PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 FEB @8 2006 O PSEG NuclearLLC LR-N06-0023 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-001 INSERVICE INSPECTION ACTIVITIES - 90 DAY REPORT AND REACTOR VESSEL HEAD INSPECTION SALEM GENERATING STATION UNIT NO. I SEVENTEENTH REFUELING OUTAGE: (1R17)

DOCKET NO. 50-272 FACILITY OPERATING LICENSE NO. I)PR-70 This letter submits the ninety (90) day report for Inservice Inspection (ISI) activities conducted at the Salem Generating Station Unit No. 1 during the seventeenth refueling outage. This report is submitted in accordance Article IWA-6000 of Section Xi of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, 1998 Edition, 2000 Addenda.

The enclosures to this letter are as follows:

Enclosure 1 Salem Unit 1, 1R1 7 Final Outage Report.

Enclosure 2 Salem Unit 1, ISI Examination Plan and Results Enclosure 3 Salem Unit 1, Reactor Coolant Pump (RCP) Flywheel Inspection Plan and Results Enclosure 4 Salem Unit 1, IWL Examination Plan and Results Enclosure 5 Salem Unit 1, Owners Activity Report Should you have any questions regarding this submittal, please contact Justin Wearne at (856) 339-5081.

Sincerely, 1

Thomas P. Joys Site Vice President - Salem Enclosures (5) A04 7 95-2168 REV. 7/99

LR-N06-0023 :2 Document Control Desk C Mr. S. Collins, Administrator - Region I LU. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. S. Bailey, Project Manager - Salem U.S. Nuclear Regulatory Commission Mail Stop 08B1 Washington, DC 20555-0001 USNRC Senior Resident Inspector - Salem (X24)

Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering P. O. Box 415 Trenton, NJ 08625 Mr. Milton Washington Chief Inspector NJ Department of Labor Division of Public Safety, Occupational Safety and Health Bureau of Boiler and Pressure Vessel Compliance P. O. Box 396 101 South Broad Street Trenton, NJ 08625-0392

LR-N06-0023 Enclosure 1 Salem Unit 1, I RI7 Final Outage Report

SALEM UNIT I INSERVICE INSPECTION PROGRAM FINAL OUTAGE REPORT 3rd INTERVAL / 2nd PERIOD /Ist OUTAGE REFUELING OUTAGE 1R17 Fall 2005 FINAL REPORT 1

ABSTRACT This report represents an accumulation of information pertaining to the IS In-Services activities conducted during Salem Unit 1 Refueling Outage 1RI 7.

PSEG Nuclear LLC (PSEG), Framatome - ANP (FTI), Magnaflux Quality Services (MQS),

and Wesdyne, personnel performed an inservice examination (ISI) of selected Class 1, Class 2, Class 3, and CLASS MC, components PSEG Salem Generating Station, Unit 1 (Salem 1), during October 11, 2005 - November 6, 2005 (25 days). These examinations constituted the Seventeenth (2nd Period, 1st Outage) refueling outage at Salem Unit 1.

This Final Report covers the time period (approximately 18 months) between breaker closures after I RI 6 through breaker closure after 1RI 7.

PSEG Nuclear submitted documentation to the NRC and updated the Salem Unit 1 Code Edition from the 1995 Edition, 1996 Addenda to the 1998 Edition, 2000 Addenda in order to align Salem Units 1 and 2 and Hope Creek; to the same Edition and Addenda of the Code.

NDE exams were performed in accordance with the ASME Section Xl 1998 Edition 2000 Addenda. Appendix VIII exams were performed to the 1998 Edition 2000 Addenda as amended by Final Rule and 1998 Edition, IIWE / IWL 1998 Addenda of ASME Section Xl and the Salem Inservice Inspection Program Long Term Plan.

ISI was performed utilizing visual (VT), magnetic particle (MT), liquid penetrant (PT),

manual ultrasonic (UT), and radiography (RT) nondestructive examination techniques.

This report also contains augmented examinations required by the Salem Technical Specifications, and Regulatory Commitments, Circulars and Bulletins issued by the United States Nuclear Regulatory Commission.

1.

SUMMARY

REPORT During the Fall 2005 refueling outage (1R1 7), PSEG, MQS, FTI, and Wesdyne personnel performed nondestructive examinations (NDE) of selected Salem Generating Station, Unit 1 Class '1,Class 2, Class 3 and Class MC components. These examinations constituted the Seventeenth (2r'd Period,1 st Outage) In-service Inspection (ISI) during the Third Ten Year Inspection Interval, of commercial operation.

A. Applicable Documents The ISI was conducted in accordance with the following documents:

Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code, "Rules for Inservice Inspection of Nuclear Power Plant Components", 1998 Edition 2000 addenda, and IWE / IWL to the 1998 Edition, 1998 addenda.

  • 10-Year Inservice Inspection Program for Salem Nuclear Generating Station Unit 1 (Third Interval) Initial Issue.
  • PSEG's Salem Nuclear Generating Station Unit 1, Outage ISI Examination Plan (Rev. 0), Third Interval, Second Period, First Outage (10/11/2005 through 11/06/2005).
  • ASME Section Xl Appendix Vil examinations were performed in accordance with ASME Section Xl, Div. 1,1998 Edition, and 2000 Addenda Appendix Vil, as amended by the Federal Register Notice 67FR60520 through 67FR60542 dated September 26, 2002.

B. ISI Section XI examinations performed.

Framatome - ANP (FTI) under the direction of PSEG Nuclear's ISI Group, conducted zero mechanized ultrasonic, 48 manual ultrasonic, 6 liquid penetrant, II magnetic particle examinations.

During 1R1 7, PSEG Nuclear implemented Risk Informed Inservice Inspection (RI-ISI) of Nuclear Class 1 and 2 Piping Welds, formerly known as ASME Section Xl Exam Category B-F, B-J, C-F-1 and C-F-2. The bases of the Salem Unit I RI-ISI Program are documented in the Salem Nuclear Generating Station - Final Report -

Risk Informed Inservice Inspection Application (VTD-326046).

Examinations were performed of the following components and systems.

