10.72 1.1415 4.80 1.1503 10.88 1.1423 4.96 1.1466 11.04 1.1436 5.12 1.1427 11.20 1.1444 5.28 1.1387 11.36 1.1422 5.44 1.1338 11.52 1.1292 5.60 1.1280 11.68 1.1129 5.76 1.1233 11.84 1.0997 5.92 1.1240 12.00 1.0876 13 Revision 2
I V. C. Summcr Cycle 12 COLR, Revision 2 August 1999 j
i Figure 7. RAOC W(z) at 6000 MWD /MTU V. C. Summer - Cycle 12 1.50
...c.
\\
..s.....
..s.......
..>..s..,...
..s...
1.45 3
7..
..s.....
..s..........
..s...>..s........s...,............s...
..>..s..
1.40
..r.....
..s..r.....
..>..s....
..>..>..s..........>......
,......s....
,..s..
1.35
. b..
......... s... r.......
......s.......
..:..:..r....:..:..t..
+.
1.30
...r
....... +
o n
..s.....
....s......
..u.
.s...
..s..
.....s................ >..
u 1.25
......,...,. +.........,...
. 4.g......s...s.....
.s...>..s.......s..+,............s...
.....s..
J.
.+.
1.20,,
+
+
..s......+.
..>..s..u....>..>..s
......s...>..
..s...u.....
.........+.
1.15 6
..s.....
.. s... t....
..>..s..s.
9.>...
.s..
. +.........
.s.........
. +.........
.+,..,.....
- p.,..,....
1.10
........s..
c.....
c.......,....,..
..r...
..t...
..:..t..r.
...:..t......
1.05 j
..s.....
..s.......
..s..
......s.....
1.00 0
2 4
6 8
10 12 Bottom Core Height (Feet)
Top t
14 Revision 2
' V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 3. RAOC W(z) at 6000 MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.1996 6.08 1.1134 0.16 1.1991 6.24 1.1228 0.32 1.2050 6.40 1.1312 0.48 1.2169 6.56 1.1389 0.64 1.2270 6.72 1.1461 0.80 1.2262 6.88 1.1527 0.96 1.2203 7.04 1.1582 1.12 1.2134 7.20 1.1630 1.28 1.2047 7.36 1.1678 1.44 1.1946 7.52 1.1729 1.60 1.1834 7.68 1.1778 1.76 1.1707 7.84 1.1818 1.92 1.1569 8.00 1.1850 2.08 1.1439 8.16 1.1878 2.24 1.1327 8.32 1.1898 2.40 1.1227 8.48 1.1897 2.56 1.1133 8.64 1.1895 2.72 1.1038 8.80 1.1892 2.88 1.0939 8.96 1.1959 3.04 1.0844 9.12 1.2080 3.20 1.0780 9.28 1.2202 3.36 1.0781 9.44 1.2306 3.52 1.0780 9.60 1.2390 3.68 1.0777 9.76 1.2458 3.84 1.0773 9.92 1.2535 4.00 1.0767 10.08 1.2647 4.16 1.0757 10.24 1.2778 4.32 1.0751 10.40 1.2897 4.48 1.0757 10.56 1.2994 4.64 1.0764 10.72 1.3078 4.80 1.0778 10.88 1.3149 4.96 1.0799 11.04 1.3202 5.12 1.0817 11.20 1.3245 5.28 1.0831 11.36 1.3245 5.44 1.0853 11.52 1.3142 5.60 1.0894 11.68 1.3000 5.76 1.0956 11.84 1.2874 5.92 1.1038 12.00 1.2750 l
15 Revision 2
l V. C. Summer Cycle 12 COLR. Revision 2 August 1999 '
Figure 8. RAOC W(z) at 10000 MWD /MTU V. C. Summer - Cycle 12 1.50
,..c.
..s.....
..s..u.....
..>..s..
...,..>..s..
......s.............s...
..s.....
.. s.. u........>..s..u....>..>..s..
.....s...>..........s...
1.40
..v.....s...
