MONTHYEARML12207A2612012-08-0101 August 2012 Redacted, Request for Additional Information, License Amendment Request to Revise Technical Specification (TS) 2.1.1.2, TS 4.2.1, and TS 5.7.1.5, to Support Unrestricted Use of Areva Fuel Project stage: RAI ML12220A0492012-08-0707 August 2012 Request for Additional Information Email, Round 2, License Amendment Request to Revise Technical Specification (TS) 2.1.1.2, TS 4.2.1, and TS 5.7.1.5, to Support Unrestricted Use of Areva Fuel Project stage: RAI ML12237A0202012-09-0404 September 2012 Summary of Telephone Conference Issues Associated with License Amendment Request Related to Transition to Areva Fuel Project stage: Other ML12263A3002012-09-14014 September 2012 Response to Request for Additional Information Regarding License Amendment Request for Permanent Use of Areva Fuel and for Permanent Exemption to Use M5 Cladding Project stage: Response to RAI ML12275A4182012-09-27027 September 2012 Response to Request for Additional Information Question 11 Regarding License Amendment Request for Permanent Use of Areva Fuel and for Permanent Exemption to Use M5 Cladding Project stage: Response to RAI ML12272A0922012-09-28028 September 2012 License Amendment Request Areva Fuel Vqp; SCE-9801-P-A SER Pages of Interest Project stage: Request ML12283A2302012-10-0909 October 2012 Request for Additional Information Email, Round 3 W/Corrected Due Date, Request to Revise Technical Specification (TS) 2.1.1.2, TS 4.2.1, and TS 5.7.1.5, to Support Unrestricted Use of Areva Fuel Project stage: RAI ML12283A2252012-10-0909 October 2012 Request for Additional Information Email, Round 3, Request to Revise Technical Specification (TS) 2.1.1.2, TS 4.2.1, and TS 5.7.1.5, to Support Unrestricted Use of Areva Fuel Project stage: RAI ML12310A4082012-11-0505 November 2012 Response to Request for Additional Information Regarding License Amendment Request for Permanent Use of Areva Fuel and for Permanent Exemption to Use M5 Cladding Project stage: Response to RAI ML12320A2772012-11-30030 November 2012 Regulatory Audit Request for Amendment Request to Revise Technical Specifications (Tss) 2.1.1, 4.2.1, and 5.7.1.5; Exemption Request for Permanent Unrestricted Use of Areva Fuel Project stage: Other ML13051A4512013-02-15015 February 2013 Response to Request for Additional Information Regarding License Amendment Request for Permanent Use of Areva Fuel and for Permanent Exemption to Use M5 Cladding Project stage: Response to RAI ML13081A0192013-03-19019 March 2013 Response to Request for Additional Information Regarding License Amendment Request for Permanent Use of Areva Fuel and for Permanent Exemption to Use M5 Cladding Project stage: Response to RAI ML13105A1992013-04-11011 April 2013 Response to Request for Additional Information Regarding License Amendment Request for Permanent Use of Areva Fuel and for Permanent Exemption to Use M5 Cladding Project stage: Response to RAI ML13183A4122013-07-0101 July 2013 Withdrawal of Amendment Applications 261 and 249 Proposed Change Number (PCN) 600, Unrestricted Use of Areva Fuel Project stage: Withdrawal ML13177A2872013-07-0808 July 2013 Letter, Notice of Withdrawal of Application for Amendment to Revise Technical Specification (TS) 2.1.1, TS 4.2.1, and TS 5.7.1.5; Exemption Request for Permanent Unrestricted Use of Areva Fuel (TAC ME6820-ME6823) Project stage: Withdrawal NRC-2013-0155, FRN, Notice of Withdrawal of Application for Amendment to Revise Technical Specification (TS) 2.1.1, TS 4.2.1, and TS 5.7.1.5; Exemption Request for Permanent Unrestricted Use of Areva Fuel (TAC Nos. ME6820-ME6823)2013-07-0808 July 2013 FRN, Notice of Withdrawal of Application for Amendment to Revise Technical Specification (TS) 2.1.1, TS 