MONTHYEARML23303A0662023-11-0606 November 2023 October 2023 Environmental Scoping Meetings Re Perry Nuclear Power Plant License Renewal Application Meeting Summary Memo ML23187A4692023-07-0606 July 2023 Summary of the June 22, 2023, Public Outreach to Discuss the NRC 2022 End-of-Cycle Plant Performance Assessment of Perry Nuclear Power Plant ML23065A2192023-03-15015 March 2023 Second Safety Pre-Application Meeting Summary ML22258A0632022-09-26026 September 2022 July 21, 2022, Perry Nuclear Plant, Unit 1 License Renewal Environmental Pre-Application Meeting Summary - Letter ML22213A0362022-08-29029 August 2022 Safety Pre-Application Meeting Summary ML22147A0372022-05-31031 May 2022 Summary of the May 19, 2022, Public Outreach to Discuss the NRC 2021 End of Cycle Plant Performance Assessment of Perry Nuclear Power Plant ML21180A4632021-06-29029 June 2021 Summary of the June 22, 2021, Public Outreach to Discuss the NRC 2020 End-of-Cycle Plant Performance Assessment of Davis-Besse Nuclear Power Station, and Perry Nuclear Power Plant ML21055A2642021-03-0202 March 2021 Summary of February 16, 2021, Teleconference with Energy Harbor Nuclear Corp. to Discuss Potential License Amendment Request Related to Revising Flood Mitigation for Perry Nuclear Power Plant, Unit No. 1 ML20324A2192020-11-23023 November 2020 Summary of November 18, 2020, Teleconference with Energy Harbor Nuclear Corp. to Discuss Potential Changes to the Emergency Plan for Perry Nuclear Power Plant, Unit No. 1 ML20240A2942020-08-27027 August 2020 July 23, 2020 Summary of Public Webinar to Discuss the Nrc 2019 End-Of-Cycle Plant Performance Assessment of the Davis-Besse Nuclear Power Station and the Perry Nuclear Power Plant ML20163A6272020-06-15015 June 2020 Summary of Public Telecon with Energy Harbor on License Renewal for Perry Nuclear Plant ML19249C7652019-09-0404 September 2019 Summary of the July 17, 2019 Public Outreach/Open House to Discuss the NRC 2018 End-of-Cycle Plant Performance Assessment of the Perry Nuclear Power Plant ML18332A4122018-12-0303 December 2018 Summary of Public Teleconference Call with Firstenergy Nuclear Operating Company Regarding Proposed Revisions to the Emergency Plan ML18117A1672018-04-25025 April 2018 Summary of Public Outreach/Open House to Discuss the NRC 2017 End-Of-Cycle Plant Performance Assessment of Perry Nuclear Power Plant, Unit 1 ML18065A1392018-03-15015 March 2018 Summary of February 21, 2018, Public Meeting with Firstenergy Nuclear Operating Company Regarding a Proposed Revision to the Perry Nuclear Power Plant, Unit 1, Fire Protection Program ML17234A5542017-08-24024 August 2017 Summary of Telephone Conference with Firstenergy Nuclear Operation Co., Regarding Verbal Authorization of Relief Request to Use Alternative for Perry Nuclear Plant, Unit 1 ML17205A0242017-07-19019 July 2017 Summary of July 11, 2017, Open House to Discuss the 2016 End-of-Cycle Plant Performance Assessment of Perry Nuclear Power Plant ML17193A4192017-07-17017 July 2017 Summary of June 29, 2017, Public Meeting with Firstenergy Nuclear Operating Company Regarding a Proposed License Amendment Request for Perry Nuclear Power Plant, Unit 1, to Revise the Flooding Licensing Basis ML16321A0052016-11-21021 November 2016 Summary of November 9, 2016, Public Teleconference Call Regarding Upcoming Perry Nuclear Power Plant, Unit 1 License Amendment Request to Revise Technical Specifications to Support Implementation of Alternate Source Term Amendment ML16180A1352016-06-22022 June 2016 Summary of Open House Public Meeting to Discuss NRC Activities, Nuclear Power Issues, and 2015 End-of-Cycle Performance Assessment of Perry Nuclear Power Plant ML16053A3432016-02-24024 February 2016 2/9/16, Summary of Public Teleconference Call with Firstenergy Nuclear Operating Company Regarding Upcoming Perry Nuclear Plant, Unit 1 License Amendment Request to Revise Technical Specifications for Suppression Pool Water Level & Makeup S ML15280A2002015-10-0909 October 2015 Summary of Meeting with Firstenergy Nuclear Operating Company, on Fenoc'S Upcoming Request to Change