Text
.,.. _. -.
-.......-....-.;.-.~...-.,
..._~-..w
. 1;3;9 c:y w._w g.
c;q.
. PART.21 IIENTIRCATibi10..
FoNbo -cmo CTPANY IWE YdDM a
IRTE OF LETTER
%a/f o D03ET TE ro 4/ 3 ; o-V/ r l
IRTE DISTRIBUTED Vy/&
ORIGIl%L EPORT[
SUPPLEENTARY
~
DISTRIBUTION:
1.
EACTOR (R) 4 REL CYCLE &
SAEGlRRDS (S)
IEFILES MTERI E @
IE RLES l
AD/RDI (2)
IE R LES-AD/SG AD/RCI (2)
AD/lWSI AD/RDI M.
EGIONS I,II,III,IV,V EGIONS I,II,III,IV,V EGIONS l',II,III,IV,V
~~
.I VENDOR BR. R-IV VENDOR BR. R-I.V VENDOR BR. R-IV
[
LDEB / FPA MB 5715 ES / FOS - SS-396 NRR/ DOL AEOD M B 7602 LOEB / FPA MB 5715 NFSS / SG SS-881 NRR/ DOE AEDD ME 7602 LDEB/FPA PNB 5735 NRR/DSI CENTPAL FILES 016 AE00 FNB7602 cNRR/ DST CENTPAL RLES ( CHRON)
CENTPAL RLES 016 NRR/ DOL PDR CENTPAL FILES (CHRON)
CENTRALFILES 016 LPDR CENTPAL FILES SS-396 CENTRAL FILES (GRON)
LPDR LPDR TEPA TERA ACTION:
PRELIMINARY EVALUATION OF THE ATTACHED REPORT INDICATES LEAD RESPONSIBILIT( FOR FOLLOWUP AS SK)WN BELOW:.
IE ]
NRR[.
NFSS [
OEER Ss FFMSI REV:7/9/80
,8.00807007/.
5
'Jiuclear Valve Division pment ilorg-Witner Corporation 7500 Tyrone Ave.. V:n Nuys. Californb 91409. T;Iephone:213-781-4 @ 0 Mailing Address: P.O. Box 2185. V;n Nuys, California
- TWX 910-495-1726 Q.80 188/WRW 30 M
~D 0
July 22, 1980 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Comission Washington, D.C. 20555
Subject:
Notifiction Under Rules of 10CFR21
Reference:
Notification Report Number 0003 Dear Sir; Enclosed are three (3) copies of referenced notification report, as required by paragraph 21.21(b)(2) of 10CFR21.
The original has been sent to the Director of Region V.
The responsible officer at NVD, Mr.
C.A. Dotter, President and General Manager was notified by interoffice memo on 7/21/80.
If additional information is required do not hesitate to contact the undersigned at your convenience.
Respectfully, BORG WARNER CORPORATION Nuclear Valve Division Wbh j
W.R. Wheaton l
- Director, Quality Assurance (213) 781-4000 Ext. 232/233 i
WRW/jeh cc:
QA Files (3) g 3-
. -.- - -~ ~
v - - - - - -- cr - - e - - - - - -
r
--r--=-
~ - - - -
-y Nuclear Valva Division og se o.wsn.r corporan*a NOTIFICATION REPORT 7500Tyrone Ave Van Nuys Canfernia91409 to Nuclear Regulatory Commission PART NUMBER Various (See Addendum)
N/R No.
0003 PART NAME 6" Gate Vaive CUSTOMERS TVA & Duke Power MANUFACTURER Nuclear' Valve Div.,
PROJECT Hartsville A, Unit 1 & Catawba
~
Bore-Warner Corp.
DATE DEFECT DISCOVERED July 7, 1980 DESCRIPTION OF NONCONFORMANCE, ANALYSIS OF CONDITION, AND CORRECTIVE ACTION (ATTACHSUPPORTINGDATA).
A~ possibility exists that in a " worst case" tolerance buildup condition, the gate. could disengage. from the guide when valve is in the backseat position.
A stem extension bushing has been designed and machined that will interface between the stem and the backseat. When installed, it will prevent any possiblity of disengagement of the gate from the guide.
A modification procedure has been written. Valves will be modified in the field. All new valves will incorporate a changed gate guide location to prevent recurrence.
~
QUANTITY AND LOCATION OF ALL SIMILAR ITEMS DELIVERED WITHIN THE U.S.A. THAT CONTAIN THE SAME NONCONFORMANCE.
~
y-SEE ADDENDUM ATTACHED TO THIS REPCRT.
&txfC
' 7 M-10 Director, Quality Assurance Date i
FORM NO. 400-144
~
I i
,('
ADDENDUM TO NRC NOTIFICATION REPORT NUMBER 0003 PART NO.
QTY.
SERIAL NO.
MARK / ITEM N0.
CUSTOMER PROJECT 401KBB3-002 1
28644
, 44-FF004 T.V.A.
Ilartsville A, Unit 1 P
35751
'E12-F-026A T.V.A.
Ilartsville A Unit I 401KBC4-001 2
35557 20-396 Duke Pwr.
Catawba 35558 401KBC3-001 10 31755 thru 20-393 Duke Pwr.
Catawba 31764
.