4.2.1, and TS 5.7.1.5; Exemption Request for Permanent Unrestricted Use of Areva Fuel (TAC Nos. ME6820-ME6823) Project stage: Withdrawal ML13177A2902013-07-0808 July 2013 FRN, Notice of Withdrawal of Application for Amendment to Revise Technical Specification (TS) 2.1.1, TS 4.2.1, and TS 5.7.1.5; Exemption Request for Permanent Unrestricted Use of Areva Fuel (TAC Nos. ME6820-ME6823) Project stage: Withdrawal ML13150A2202013-11-27027 November 2013 Withdrawn_San Onofre, Units 2 and 3 - Request for Withholding Information from Public Disclosure - 3/19/13 Affidavit Executed by V. Nazareth, Nuclear Fuel Management, SONGS, Response to Request for Additional Information Project stage: RAI 2012-09-28
[Table View] |
|
---|
Category:Meeting Summary
MONTHYEARML23206A2062023-07-28028 July 2023 Summary of July 17-18 2023 Routine Site Visit at SONGS 1 2 and 3 ML22206A1172022-08-18018 August 2022 Summary of July 21, 2022 Meeting with the National Marine Fisheries Service on Endangered Species Act Consultation for the San Onofre Nuclear Generating Station, Units 2 and 3, Decommissioning ML22062B6452022-03-10010 March 2022 02/02-03/2022 Summary of Routine Site Visit at San Onofre Nuclear Generating Station, Units 1, 2 and 3 ML22061A2152022-03-0808 March 2022 Summary of Teleconference with the National Marine Fisheries Services on Endangered Species Act Consultation for SONGS, Units 2 and 3 Decommissioning ML21075A2832021-03-17017 March 2021 Summary of Pre-Submittal Teleconference with Soutern California Edison on Request for Proposed Exemption to 10 CFR 72.106(B) (L-2021-LRM-0027) ML19263A6602019-09-24024 September 2019 SONGS NEIMA 108 Public Meeting Summary ML19164A3322019-06-24024 June 2019 Meeting Summary - NRC Decision on Southern California Edison Fuel Transfer Operations = June 3, 2019 ML19092A3942019-04-0505 April 2019 March 25, 2019 NRC Public Meeting/Webinar Summary ML18318A2952018-11-14014 November 2018 Special Inspection Webinar; Meeting Summary ML18319A1392018-11-14014 November 2018 Public Meeting Summary, Special Inspection Webinar ML14321A7192015-04-0808 April 2015 Summary of Meeting with Southern California Edison to Discuss Proposed Changes to the Emergency Preparedness Plan at San Onofre, Units 2 and 3 ML14314A0192015-04-0808 April 2015 Summary of Meeting with Southern California Edison Regarding Planned Quality Assurance Plan Changes for San Onofre, Units 2 and 3 ML14351A3962015-03-0909 March 2015 Summary of Meeting in Carlsbad, California to Discuss and Accept Comments Regarding the San Onofre Nuclear Generating Station Post-Shutdown Decommissioning Activities Report ML14321A7082015-02-24024 February 2015 9/24/2014 Summary of Meeting with Southern California Edison to Discuss Plans to Relocate Current Main Control Room to a Command Center During Decommissioning of San Onofre, Units 2 and 3 ML14216A4512015-02-0909 February 2015 7/31/14 Summary of Closed Meeting with Southern California Edison to Discuss Scope and Schedule Related to Cyber Security License Amendment Request for San Onofre Nuclear Generating Station, Units 2 and 3 ML13322A4222013-11-22022 November 2013 9/26/2013 - Summary of Category 3 Public Meeting in Carlsbad, CA, to Discuss the Regulatory Framework and the Decommissioning of Previously Operating Nuclear Power Plants ML13066A6322013-03-0606 March 2013 2/12/2013 - Summary of Category 3 Public Meeting Concerning the Current Status of San Onofre Nuclear Generating Station ML13017A1122013-02-13013 February 2013 G20120891 - Summary of 1/16/2013 Meeting with Petitioner 2.206 Petition, Richard Ayres, Friends of the Earth 11/16/12 Letter and 10 CFR 50.59 Review for the Replacement Steam Generators at San Onofre ML12346A1162012-12-10010 December 2012 Meeting