MONTHYEARML22181B0842022-06-30030 June 2022 2021 Point Beach Nuclear Plant End-of-Cycle Meeting Handout ML21336A7972021-12-0909 December 2021 GL 2004-02 Resolution Update - NextEra Energy Point Beach, LLC - December 9, 2021 (Slides) ML21335A0232021-12-0808 December 2021 Slides - Point Beach Nuclear Plant, Unit Nos. 1 and 2 December 8, 2021 Public Meeting Slides for the Draft Plant-Specific Supplement 23, Second Renewal Dseis Public Meeting ML21285A1212021-08-0505 August 2021 SLRA Public Meeting Discussion Questions August 5 2021 ML21162A2632021-06-11011 June 2021 2020 Point Beach Nuclear Plant End-of-Cycle Meeting Presentation ML21134A0232021-05-18018 May 2021 GL 2004-02 Resolution Update - NextEra Energy Point Beach, LLC (NextEra) ML21042B9452021-02-17017 February 2021 Scoping and Process Meeting - February 17, 2021 ML20240A2702020-08-27027 August 2020 2019 EOC Slide Presentation ML18213A3912018-07-12012 July 2018 Public Meeting ML18179A4032018-06-29029 June 2018 Public Meeting Discussion Points ML18108A0152018-05-0101 May 2018 NextEra Approach to Resolution of Tornado Missile Protection May 1, 2018 ML18121A3392018-05-0101 May 2018 Slides for Point Beach 2017 EOC Open House ML17023A0652017-01-24024 January 2017 Pre-Submittal Call Regarding License Amendment Requests for Prairie Island Nuclear Generating Plant, Units 1 and 2 and Monticello Nuclear Generating Plant Emergency Action Level Scheme Changes ML16291A1772016-10-18018 October 2016 License Amendment Request Pre-Submittal Discussion October 18, 2016 ML16154A6772016-05-25025 May 2016 Annual Assessment Meeting/Open House (Hand Out) ML15112A0672015-04-20020 April 2015 Annual Assessment Meeting Open House - Handout EOC 2014 Mtg ML15091A5172015-04-0606 April 2015 4/6/2015, Meeting Slide for Public Teleconference on Point Beach MCR Abandonment Analysis for Loss of Control Scenarios ML14112A4252014-04-0808 April 2014 Annual Assessment Meeting, 2013 Reactor Oversight Process - Slides ML13162A7902013-06-11011 June 2013 Meeting Slides ML12206A3252012-08-0707 August 2012 G20120513/EDATS: OEDO-2012-0436 - Briefing Book for Meeting with Duke Energy on August 7, 2012 ML1114603332011-05-25025 May 2011 EOC Licensee Presentation Slides ML1107703492011-03-22022 March 2011 3/22/11 PRE-Application Meeting Slides Regarding NFPA 805 License Amendment Request ML1108206992011-03-22022 March 2011 3/22/11 Revised Pre-application Meeting Slides Regarding NFPA 805 License Amendment Request ML1011304452010-04-22022 April 2010 FPL Energy Point Beach Handout from End-Of-Cycle Public Meeting ML0921107842009-07-29029 July 2009 Meeting Slides, Public Meeting with NRC Region III on Point Beach ML0912007212009-04-29029 April 2009 NRC Presentation Handouts for Point Beach 2008 End-of-Cycle Public Meeting ML0912007042009-04-29029 April 2009 Presentation at 2008 End-of-Cycle Public Meeting ML0912007342009-04-29029 April 2009 NRC Slides for Point Beach 2008 End-of-Cycle Public Meeting ML0828905272008-10-14014 October 2008 Meeting with NRC on AST ML0822503302008-10-0606 October 2008 Teleconference Summary Regarding Point Beach Nuclear Plant Supplement to the Auxiliary Feedeater Amendment ML0826819412008-09-24024 September 2008 Meeting Slides, FPL Energy Point Beach Public Meeting with NRC Region III ML0825401402008-09-16016 September 2008 Meeting Slides Point Beach Nuclear Plant Meeting with