Class I Vessels

  • Pressurizer Piping
  • Safety Injection
  • Chemical Volume Control Class 2 Vessels
  • Residual Heat Exchangers Piping
  • Boiler Feed
  • Chemical Volume Control
  • Auxiliary Feed
  • Sampling Class 3 Piping
  • Component Cooling C. ISI Section Xi Visual examinations on valves and bolting PSEG's ISI Group conducted zero Class 1 Exam Categories B-G-2 bolting exams or B-M-2 valve internal exams during this outage.

D. ISI Section Xl Visual examination of components supports PSEG conducted one hundred and twenty-five (125) Class 1, 2 & 3 component support visual VT-3 examinations, ISI Section XI examinations were conducted on the following systems:

Auxiliary Feed Residual Heat Removal Chemical Volume Main Steam Component Cooling Safety Injection Containment Spray Service Water Reactor Coolant The following components were observed possessing indications that required further evaluation.

Sum# Component I.D. Description Remarks 505560 1A-11RHRH-006 HANGER Spring Can Setting High 505615_________

1A-11______ RHNotification 20256926 Generated 505615 1A-11RHRH-016 HANGER Spring Can Setting High 505625 1A-1ANER Notification 20256926 Generated 505620 1A-11 RHRH-017

_____________________Notification HANGER Spring Can 20256926 Setting High Generated 505625 1A-11RHRH-018 HANGER Spring Can Setting High Notification 20256926 Generated 505630 1A-1 I RHRH-020 HANGER Spring Can Setting High

._ Notification 20256926 Generated 505685 1A-12RHRH-014 HANGER Spring Can Setting High 505920 1A- HAGER Notification 20256926 Generated 505695 1A-12RHRH-015 50569 IA-2RHR-015Notification HANGER Spring Can 20256926 Setting High Generated 505695 1A-12RHRH-017 HANGER Spring Can Setting High Notification 20256926 Generated 505920 1A-12RHRH-024 HANGER Sprdng Can Setting High Notification 20256926 Generated 505955 1A-12RHRH-026 HANGER Spring Can Setting High

____ ___ ____ ___ ___ ____ ___Notification 20256926 Generated 505960 1A-11RHRH-004 HANGER Spring Can Setting High

______________Notification 20256926 Generated HEAT Concrete Building Structure 51465 1-CCE5 EXCHANGER Pedestal Cracked Notification

_________ __________ SUPPORT 20257792 Generated

There were zero unacceptable conditions observed during the conduct of other component supports visual examinations.

E. RCP Flywheel Examination per USNRC Regulatory Guide 1.14 Framatome-ANP completed required ultrasonic and surface examinations of # 12 reactor coolant pump flywheel (Serial # 2S75P790) in accordance with station technical specification requirements.

There were zero unacceptable indications identified F. ISI Section Xi System Leakage Examinations PSEG's ISI Group conducted thirty-four (34) System Pressure Tests during a System Leakage or on Nuclear Class 1, 2 and 3, in accordance with ASME Section Xl.

A system leakage exam was performned in accordance with ASME Section Xl on all Class 1 Systems. The system leakage test was performed with the Reactor Coolant System in Mode 3 (normal operating temperature and pressure) with the insulation installed. No pressure boundary leakage was detected.

Notifications were initiated to correct minor mechanical leakage that was not corrected during the system walkdowns, but was subsequently corrected.

Class 2 and 3 System Pressure Tests were conducted on the following systems:

Chemical Volume & Control Residual Heat Removal Component Cooling Safety Injection Containment Spray Sampling Demineralized Water Service Water Reactor Coolant Station Air There were zero unacceptable indications identified.

G. Augmented Volumetric Examinations of High Energy Piping Welds per Risk Informed Break Exclusion Region (RI-BER) Branch Technical Position MEB 3-1 PSEG Nuclear implemented Risk Informed Break Exclusion Region (RI-BER) of Nuclear Class 1 and 2 Piping Welds, formerly known as MEB-3-1 Program. The bases of the Salem Unit 1 RI-BER Program are documented in the Salem Nuclear

Generating Station - Final Report -- Risk Informed Inservice Inspection Application (VTD-326046).

There was one (1)weld examined, during this outage to comply with the Risk Informed Break Exclusion Region (IRI-BER).

l Sum# l Component LD l Description l 230600 32-MS-2121-4 Elbow to Pipe There were no unacceptable indications identified.

H. Augmented System Leakage tests per NUREG 0578 "TMI Lessons Learned" PSEG's ISI Group conducted twenty-eight (28) system leakage tests in accordance with NUREG 0578 on the following systems:

Chemical Volume & Control Residual Heat Removal Containment Spray Safety Injection Liquid Radwaste Sampling Waste Liquid Waste Gas There were zero unacceptable indications identified.

I. Augmented Bolted Connection Exams per ISI Code Case N-533-1 PSEG's ISI Group conducted sixty-1:hree (63) Class 1 bolted connection VT-2's in accordance with the ISI Long Term Plan Program Code Case N-533-1.

There were zero unacceptable indications identified.

J. Preservice Examinations on Various Bolting Material Replacements There was one (1) pre-service examinations of bolting performed during this outage.

l Sum# l Component L.D l Description l 032850 4-PS-1 131-10QB TFlange Bolting There were no unacceptable indications identified.

K. Pre-Service Examination Other than Bolting There were seven (7) pre-service examinations other than bolting performed this outage.

Sum# Component LD Description 032810 4-PS-I 131 -22A l Pipe to Tee 032820 4-PS-1I 31 -22B Tee to Pipe 032830 4-PS-11231-22C Tee to Valve 032840 4-PS-Il 31-22D Valve to Flange 006051 CRD Housing Surface CRD Housing 006071 1-CRDUH New RPV head 006072 RPV New Upper Head New RPV head There were zero unacceptable indications identified.

L. Erosion / Corrosion UT Thickness Program In response to NRC Bulletin 87-01 and PSEG Engineering Directive MEC 1071, one hundred and six (106) components were scheduled for examination.