Summary for November 30, 2012, Meeting with Southern California Edison Company ML12339A0842012-11-30030 November 2012 SONGS Meeting Summary 11-30-12 ML12237A0202012-09-0404 September 2012 Summary of Telephone Conference Issues Associated with License Amendment Request Related to Transition to Areva Fuel ML12179A4472012-06-26026 June 2012 6/18/2012 Meeting Summary for Augmented Inspection Team Exit Meeting with Southern California Edison Co ML12157A2722012-06-11011 June 2012 5/31/2012 Summary of Telephone Conference with Licensees Regarding Near Term Task Force Recommendation 2.1 Seismic Reevaluations - Diablo Canyon, 1 and 2, San Onofre, Units 2 and 3, Columbia Generating Station, and Palo Verde, Units 1, 2, a ML1210903952012-06-0707 June 2012 04/7/2011 Summary of Meeting with Southern California Edison to Discuss Future San Onofre, Units 2 and 3, License Amendment Submittal Related to Adoption of Risk-Informed NFPA-805 ML1115304302011-06-0101 June 2011 Meeting Summary for Public Meeting with Southern California Edison to Present & Discuss the Performance Results for San Onofre Nuclear Generating Station Units 2 & 3 for Period of January 1 Through December 31, 2010 ML1027304522010-09-30030 September 2010 Meeting Summary for 09/16/2010 Public Meeting with Southern California Edison ML1009505142010-04-0505 April 2010 Meeting Summary for Public Meeting with Southern California Edison Company on San Onofre Nuclear Generating Station 2009 Performance ML0932402122009-11-20020 November 2009 Summary of Public Meeting with Southern California Edison Company on San Onofre Nuclear Generating Station 2009 Performance ML0926502992009-09-22022 September 2009 Summary of Public Meeting with Southern California Edison Regarding Site Improvement Initiatives ML0919506292009-06-22022 June 2009 Summary of Meeting with Southern California Edison Company to Discuss the San Onofre Nuclear Generation Station Site Improvement Initiatives ML0914905092009-05-28028 May 2009 Summary of Meeting with Southern California Edison Company Several Initiatives That Were Being Implemented to Improve Licensed Operator Training at San Onofre Nuclear Generating Station ML0902803782009-02-0505 February 2009 Summary of Closed Meeting with Representatives of Southern California Edison Company to Discuss Security Plan Changes During Steam Generator Replacement Outages at San Onofre Nuclear Generating Station, Units 2 and 3 ML0833607102008-12-0303 December 2008 Summary of Closed Meeting with Southern California Edison Company, Regarding San Onofre Nuclear Station, Units 2 and 3 ML0832408112008-12-0303 December 2008 Summary of Conference Call with Southern California Edison Representatives, Discussions on San Onofre Unit 3 Steam Generator Tube Inspections ML0832502332008-12-0202 December 2008 Summary of Public Meeting with Operators of Vogtle Units 1 & 2, San Onofre Units 2 & 3, St. Lucie Unit 1, Turkey Point Unit 3, Indian Point Units 2 & 3, Nuclear Energy Institute, and Alion Science and Technology ML0822602532008-08-12012 August 2008 Summary of Meeting on with Southern California Edison Co Regarding the End-of-Cycle Assessment of San Onofre Nuclear Generating Station ML0819303712008-07-11011 July 2008 Summary of Meeting with Southern California Edison to Discuss Release for Unrestricted Use of the Off-shore Portion of the Circulating Water System from San Onofre Nuclear Generating Station Unit 1 ML0727100022007-10-0404 October 2007 Summary of Meeting with Representatives of Southern California Edison, Licensee for San Onofre Nuclear Generating Station, Unit 3 - Evaluation of Indications in Control Element Drive Mechanism Penetration 56 as No Detectable Defect ML0720703362007-07-20020 July 2007 Summary of San Onofre