MONTHYEARML23152A2552023-06-0505 June 2023 Summary of the May 17, 2023, Public Outreach to Discuss the NRC 2022 End-of-Cycle Plant Performance Assessment of Davis-Besse Nuclear Power Station ML22178A2312022-06-28028 June 2022 Summary of the June 22, 2022, Public Outreach to Discuss the NRC 2021 End-Of-Cycle Plant Performance Assessment of Davis Besse Nuclear Power Station ML22088A1972022-03-30030 March 2022 Summary of March 11, 2022, Call Regarding the Spring 2022 Steam Generator Tube Inspections ML22084A1022022-03-27027 March 2022 Reissue Summary of the February 1, 2022, Regulatory Conference Between Energy Harbor, Davis-Besse Nuclear Power Station and the Nuclear Regulatory Commission ML22077A8062022-03-23023 March 2022 Summary of the February 1, 2022, Regulatory Conference Between Energy Harbor, Davis-Besse Nuclear Power Station and the Nuclear Regulatory Commission ML21314A5362021-11-18018 November 2021 Summary of November 8, 2021, Meeting with Energy Harbor Nuclear Corp. Regarding Its Proposed Alternate for Examination of Steam Generator Welds at ML21180A4632021-06-29029 June 2021 Summary of the June 22, 2021, Public Outreach to Discuss the NRC 2020 End-of-Cycle Plant Performance Assessment of Davis-Besse Nuclear Power Station, and Perry Nuclear Power Plant ML20240A2942020-08-27027 August 2020 July 23, 2020 Summary of Public Webinar to Discuss the Nrc 2019 End-Of-Cycle Plant Performance Assessment of the Davis-Besse Nuclear Power Station and the Perry Nuclear Power Plant ML19249C7112019-09-0404 September 2019 Summary of the July 18, 2019 Public Outreach/Open House to Discuss the NRC 2018 End-Of-Cycle Plant Performance Assessment of the Davis-Besse Nuclear Power Station ML18313A1982018-11-14014 November 2018 Summary of Meeting with Firstenergy Nuclear Operating Company Regarding Planned Submittal of Post-Shutdown Emergency Plan for Davis-Besse Nuclear Power Station ML18192A6522018-07-10010 July 2018 Summary of Public Meeting to Discuss the 2017 End-of-Cycle Plant Performance Assessment of Davis-Besse Nuclear Power Station ML17258A1462017-09-20020 September 2017 Summary of September 12, 2017, Meeting with Firstenergy Nuclear Operating Company Regarding Its Licensing Amendment Request to Adopt National Fire Protection Association Standard 805 at Davis-Besse Nuclear Power Station, Unit No. 1 ML17229B1362017-08-16016 August 2017 Summary of July 19, 2017, Open House to Discuss the 2016 End-of-Cycle Plant Performance Assessment of Davis-Besse Nuclear Power Station ML17087A1882017-03-28028 March 2017 Summary of Closed Meeting with Firstenergy Nuclear Operating Company Regarding Changes to the Davis-Besse Nuclear Power Station, Unit No. 1, Security Plan ML16197A0522016-07-14014 July 2016 Summary of June 21, 2016, Public Meeting with Firstenergy Nuclear Operating Company to Discuss the 2015 End-of-Cycle Plant Performance Assessment of Davis-Besse Nuclear Station ML16130A7502016-05-12012 May 2016 Summary of April 12, 2016, Teleconference Regarding Steam Generator Tube Inservice Inspection ML14177A5782016-02-22022 February 2016 November 13, 2013, Summary of Meeting with Firstenergy Nuclear Operating Company to Discuss Delay in Submittal of Fire Risk Reduction Amendment Request ML16006A3512016-01-20020 January 2016 December 17,2015 Summary of Meeting with Firstenergy Nuclear Operating Company on Its License Amendment Request to Revise the Emergency Diesel Generator Surveillance Requirements at Davis-Besse Nuclear Power Station, Unit 1 ML16007A3962016-01-12012 January 2016 Summary of January 5, 2016, Meeting with Firstenergy Nuclear Operating Company on Its Planned License Amendment Request to Revise the Emergency Action Level Scheme at Davis-Besse Nuclear Power Station, Unit No. 1 ML15196A5162015-07-24024 July 2015 Summary of Telephone Conference Call Held on May 06, 2015, and May 19, 2015 Between the U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company ML15170A2862015-06-18018 June 2015 Summary of the Public Open House Regarding Davis-Besse Nuclear Power Station ML15089A1642015-04-27027 April 2015 Summary of February 25, 2015, Partially Closed Meeting with Industry Stakeholders Regarding the Babcock and Wilcox Loss of Coolant Accident Evaluation Model Analysis ML15056A4562015-04-20020 April 2015 Summary of Teleconference Call Held February 20, 2015, Between U.S. Nuclear Regulatory Commission and First Energy Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Power Station ML14325A7782014-12-16016 December 2014 October 