Responds to Violations Noted in Insp Rept 50-302/89-20.Maint Dept Begun Utilizing Log Book to Record Written Turnovers & ASV-167 Locked Upon Notification of Incorrect Position
ML19325E699
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 11/01/1989
From: Widell R
FLORIDA POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
3F1188-01, 3F1188-1, NUDOCS 8911080293
Download: ML19325E699 (3)


Text

i t' ,

@ \

=

comeonuiou {

Novenbar 1,1989 3F1188-01 ,

l U. S. Nuclear Regulatory Omanission  !

Attention: Document Contrtl Desk Washington, D. C. 20555

Subject:

Crystal River Unit 3 i Do::ket No. 50-302 Operating License DFR-72 Inspection Raport 89-20 t Dear Sir F

Florida Power corporation (FPC) provides the attached as our i response to the subject inspection r p rt. l Shoald there be any questions, please contact this office.  ;

l Yours very truly, t Rolf,C. Widell Director, Nuclear Operations Site Support L t

l- WIR: mag Att.

xc: Regional Administrator, Region II ,

Senior Besident Inspector l

8911080293 891101 ,

PDR Q

ADOCK 05000302 PDC y[

l' POST OFFICE DOX 219

  • CRYSTAL RIVER, FLORIDA 326290219 + (934) 663 2943 l

A Florida Pmpress Company

j .~ "

IHRIIA IOER 03RKHATIQ4  !

INSPDCTIQ4 REPORP 89-20 REPLY 'IO ICTICE OF VIOIATIQi VIDIATIG4 89-12-Q1 Technical Specification 6.8.1 requires the inplementation of written sucodures for those activities r-h rded in Alpudix "A" of Regulatory Guide 1.33, Navenber 1972. Regulatory Guide 1.33 incitdes operation ard maintenance s uceiures.

Contrary to the above:

1) On August 28, 1989 MP-150, Maintenance of Raw Water Punp, paragraph 4.2.5 requirirg quality control to verify the condition of mating surfaces prior to assembly, was not performed.
2) On September 4, 1989 OP-4 50, Emergency Feedwater Systen, was not prtperly implemented in that valve ASV-167 was fourd not locked in position as required by OF450.

'Ihis is a Severity level IV Violation (Surplement I).

FLORIIA TOER GRTOPATIQi RESPONSE Florida Pwer Corporation (IK) accepts the violation.

APPARDTP CAUSE OF,YlQI.ATICU

1) Failure to cartply with the the procedural requirements of MP-lbo is a cambination of failure to follow sucodure ard procedural inadequacy.

Step 4.2.5 calls for QC to verify the conditicn of all machired matirg surfaces. Failure to list what mating surfaces were intended by "all macitined mating surfaces" did not provide adoquate guidance for the craft performing the work activity nor did it provide adequate placement of QC hold points. 'Ibe Quality control Inspector advisod the maintenance personnel that there were additional inepections to perforn prior to r==dly, but this information was not cxrtrunicated to the next maintenance shift and there were no reminders referrirg workers back to step 4.2.5 in the prvcidure.

2) 'Ibe cause of the violation is attributed to personnel error. On several occasions ASV-167 was unlocked and repositioned to adjust bypass steam ficw. Ib11 cuing one of the adjustmonts, the personnel L irreolved failed to re-1cx.k the valve.

l l

l l

O 00RRITTIVE ACTIW

1) Reameenbly was discontirmed until it was detemined that no safety inpact, due to the missed inspection, was involved.

Ihlrirg the performance of the successive rebuild of RfP-2B, eat assembly step of a machined flarge was marked with an asterisk to i runirx1 the individual that a QC Inspector must insk this surface prior to assembly. Step 4.2.5 was utilized as the f:.nal acceptance of :

all flanges.

i

'Ihe importance of adhering to procedural requirunants was stressed to '

the Mechanical and Rtilding Servloes Supervisors and the craft ,

personnel.

'Ibe maintenanos department has begun utilizing a log book to record written turTovers.

2) ASV-167 was locked upon notification of the incorrect position.

IRTE OF IULL O'MPIJANCE:

1) Tull ocupliance was achieved on August 8,1989 when it was detemined l that the niaM QC hold point had no safety impact and sqpervision was mammwd the flange was cleaned and installed properly. -
2) ASV-167 was locked upon notification by the NRC inspector on Septenbar 4, 1989. '

i ACTICNS TAKD4 'IO TREVENT REOJRRWCE

1) MP-150 will be revised to list machined surfaces to be checked and QC hold points will be placed appropriately. Other mechanical .

maintenance procedures will be reviewed for similiar revisions. ,

2) 'Ihis incident will be reviewed by all on-shift Operations personnel.

In addition, ASV-167 will be labeled to indicate that it should be locked in a throttled position.