LER 80-014/03L-0:on 800608,while Performing ST 6.9,valve Mo 3-10-26B Failed to Close After Stroked Open.Caused by Mechanical Problem in Valve.Mo 3-10-26B to Be Disassembled & Repaired
ML19320D446
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 07/14/1980
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
3-80-14-3L, LER-80-014-03L, LER-80-14-3L, NUDOCS 8007210378
Download: ML19320D446 (1)


Text

--

.__ ~__m.--.. , _ . , _ , . _ , -

Mr. Boyca H. Gri:r, Director No. 3 1h/3L Offica cf. Inspection & Enforcement, Region I

~ U,$. Nuc14ar Regulttory Commission 631 Park Avenuo King of Prussia, PA' 19406

. Dear Mr. Griers This LER concerns the failure of the "B" RHR containment spray outboard isolation valve (M0-26B) to close during Surveillance Testing.

Governing Tech Spoo is 3 7.D.1.

u.s[ NUCLEAR REGULATORY coastelS$8oN LICENSEE EVENT REPORT t*LEAsa rRsNT oR TYPs 4LL REcuaREo NeoRas4TioNs coNTRotaLocicl l l 1 I l .l@ s n i a6 9 lP l A l P l 8 lS 13 .lQo lo l loL80k8sht LaLLpenti 4.smsg 1 Bb l0 l0seuMetH lo lo l 10 lo#bl @ 413 at 11 TYPE LAG &s.66 11Jie13 hel@l_l LAT te lg fA AN* 4 a ' l'$ @l01510 l 10121718 l@l 01610181810 l@l017 l1 I h I 810 l@

EVENT oEsGRIPTioN AND PRouAu cNE ENCEb

[

lo I/I I While performina ST 6.9 (RHR "B" pump, valve, flow, and unit cooler functional) with the Unit at 100% power, valve MD 3-10-26B l Lo g I l

1n i4 I I failed to close after beine stroked seen. This valve is the "B" RHR containment spray and i

,M i outboaQiaolation valve for the I

17 50 i therefore is an inoterable isolation valve ner Tech Snee 1.7.D.1.

l lillB I The consecuences are minimal since the redundant isolation valve MO 3-10-31B is being maintained in the closed rosition.

= = = -- .=. ,=.

8, I s IB l@ LEj@ [B_l@ lV l A l L IV lE lX lh [E_j@ [D,J @

. . .. n u o .. i. 2.

Revision SEouE NTIAL OCCUR 81ENCE REPoHT

.' CoOE TvPE M EV18tf vf AR REPORT 40.

@ l('=gg,'no I810I l--J l 01 il hla Ld 10Ial ao LLJ ao I-1 as 10J sa

_a a n a. ao am PL T T #40URS sue F M 6u.. 99L FAC RER AK N AY Q.,W@ a. . [ Zj@ W@ l010l010l

.v. .s .. ,

L..N_j @ u

[Y_j@ (Nj@ lW1013lol@

CAuSE DEsCitiPTSON ANDcoltHECTIVE AC14GN5 h Cause appears to be mechanical problem in the valve. Per Tech eo l in I

[7 TTl I h.7.D.2, m' $.3(inoperable isolation valve position daily log) was 1 begun to verify that NO 3-10-31B is maintained closed. NO 3-10-26B l yI g] will be disassembled and repa 1 during the next outage of l sufficient duration, and a follow-up report issued. I EI a e s S 'nPoWER OTieER ETATUS onsco R DESCoVERv DEsCR6PTIoM ST l [)_j h Surveillance Testing l

. (Lill lsj@ Lal 0101@l N/A

",2T viTv CSTa=T " "

attaAsso os Rua Asa LoCAnow or RetEAss @

AuounTos N/A ACnviTy @l l N/A I

{.l.311 ( 13 @ [.1]

@l ** **

" ' esaso.=R=e6amaos' Ass

[.f jil l 0 l 0 l 0 I@[,Z,,j@lo.icm,Tio,,9' A

.u Tv,.

l

  • N "

einso d'i.uu'4 s -

huus R cacRieTio=@ l L' L;.1 101010 l@l N/A ee ae n u 1oF.5 of ost oAMAGE TO 9 ACaLITV '

svet ata; seep pigps I

- 6, .vW@l ..

N/A NRC uSE oNW so mu

> u @Es'cR.,Tw.,=

l @ N/A h/ [ , I l l I I I I I I I I l l I.. *t

< yJ. Cooney n y ..

Ud W-9M

  • NAME oP PREPARER psong. {

80072103'& $

._ , ___