6, 2014, Summary of Pre-Application Meeting with Firstenergy Nuclear Operating Company to Discuss Proposed Combination of Site Emergency Plans ML14224A6142014-08-12012 August 2014 Summary of Public Meeting to Discuss the 2013 Performance of Davis-Besse Nuclear Power Station ML14160B1032014-07-10010 July 2014 June 6, 2014 Summary of Meeting with FENOC Flooding Hazard Reevaluation Extension Request for Beaver Valley Power Station, Units 1 and 2 and Flooding Hazard Reevaluation Report for Davis-Besse Nuclear Power Station, Unit 1 ML14099A4642014-05-0606 May 2014 Summary of Public Meetings to Discuss Draft Supplement 52 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants Regarding Davis-Besse Nuclear Generating Station, Unit 1 ML14099A3392014-04-22022 April 2014 March 27, 2014, Summary of Telephone Conference Call Held Between Nuclear Regulatory Commission and First Energy Nuclear Operating Company Concerning Commitment 13 of the Safety Evaluation Report Pertaining to the Davis Besse Unit 1, Licens ML14080A1842014-03-21021 March 2014 Summary of Webinar Meeting to Discuss NRC Inspection Activities Associated with the Davis-Besse Nuclear Power Station Installation of Two New Steam Generators ML13240A0702013-08-29029 August 2013 8 22 2013 DB NRC Telecon Summary License Condition ML13225A2932013-08-12012 August 2013 7/23-24/2013, Summary of Meeting 2013 U.S. Nuclear Regulatory Commission (NRC) Initial Exam Writers' Workshop ML13197A2572013-07-17017 July 2013 5 28 2013 DB Hs Bolts Telecon Summary ML13182A4082013-07-17017 July 2013 Summary of Telephone Conference Call Held on October 16, 2012, Between NRC and FENOC, Concerning RAI Pertaining to the Davis-Besse Nuclear Power Station, LRA (TAC No. ME640) ML13149A2862013-07-12012 July 2013 Summary of Telephone Conference Call Held on May 2, 2013, Between the NRC and FENOC, Concerning RAI Pertaining to the Davis-Besse Nuclear Power Station License Renewal Application ML13182A4432013-07-12012 July 2013 Summary of Telephone Conference Call Held on April 11, 2013, Between the U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Powe ML13149A2882013-07-0909 July 2013 May 9, 2013, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Power Stat ML13168A2422013-06-14014 June 2013 6/11/2013 - Summary of Open House to Discuss the 2012 Davis-Besse Nuclear Power Station End-Of-Cycle Performance ML13091A3272013-03-29029 March 2013 Summary of Public Meeting to Discuss the Davis-Besse Replacement Activities ML13051A6602013-03-26026 March 2013 Summary of Telephone Conference Call Held on January 23, 2013, Between the NRC and FENOC, Concerning RAI Pertaining to the Davis-Besse Nuclear Power Station, LRA ML13051A0682013-03-26026 March 2013 January 16, 2013 Summary of Telephone Conference Call Held Between U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company ML13025A0272013-02-14014 February 2013 October 23, 2012 Summary of Telephone Conference Call Held Between the Nuclear Regulatory and Firstenergy Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Power Station, License ML12277A4082012-10-0303 October 2012 September 26, 2012, Summary of Public Meeting to Discuss FENOC Fleet Performance ML12243A2832012-08-30030 August 2012 Summary of Public Meeting to Discuss Nrc'S Review of Fenoc'S Root Cause Analysis of Davis-Besse Shield Building Cracks ML12237A0432012-08-24024 August 2012 August 15, 2012 - Summary of Public Meeting to Discuss the Davis-Besse Nuclear Power Station, Unit 1, End-Of-Cycle Plant Performance Assessment ML12195A1132012-07-16016 July 2012 Summary of Public Meeting with FENOC Regarding Licensing Practices and Processes ML12165A3502012-07-16016 July 2012 Summary of Conference Call for Stream Generator Tube Inservice Inspections for Spring 2012 Refueling Outage ML12052A1792012-05-15015 May 2012 July 19, 2011, Summary of Telephone Conference Call Between the U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Power Station ML12059A0782012-04-0202 April 2012 Summary of Telephone Conference Call Held on February 9, 2012, Between the U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Pow ML12061A2582012-04-0202 April 2012 Summary of Telephone Conference Call Held on July 12,2011, Between the U.S. Nuclear Regulatory Commission and Firstenergy Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the Davis-Besse Nuclear Power ML12031A1832012-03-0202 March 2012 Summary of Telephone Conference Call Held on July 13, 2011, Between the U.S. Nuclear Regulatory Commission and Firstentergy Nuclear Operating Company, Concerning Request for Additional Information Pertaining to the DA7 13 2011 DB NRC Teleco 2023-06-05
