Technical Specification Changes TS-431 and TS-418 Extended Power Uprate - Steam Dryer Benchmarking Report
ML060720303
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 03/09/2006
From: O'Grady B
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TAC MC3743, TAC MC3744, TAC MC3812, TVA-BFN-TS-418, TVA-BFN-TS-431
Download: ML060720303 (3)


Text

Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 Brian O'Grady Vice President, Browns Ferry Nuclear Plant March 9, 2006 TVA-BFN-TS-431 TVA-BFN-TS-418 U.S. Nuclear Regulatory Commission 10 CFR 50.90 ATTN:

Document Control Desk Mail Stop OWFN, P1-35 Washington, D. C. 20555-0001 Gentlemen:

In the Matter of

)

Docket Nos.50-259 Tennessee Valley Authority

)

50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) -

UNITS 1, 2, and 3 -

TECHNICAL SPECIFICATIONS (TS) CHANGES TS-431 AND TS-418 EXTENDED POWER UPRATE (EPU)

STEAM DRYER BENCHMARKING REPORT (TAC NOS.

MC3812, MC3743, AND MC3744)

During a teleconference between NRC and TVA on February 13, 2006, it was agreed that TVA would provide NRC with benchmarking, scale model testing, and stress analysis reports for BFN steam dryer performance under EPU operating conditions.

Enclosed is "GENE-0000-0049-6652-01,General Electric Boiling Water Reactor Steam Dryer Scale Model Test Based Fluctuating Load Definition Methodology - March 2006 Benchmark Report."

The report version in Enclosure 1 contains information that the General Electric Company (GE) considers to be proprietary in nature and subsequently, pursuant to 10 CFR 9.17(a)(4), 2.790(a)(4) and 2.790(d)(1), requests that such information be withheld from public disclosure. contains an affidavit from GE supporting this request.

contains the redacted version of the report, with the GE proprietary material removed, which is suitable for public disclosure.

DUO3 Primed orn rc paper

U.S. Nuclear Regulatory Commission Page 2 March 9, 2006 Additionally, in letters to NRC on December 19, 2005 (ADAMS Accession Nos. ML053560186 and ML053560194) concerning TS-418 and TS-431, TVA stated that a status report providing additional steam dryer performance information would be provided to NRC by March 31, 2006.

In that regard, the steam dryer scale model testing (SMT) final report will be provided to the NRC by April 15, 2006, and the dryer stress analysis report will be provided to the NRC by May 5, 2006.

These dates correspond to the dates given in the enclosure to the March 1, 2006, letter from NRC to TVA on the revised schedule for review of TS-418 and TS-431.

There are no commitments contained in this letter.

If you have any questions regarding this letter, please contact William D. Crouch, Site Licensing Manager, at (256) 729-2636.

Sincerely, Brian O'Grady : GE-NE-0000-0049-6652-O1P (proprietary version) : GE-NE-0000-0049-6652-O1NP (non-proprietary version)

U.S. Nuclear Regulatory Commission Page 3 March 9, 2006 Enclosures cc (Enclosures):

U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, Georgia 30303-3415 Mr. Malcolm T. Widmann, Branch Chief U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, Georgia 30303-3415 NRC Senior Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road Athens, AL 35611-6970 Margaret Chernoff, Senior Project Manager U.S. Nuclear Regulatory Commission (MS 08G9)

One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 Eva A. Brown, Project Manager U.S. Nuclear Regulatory Commission (MS 08G9)

One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739