NRC on Epu. ML0819905262008-07-16016 July 2008 EOC Annual Assessment Meeting Slides ML0705106742007-02-21021 February 2007 NMC Slides for Public Meeting, Conduct of Operations Action Plan Update. ML0632601422006-11-21021 November 2006 11/21/2006 Informational Meeting Regarding Prairie Island License Renewal Application ML0604406422006-02-10010 February 2006 Summary of Public Meeting to Discuss Point Beach Self-Assessments, Summary Letter & Licensee Slides ML0434900602004-11-30030 November 2004 NMC Slides for 11/30/04 Public Meeting ML0413803782004-05-0707 May 2004 NMC New Fuel Supplier Development Initiative ML0412602942004-04-21021 April 2004 Public Meeting Slides, Point Beach 2003 End-of-Cycle Assessment ML0511502282004-04-19019 April 2004 Public Meeting Slides Point Beach EOC Performance Assessment ML0336406072004-01-0505 January 2004 Summary of Meeting with Nuclear Management Company, LLC Potential Repairs That May Overlap Remnant j-groove Welds on the Upper Reactor Vessel Head Penetrations ML0316902142003-06-16016 June 2003 Enclosure 1- NMC Handout Regulatory Conference Concerning Auxiliary Feedwater Orifice Issue for 06/06/2003 Point Beach Regulatory Conference ML0316903022003-06-16016 June 2003 Enclosure 3b - NMC Handout Regu;Atory Conference Concerning Auxiliary Feedwater Orifice Issue for 06/06/2003 Point Beach Regulatory Conference NRC 2003-0056, Submittal of the Auxiliary Feedwater Orifice Issue Regulatory Conference Slide Presentation2003-06-10010 June 2003 Submittal of the Auxiliary Feedwater Orifice Issue Regulatory Conference Slide Presentation ML1122206032003-06-0606 June 2003 Meeting Presentation, Point Beach, Regulatory Conference, EA-03-057 ML0312202182003-04-25025 April 2003 Public Meeting, Point Beach Re EOC, Licensee'S Slides ML0309300732003-04-25025 April 2003 Public Meeting, Point Beach Re EOC, Slides ML0306407162003-02-0606 February 2003 Meeting Slides Regarding Selective Implementation of the AST for the Point Beach Fuel Handling Accident ML0226102762002-09-17017 September 2002 Meeting Handout Materials for Meeting Re Reactor Vessel Evaluation Methodologies for Point Beach, Units 1 & 2 ML0308706512002-04-29029 April 2002 NMC Viewgraphs - Point Beach Nuclear Plant Potential Common Mode Failure Auxiliary Feedwater 2022-06-30
[Table view] Category:Slides and Viewgraphs
MONTHYEARML22181B0842022-06-30030 June 2022 2021 Point Beach Nuclear Plant End-of-Cycle Meeting Handout ML21336A7972021-12-0909 December 2021 GL 2004-02 Resolution Update - NextEra Energy Point Beach, LLC - December 9, 2021 (Slides) ML21335A0232021-12-0808 December 2021 Slides - Point Beach Nuclear Plant, Unit Nos. 1 and 2 December 8, 2021 Public Meeting Slides for the Draft Plant-Specific Supplement 23, Second Renewal Dseis Public Meeting ML21253A0152021-09-16016 September 2021 Pre-Submittal Meeting: LAR to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times -RITSTF Initiative 4b ML21162A2632021-06-11011 June 2021 2020 Point Beach Nuclear Plant End-of-Cycle Meeting Presentation ML21134A0232021-05-18018 May 2021 GL 2004-02 Resolution Update - NextEra Energy Point Beach, LLC (NextEra) ML21042B9452021-02-17017 February 2021 Scoping and Process Meeting - February 17, 2021 ML20240A2702020-08-27027 August 2020 2019 EOC Slide Presentation ML18121A3392018-05-0101 May 2018 Slides for Point Beach 2017 EOC Open House