[Table view] |
Text
July 2, 2002 LICENSEE: FirstEnergy Nuclear Operating Company FACILITY: Davis-Besse Nuclear Power Station, Unit 1
SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1 - MEETING
SUMMARY
OF JUNE 4, 2002, TO DISCUSS THE REACTOR PRESSURE VESSEL CLOSURE HEAD REPLACEMENT On June 4, 2002, Nuclear Regulatory Commission management and staff conducted a public meeting in Rockville, Maryland, with representatives of FirstEnergy Nuclear Operating Company (FENOC). The purpose of the meeting was to discuss FENOCs decision to replace the reactor pressure vessel closure head (RPVCH) at the Davis-Besse Nuclear Power Station (DBNPS). A public notice that the meeting was to be held was issued on May 24, 2002. A telephone conference bridge was established for members of the public who were unable to attend. The meetings participants are included as Enclosure 1 and the licensees handouts are included as Enclosure 2.
The licensee has been pursuing the following three options with regard to the RPVCH:
- The repair plan option was discussed during the public meeting of April 10, 2002, and formally submitted for staff review on April 25, 2002. The repair plan has subsequently been deferred and the licensees letters dated June 14, 2002, requested that the staff suspend all review activities associated with the repair plan and related requests for relief from the American Society of Mechanical Engineers (ASME) Code.
- Last fall, the licensee ordered a new RPVCH which is scheduled for delivery in Spring 2004. The licensee investigated the possibility of stepping ahead of other licensee orders for new RPVCHs in order to accelerate delivery. However, the earliest delivery would be Fall 2003 which would not provide a prompt resolution.
- Purchase of an existing RPVCH was considered from the Midland, Rancho Seco, and Three Mile Island, Unit 2 facilities. The licensee has decided to purchase the RPVCH from the Midland, Unit 2, facility because it is similar in design to DBNPS, is readily available, and is not contaminated.
The licensee described the three-way contract it has signed with Consumers Power, owner of the Midland facility, and Framatome-Advanced Nuclear Power (FRA-ANP). FRA-ANP has purchased the Midland RPVCH as-is from Consumers Power and is reconciling it against the Davis-Besse design requirements. FRA-ANP will compile/validate the ASME Code Data Package for the RPVCH and then sell the RPVCH to FirstEnergy as safety-related equipment.
The following comparisons were made between the RPVCH at Midland and DBNPS:
- The Midland and DBNPS control rod drive nozzles and J-groove welds are constructed of similar materials. Therefore, the nozzles and J-groove welds will have the same susceptibility for cracking.
- The alignment of control rods to RPVCH nozzles is consistent with DBNPS. Therefore, the core geometry will remain unchanged.
- Minor machining of vessel-to-head key-way surfaces will be required to permit alignment between the RPVCH and the vessel.
- Minor differences exist in the RPVCH O-ring design. A slightly smaller diameter O-ring (0.455 inch versus 0.500 inch) will be installed.
The licensee described the following non-destructive examinations planned for the Midland RPVCH that will supplement the ASME Code Data Package:
- Radiography of flange-to-dome weld and nozzle-to-flange welds
- Magnetic particle and ultrasonic examination of flange-to-dome welds
- PT examination of peripheral CRDM nozzle-to-flange welds, and
- Eddy current testing of CRDM nozzles The licensee discussed the activities associated with removing the RPVCH from the Midland containment and constructing a temporary access opening in the Davis-Besse containment.
Prior to plant restart, the licensee will bring the plant to normal operating temperature and pressure using reactor coolant pump heat and perform visual inspections for leakage.
Following the technical meeting with the licensee, the staff took questions from members of the public.
/RA/
Douglas V. Pickett, Senior Project Manager, Section 2 Project Directorate III Division of Licensing Projects Management Office of Nuclear Reactor Regulation Docket No. 50-346
Enclosures:
- 1. Participants
- 2. Meeting Slides cc w/encls: See next page
- The alignment of control rods to RPVCH nozzles is consistent with DBNPS. Therefore, the core geometry will remain unchanged.
