REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS) ij.'.

ACCESSION NBR 8712230032 DOC. DATE: 87/12/ 1 b NOTARIZED: NO DOCKET ¹ FAC IL: 50-335 St. Lucie PlantI Unit ii Florida Potuer & Light Co. 05000335 50-389 St. Lucie Planti Unit 2I Florida Poeer & Light Co. 05000389 AUTH. NAME AUTHOR AFFILIATION OODYI C. O. Florida Power & Light Co.

RECIP. NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards results on nonradiological confirmatory measurements samples anag ised during Insp Rept 50-335/87-24

& 50-389/87-23'er WJ Ross request. Part of sample 8bC sent to BNL. Results of analysis requested.

DISTRIBUTION CODE: IEObD COPIES RECEIVED: LTR i ENCL Q ofSIZE:

TITLE: Environ & Radiological (50 DKT)-Insp Rept/Notice Violation Respons NOTES:

RECIPIENT COPIES RECIPIENT COP IES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-2 LA 1 0 PD2-2 PD 1 1 TOURIGNYI E 1 1 INTERNAL: AEOD/DOA 1 1 AEOD/DSP 1 NMSS/LLOB 1 NMSS/SGOB 1 1 NRR/DLPG/PEB 1 1 NRR/DOEA/EAB 1 1 NRR/DREP/EPB 1 1 NRR/DREP/RPB 2 2 NA~ ILRB 1 1 OGC/HDS2 1 1 REG & 02 1 1 RES 1 1 RES DEPY GI 1 1 RGNZ FILE 01 1 1 RGN2/DRSS/EPRPB 1 RGN4 MURRAY' 1 1 EXTERNAL: LPDR 1 1 NRC PDR 1 1 NSIC 1 TOTAL NUMBER OF COP I ES REQUIRED: L'TTR 23 ENCL 22

P. O. BOX 14000, JUNO BEACH, FL 33408.0420 OEGEMBFR 1 6 19oi L-87-512 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Gentlemen:

Re: St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Ins ection Re ort 335 87-24 and 389 87-23 As requested by W.J. Ross, NRC Region II staff, attached are the results of the non-radiological confirmatory measurements samples analyzed during the subject inspection.

As requested by Mr. Ross, part of sample N86C was sent to the Brookhaven National Laboratory Safety and Environmental Protection Division in Upton, New York. FPL requests the results of their analysis.

There is no proprietary information in this report.

Very truly yours, C. O. W

'o Group President Nuclear Energy COW/GRM/gc Attachment cc: Dr. Z. Nelson Grace, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant 8712230032 871216 PDR ADQCK 05000335 9 PDR

/ye4 an FPL Group company

Brookhaven National Lab Samples a'nalyzed by St. Lucie Plant Week of November 3, 1987 (Results in units of ppb except Boron = ppm)

Lucie Analyses Results Sample Test Tech Tech Tech Tech Actual I.D. Method ¹ 1 ¹ 2 ¹-3 ¹ 4 Value 86A Cl- Dionex 18 23 22 20 Cl- HgN03 <50 20 Cl- SpecIon 18 18 22 20 F- Dionex 23 20 21 20 S04- Dionex 21 22 21 20 86B Cl- Dionex 36 '37 40 -- 40 C1- HgN03 <50 40 Cl- SpecIon 41 46 34 40 F- Dionex 43 39 46 40 F- el ~

SpecIon 41 46 ~

40 S04- Dionex 40 40 43 40 86C Cl-(M) SpecIon 10000 F-(M) SpecIon 75 86D B- 960-A 1000 E B- 2896-A 3000 F B- 4800-A 5000 86G Fe/Cu A/Aoven 3/4 5/5 4/5 -- 5/5 H Fe/Cu A/Aoven 6/8 9/10 9/11 -- 10/10 I Fe/Cu A/Aoven 9/12 12/15 13/16 -- 15/15 86J Na+ A/Aoven 8 10 5B 5B 5 K Na+ A/Aoven 14 20 10 B 11 B 10 L Na+ A/Aoven 50 60 16 B 16 B 15 86M NH'3+ ColMetr 120 140 120 -- 94.5 N NH3+ ColMetr 300 310 290 -- 283.

0 NH3+ ColMetr 920 900 920 -- 944.

86P N2H4 ColMetr 22 22 20 20 Q N2H4 ColMetr 56 56 55 50 R N2H4 ColMetr 110 108 110 100 86S, Si02 ColMetr 60 55 53 -- 50 T Si02 ColMetr 100 100 100 -- 100 U Si02 ColMetr 150 140 152 -- 150 A = Not enough sample to do triplicate and results suspected low due to some std. material not transferred to test sol n. A follow up sample will be sent to us for retest of Boron.

B = A second set of samples made up due to suspected contamination of samples analyzed by Tech s 1 & 2.

(M)= This sample anaylzed in matrix'of 700ppm Boron & 1.5ppm Lithium