November 23, 2020 LICENSEE:
Energy Harbor Nuclear Corp.
FACILITY:
Perry Nuclear Power Plant, Unit No. 1
SUBJECT:
SUMMARY
OF NOVEMBER 18, 2020, TELECONFERENCE WITH ENERGY HARBOR NUCLEAR CORP. TO DISCUSS POTENTIAL CHANGES TO THE EMERGENCY PLAN FOR PERRY NUCLEAR POWER PLANT, UNIT NO. 1 (EPID L-2020-LRM-0103)
On November 18, 2020, a Category I public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Energy Harbor Nuclear Corp. (EHNC, the licensee) via teleconference. The purpose of this meeting was for EHNC to provide information on a planned amendment request for Perry Nuclear Power Plant, Unit No. 1 (PNPP), related to revising the Emergency Plan on-shift staffing. The meeting notice and agenda dated October 28, 2020, are available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML20303A047 and ENHCs presentation slides are available at ADAMS Accession No. ML20324A099. A list of attendees is enclosed.
The licensee indicated that the potential license amendment revises the PNPP Emergency Plan to make, in part, the following changes to the Emergency Response Organization (ERO):
Standardize position titles and responsibilities to align with other EHNC sites.
Extend augmented ERO response times from 30 and 60 minutes to 60 and 90 minutes.
Establish facility activation criteria for the Technical Support Center (TSC), Operations Support Center and Emergency Operations Facility (EOF) and staffing of the Joint Information Center at the declaration of an Alert or higher classification Revise PNPP Emergency Plan Table 5.1 to reflect NRC Revised Table B-1 content for performance of EP functions at PNPP Eliminate the on-shift Radwaste Operator and references to on-shift maintenance positions and functions.
Separate command and control functions between the TSC and EOF to streamline augmented ERO staffing and reduce turnover of responsibilities during initial stages of the event.
The licensee indicated that the potential license amendment includes analysis of Table B-1 of NUREG-0654/FEMA-REP-1, Revision 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, dated November 1980 (ADAMS Accession No. ML040420012), and Revised Table B-1 functions as implemented in the PNPP Emergency Plan since the last approved revision. The NRC staff reminded EHNC that NUREG-0654/FEMA-REP-1, Revision 2, was published in December 2019 (ADAMS Accession No. ML19347D139) is available for use.
No members of the public participated in the meeting. No regulatory decisions were made at this meeting.
Please direct any inquiries to me at 301-415-2855, or Scott.Wall@nrc.gov.
Sincerely,
/RA/
Scott P. Wall, Senior Project Manager Plant Licensing Branch III Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-440
Enclosure:
List of Attendees cc: Listserv
Enclosure LIST OF ATTENDEES NOVEMBER 18, 2020, PUBLIC MEETING WITH ENERGY HARBOR NUCLEAR CORP.
PERRY NUCLEAR POWER PLANT, UNIT 1 PLANNED LICENSE AMENDMENT REQUEST RELATED TO EMERGENCY PLAN ON-SHIFT STAFFING Name Organization Scott Wall Nuclear Regulatory Commission (NRC)
Joseph Anderson NRC Michael Norris NRC Richard Kinard NRC Jeannette Arce NRC Raymond Hoffman NRC Jeff Morgan Energy Harbor Nuclear Corp. (EHNC)
Jim Emley EHNC Phil Lashley EHNC Rebecca Kerns EHNC Anthony Kledzik EHNC Glen Burnham EHNC Monica Ray EHNC
ML20324A219 OFFICE NRR/DORL/LPL3/PM NRR/DORL/LPL3/LA NRR/DORL/LPL3/BC NRR/DORL/LPL3/PM NAME SWall SRohrer NSalgado SWall DATE 11/19/2020 11/19/2020 11/23/2020 11/23/2020