UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 12, 2016 Mr. Brian D. Boles Site Vice President FirstEnergy Nuclear Operating Company Mail Stop A-DB-3080 5501 N. State Route 2 Oak Harbor, OH 43449-9760
SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO. 1 -
SUMMARY
OF APRIL 12, 2016, TELECONFERENCE REGARDING STEAM GENERATOR TUBE INSERVICE INSPECTION (CAC NO. MF7398)
Dear Mr. Boles:
On April 12, 2016, the U.S. Nuclear Regulatory Commission (NRC) staff participated in a teleconference with representatives of FirstEnergy Nuclear Operating Company (the licensee) regarding the inservice inspections of steam generators at Davis-Besse Nuclear Power Station, Unit No. 1. A summary of the teleconference and a list of participants are enclosed.
By letter dated February 29, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16057A865), the NRC staff provided questions for the licensee to address during the call. The licensee's handouts used during the call, which addressed the staff's questions, are available under ADAMS Accession No. ML16117A182.
If you have any questions, please contact me at (301) 415-1380.
Docket No. 50-346 cc: Distribution via Listserv
Enclosures:
- 1. Summary of Teleconference
- 2. List of Participants Sincerely, fl;l ;JVVZ/
Blake Purnell, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUMMARY
OF APRIL 12, 2016, TELECONFERENCE SPRING 2016 STEAM GENERATOR INSPECTIONS DAVIS-BESSE NUCLAER POWER STATION, UNIT NO. 1 DOCKET NO. 50-346 On April 12, 2016, the U.S. Nuclear Regulatory Commission (NRC) staff participated in a conference call with representatives of FirstEnergy Nuclear Operating Company (the licensee) regarding the ongoing steam generator (SG) inspection at Davis-Besse Nuclear Power Station (Davis-Besse), Unit No. 1. By letter dated February 29, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16057A865), the staff provided questions for the licensee to address during the call. The licensee's handouts used during the call, which addressed the staff's questions, are available under ADAMS Accession No. ML16117A182, and this information is not repeated here. Definitions of acronyms used by the licensee in its handouts are provided at the end of this summary.
Background
Davis-Besse has two once-through SGs designed by Babcock and Wilcox. These replacement SGs were installed in 2014. The tubes were hydraulically expanded for part of the length of the tubesheet and are supported by sixteen carbon steel tube support plates. The licensee stated that a number of adjustments were made in the design of their new SGs to mitigate tube-to-tube wear degradation. For example, the length of the tube-to-tubesheet expansion was adjusted to control the amount of preloading on the tubes.
The licensee stated that the integral orifice plate is in the downcomer region, and it is adjusted to set the water column height in the feedwater downcomer region of the SG. The licensee stated that tube support plate (TSP) 15S is below the auxiliary feedwater nozzle and has drilled holes in the periphery through which the tubes pass. The remaining portion of TSP 15S and the other TSPs in the SG have trefoil broached holes. The trefoil holes of the even numbered TSPs are offset from centerline to minimize tube wear at the TSP elevations.
Summary of Inspection Results At the time of the teleconference, SG tube inspections were ongoing and the information provided by the licensee did not represent final inspection results. The information provided by the licensee was for the point when the licensee had completed 65 percent of the inspections for SG 2A and 47 percent of the inspections for SG 1 B.
The licensee had identified 358 wear-like indications for SG 2A and 22 wear-like indications for SG 1 B. The licensee believes the higher number of indications found in SG 2A is due to a different length of secondary side piping that runs into SG 2A. The different length is due to the physical configuration of the plant. The licensee stated it had seen similar differences with its previous SGs.
The licensee had identified 142 locations in SG 2A and 20 locations in SG 1 B needing special interest exams. No tube-to-tube wear indications had been detected. The licensee stated that it had identified 182 wear indications at TSP 16S which were distributed amongst tubes in the periphery region. The periphery region has the highest crossflow velocities.
The licensee performed as-found visual inspections of the SG channel head, but the inspections were incomplete at the time of the call. The licensee stated it would notify NRC staff if any abnormalities are found.
The NRC staff did not identify any issues during the call that required follow-up action.
Acronyms Acronyms used in the licensee's document are defined below:
% TW - Percent Through-Wall ADI -
Absolute Drift Indication BLG - Bulge CAL - Calibration CHN - Channel CMOA - Condition Monitoring Operational Assessment COL - Column DB - Davis-Besse DOI - Distorted Dent/Ding Indication DEG - Degree ONG-Ding ONT-Dent OSI - Distorted Support Indication DTI - Distorted Tubesheet Indication EXT - Extent IDC - Inside Diameter Chatter LPI -
Loose Part Indication L TE -
Lower Tube End L TS - Lower Tubesheet MRPC - Motorized Rotating Pancake Coil NQI - Non-Quantifiable Indication OA - Operational Assessment OBS - Obstruction OD - Outside Diameter PLP - Possible Loose Part PVN - Permeability Variation SG - Steam Generator SVI - Single Volumetric Indication Tech Spec - Technical Specification TSP - Tube Support Plate TWO - Through-Wall Depth UTE - Upper Tube End UTS - Upper Tubesheet V-Volts VOL - Volumetric WAR-Wear
LIST OF PARTICIPANTS APRIL 12, 2016, TELECONFERENCE WITH FIRSTENERGY NUCLEAR OPERATING COMPANY (FENOC)
Name Affiliation Blake Purnell NRC Jennifer Hauser NRC Alan Huynh NRC Andrew Johnson NRC Tom Bilk NRC Thomas Briley NRC Phil Lashley FE NOC William Boudreaux FE NOC Steve Slosnerick FE NOC Victor Newman FE NOC Luke Twarek FE NOC Kevin Zellers FE NOC Alex Cullu FE NOC Kendall Johnson FE NOC
If you have any questions, please contact me at (301) 415-1380.
Docket No. 50-346 cc: Distribution via Listserv
Enclosures:
- 1. Summary of Teleconference
- 2. List of Participants DISTRIBUTION:
PUBLIC LPL3-2 r/f RidsNrrDorlLpl3-2 Resource RidsNrrLASRohrer Resource RidsNrrPMDavisBesse Resource RidsRgn3MailCenter Resource ADAMS A ccession N o.M L1613 A750 0
OFFICE DORL/LPL3-2/PM DORL/LPL3-2/LA NAME BPurnell SRohrer DATE 5/11/16 5/10/16 Sincerely, IRA/
Blake Purnell, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation RidsNrrDeEsgb Resource AHuynh, NRR AJohnson, NRR KKarwoski, NRR GKulesa, NRR DHills, Riii
- b 1y memo DE/ESGB/BC DORL/LPL3-2/BC (A)
GKulesa*
GE Miller 4/27/16 5/12/16 DORL/LPL3-2/PM BPurnell 5/12/16