..s..u.....
..>..s..e.
..>..>..s........s...>..
3...,.....
..3...,......
1.35
..t...
..>..t...
...:..t..
1.30
..s..,....,..
c..
......s...>..,. +........,,...
..s..
..,..s..u...
..s..
u
- 1.25 4
.........,. +
...3
..............o
+
..s..........s...r........>..s...
....s...>..s.........s.>...........s...
.,4 s
1.20
.+
...s.....+..
..s..r.....
..>..s..u..
.s.......s...>.........s...
.......... +.
. +.
.......... +.
1.15
. 4,..s...'...'.....>..s'...'...
.s.'...>..'s..
'... '.. > '.....'...'..s...
+,.......
. y...,....
3...,...,......,....
1.10 q
. 9...
... +.......
... +.,...
..t...
....t...
.... a... t......
......s...
1.05 c.
..s.....
..s..s......
..s..
.s...
..s........s.....
1.00 O
2 4
6 8
10 12 Bottom Core Height (Feet)
Top 16 Revision 2
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 4. RAOC W(z) at 10(MN) MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.1857 6.08 1.1299 0.16 1.1849 6.24 1.1397 0.32 1.1908 6.40 1.1490 0.48 1.2031 6.56 1.1577 0.64 1.2138 6.72 1.1656 0.80 1.2131 6.88 1.1726 0.96 1.2075 7.04 1.1788 1.12 1.2010 7.20 1.1844 1.28 1.1929 7.36 1.1900 1.44 1.1832 7.52 1.1959 1.60 1.1723 7.68 1.2014 1.76 1.1601 7.84 1.2057 1.92 1.1471 8.00 1.2090 2.08 1.1337 8.16 1.2112 2.24 1.1205 8.32 1.2126
~.40 1.1073 8.48 1.2130 2.56 1.0939 8.64 1.2125 2.72 1.0811 8.80 1.2116 2.88 1.0702 8.96 1.2117 3.04 1.0622 9.12 1.2120 3.20 1.0579 9.28 1.2140 3.36 1.0589 9.44 1.2199 3.52 1.0600 9.60 1.2277 3.68 1.0623 9.76 1.2365 3.84 1.0652 9.92 1.2457 4.00 1.0682 10.08 1.2544 4.16 1.0711 10.24 1.2624 4.32 1.0740 10.40 1.2694 4.48 1.0767 10.56 1.2753 4.64 1.0793 10.72 1.2800 4.80 1.0820 10.88 1.2833 4.96 1.0844 11.04 1.2853 j
5.12 1.0856 11.20 1.2868 5.28 1.0861 11.36 1.2842 5.44 1.0890 11.52 1.2711 5.60 1.0971 11.68 1.2547 5.76 1.1082 11.84 1.2407 5.92 1.1194 12.00 1.2273 l,
l 17 Revision 2
i i
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figuw 9. RAOC W(z) at 20000 MWD /MTU V. C. Summer - Cycle 12 1.50
.s...>..s.
......s...,..
..,..s.....
..>..s..s..
1.45 3...,
3..
..>..s..
....s...>..s..
...s...>.........s...
i
..r.....
.....s...e.....
1.
.....s.........-..>..s...
..s...>..t.......>..s..........s...
..s.....
1.35
..r...
1...
......s............:..
1.30
..s.....
..s.......
..s..
u
. mi
- 1*25
^
- q......,...,....p..
9,..
,.. +
D...
..................t.
..s.,.>..,,
..s.....
.....s...r.....
..>..s..
>..s..
4.
.....,... +.
....g p
.........e...........
..s..u........>..s..+...s...>..s........s...
........s...
.4.....
....... 44..
........ +.
4 g.,...
1.15
..s+
.s.......s...>..s...
...r...........
..s......
g 4......
...,......,... +,....,...... o..,....,...
1.10
..+......s..........
..+...6............
... +,,,
,.. g.,...
..:..t...
...:..t..
..t...
1.............:..
1.05
..s.....
..u..
..>.....s..