- Minor machining of vessel-to-head key-way surfaces will be required to permit alignment between the RPVCH and the vessel.
- Minor differences exist in the RPVCH O-ring design. A slightly smaller diameter O-ring (0.455 inch versus 0.500 inch) will be installed.
The licensee described the following non-destructive examinations planned for the Midland RPVCH that will supplement the ASME Code Data Package:
- Radiography of flange-to-dome weld and nozzle-to-flange welds
- Liquid-penetrant (PT) examination of the control rod drive mechanism (CRDM) nozzle J-groove welds
- Magnetic particle and ultrasonic examination of flange-to-dome welds
- PT examination of peripheral CRDM nozzle-to-flange welds, and
- Eddy current testing of CRDM nozzles The licensee discussed the activities associated with removing the RPVCH from the Midland containment and constructing a temporary access opening in the Davis-Besse containment.
Prior to plant restart, the licensee will bring the plant to normal operating temperature and pressure using reactor coolant pump heat and perform visual inspections for leakage.
Following the technical meeting with the licensee, the staff took questions from members of the public.
/RA/
Douglas V. Pickett, Project Manager, Section 2 Project Directorate III Division of Licensing Projects Management Office of Nuclear Reactor Regulation Docket No. 50-346
Enclosures:
- 1. Participants
- 2. Meeting Slides cc w/encls: See next page Meeting Slides: ML021560107 Package: ML021760495 Accession Number: ML021760534 OFFICE PM:PDIII-2 LA:PDIII-2 SC:PDIII-2 NAME DPickett THarris AMendiola DATE 07/01/02 07/01/02 07/02/02 OFFICIAL RECORD COPY
Davis-Besse Nuclear Power Station, Unit 1 cc:
Mr. Howard Bergendahl Carol OClaire, Chief, Radiological Branch Vice President-Nuclear, Davis-Besse Ohio Emergency Management Agency FirstEnergy Nuclear Operating Company 2855 West Dublin Granville Road Davis-Besse Nuclear Power Station Columbus, OH 43235-2206 5501 North State Route 2 Oak Harbor, OH 43449-9760 Zack A. Clayton DERR Mary E. OReilly Ohio Environmental Protection Agency FirstEnergy Corporation P.O. Box 1049 76 South Main St. Columbus, OH 43266-0149 Akron, OH 44308 State of Ohio Manager - Regulatory Affairs Public Utilities Commission First Energy Nuclear Operating Company 180 East Broad Street Davis-Besse Nuclear Power Station Columbus, OH 43266-0573 Oak Harbor, OH 43449-9760 Attorney General Director Department of Attorney Ohio Department of Commerce 30 East Broad Street Division of Industrial Compliance Columbus, OH 43216 Bureau of Operations & Maintenance 6606 Tussing Road President, Board of County P.O. Box 4009 Commissioners of Ottawa County Reynoldsburg, OH 43068-9009 Port Clinton, OH 43252 Regional Administrator President, Board of County U.S. Nuclear Regulatory Commission Commissioners of Lucas County 801 Warrenville Road One Government Center, Suite 800 Lisle, IL 60523-4351 Toledo, Ohio 43604-6506 Michael A. Schoppman Framatome ANP 1911 N. Ft. Myer Drive Rosslyn, VA 22209 Resident Inspector U.S. Nuclear Regulatory Commission 5503 North State Route 2 Oak Harbor, OH 43449-9760 Plant Manager, Randel J. Fast FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760 Dennis Clum Radiological Assistance Section Supervisor Bureau of Radiation Protection Ohio Department of Health P.O. Box 118 Columbus, OH 43266-0118
DISTRIBUTION FOR MEETING
SUMMARY
OF JUNE 4, 2002, WITH FIRSTENERGY NUCLEAR OPERATING COMPANY Hard Copy w/encls PD III-2 Reading PUBLIC GGrant, RIII Hard Copy w/Encl 1 OGC ACRS E-mail w/Encl 1 SCollins BSheron JZwolinski TMarsh CCasto WBateman KWichman AHiser SBajwa SCoffin SBloom MMarshall WCullen ALee DThatcher KNaidu AMendiola SSands DPickett THarris SRosenberg MKotzalas HNieh
LIST OF MEETING PARTICIPANTS JUNE 4, 2002 NRC FIRSTENERGY Bill Bateman Bob Schrauder Tony Mendiola Jim Powers Stephanie Coffin Mark McLaughlin Dale Thatcher Pat McCloskey Kamalakar Naidu Dave Lockwood FRAMATOME Mark Carpenter Bill Benhke NRC CONSULTANT Keith Wichman ENCLOSURE 1