Emergency Action Levels at Perry Nuclear Power Plant, Unit 1 ML15075A2462015-04-0808 April 2015 January 7 & 15, 2015 Summary of Meetings with Firstenergy Nuclear Operating Company to Discuss Alternative Source Term Implementation as a Result of Fuel Change ML14325A7782014-12-16016 December 2014 October 6, 2014, Summary of Pre-Application Meeting with Firstenergy Nuclear Operating Company to Discuss Proposed Combination of Site Emergency Plans ML14296A6892014-11-10010 November 2014 Summary of September 18, 2014, Meeting with Firstenergy Nuclear Operating Company to Discuss Alternative Source Term Implementation as a Result of Fuel Change ML14086A0592014-03-26026 March 2014 3/18/14 Summary of Public Meeting to Discuss the 2013 Perry End-of-Cycle Performance Assessment ML13113A3932013-04-23023 April 2013 4/10/2013 - Summary of Perry Public Meeting to Discuss the 2012 Annual Assessment Results ML13080A2502013-03-21021 March 2013 2/20/13 Summary of Meeting Regarding Inspection Procedure 95002 Inspection ML12277A4082012-10-0303 October 2012 September 26, 2012, Summary of Public Meeting to Discuss FENOC Fleet Performance ML12276A3362012-10-0202 October 2012 September 19, 2012 - Summary of a Public Meeting to Discuss Constellation Energy Nuclear Group, LLC (Ceng) Fleet Performance ML12195A1132012-07-16016 July 2012 Summary of Public Meeting with FENOC Regarding Licensing Practices and Processes ML12144A3202012-05-31031 May 2012 5/8/2012: Meeting Summary - Perry Presubmittal Meeting ML12102A2122012-04-11011 April 2012 4/5/2012 - Summary of Perry Public Meeting ML1123602872011-08-23023 August 2011 8/11/2011- Summary of Public Meeting to Discuss the Perry Nuclear Plant, Unit 1, End of Cycle Plant Performance Assessment ML1122002062011-08-0808 August 2011 Summary of June 26, 2011 Public Meeting to Discuss Constellation Energy Nuclear Group, LLC (Ceng) Fleet Performance ML1021702272010-08-0505 August 2010 Summary of Public Meeting with Firstenergy Nuclear Operating Company to Discuss the Perry Nuclear Power Plant, Unit 1, End-of-Cycle Plant Performance Assessment ML1009502432010-04-0505 April 2010 Meeting Summary of 3-31-10 Public Meeting with FENOC ML1003316682010-02-0202 February 2010 Summary of Public Meeting to Discuss Constellation Nuclear Energy Group Fleet Performance ML0932204092009-11-17017 November 2009 Summary of Public Meeting to Discuss Actions Taken by FENOC to Address Human Performance Substantive Cross-Cutting Issues ML0908600652009-01-28028 January 2009 01/23/09 & 01/28/09 Summary of Telecons Between NRC Staff and Prairie Island License Review Project ML0902605032009-01-22022 January 2009 Summary of Public Meeting to Discuss FENOC Fleet Performance (Davis-Besse, Perry, and Beaver Valley Nuclear Power Plant) ML0834706522008-12-30030 December 2008 Summary of Periodic Meeting with Firstenergy Nuclear Operating Company (FENOC) Staff on Licensing Action Status ML0811506052008-04-24024 April 2008 Summary of Public Meeting with Firstenergy Nuclear Operating Co. to Discuss the 2007 Perry End-of-Cycle Performance Assessment ML0802303062008-01-22022 January 2008 Summary of Meeting with FENOC to Discuss Fleet Performance NEI 06-04, Summary of 08/17/07 Closed Meeting with FENOC to Discuss Security Threat-Based Event Emergency Preparedness Drill Scenario at the Perry Nuclear Power Plant2007-08-21021 August 2007 Summary of 08/17/07 Closed Meeting with FENOC to Discuss Security Threat-Based Event Emergency Preparedness Drill Scenario at the Perry Nuclear Power Plant ML0723203812007-08-21021 August 2007 Summary of 08/17/07 Closed Meeting with FENOC to Discuss Security Threat-Based Event Emergency Preparedness Drill Scenario at the Perry Nuclear Power Plant ML0720701452007-08-0707 August 2007 Summary of June 27, 2007, Public Meeting Regarding Fenoc'S Re-analysis of the Time Line and Root Causes for the 2002 Davis-Besse Reactor Pressure Vessel Head Degradation Event ML0708607382007-03-27027 March 2007 Public Meeting Between NRC Region III and Firstenergy Nuclear Operating Company to Discuss the Nrc'S Assessment of Perry'S Safety Performance for the Period from 01/01/2006 - 12/31/2006 & Decision to Return Perry to Normal NRC Oversight ML0705401462007-02-26026 February 2007 Summary of Closed Meeting with Fenco to Discuss FENOC Fleet Security Issues ML0703101472007-01-29029 January 2007 Summary of Public Meeting with Beaver Valley, Davis-Besse, and Perry Nuclear Power Plants to Discuss FENOC Fleet Performance 2023-07-06