..s.........
.......s...
1.M 0
2 4
6 8
10 12 Bottom Core Height (Feet)
Top 18 Revision 2
r
~
- V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 5. RAOC W(z) at 20000 MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.1601 6.08 1.2038 0.16 1.1577 6.24 1.2147 0.32 1.1637 6.40 1.2240 f
0.48 1.1777 6.56 1.2319 0.64 1.1912 6.72 1.2386 0.80 1.1916 6.88 1.2440 0.96 1.1865 7.04 1.2481 1.12 1.1815 7.20 1.2507 1.28 1.1752 7.36 1.2519 1.44 1.1672 7.52 1.2516 1.60 1.1577 7.68 1.2500 1.76 1.1470 7.84 1.2470 1.92 1.1356 8.00 1.2425 2.08 1.1236 8.16 1.2359 2.24 1.1113 8.32 1.2281 2.40 1.0998 8.48 1.2210 2.56 1.0904 8.64 1.2155 2.72 1.0825 8.80 1.2085 2.88 1.0746 8.96 1.1973 3.04 1.0676 9.12 1.1872 3.20 1.0655 9.28 1.1870 3.36 1.0716 9.44 1.1972 3.52 1.0819 9.60 1.2096 3.68 1.0921 9.76 1.2192 3.84 1.1013 9.92 1.2272 4.00 1.1101 10.08 1.2353 4.16 1.1187 10.24 1.2434 4.32 1.1270 10.40 1.2506 4.48 1.1345 10.56 1.2563 4.64 1.1415 10.72 1.2605 4.80 1.1479 10.88 1.2632 4.96 1.1534 11.04 1.2645 5.12 1.1575 11.20 1.2657 5.28 1.1604 11.36 1.2624 5.44 1.1643 11.52 1.2468 5.60 1.1714 11.68 1.2283 1
5.76 1.1809 11.84 1.2136 5.92 1.1921 12.00 1.1999 19 Revision 2
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 10. Baseload W(z) at 150 MWD /MTU V. C. Summer - Cycle 12 1.20
..,...........s..........
.. s... t.....
....>..t..........>..
.......s...
3...,...,........,....
...,.......s..
1.15
- 3... t.....
...>..t.........:..>..
..s......
..s...
e
- 1.10 <
u W
..t...
+...
..>..t...
..>..t..
.+
..,....,.. 4 o
.+'
1.05
., +.
.......s....
..:..t...
...>..t......
l j
........u.
.s..
)
........s...
j s
a r
0 2
4 6
8 10 12 Bottom Core Height (Feet)
Top 1
1 1
I
'O Revision 2
~
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 6. Baseload W(z) at 150 MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) j 0.00 1.1024 6.08 1.0615 0.16 1.1033 6.24 1.0601 0.32 1.1043 6.40 1.0585 O.48 1.1057 6.56 1.0568 9.64 1.1070 6.72 1.0549 0.80 1.1074 6.88 1.0529 O.96 1.1074 7.04 1.0506 1.12 1.1072 7.20 1.0486 1.28 1.1068 7.36 1.0483 1.44 1.106J 7.52 1.0503 1.60 1.1058 7.68 1.0532 1.76 1.1050' 7.84 1.0556 1
1.92 1.1041 8.00 1.0576 2.08 1.1030 8.16 1.0596 2.24 1.1018 8.32 1.0617 2.40 1.1004 8.48 1.0637 1
2.56 1.0989 8.64 1.0656 2.72 1.0973 8.80 1.0674 2.88 1.0955 8.96 1.0691 3.04 1.0936 9.12 1.0708 3.20 1.0916 9.28 1.0725 3.36 1.0894 9.44 1.0740 3.52 1.0873 9.60 1.0755 3.68 1.0856 9.76 1.0769 3.84 1.0842 9.92 1.0782 4.00 1.0830 10.08 1.0794 4.16 1.0818 10.24 1.0806 4.32 1.0806 10.40 1.0816 4.48 1.0792 10.56 1.0826 4.64 1.0778 10.72 1.0834 4.80 1.0762 10.88 1.0842 4.96 1.0746 11.04 1.0850 5.12 1.0729 11.20 1.0856 5.28 1.0710 11.36 1.0861 5.44 1.0690 11.52 1.0861 5.60 1.0668 11.68 1.0859 5.76 1.0646 11.84 1.0860 5.92 1.0629 12.00 1.0862 21 Revision 2
^
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 11. Baseload W(z) at 3400 MWD /MTU V. C. Summer - Cycle 12 1.20
... s... t..