The following components were replaced in 1RI 7 due to the results of the flow accelerated corrosion exams from the previous outage (1R16):

System Descrilption FAC l.D. Included in Replacement Heater Drain 30' of 6" piping Al 2, Al 3, A79 S stem__ _ _ _ _ _ _ _ _

Heater Drain Al 5, Al 6, A76, A77, System 105' of 6" piping A81, Al 02 Gland Seal 20' of 5" pipe B10 Steam _ _ _ _ _ _ _ _ _ _ _ _

MSR Drain 40' of 4" pipe C61, C92, C-99 System System 20' of 3n pipe C87 Cold Reheat Weld Build up 62" x 54" Tee E12 supply Cold Reheat Weld Build uip 54"x X42" E14 Supply Reducer SGF 12" x 14" Expander and 3" pipe N14 SGF 3' of 8" pipe N46

Feedwater Feedwater 5' of 113" pipe N56 SGe F (2) 14" elbows N59, N63 There were two (2) contingency planned replacements that materialized due examination results from 1R1 7. They were as follows:

System Description FAC l.D. Included in Replacement Heater Vents 20' of 3" piping H13, H15 System __________________________

System Description FAC l.D. Included in Replacement SGF 12" x 14" Expander N27 Feedwater and 3" pipe I Twenty (20) of the components examined were evaluated due to minimum measured thickness readings below 87.5% of nominal wall. All were evaluated as acceptable for continued operation. Also planned and executed as a result of the 1R1 6 exam results was an exiemal weld build-up of the 16A Feedwater Heater Shell including D74.

There were no other deficiencies identified.

M. Technical Specification 4.7.9 (c) Functional Testing of Selected Hydraulic and Miechanical Snubbers.

Hydraulic Snubbers (First Test Sample)

One MSIV 200 Kip Paul Monroe Large Bore Hydraulic snubber was tested in accordance with the station 10% sample plan by Wyle Laboratories Automated Products Incoporated (API) in-place snubber test machine. This snubber was replaced due to end of seal life. The old snubber was tested and found satisfactory. No further sampling was required.

Two Lisega small hydraulic snubbers were also tested in accordance with the station 10% sample plan using the Wyle Laboratories Model 150 Snubber Test Machine.

Tests completed were found satisfactory there was no sample expansion required in accordance with Technical Specifications for either test sample population.

Mechanical Snubbers (First Test Sample)

Mechanical snubbers were tested in accordance with Salem Technical Specification (TS) 4.7.9(c), 10% sample plan on the Wyle Laboratories Model 150 Snubber Test Machine as follows:

1- Mechanical large (PSA-35) 10- Mechanical medium (PSA-1, 3 and 10's) 1- Mechanical small (PSA-I/4 and 1/2's) 1- Mechanical medium (PS;A-1) non-TS.

All snubbers were tested and found within acceptable standards.

N. ISI Section Xi Visual Examination for Containment Integrity.

There were zero IWE visual examinations performed and one hundred and eighty-six (186) IWL visual examinations performed this outage.

There were no unacceptable indications identified.

0. Reactor Coolant Pump Shaft Inspection.

Due to industry issues concerning Reactor Coolant Pump shaft cracking, there was one (1) augmented ultrasonic examination performed on the Reactor Coolant Pump Shaft #12.

There were no unacceptable indications identified.

P. Reactor Pressure Vessel Low Head Inspection.

PSEG Nuclear personnel performed bare metal visual examinations of the bottom mounted instrument penetrations located on the reactor pressure vessel lower head.

There were zero unacceptable indications identified.

Q. Salem Unit 1 Reactor Pressure Vessel Head Replacement.

Framatome - ANP during the 1R1 7 Re-Fueling Outage, replaced the Salem Unit 1 Reactor Pressure Vessel head. Framatome examined the control rod drive mechanism (CRDM) penetrations. The examination results can be found in the Reactor Vessel Head Penetration NDE Inspection Final Report # 51 -5070590-01.

No degradation or crack-like indications were identified in the peripheral 24 DM welds, 53 CRDM penetrations or in the reactor vessel and level indication

system (RVLIS) and vent line penetrations. There were numerous minor weld fabrication indications detected near the J-groove fusion line on the CRDM penetrations with the ultrasonic method. Most of the indications recorded lie in the weld material and not the nozzle wall. The RVLIS and vent line had indications located on the OD surface that, with high probability, originated during the installation process.

The ET examination revealed 7 indications in 6 of the 53 CRDM nozzles. Of these 7 indications, 3 were l.D. Anomalies (IDA) and 4 were Permeability Variations (PVN). None of the IDA's were flaw-like, although the IDA in Nozzle 58 could be detected on the prime frequency of the 0.80 differential coil. In addition, the IDA's had some consistency in location ranging from BTM +2.68 to BTM +3.41. Previous inspections of other reactor vessel head penetrations have shown both ID crazing and scratching at the J-groove weld region, but neither condition is evident for the current, examination. The examination performed on the vent line and RVLIS nozzles revealed no defects or other signals of interest.

No PT indications were detected in the examination of 24 peripheral stainless steel (F304) adaptor to Inconel 690 (A690) penetration tube bimetallic welds (e.g., DM weld).

R. Visual Examination on Alloy 600 welds.

During 1R1 7, PSEG Nuclear personnel performed bare metal visual examinations on the following components:

Sum# Component I.D.

006081 Flux Thimbles welds 1-58 047250 #14 Hot leg Thermal Welds 048275 #13 Hot leg Thermal Welds 050850 #12 Hot leg Thermal Welds 052625 #11 Hot leg Thermal Welds 052626 #1 1-STG Center Bowl Drain Plug 054350 #14 Cold leg Thermal Welds 054351 #14-STG Center Bowl Drain Plug 055750 #13 Cold leg Thermal Welds 055751 #13-STG Center Bowl Drain Plug 057350 #12 Cold leg Thermal Welds 057351 #12-STG Center Bowl Drain Plug 058650 #11 Cold leg Thermal Welds There were no unacceptable indications identified.

S. Visual Examinations on Accumulator Instrumentation Nozzles.

During 1R17, PSEG Nuclear personnel performed bare metal visual examinations on the following components due to industry events at Surry Nuclear Station and stress corrosion cracking concerns:

Sum# Component I.D.

197250 1SJE6 #11 Accumulator Instrumentation Nozzle Penetrations 198150 1SJE7 #12 Accumulator Instrumentation Nozzle Penetrations 198950 1SJE8 #13 Accumulator Instrumentation Nozzle Penetrations 199750 1SJE9 #14 Accumulator Instrumentation Nozzle 7 Penetrations There were zero unacceptable indications identified.