ML18108A0152018-05-0101 May 2018 NextEra Approach to Resolution of Tornado Missile Protection May 1, 2018 ML17310B2322017-11-0707 November 2017 Presentation Slides - NextEra Energy/Fpl - GSI-191 Issue Resolution, Pre-submittal Meeting, September 20, 2017 ML17205A0192017-07-17017 July 2017 Presentation for Point Beach 2016 EOC Open House ML17023A0652017-01-24024 January 2017 Pre-Submittal Call Regarding License Amendment Requests for Prairie Island Nuclear Generating Plant, Units 1 and 2 and Monticello Nuclear Generating Plant Emergency Action Level Scheme Changes ML16291A1772016-10-18018 October 2016 License Amendment Request Pre-Submittal Discussion October 18, 2016 ML15203A5072015-07-28028 July 2015 July 28, 2015, Turbine Driven Auxiliary Feedwater Cross-tie License Amendment Request ML15203A4982015-07-22022 July 2015 July 2015, Containment Dome Truss Seismic Analysis Methodology License Amendment Request ML15112A0672015-04-20020 April 2015 Annual Assessment Meeting Open House - Handout EOC 2014 Mtg ML15091A5172015-04-0606 April 2015 4/6/2015, Meeting Slide for Public Teleconference on Point Beach MCR Abandonment Analysis for Loss of Control Scenarios ML14112A4252014-04-0808 April 2014 Annual Assessment Meeting, 2013 Reactor Oversight Process - Slides ML13200A3962013-07-19019 July 2013 EA-13-125, Point Beach, Conference Slides ML13162A7902013-06-11011 June 2013 Meeting Slides ML1114603332011-05-25025 May 2011 EOC Licensee Presentation Slides ML1115400612011-05-25025 May 2011 Licensee Slides from 5/25/11 Public Meeting ML1107703492011-03-22022 March 2011 3/22/11 PRE-Application Meeting Slides Regarding NFPA 805 License Amendment Request ML1108206992011-03-22022 March 2011 3/22/11 Revised Pre-application Meeting Slides Regarding NFPA 805 License Amendment Request ML1013802102010-05-18018 May 2010 5/18/2010 Point Beach Public Meeting Slides ML1011304972010-04-22022 April 2010 NRC Slides for Point Beach End-of-Cycle Public Meeting ML1011304452010-04-22022 April 2010 FPL Energy Point Beach Handout from End-Of-Cycle Public Meeting ML0921107842009-07-29029 July 2009 Meeting Slides, Public Meeting with NRC Region III on Point Beach ML0912007342009-04-29029 April 2009 NRC Slides for Point Beach 2008 End-of-Cycle Public Meeting ML0912007042009-04-29029 April 2009 Presentation at 2008 End-of-Cycle Public Meeting ML0912007212009-04-29029 April 2009 NRC Presentation Handouts for Point Beach 2008 End-of-Cycle Public Meeting ML0828905272008-10-14014 October 2008 Meeting with NRC on AST ML0826819412008-09-24024 September 2008 Meeting Slides, FPL Energy Point Beach Public Meeting with NRC Region III ML0825401402008-09-16016 September 2008 Meeting Slides Point Beach Nuclear Plant Meeting with NRC on Epu. ML0819905262008-07-16016 July 2008 EOC Annual Assessment Meeting Slides ML0709403182007-03-28028 March 2007 EOC Summary Meeting Slides - 2007, Reactor Oversight Program - Cy 2006 ML0705106742007-02-21021 February 2007 NMC Slides for Public Meeting, Conduct of Operations Action Plan Update. ML0632601422006-11-21021 November 2006 11/21/2006 Informational Meeting Regarding Prairie Island License Renewal Application ML0615106012006-05-23023 May 2006 EPRI HRA Users Group Review of Draft NUREG-1842 ML0609307552006-04-0303 April 2006 Public Meeting Summary - Point Beach Safety Culture Meeting (Includes NMC Slides) ML0524903212005-08-25025 