...... s... s.........
............s.........
..>..s...
........... 3..
3...,..
1.15
...>..t.........s...>............s...
..s......
...... s... s.....
+,.
n
- 1*10
. ' +.
- :r-J 3
. s... s.......>..>..t..
...... s... s.
..r...
..n......
l
. +9. +t,.....
1.05
...>..t......... s... s.........
..n......
..>..t...
3..
1.00
~
0 2
4 6
8 10 12 Bottom Core Height (Feet)
Top
.4 Revision 2
l
~
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 7. Baseload W(z) at 3400 MWD /MTU
{
V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.1117 6.08 1.0700 0.16 1.1126 6.24 1.0684 0.32 1.1135 6.40 1.0667 0.48 1.1150 6.56 1.0645 0.64 1.1162 6.72 1.0619 0.80 1.1166 6.88 1.0595 0.96 1.1167 7.04 1.0586 1.12 1.1166 7.20 1.0591 1.28 1.1164 7.36 1.0607 1.44 1.1160 7.52 1.0629 1.60 1.1155 7.68 1.0653 1.76 1.1147 7.84 1.0675 1.92 1.1138 8.00 1.0696 2.08 1.1128 8.16 1.0716 2.24 1.1115 8.32 1.0736 2.40 1.1101 8.48 1.0755 2.56 1.1085 8.64 1.0773 2.72 1.1067 8.80 1.0791 2.88 1.1048 8.96 1.0808 3.04 1.1027 9.12 1.0824 3.20 1.1005 9.28 1.0839 3.36 1.0980 9.44 1.0854 3.52 1.0955 9.60 1.0868 3.68 1.0935 9.76 1.0881 3.84 1.0919 9.92 1.0894 4.00 1.0904 10.08 1.0906 4.16 1.0891 10.24 1.0918 4.32 1.0877 10.40 1.0928 4.48 1.0861 10.56 1.0938 4.64 1.0844 10.72 1.0948 4.80 1.0829 10.88 1.0957 4.96 1.0814 11.04 1.0965 5.12 1.0799 11.20 1.0972 5.28 1.0784 11.36 1.0978 5.44 1.0768 11.52 1.0978 5.60 1.0751 11.68 1.0977 5.76 1.0733 11.84 1.0979 5.92 1.0716 12.00 1.0982 23 Revision 2
V. C. Summcr Cycle 12 COLR, Revision 2 August 1999 Figure 12. Baseload W(z) at 6000 MWD /MTU V. C. Summer - Cycle 12 1.20
..t.......
..>..t...
...>..t...
.........s.............>..
..,....,.........3...,...
q 1.15
..... a... t......
..t...
..>..t...
......s...
p u
1.10,
..t...+.....
- 3... t.......... a... t........s...>.........
.....,... +g 3..,....
....,...,. o...
,. ^.
. ^.
1.05
+e. >
..t...
..t...
- 3... t.......... a... t......
...... s...
3...,.....