T. Vsual Examination on Pressurizer Instrumentation Nozzles.

During 1R1 7, PSEG Nuclear personnel performed bare metal visual examinations on eight (8) pressurizer instrumentation nozzle penetrations due to industry events at Crystal River Nuclear Station.

There were zero unacceptable indications identified.

U. Vsual Examination on RPV Hot and Cold Leg Nozzles.

During 1RI 7 PSEG Nuclear personnel performed bare metal visual examinations on eight (8) RPV Hot and Cold Leg Nozzles.

There were zero unacceptable indications identified.

LR-hNO6-0023 Enclosure 2 Salem Unit 1, ISI Examination Plan and Results

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 1 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1

-AdIIIIIIdLn rIIU HUHIIIVU Ur VI mIId LUII IV '.I I ICU 1-RPV-STUDS 19-36 4

CLOSURE STUDS 4

UT-00 4 Accept 4 Examiner. None 005200 Examination Performed by Framatome Certified 1-RPV-STUDS 19-36 CLOSURE STUDS UT-0 0 Accept Examiner. None

_ _ A__ -.- ...... ...

Examination Performed by Framatome Certified 1-RPV-STUDS 19-36 0 CLOSURE STUDS UT-0 Accept Examiner. None

. . . . - A_ _

Examination Performed by PSEG Certified Level II 005310 1-RPV-NUTS 19-36 CLOSURE NUTS VT-1 ^.

Accept Examiner. None Go __ __

Examination Performed by PSEG ertified Level II 1

005400 1-RPV-WASHERS 19-36 CLOSURE WASHERS VT-1 Accept Examiner. None t + + 4 4 RPVCH Replacement completed. PT examination Examination Performed by Framatome Certified performed for the purposes of preservice 006051 CRD Housing Surface CRD HOUSING WELD EXAMS PT Accept Examiner. inspection.

1 4 4 4 Examination Performed by Framatome Certified RPVCH Replacement completed. UT examination 006051 CRD Housing Surface CRD HOUSING WELD EXAMS UT Accept Examiner. performed for the purposes of baseline inspection.

  • 4 4 4 VESSEL CLOSURE HEAD TO Examination Performed by Framatome Certified RPVCH Replacement completed. UT examination 006071 1-CRDUH CRDM - J GROOVE M-UT Accept Examiner. performed for the purposes of baseline inspection.

I + 4 4 4 CRDM TO VESSEL Examination Performed by PSEG Certified Level IlIl RPVCH Replacement completed. VT examination 006072 jRPV New Upper Head PENETRATION WELD VT Accept Examiner. performed for the purposes of baseline inspection.

-- + ______ -

PENETRATION WELD ON Examination Performed by PSEG Certified Level II 006080 IRPV LOWER HEAD LOWER VESSEL HEAD VT-2 Accept Examiner. None

-4 + I 4 IFlux Flux Thimble Tubing Dissimilar Examination Performed by PSEG Certified Level II 006081 Thimble Welds 1-58 Metal Welds VT-2 _. _

Accept Examiner. None b . __

Examination Performed by Framatome Certified 1-PZR-2 LONGITUDINAL WELD SHELL A UT-60' Accept Examiner. None

.......... _ .. _ = ^ .

006100 Examination Performed by Framatome Certified 1-PZR-2 LONGITUDINAL WELD SHELL A UT-45' . Accept Examiner. . None Examination Performed by Framatome Certified 1-PZR-2 LONGITUDINAL WELD SHELL A UT-0° Accept Examiner. None Examination Performed by Framatome Certified 6-PRN-1103-IRS RELIEF NOZZLE UT-45° Accept Examiner. None 4 4 4 - 4 Examination Performed by Framatome Certified 6-PRN-1 103-IRS RELIEF NOZZLE UT-45 Accept Examiner. None 007100 I_ I Examination Performed by Framatome Certified 6-PRN-1 103-IRS RELIEF NOZZLE UT-70' Accept Examiner. None Examination Performed by Framatome Certified 6-PRN-1 103-IRS RELIEF NOZZLE UT-60' Accept Examiner. None 1 4 4 4 - +

Examination Performed by Framatome Certified 6-PRN-1 104-IRS RELIEF NOZZLE UT-70' Accept Examiner. None 4 4 ____ - 4 007200 Examination Performed by Frarratome Certified 6-PRN-1 104-IRS RELIEF NOZZLE UT-60' Arrept Examiner None

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 2 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examination Performed by Framatome Certified 6-PRN-1 104-IRS RELIEF NOZZLE UT-45' Accept Examiner. None Examination Performed by Framatome Certified 6-PRN-1 104-IRS RELIEF NOZZLE UT-45' Accept Examiner. None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 3 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 amatome 6-PRN-1105-IRS RELIEF NOZZLE UT-60' Accept Examiner. None 4 I - ___________________________ ________________

Examination Performed by Framatome Certified 6-PRN-1 105-IRS RELIEF NOZZLE UT145° Accept Examiner. None 007300 4 1 Examination Performed by Framatome Certified 6-PRN-1 105-IRS RELIEF NOZZLE _ .

UT-45 __

Accept Examiner. None

.............. .. .... .. S ............... __.

Examination Performed by Framatome Certified 4

6-PRN-1105-IRS 4

RELIEF NOZZLE 1

UT-700° 1 Accept Examiner. None Examination Performed by Framatome Certified 007700 1-PZR-IVS LWR HEAD TO SUPPORT SKIRT IUT-45' Accept Examiner. None Examination Performed by PSEG Certified Level II 007820 PZR BOLTING-MANWAY MANWAY BOLTING VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 007825 PZR Instr Penetrations Instrument Nozzles VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 008790 11-STG-OMB STUDS-OUTLET MANWAY VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 008795 11-STG-IMB STUDS-INLET MANWAY VT-2 Acept Examiner. None xamination Performed by PSEG Certified Level II 0090V i2- STG-CMB0 STUDS-OUTLET MV1ANAY v-2 Acopt Edz iele. NunM _

Examination Performed by PSEG Certified Level II 009675 12-STG-IMB STUDS-INLET MANWAY VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 010550 13-STG-OMB STUDS-OUTLET MANWAY VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 010575 13-STG-IMB STUDS-INLET MANWAY VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 011450 14-STG-OMB STUDS-OUTLET MANWAY VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 011475 14-STG-IMB STUDS-INLET MANWAY VT-2 Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 143-4 ELBOW TO PIPE UT-00 Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1143-4 ELBOW TO PIPE UT-45' Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 143-5 PIPE TO PIPE UT-70' Accept Examiner. None Examination Performed by Framatome Certified 012600 3-CV-1 143-5 jPIPE TO PIPE JUTA5 JAccept I Examiner. None Examination Performed by Framatome Certified 3-CV-1 143-5 J.

