ML18079B104

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in IE Insp Rept 50-272/79-19.Corrective Actions:Training Folders for Each Licensed Operator Have Been Updated to Reflect Actual Training Status
ML18079B104
Person / Time
Site: Salem 
Issue date: 08/27/1979
From: Schneider F
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18079B103 List:
References
NUDOCS 7910120329
Download: ML18079B104 (2)


Text

e.

Frederick W. Schneider Vice President Public Service Electric and Gas Company 80 Park Place Newar.k, N.J. 07101 201 /430-7373 Production Mr. Boyc:e

  • H. Grier..

Director of USNRC Off ice of Inspection and Enforcement Region i 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr.* Grier:

NRC INSPECTION REPORT NO.* 50-272/79-19 MAY 24-25 and May 30-31,.1979 UNIT NO. 1 SALEM GENERATING STATION A~gust 27,.1979 We have reviewed the report of your inspection conducted on May 24-25 and May 30-31, 1979,.which was transmitted with your letter of August 8, 1979,.and received on August 10,.1979.

The item of non-

. compliance in Appendix A of your. report is as follows:

Item 4.b - Deficiency 10CFR 55, Appendix A, states,.in part:

"Records of the requalifica-tion program sh~ll be maintained *.* to* document the participation of each *licensed operator.and senior operator in the requalif ication program."

Salem Generating Station Training Procedure 10, NRC Licensed Oper-ator Re*quaLi..fication Program, states, in part:

"A training folder will be *maintained by the training staff for each licensed operator for the life of* his license.

The folder will contain *** Qualifica-tion Card for Overall Plant Operating and Emergency Instructions *.* "

Contrary to the above, *although the Requalification Log shows ap-pr*opriate *o.perating and emergency instruction training and simula-tion was conducted in 1978,* none *of the selected ind.l.vidual opera-tors' training folders reviewed contained the aforementioned *Quali-fication Cards for the year 1978, as required by TP-10 to implement the provisions of 10CFR 55,.Appendix A, Paragraph 5.

Mr. B.H. Grier 2 -

8-27-79 Our response is as follows:

1.

The cause of the Deficiency was failure of the training staff to verify.that the folders were maintained in accordance with the procedure.

2.

To correct the situation, training folders have been updated to reflect actual training status *.

3.

To prevent future items of noncompliance, the training staff will more closely supervise record keeping.

Training Pro-cedure 10 shall be revised to clarify the requirements.

Sta-tion QA Engineer shall follow up on this activity by surveil-lance or audit.

4.

We are in compliance now.

The revision to procedure TP-10 shall be completed by October 1, 1979.

If you-require additional information, we will be pleased to discuss it with you.

Sincerely, CC:

Director, Office of Inspection

& Enforcement USNRC Washington, D.C.