1.00 O
2 4
6 8
10 12 Bottom Core Height (Feet)
Top 24 Revision 2 u
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 8. Baseload W(z) at 6000 MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.1014 6.08 1.0599 0.16 1.1023 6.24 1.0581 0.32 1.1033 6.40 1.0562 0.48 1.1046 6.56 1.0538 0.64 1.1058 6.72 1.0506 0.80 1.1063 6.88 1.0480 0.96 1.1064 7.04 1.0481 1.12 1.1064 7.20 1.0507 1.28 1.1063 7.36 1.0538 1.44 1.1060 7.52 1.0561 1.60 1.1055 7.68 1.0581 1.76 1.1048 7.84 1.0601 1.92 1.1039 8.00 1.0622 2.08 1.1029 8.16 1.0642 2.24 1.1016 8.32 1.0660 2.40 1.1001 8.48 1.0678 2.56 1.0985 8.64 1.0696 2.72 1.0967 8.80 1.0712 2.88 1.0947 8.96 1.0728 3.04 1.0925 9.12 1.0744 3.20 1.0901 9.28 1.0758 3.36 1.0874 9.44 1.0772 3.52 1.0847 9.60 1.0786 3.68 1.0825 9.76 1.0799 3.84 1.0806 9.92 1.0811 4.00 1.0790 10.08 1.0823 4.16 1.0776 10.24 1.0834 4
4.32 1.0760 10.40 1.0844 4.48 1.0743 10.56 1.0855 4.64 1.0725 10.72 1.0865 4.80 1.0710 10.88 1.0874
{
4.96 1.0696 11.04 1.0882 5.12 1.0684 11.20 1.0891 5.28 1.0672 11.36 1.0897 5.44 1.0659 11.52 1.0898 5.60 1.0646 11.68 1.0897 J
5.76 1.0632 11.84 1.0899 5.92 1.0616 12.00 1.0903 25 Revision 2 L.
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 13. Baseload W(z) at 10000 MWD /MTU V. C. Summer - Cycle 12 1.20
..t...
..s......
..,..s...
..a...t..
.........s................
..u..
1.15
......... s... r.....
.. s... s.....
...>..t..
..r...
.. ~........
...,..,++
w 1.10
., +.
+
....t...........s...+.......>..s....
..>..s..
........s..........
4,.
j
>, +..,.w ++.
1.05
..t...
..s..u...
.. s... s.........>.....
.........s...
.........s...
.......s...
1.00 2-O 2
4 6
8 10 12 Bottom Core Height (Feet)
Top 26 Revision 2
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Table 9. Baseload W(z) at 10000 MWD /MTU V. C. Summer - Cycle 12
)
l Core Height Core Height (ft)
W(z)
(ft)
W(z) 0.00 1.1124 6.08 1.0577 0.16 1.1133 6.24 1.0558 0.32 1.1142 6.40 1.0537 0.48 1.1154 6.56 1.0523 0.64 1.1165 6.72 1.0528 0.80 1.1168 6.88 1.0547 0.96 1.1166 7.04 1.0570 1.12 1.1163 7.20 1.0594 1.28 1.1158 7.36 1.0616 1.44 1.1150 7.52 1.0637 1.60 1.1140 7.68 1.0657 1.76 1.1127 7.84 1.0675 1.92 1.1110 8.00 1.0693 2.08 1.1092 8.16 1.0709 2.24 1.1070 8.32 1.0725 2.40 1.1047 8.48 1.0740 2.56 1.1021 8.64 1.0753 2.72 1.0992 8.80 1.0766 2.88 1.0962 8.96 1.0778 3.04 1.0930 9.12 1.0789 3.20 1.0894 9.28 1.0799 3.36 1.0856 9.44 1.0809 3.52 1.0821 9.60 1.0818 3.68 1.0798 9.76 1.0827 3.84 1.0784 9.92 1.0835 4.00 1.0771 10.08 1.0843 4.16 1.0755 10.24 1.0850 4.32 1.0738 10.40 1.0858 4.48 1.0722 10.56 1.0865 4.64 1.0704 10.72 1.0873 4.80 1.0685 10.88 1.0879 4.96 1.0665 11.04 1.0886 5.12 1.0647 11.20 1.0892 5.28 1.0634 11.36 1.0898 5.44 1.0623 11.52 1.0898 5.60 1.0612 11.68 1.0897 5.76 1.0601 11.84 1.0898 5.92 1.0590 12.00 1.0902 27 Revision 2
1 I
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 14. Baseload W(z) at 20000 MWD /MTU V. C. Summer - Cycle 12 j
1.20
..e..............s..........