Nuclear Generating Station End-Of-Cycle Public Meeting ML0719801012007-07-18018 July 2007 Summary of Meeting with Representatives of Southern California Edison Re San Onofre Nuclear Generating Station, Units 2 and 3 Re Amendment Request PCN-548, Rev. 2 - Battery and DC Sources Upgrades and Cross-Tie ML0634503052006-12-18018 December 2006 Summary of 11/17/2006 Discussions Steam Generator Tube Inspections - Refueling Outage 14 (TAC No. MD3204) - Letter to Licensee and Summary of Conference Call ML0627802182006-10-11011 October 2006 David Pilmer Ltr 8/22/06 Meeting with SCE Transmittal of Meeting Report About San Onofre Unit 1 Cooling Water Intake and Discharge System Sampling ML0616700832006-06-26026 June 2006 6/14/06 Public Meeting Summary on the Reactor Oversight Process ML0616701402006-06-16016 June 2006 (SONGS 2 and 3) - Summary of Meeting Dated 06/07/06 with Representatives of SCE ML0616700952006-06-0808 June 2006 Meeting Summary for End-of-Cycle Performance Assessment ML0616701242006-06-0808 June 2006 Meeting Summary - Discussion of Safety Conscious Work Environment and Nuclear Safety Culture at San Onofre ML0622700772006-05-23023 May 2006 Weld Overlay of Cast Material ML0613504112006-05-12012 May 2006 Summary of 05/03/2006 Meeting with Representatives of Southern California Edison to Discuss San Onofre Nuclear Generating Station Safety Conscious Work Environment and Nuclear Safety Culture ML0609502862006-04-0303 April 2006 SONGS 2, Summary of Jan 2006 Discussions of Steam Generator Tube Inspections ML0606901542006-03-0909 March 2006 SONGS 2 and 3 Summary of Meeting Dated 03/02/06 2023-07-28
[Table view] Category:Memoranda
MONTHYEARML22333B0922022-12-21021 December 2022 FY22 Nmss/Duwp Operating Experience Report ML22061A2152022-03-0808 March 2022 Summary of Teleconference with the National Marine Fisheries Services on Endangered Species Act Consultation for SONGS, Units 2 and 3 Decommissioning ML21280A1082021-10-0505 October 2021 (SONGS) - Clarification to Request for Additional Information Response, Dated 10/05/2021 ML21104A0662021-04-0808 April 2021 SONGS Response to Request for Additional Information (RAI) to Support Endangered Species Act Consultation 4-8-2021 ML21061A2322021-04-0707 April 2021 Memo to File for EA+FONSI-SONGS ISFSI DFP-CLEAN ML21075A2832021-03-17017 March 2021 Summary of Pre-Submittal Teleconference with Soutern California Edison on Request for Proposed Exemption to 10 CFR 72.106(B) (L-2021-LRM-0027) ML20094L1362020-04-0303 April 2020 Memorandum: Andrea Kock, San Onofre Nuclear Generating Station Lessons Learned from Canister Misalignment Event ML18229A2032018-08-17017 August 2018 Inspection Charter to Evaluate the Near-Miss Load Drop Event at San Onofre Nuclear Generating Station ML18173A0082018-06-20020 June 2018 Cancelling Numerous Inspection Report Numbers ML18129A2142018-04-23023 April 2018 American Nuclear Insurers - Notification of Change in the Number of Power Reactors in the Secondary Financial Protection (SFP) Program ML18094A8152018-04-0404 April 2018 SONGS ISFSI PSP Rev 1 Notice of Safeguards Memo ML17271A0532017-09-29029 September 2017 2017 Summary of Annual Decommissioning Funding Status Reports for Reactors in Decommissioning ML17053A5902017-02-24024 February 2017 Closeout of Generic Letter 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools. ML17032A0582017-02-0202 February 2017 Correction to Final Environmental Assessment Associated with the Partial Site Release of the Circulating Water System for the San Onofre Nuclear Generating Station, Unit 1 ML20034E4712016-12-0101 December 2016 Cdph Final Doc Rad Assessment Review Mesa Facility ML16176A3392016-10-28028 October 2016 Decommissioning Lessons Learned Report and Transmittal