August 2005 Slides for Point Beach CAL Public Meeting Summary - August 25, 2005 ML0508304892005-03-14014 March 2005 Confirmatory Action Letter Public Meeting Slides ML0509200092005-03-0303 March 2005 3/3/05 - Preliminary Results of Environmental Review Point Beach Nuclear Plant, Units 1 and 2, Nuclear Regulatory Commission, March 3, 2005 ML0434900602004-11-30030 November 2004 NMC Slides for 11/30/04 Public Meeting ML0425404652004-08-18018 August 2004 Nuclear Management Co Confirmatory Action Letter Public Meeting Presentation Regarding Point Beach Nuclear Plant ML0508303502004-05-11011 May 2004 E-Mail B. Kemp, NMC, to H. Chernoff, NRR, May 11 Rev 2. Ppt W/Att Slides Conference Call, May 11, 2004 ML0508303302004-05-11011 May 2004 Slides: Point Beach Unit 1, Spring 2004 RPV Head Inspection Results Conference Call Tuesday, May 11, 2004 W/Handwritten Notes ML0412602942004-04-21021 April 2004 Public Meeting Slides, Point Beach 2003 End-of-Cycle Assessment ML0412602192004-04-21021 April 2004 Public Meeting Licensee Slides, Point Beach 2003 End - of - Cycle Assessment 2022-06-30
[Table view] |
Text
NextEra Approach to Resolution of Tornado Missile Protection Point Beach Nuclear Plant Units 1 & 2 May 1, 2018
AGENDA
INTRODUCTIONS
- Steve Catron, Fleet Licensing Manager
- Anil Julka, Reliability & Risk Manager
- Eric Schultz, PB Licensing Manager
- Lori Christensen, PB Licensing Project Manager
CURRENT STATUS
- Initial Nonconformance Declaration (U1 & U2)
- Turbine Driven Auxiliary Feedwater Pumps (TDAFPs) for unprotected steam supply piping
- Extent of Condition (U1 & U2)
- TDAFPs for unprotected turbine exhaust stacks
- Main Steam Isolation Valves, Main Steam Safety Valves, Atmospheric Dump Valves
- Emergency Diesel Generator (EDG) Fuel Oil Storage Tank T-175B Station implemented enforcement discretion guidance documents EGM 15-002 and DSS-ISG-2016-01
COMPENSATORY MEASURES
- Immediate Compensatory Measures
- Per DSS-ISG-2016-01 guidance
- Comprehensive Compensatory Measures
- Procedurally controlled measures
- FLEX equipment sharing
- Other Discernable Changes from Original Station Design
- FLEX implementation
- Station modifications (design basis and beyond design basis)
Compensatory measures in place; original station design improved over time and enhanced ability to mitigate a tornado missile event
RESOLUTION STRATEGY
- The resolution strategy is to validate that Tornado Missile is not a significant hazard for the site
- LAR submittal and approval will clear nonconformances
- Options Considered for LAR Development
- TMRE (Point Beach was a pilot plant)
- Site-specific High Winds PRA (RG 1.200, Rev. 2)
- Site-specific High Winds PRA (RG 1.200, Rev. 2)
License Amendment Request will screen out tornado missile as a significant hazard for the site
RESOLUTION STRATEGY
- Industry leader
- Developed in 2013 Updated to reflect as-built/as-operated plant Site-specific High Winds PRA is peer-reviewed to ASME Standard and Regulatory Guide 1.200, Revision 2
CONCLUSION
- License Amendment Request submittal based on Site-Specific High Winds PRA
- Site PRA concludes Tornado Missile is below the regulatory threshold in the Standard Review Plan and screens out as a significant hazard
- Plan to submit LAR in second half of 2018 License Amendment Request will screen out tornado missile as a significant hazard for the site