- 2... s........s...>..t.......... s.. 1...
4 1
J 1 15 e"
. +.
....s..........
.. s... s.......... s... t...
...... s... s............:..
.+
...e.......
. +.........
.......s...
4
{
+
i 3...,..
> +,
.+.
w
-4 u
N
+.
+
..s..+...
..,..s...
....>..t..
.........s...
....4...
. +.
.++
. o.
+...........+
4 4
r..
- 2... t.........
2...t....
..s......
1...
.......s....
..w..
4 0
2 4
6 8
10 12 Bottom Core Height (Feet)
Top 28 l
Revision 2
l V. C. Summer Cycle 12 COLR, Revision 2 August 1999 l
Table 10. Baseload W(z) at 20000 MWD /MTU V. C. Summer - Cycle 12 Core Height Core Height (ft)
W(z)
(ft)
W(z)
=
0.00 1.1476 6.08 1.0625 0.16 1.1481 6.24 1.0653 0.32 1.1486 6.40 1.0679 O.48 1.1495 6.56 1.0703 0.64 1.1499 6.72 1.0724 0.80 1.1491 6.88 1.0743
]
0.96 1.1478 7.04 1.0760 1.12 1.1462 7.20 1.0774 1.28 1.1441 7.36 1.0786 1.44 1.1415 7.52 1.0796 1.60 1.1385 7.68 1.0805 1.76 1.1349 7.84 1.0811 1.92 1.1308 8.00 1.0816 2.08 1.1263 8.16 1.0819 2.24 1.1213 8.32 1.0822 2.40 1.1161 8.48 1.0820 2.56 1.1106 8.64 1.0819 2.72 1.1047 8.80 1.0818 2.88 1.0981 8.96 1.0830 3.04 1.0911 9.12 1.0855 3.20 1.0853 9.28 1.0888 3.36 1.0819 9.44 1.0925 j
3.52 1.0798 9.60 1.0962 3.68 1.0778 9.76 1.0995 3.84 1.0754 9.92 1.1026 4.00 1.0730 10.08 1.1054 4.16 1.0706 10.24 1.1079 4.32 1.0680 10.40 1.1100 4.48 1.0651 10.56 1.1117 4.64 1.0625 10.72 1.1131 4.80 1.0610 10.88 1.1141 4.96 1.0605 11.04 1.1148 5.12 1.0604 11.20 1.1153 5.28 1.0603 11.36 1.1153 5.44 1.0602 11.52 1.1143 5.60 1.0594 11.68 1.1131 5.76 1.0593 11.84 1.1124 5.92 1.0600 12.00 1.1119 29 Revision 2
~
V. C. Summer Cycle 12 COLR, Revision 2 August 1999 Figure 15. RCS Total Flowrate Versus R for Three Loop Operation V. C. Summer - Cycle 12 28.90
........s.......
..>.......s..>.....s..s........s..........s..>....
28.70
...:...... s..........>.......s..>...... s.. s...:... s..
.......s..>......
l Acceptable Operation Region Unacceptable Operation Region
.....c..,...,......,........,..,...
....,.3....
28.50 2
n.
g jg l
l l
l
- l...
..a...
(1.00.28.36)
.......s..s.......
e l
l l
l l
6.
3 28.30 O
...,..........c..,.
u W
~'O
..z.........
.... s.. s....... s.. s........ s..
.......s..>...
F cn o
E 28.10
......s......
.... s.. s...
...s..>.......s...
......s..s.....
s I
e a
a e
r e
a
.3....,...,..
3..
....... >..........>.......s..>......s..s........s..
.......s......
27.70 O.90 0.95 1.00 1.05 1.10 N
R = F m/1.62[1.0 + 0.3(1.0 - P)]
Measurement Uncertainty of 2.1 % for Flow (includes 0.1% for feedwater venturi fouling) is included in this figure.
30 Revision 2