Memorandum ML16295A1282016-10-21021 October 2016 Completion of Action 6c from the SONGS Lessons Learned Report ML16111A0032016-04-25025 April 2016 Completion of Action Nos. 1a, 1b, and 2 Associated with Topic 1 of the San Onofre Steam Generator Tube Degradation Event Lessons Learned ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML20034D8982016-02-16016 February 2016 Dtsc Comments Re SONGS - Phase I & II - ESA Reports ML15015A4192015-03-0606 March 2015 Review of Lessons Learned from the San Onofre Steam Generator Tube Degradation Event ML14344A6302014-12-15015 December 2014 Close-out letter-California Facilities Preemption Safety Evaluation ML14198A4052014-07-21021 July 2014 Notice of 7/31/14 Closed Meeting with Southern California Edison to Discuss Scope and Schedule Related to Cyber Security License Amendment Request for San Onofre Nuclear Generating Station, Units 2 and 3 ML14175A5682014-06-25025 June 2014 Notice of Forthcoming Closed Meeting on 6/26/2014 with Southern California Edison to Discuss San Onofre Nuclear Generating Station Physical and Cyber Security Plans Related to Decision to Decommission the Two Units ML14128A2672014-05-22022 May 2014 Charter for the Review of the Vendor Oversight Program in Response to the Part 52 and San Onofre Steam Generator Tube Degradation Event Lesson Learned ML20034E5012014-04-10010 April 2014 Memo to File Mesa Assessment W_Itas_Ars ML14028A0282014-03-20020 March 2014 OEDO-14-00190 - Mark A. Satorius, EDO Memo San Onofre Nuclear Generating Station Steam Generator Tube Degradation Event Lessons Learned Review ML13273A3892013-09-30030 September 2013 Memo to Reynolds and Leeds from Dorman and Andersen SONGS Oversight Panel Closure ML13238A2832013-09-11011 September 2013 Notice of 9/26/2013 Category 3 Public Meeting in Carlsbad, CA, to Discuss the Regulatory Framework and the Decommissioning of Previously Operating Nuclear Power Plants ML13171A2922013-06-13013 June 2013 LTR-13-0540 - Bill Hawkins and Vinod Arora Email San Onofre Nuclear Generating Station (SONGS) Lessons Learn for Davis-Besse ML13154A4312013-06-0404 June 2013 Rai'S Following Ifib Analysis of Edison'S 2013 Decommissioning Funding Status Report for San Onofre Units 2 and 3 ML13122A1452013-05-0909 May 2013 Memo to File Clarification Call Related to Request to Revise License Condition and Technical Specifications to Require Compliance with Steam Generator Structural Integrity Performance Criterion to Be Demonstrated Up to 70% RTP ML13099A3582013-04-0909 April 2013 Oversight Panel Charter (Revision 1) ML13080A4572013-03-22022 March 2013 Notice of Meeting with Southern California Edison to Discuss NRC Staff'S Request for Additional Information Question #32 Compliance with San Onofre, Unit 2, Technical Specifications for Steam Generator Tube Integrity ML13065A0312013-03-0505 March 2013 SONGS 2012 IP 71111.11Q Control Room Observation Samples ML13066A6642013-03-0505 March 2013 Memo to R. Lantz from G. George Regarding 2012 IP 71111.11Q Control Room Observation Samples ML13046A1232013-02-15015 February 2013 2/27/2013 Notice of Forthcoming Meeting with Southern California Edison Company to Discuss Confirmation Action Letter ML13017A1122013-02-13013 February 2013 G20120891 - Summary of 1/16/2013 Meeting with Petitioner 2.206 Petition, Richard Ayres, Friends of the Earth 11/16/12 Letter and 10 CFR 50.59 Review for the Replacement Steam Generators at San Onofre ML13029A6162013-02-0707 February 2013 G20120891 - San Onofre, Units 2 and 3, Memo to File Audio Recording of 1/16/2013 Public Meeting with Friends of the Earth Regarding Its 10 CFR 2.206 Petition Requesting Action Against Southern California Edison ML13017A3462013-01-17017 January 2013 Oversight Panel Charter