PIPE TO PIPE

_________________________ lUT-0° lAcce[pt Examiner.

P None

.i I ________

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 4 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 IExaminauon Performeu Dy iatome 3-CV-1 143-6 PIPE TO PIPE UT-70 IAccept l Examiner. None 012700 1 Examination Performe by Frmato Certfied 3-CV-1 143-6 PIPE TO PIPE UT-45_ Accept Examiner. None A_,

lExamination Perforrmed by Framatome Certified 3-CV-1 143-7 PIPE TO ELBOW UT-45' Accept Examiner. None 4

012800 Examination Performed by Framatome Certified 3-CV-1 143-7 PIPE TO ELBOW UT-0' Accept Examiner. None

+

Examination Performed by Framatome Certified 3-CV-1 143-7 PIPE TO ELBOW UT Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 143-8 ELBOW TO PIPE UT-70' Accept Examiner. None Examnto erfome b'y Framatome Certified --

012900 3-CV-1 143-8 ELBOW TO PIPE UT-00 Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 143-8 ELBOW TO PIPE UT-45 Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 143 PIPE TO ELBOW _

UT-45' Accept Examiner. None 013000 Ex-amin~atio-nPerfo~rmed-b~y Franmatome Certified 3- C'v' 43- A PIPE TO aELBOW vAF. Accept None_... ..

Examination Performed by Framatome Certified 3-CV-1 143-9 PIPE TO ELBOW UT-0' Accept Examiner. None

-- - Examination Performed by Framatome Certified 3-CV-1 141-6 PIPE TO ELBOW UT-70' Accept Examiner. None Examination Performed by Framatome Certified 015900 3-CV-1 141-6 PIPE TO ELBOW UIT-45' Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 141-6 PIPE TO ELBOW UT-0° Examiner. None Accept Examination Performed by Framatome Certified 3-CV-1 141-7 ELBOW TO PIPE UT-70' Examiner. None 016000 ... . i -

Accept Examination Performed by Framatome Certified 3-CV-1 141-7 ELBOW TO PIPE UT-45' Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 141-8 PIPE TO ELBOW UT-a0 Accept Examiner. None

...... 7 016100 Examination Performed by Framatome Certified 3-CV-1 141-8 PIPE TO ELBOW UT-70' Accept Examiner. None Examination Performed by Framatome Certified 3-CV-1 141-8 PIPE TO ELBOW UT-45' Examiner. None

__B UTTikess and Cotusotained tosuppr 22200 16-PR-1 105-1 NOZZLE TO SAFE-END T&C Accept Examiner. potential future DM weld inspections.

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 5 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examination Pi d by Framatome Certified 6-PR-1105-4 ELBOW TO PIPE UT-59' Accept Examiner. lNone 4 1 _____ - + 4 022500 Examination Performed by Framatome Certified 6-PR-1 105-4 ELBOW TO PIPE UT-45' Accept Examiner. None


...... Examination Performed by Framatome Certified 6-PR-1105-4 ELBOW TO PIPE UT-69' Accept Examiner. None Examination Performed by Framatome Certified 6-PR-I 105-5 PIPE TO ELBOW UT-45' Accept Examiner. None 022600 Examination Performed by Framatome Certified 6-PR-1 105-5 PIPE TO ELBOW UT-69' Accept Examiner. None Examination Performed by Framatome Certified 6-PR-1 105-5 PIPE TO ELBOW UT-59° Accept Examiner. None 6-PR-1 105-6 ELBOW TO ELBOW j Examination Performed by Framatome Certified UT-59° Accept Examiner. None 022700Examination Performed by Fraatome Certified 6-PR- 105-6 ELBOW TO ELBOW UT45° Accept Examiner. Nn__

Examination Performed by Framatome Certified 6-PR-1i105-6 ELBOW TO ELBOW 1UT-69° Accept Examiner. None Examination Performed by PSEG Certified Level li 023300 6-PR- i i05-HI FB iPR5 FLANGEi~ cOLT ING .U-2 Auuepi NIiie Examination Performed by Framatome Certified 023400 016-PR-1104-1

_e NOZZLE TOT SAFE-END T&C Accpt Examiner. - None Examination Performed by PSEG Certified Level II 024500 6-PR-1 104-1 1FB 1PR4 FLANGE BOLTING Accept Examiner. None 1- t I + .s Examination Performed by Framatome Certified UT Thickness and Contours obtained to support 024600 6-PR-1 103-1 NOZZLE TO SAFE-END T&C Accept Examiner. potential future DM weld inspections.

e Examination Performed by PSEG Certified Level II 025800 4 6-PR-1 103-1 2FB 1PR3 FLANGE BOLTING VT-2 Accept Examiner. None

_ _ _ ,. _ .. ,, ,,,,,,,, ,,,, .................. ........._..u Examination Performed by Framatome Certified UT Thickness and Contours obtained to support 025900 4-PR-1100-1 NOZZLE TO SAFE-END T&C lAccept Examiner. potential future DM weld inspections.