[Table view] |
Text
June 3, 2005 LICENSEE: FirstEnergy Nuclear Operating Company FACILITY: Perry Nuclear Power Plant, Unit 1
SUBJECT:
SUMMARY
OF THE MAY 26, 2005, PUBLIC MEETING TO DISCUSS THE RESULTS OF THE 95003 INSPECTION CONDUCTED AT PERRY FROM JANUARY THROUGH MAY 2005 On May 26, 2005, the Nuclear Regulatory Commission (NRC) held a public meeting at the Quail Hollow Resort in Painesville, Ohio. The meeting was between the NRC Headquarters Management, Region III Management and IP 95003 Team Leads, and FirstEnergy Nuclear Operating Companys Perry Management to discuss the results of the 95003 inspection conducted at Perry from January through May 2005. The meeting notice, NRC presentation, and licensee presentation can be found in ADAMS as ML051330317, ML051520311, and ML051520283 respectively. A list of NRC and licensee meeting participants can be found in the attached Enclosure.
The NRC began the meeting with an overview of the NRCs Reactor Oversight Process, the Action Matrix, and the scope and goals of a 95003 inspection. This was followed by a discussion of the results of the 95003 inspection at Perry and the teams subsequent assessment of Perrys performance. The NRC concluded with a discussion of upcoming activities at Perry and contact information for members of the public.
The licensees presentation responded to the 95003 teams assessment of the licensees performance and specifically addressed their efforts to resolve the issues identified by the 95003 inspection team. The licensee described their activities during the recent refueling outage, including hardware improvements designed to improve equipment performance. The licensees management described their Performance Improvement Initiative, how it works, and the implementation status.
FirstEnergy Nuclear Operating Company At the conclusion of the meeting, time was allotted for public comments and questions. Several members of the licensees staff asked questions of the NRC regarding the process by which we assess plant performance and the regulations and standards to which we base our assessments.
Sincerely,
/RA/
Christine A. Lipa, Chief Branch 4 Division of Reactor Projects Docket No. 50-440 License No. NPF-58
Enclosure:
As Stated See Attached Distribution DOCUMENT NAME: E:\Filenet\ML051540172.wpd To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RIII RIII NAME AGarmoe:dtp CLipa DATE 06/03/05 06/03/05 OFFICIAL RECORD COPY
FirstEnergy Nuclear Operating Company cc w/encl: G. Leidich, President - FENOC L. Myers, Chief Operating Officer, FENOC J. Hagan, Senior Vice President Engineering and Services, FENOC Director, Site Operations Director, Regulatory Affairs W. OMalley, Manager, Maintenance Department Manager, Regulatory Compliance J. Messina, Director, Performance Improvement T. Lentz, Director, Nuclear Engineering Department F. von Ahn, Plant Manager, Nuclear Power Plant Department D. Jenkins, Attorney, First Energy Public Utilities Commission of Ohio Ohio State Liaison Officer R. Owen, Ohio Department of Health
FirstEnergy Nuclear Operating Company ADAMS Distribution:
GYS SPS1 RidsNrrDipmIipb GEG KGO RJP DRPIII DRSIII PLB1 JRK1
Enclosure Meeting Participants NRC G. Suh, Section Chief, NRR W. Macon, Perry Project Manager, NRR M. Satorius, Division Director, DRP, RIII E. Duncan, 95003 Team Lead C. Lipa, Branch Chief, DRP, RIII G. Wright, 95003 Part A Team Lead R. Powell, Senior Resident Inspector, Perry FirstEnergy Nuclear Operating Company F. von Ahn, Director, Site Operations, Perry R. Anderson, Vice President, Perry T. Lentz, Director, Site Engineering, Perry J. Lausberg, Manager, Regulatory Compliance, Perry F. Cayia, Director, Performance Improvement, Perry