ML12347A2682012-12-27027 December 2012 G20120891 - 1/11/2013 - Forthcoming Meeting with Petitioner 2.206 Petition, Richard Ayres, Friends of the Earth 11/16/12 Letter and 10 CFR 50.59 Review for the Replacement Steam Generators at San Onofre, Units 2 and 3 ML13002A2362012-12-27027 December 2012 Revised Forthcoming Meeting with Petitioner Requesting Action Against Southern California Edison Company ML12341A1122012-12-0707 December 2012 Notice of Meeting with Southern California Edison to Discuss Its Response to Nrc'S Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 ML12347A0662012-12-0707 December 2012 Revised Notice of 12/18/12 Meeting with Southern California Edison to Discuss Its Response to Nrc'S Confirmatory Action Letter and Return to Service Report for San Onofre Nuclear Generating Station, Unit 2 ML12292A6242012-12-0404 December 2012 Final Response to SONGS TIA 2011-008 ML12255A3602012-09-13013 September 2012 C. Regan Memo Response to Request for Additional Information- San Onofre Nuclear Generating Station Unit 1-2012 Decommissioning Funding Status Report ML12257A3032012-09-13013 September 2012 Public Meeting Notice to Discuss the Nrc'S Current Regulatory Oversight Status of San Onofre Nuclear Generating Station ML12242A5182012-09-0404 September 2012 NRC Oversight of San Onofre Nuclear Generating Station(Song) Units 2 & 3 During Extended Shutdown, 9-4-12 ML12237A0202012-09-0404 September 2012 Summary of Telephone Conference Issues Associated with License Amendment Request Related to Transition to Areva Fuel 2022-03-08
[Table view] |
Text
September 4, 2012 MEMORANDUM TO: FILE FROM: Joseph M. Sebrosky /RA/
Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NOS. 2 AND 3 -
SUMMARY
OF TELEPHONE CONFERENCE RE: ISSUES ASSOCIATED WITH LICENSE AMENDMENT REQUEST RELATED TO TRANSITION TO AREVA FUEL (TAC NOS. ME6820 AND ME6821)
This memorandum summarizes a telephone discussion on August 20, 2012, between the U.S. Nuclear Regulatory Commission (NRC) staff and Southern California Edison (SCE, the licensee). The discussion related to a license amendment request (LAR) dated July 29, 2011, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML11215A090). The LAR is associated with the unrestricted use of AREVA fuel at San Onofre Nuclear Generating Station (SONGS) Units 2 and 3. SCE participants in the discussion included: Owen Thomsen, Vick Nazareth, Steve Sparks, Scott Swoope, Tom Remick, Stephanie Roberts, and Linda Conklin. NRC staff representatives included Paul Clifford, Mathew Panicker and Joe Sebrosky.
The original purpose of the call was to discuss the enclosed draft requests for additional information (RAIs) and to determine if any of the RAIs needed to be clarified before they were formally issued. Highlights from the phone call include the following:
- The enclosed RAIs will not be formally issued at this time. Instead the RAIs will serve as part of an agenda for an NRC staff audit of SCE calculations that support the LAR.
- The NRC audit is tentatively targeted for the week of October 22, 2012, at SONGS. The timing of the audit is subject to change and is dependent on SCE providing responses to RAIs provided in an August 1, 2012, letter (ADAMS accession number ML12207A261) in the September 2012 time frame. In particular, the response to the August 1, 2012, RAI number 11 will provide the staff with information such that it will be able to develop a confirmatory computer model to allow the staff to perform an independent analysis to support the review of the LAR. The plan is for the staff to perform the independent analysis prior to the audit so that any differences in the staffs analysis results and the licensees analysis results can be discussed during the audit.