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 6 of 24 12/07/2005 RFO #17 ISI Examination Results Revision I 14-PS-1 131-2 NOZZLE TO SAFE-END UT-450 jAccept Examiner. None Examination Performed by Framatome Certified 14-PS-1 131-2 NOZZLE TO SAFE-END UT-45 VAccept Examiner. None Examination Performed by Frarnatome Certified 14-PS-1131-2 NOZZLE TO SAFE-END UT-60' Accept Examiner. Added to outage as pre-service exam Examination Performed by Framatome Certified 029700 14-PS- 131-2 NOZZLE TO SAFE-END UT-0° Accept Examiner. None Examination Performed by Framatome Certified 14-PS-1131-2 NOZZLE TO SAFE-END UT-600 Accept Examiner. None Examination Performed by Framatome Certified 14-PS-1131-2 NOZZLE TO SAFE-END UT-35' Accept Examiner. None___ _-__

Examination Performed by Framatome Certified 14-PS-1131-2 NOZZLE TO SAFE-END UT-45' Accept Examiner. None Examination Performed by Framatome Certified 4-PS-1 131-22A PIPE TO TEE UT-0° Accept Examiner. Added to outage as pre-service exam Examination Performed by Framatome Certifled 4-PS-1 131-22A PIPE TO TEE UT-45 0 Accept Examiner. Added to outage as pre-service exam 032810 I Examination Performed bFrmtme Certified Tn_rr 4-P-C 3422f'A DPIPE I - UT c.4cet aminatio P m ed y Ci m Addmdi u ouuage as pre-service exam 4-4-PS-I 131-22A PIPE TO TEE RT Accept Examination Performed by MQS Certified Examiner. Added to outage as pre-service exam

....................... s a~~__ A__

a_ W 4-PS-1 131-22B TEE TO PIPE UT-01 Accept Examiner. _____ Added to outage as pre-service exam Examination Performed by Framatome Certified 4-PS-I 131-22B TEE TO PIPE UT-45' Accept Examiner. Added to outage as pre-service exam Examination Performed by Framatome Certified 032820 4-PS-1131-22B TEE TO PIPE UT-60 0 Accept Examiner. Added to outage as pre-service exam N~otification #202581866wa generatedonrjce 4-PS-1 131-22B

+

TEE TO PIPE RT Accept Examination Performed by MQS Certified Examiner. weld X-Ray. _

4-PS-1i131-22B TEE TO PIPE RT Accept Examination Performed by MQS Certified Examiner. Added to outage as pre-service exam 032830 4-PS-1131-22C TEE TO VALVE RT Accept Examination Performed by MQS Certified Examiner. Added to outage as pre-service exam 032840 4-PS-1 131-22D VALVE TO FLANGE RT Accept Examination Performed by MQS Certified Examiner. Added to outage as pre-service exam xamination Performed by PSEG Certified Level xai 032850 14-PS-1131-1OFB FLANGE BOLTING VT-2 Accept Examiner. Added to outage as pre-service exam

_e xamination Performed by Framatome Certified ,UT Thickness and Contours obtained to support 1

033501 4-PS-1 131-29 NOZZLE TO SAFE-END T&C Accept Examiner. potential future DM weld inspections.

4- 1

-............ Examination Performed by PSEG Certified LevlI 047250 114 HOT LEG Thermal Welds Thermal Well Welds VT-2 Examiner. None Examination Performed by PSEG Cered L i 047302 129-RC-1140-1-BMV 0NOZZLE TO SAFE-END IYTv Arnpnt I Fy2minpr

-U,"7777 ___ ...........

INone A = ... .......

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 7 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 048275 13 HOT LEG Thermal Welds Thermal Welds VT-2 Accept 4-I Examiner. None 4- 4 Examination Performed by PSEG Certified Level II 048302 29-RC-1130-1-BMV NOZZLE TO SAFE-END VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 050850 12 HOT LEG Thermal Welds Thermal Welds VT-2 Accept Examiner. None 4 4 t 4 Examination Performed by PSEG Certified Level II 050902 29-RC-1 120-1-BMV NOZZLE TO SAFE-END VT-2 Accept Examiner. None

+ 4 + 4 Examination Performed by PSEG Certified Level II 052625 11 HOT LEG Thermal Welds Thermal Welds VT-2 Accept Examiner. None 4 4 4 _____ - 4 Steam Generator #11 Hot/Cold Examination Performed by PSEG Certified Level II 052626 i11-STG ChannelL Head Channel Head VT-2 Accept Examiner. None 4 L _ _ _ -

Examination Performed by PSEG Certified Level II 052652 29-RC-1 11 0-1-BMV NOZZLE TO SAFE-END VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 054350 14 COLD LEG Thermal Welds 1Thermal Welds VT-2 Accept Examiner. None Steam Generator #14 Hot/Cold Examination Performed by PSEG Certified Level II 054351 14-STG Channel Head Channel Head VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 055702 27.5-RC-i 14UO-5BMV NOZZLL TO SAF4E-END VT-2 Accept Examiner. None

+ 4- 4 1 Examination Performed by PSEG Certified Level 11 055750 13 COLD LEG Thermal Welds Thermal Welds VT-2 Accept Examiner. None Steam Generator #13 HotCold Examination Performed by PSEG Certified Level II 055751 13-STG Channel Head Channel Head VT-2 Accept Examiner. None

_ __ _Examination Performed by PSEG Certified Level II 057302 27.5-RC-1130-5-BMV NOZZLE TO SAFE-END VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 057350 112 COLD LEG Thermal Welds Thermal Welds VT-2 Accept Examiner. None Steam Generator #12 Hot/Cold Examination Performed by PSEG Certified Level II 057351 112-STG Channel Head Channel Head VT-2 Accept Examiner. None 1 -4 4 4 -I-Examination Performed by PSEG Certified Level II 058602 127.5-RC-1 120-5-BMV NOZZLE TO SAFE-END VT-2 Accept Examiner. None 4 4 _4 .... 4 Examination Performed by PSEG Certified Level II 058650 11 COLD LEG Thermal Welds 1Thermal Welds _ .................

VT-2 Accept . ..