- The staff stated that additional RAIs were possible and that any additional questions that the staff identified would be added to the RAIs found in the enclosure and documented in the audit plan. The purpose of documenting them in the audit plan is to identify the issues that the staff would be seeking to resolve by auditing the SCE calculations that support the LAR. The staff stated that it would develop the audit plan in accordance with the Office of Nuclear Reactor Regulation Office Instruction LIC-111, Regulatory Audits
(ADAMS Accession No. ML082900195). As a result of the audit the staff expects to identify whether or not RAIs will need to be issued.
- The staff indicated that as part of the audit plan it will identify the SCE calculations that the staff would like to review during the audit. SCE indicated that it would attempt to make the calculations available to the staff prior to the audit.
Docket Nos. 50-361 and 50-362
Enclosure:
Draft RAIs
ML082900195). As a result of the audit the staff expects to identify whether or not RAIs will need to be issued.
- The staff indicated that as part of the audit plan it will identify the SCE calculations that the staff would like to review during the audit. SCE indicated that it would attempt to make the calculations available to the staff prior to the audit.
Docket Nos. 50-361 and 50-362
Enclosure:
Draft RAIs DISTRIBUTION:
PUBLIC LPLIV Reading RidsNrrDorlLpl4 Resource RidsNrrDprPspb Resource RidsNrrDssSbpb Resource RidsNrrLAJBurkhardt Resource RidsNrrPMSanOnofre Resource RidsRgn4MailCenter Resource MPanicker, NRR/DSS PClifford, NRR/DSS/SNPB AMendiola, NRR/DSS/SNPB EBrown, NRR/DORL ADAMS Accession No. ML12237A020 *per email OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/DSS/SNPB NRR/LPL4/BC NRR/LPL4/PM JBurkhard MPanicker*
NAME JSebrosky (BClayton for) MMarkley JSebrosky DATE 9/4/12 8/30/12 8/22/12 9/4/12 9/4/12 Draft RAIs for SONGS AREVA Fuel
Introduction:
Based upon experience acquired in its review of WCAP-16500-P-A Supplement 1 involving the introduction of different CHF correlations in a COLSS/CPCS plant and the unintended consequences on the MSCU analyses, the staff is unwilling to accept SCEs engineering judgment regarding the impact of the AREVA fuel introduction on the MSCU methodology.
Please address the following RAIs.
- 1. Section 4.2.1 of Enclosure 2 to SONGS PCN 600 describes the impact of the AREVA fuel design on the core thermal-hydraulic MSCU methods. This section concludes that since the engineering and systematic factor uncertainties are less for the AREVA fuel design relative to the existing Westinghouse fuel, then the MSCU analysis for SONGS which determined the 1.31 design DNBR limit and its associated Probability Distribution Function (pdf) is bounding and conservative for AREVA fuel, for both mixed core and full AREVA core configurations. Following approved methods, generate a specific design DNBR limit and associated pdf using AREVA fuel specifications and uncertainties for the limiting mixed core and full core configuration. The impact of differences in calculated DNBR limits and associated pdfs on COLSS/CPCS setpoint analyses (e.g., ROPM, EPOL2/4, BERRi) and predicted fuel rod failures should be discussed.
- 2. Section 4.8.1.2 of Enclosure 2 to SONGS PCN 600 states that the impact of the new AREVA CHF is limited to the TORC code and that the CETOP-D code and on-line algorithms will not be modified.
- a. Provide tables of CETOP-D(CE-1) to TORC(CE-1, BHTP) correction factors as a function of AXPD, temperature, pressure and flow for the COLSS narrow range, CPCS wide range, and transient analysis range of operating conditions. Include a discussion of the impact of mixed core and full core configurations on these correction factors. Also, discuss any interpolation or extrapolation of these values within the reload methods.
- b. To demonstrate the conservatism of the proposed approach, perform a sample COLSS/CPCS MSCU evaluation using a modified CETOP-D code with the AREVA BHTP CHF correlation (along with associated DNBR pdfs and CETOP-TORC correction factors). Identify any dependence of the COLSS and CPC DNB POL uncertainty with AXPD, temperature, pressure, or flow between the two approaches.
- c. Describe the calculation of AOPM and ROPM using CETOP-D (CE-1) for AOOs and accidents with respect to a mixed core of Westinghouse and AREVA fuel.
Enclosure