Examiner. _

None Examination Performed by PSEG Certified Level II 060002 27.5-RC-1 I 10-5-BNMV NOZZLE TO SAFE-END XIT-2 Accept Examiner. None Examination Performed by Framatome Certified 100300 10-SJ-1 121-8PS PENETRATION TO PIPE PT Accept Examiner. None Examination Performed by Framatome Certified 105500 b-SJ-1162-10 M PIPE TO ELBOW I IUT45 Accept Examiner. None Examination Performed by Framatome Certifid 105600 4.8-SJ-1 162-11 _

ELBOW TO PIPE __ UT-45'_ Accept - _ Examiner. ,

4_

... None Examination Performed by Framatome Certified 105700 _r 18-SI-11162-42 IPIPE

.....I TO ELBOW


IJUIT-45' jAccept IExa-miner. ,'None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 8 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 8-SJ-1 162-13 IELBOW TO PIPE UT-45' Accept Examiner. None 105800 Examination Prormed b rmtm etfe 8-SJ-1 162-13 ELBOW 1FO PIPE UT-60° Accept Examiner. None Examination Performed by Framatome Certified 125600 4-SJ-1 194-8 PIPE TO PIPE PT Accept Examiner. None Examnination Performed by Framatome Certified 125700 4-SJ-1194-9 PIPE TO ELBOW PT Accept Examiner. None Examination Performed by Framatome Certified 126000 4-SJ-1194-12 ELBOW I ro PIPE PT Accept Examiner. None Examination Performed by PSEG CertifiedLeveII 190800 11-P..P-BOLTS 1-24 RCP PU AP BOLTS VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 191600 12-PMP-BOLTS 1-24 RCP PUhAP BOLTS VT-2 Accept Examiner. None Examination Performed by Wse Certified 192055 #1_2RCP SHAFT, PUMP S IAFT UT Accept Examiner. None Examination Performed by PSEG Certified Level)II 192400 13-PMP-BOLTS 1-24 RCP PUhAP BOLTS VT-2 Accept Examiner. None Accept 1932005 D#12

-B l DdD MIU k IfA nfl m

V I -X. [1117 Examination Examiner.

rfmed byPSEG Certified Level iI None l Accept Examination Performed by PSEG Certified Level II 194000 1CV 77 1Bolting

- -- -I- ,,, -

VT-2 Accept Accept Examiner. None Accept Examination Performed by PSEG Certified Level II 194100 1 CV 78 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 194120 1 CV2 Bolting VT-2 Accept Examiner. None

'Examrin-atio-n Pe~rforme-d by PSEG Certfified Level -Il 194140 1 CV 75 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 194200 1 CV 79 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 194300 1 CV80 Bolting VT-2 Accept Examiner. None Accept ExaminatonPrforedl by PSGCriied t Levell II-194400 1 CV 274 Bolting VT-2 Examiner. None Accept Examination Performed by PSEG Certified Level II 194500 1 CV 275 Bolting VT-2 Examiner. lNone Accept Examination Performed by PSEG Certified Level II None 194600 I CV 277 Bolting VT-2 Examiner. INone Accept Examination Performed by PSEG Certified Level II None 194700 1 PR 1 Bolting VT-2 Examiner. l:None Accept I 194800 1 PR 2 BBolting VT-2 Examiner. lNone Examination Performed by PSEG Certified Level II 194900 1-PR3 oltinn IVT-2 IAcr.nf IF~xanairir .on

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 9 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 r-AdMiicinLIUti reIUrrIImU vy rbtU IWUIInU LXVtI 1 195000 l1 PR 4 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level I1 195100 1 PR5 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 195200 1 PR6 Bolting r-2 Accept_ Examiner. None Examination Performed by PSEG Certified Level il 195300 1 PR7 Bolting V.r1-2 Accept Examiner. None Examination P.rformed by PSEG Certified Level I=

195400 11 Ps 1 Bolting r1-2 Accept Examiner. None V Examination Performed by PSEG Certified Level 11 195500 1 PS 3 Bolting 17-2 Accept Examiner. None Exmination Performed yPE etiidLvlI 195600 1 PS 24 Bolting 'Fr-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 195700 1 PS 25 Bolting r-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 195800 1 PS 28 Bolting r-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 19590nl001PS29 BL:.ng - - Ir-2 AccePt Examiner. Noun e Examination Performed by PSEG Certified Level 11 196000 1 RH 1 Bolting V r-2 Accept None 196100 1 RH2 Bolting V r-2 Accept Examiner. None Examination Performed by PSEG Certfed Level il 196200 1 RH 26 Bolting V r-2 Accept Examiner. None Exmination Performed by PSEG Certified Level 11 196500 1 SJ 135 Bolting V r-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 196900 11 SJ 40 Bolting V T-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 197100 11SJ49 Bolting V r-2 Accept Examiner. None Accept Tr-2 Examination Performed by PSEG Certified Level 11 197200 11 SJ54 Bolting V Accept Examiner. None

  1. 11 Accumulator Instrumentation Examination Performed by PSEG Certified Level 11
197250 1SJE-6 "Nozzle Penetrations Vr-2

= f . ^ .........

Examiner. None Examination Performed by PSEG Certified Level 11 197300 11 SJ 55 Bolting Vr-2 Accept Examiner. None Examination Performed by PSEG Certified Level11 197400 11 SJ 56 Bolting Vr-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 197500 197500 11 SJ 156 11 SJ 156 Bolting Bolting vr-2 VT-2 Accept Accept Examiner. . None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 10 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examinauon rerformed Dy PSrE UerutleG Level 1i 197800 112 SJ 40 Bolting VT-2 Accept Examiner. None

.... . .. ......... .. A.._... . . i- . _ ___

Examination Performed by PSEG Certified Level II 198000 112 SJ 49 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 1

198100 12 SJ 54 Bolting VT-2 Accept Examiner. None

  1. 12 Accumulator Instrumentation Examination Performed by PSEG Certified Level II 198150 11SJE-7 Nozzle Penetrations VT-2 Accept Examiner. None I"

Examination Performed by PSEG Certified Level II 198200 12 SJ 55 Bolting VT-2 Accept Examiner. None 4

  • Examination Performed by PSEG Certified Level II 198300 12 SJ 56 Bolting VT-2 Accept Examiner. None 4 4 - ~

Examination Performed by PSEG Certified Level II 198400 12 SJ 156 Bolting:7- VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 1

198900 13 SJ 54 Bolting VT-2 Accept Examiner. None

  1. 13 Accumulator Instrumentation Examination Performed by PSEG Certified Level II

,lnonr

+

4 OjM_.

4 I MW" 1V r' I M cl~UdUlb viral-2 V -

Accept None Examination Performed by PSEG Certified Level II 199000 13 SJ 55 Bolting VT-2 Accept Examiner. None Examination Performned by PSEG Certified Level II 199100 13 SJ 56 Bolting VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 199200 13 SJ 156 Bolting VT-2 Accept Examiner. None

- 4 '4 Examination Performed by PSEG Certified Level II 199700 14 SJ 54 Bolting VT-2 Accept Examiner. None

+ 4 - 4 _____ - I

  1. 14 Accumulator Instrumentation Examination Performed by PSEG Certified Level II 199750 1SJE-9 Nozzle Penetrations VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 199800 14 SJ 55 Bolting VT-2 Accept Examiner. None

+ I - 4-Examination Performed by PSEG Certified Level iI 199900 14 SJ 56 Bolting- VT-2 Accept Examiner. None 4- 4 Examination Performed by PSEG Certified Level II 200000 14 SJ 156 Bolting VT-2 Accept Examiner. None

'Examination Performed by Framatome Certified 204450 1-BIT-2 OUTLET NOZZLE TO SHELL MT Accept Examiner. None Examination Performed by Framatome Certified 1-BIT-2 OUTLET NOZZLE TO SHELL UT-45' Accept Examiner. None 4 4 4 4 204450 Examination Performed by Framatome Certified 1-BIT-2 OUTLET N077LE TO SHELL UT-60' Acp Examiner. None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 11 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 1-BIT-2 OUTLET NOZZLE TO SHELL JUT-0 jAccept Examiner. None Examination Performed by Framatome Certified 11-RHRHEX-1 LANGE TO SHELL UT-60° Accept Examiner. None

^

205150 Examination Performed by Framatome Certified 11-RHRHEX-1 LANGE TO SHELL UT-70° Accept Examiner. None Examination Performed by Framatome Certified 11-RHRHEX-1 LANGE TO SHELL UT-45° Accept Examiner. None Examination Performed by Framatome Certified 11-RHRHEX-OUT ;HELL TO NOZZLE UT45'0 Accept Examiner. None xamination Perormed by Framatome Certified 11-RHRHEX-OUT ;HELL TO NOZZLE PT Accept_ Examiner. None 205168 Examination Performed by Framatome Certified 11-RHRHEX-OUT HELL TO NOZZLE UT-60° Accept Examiner. None Examination Performed by Framatome Certified 11-RHRHEX-OUT SHELL TO NOZZLE UT-70° Accept Examiner. None Examination Performed by Framatome Certified 223200 34-MS-2131-lPL-1 'IPE LUG MT Accept Examiner. None Examination Performed by Framatome Certified 3A-MS-91 31 -1PiL-9 P! IIPEI

. IAdaII III 1 W.1 None Examination Performed by Framatome Certified l 223400 134-MS-2131-1PL-3 THRU 6 Pl PE LUG MT Accept Examiner. None Examination Performed by Framatome Certified 223800 34-MS-2131-IPL-7THRU 10 PI PE LUG MT Examiner. None Accept__

223800 34-MS-2131-1PL-7THRU 10 Pi PE LUG MT Examination Performed by MQS Certified Examiner. None Accept Ace pt Examination Performed by Framatome Certified 224010 34-MS-2131-lPL-11 P1PE LUG Examiner. None

~Accept Examination Perormed by Framatome Certified 224015 34-MS-2131-1PL-12 P1PE LUG MT Examiner. None

~Accept 224020 34-MS-2131-1PL-3_THRU 16 P1PE LUGM Examination Performed by MQS Certified Examiner. None Accept Examination Performed by Framatome Certified 224020 34-MS-2131-1PL-13THRU 16 PlPE LUG MT Examiner. None Accept Examination Performed byFramatome Certified 224040 34-MS-2131-1PL-17THRU 20 Pl PE LUG MT Examiner- !None 1

Accept Examination Performed by Framatome Certified 1

224060 34-MS-2131-1PL-21 IDIPE LUG MT_ Accept Examiner. None Examination Performed by Framatome Certfied Added to Outage to Replace Sum #228900 due to 229000 32-MS-2131-2PL-1 THRU 12 EA. PIPE LUGS (PA-109) MT Accept Examiner. inaccessiblity Examination Performed by Framatome Certified 230600 32-MS-2121-4 ELBOW TO PIPE UT-45° Examiner. None Examinatilon Performed by Framatome Certified 263318 14-RH-2112-3 PIPE TO ELBOW AIPT

.11

.... I'Accept

.... - 11 1Examinpr.___

111111-1 Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 12 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examination Pertormed by Framatome uertmIed 8-CS-2123-2 PIPE TO ELBOW UT-60' tAccpt Examiner. None 353720 Examination Performed by Framatome Certified 8-CS-2123-2 PIPE TO ELBOW_ UT-70' Accept Examiner. None Examination Performed by Framatome Certified 8-CS-2123-3 ELBOW TO PIPE LIT-70' Accept_ Examiner. None 353740 Examination Performed by Framatome Certified 8-CS-2123-3 ELBOW TO PIPE UT-60' Accept Examiner. None Examination Performed by Framatome Certified 8-CS-21 23-4 PIPE TO ELBOW UT-60' Accept Examiner. None Examination Performed by Framatome Certified 353760 8-CS-21 23-4 PIPE TO ELBOW LIT-70' Accept Examiner. None Examination Performed by Framatome Certfied 8-CS-2123-4 PIPE TO ELBOW UT-01 Accept Examiner. None Examination Performed by Framatome Certified 8-CS-2114-3 ELBOW TO PIPE UT-70' Accept Examiner. None 355440 Examination Performed by Framatome Certified 8-CS-2114-3 ELBOW TO PIPE UIT-60' Accept Examiner. None S

Examination Performed by Framatome Certified a - 1 PIPE TO ELBO'Wv U --60' Accepi Examiner. None 355480 4

8-CS-2114-4 4

PIPE TO ELBOW UT-7 0' Accept Examination Performed by Framatome Certified Examiner.

Examination Performed by Framatome Certified INone 8-CS-2114-5 ELBOW TO PIPE UT-60' Accept Examiner. None 355500 Examination Performed by Framatome Certified 8-CS-2114-5 ELBOW TO PIPE UT-70' Accept Examiner. None Examination Performed by PSEG Certified Level II' 500040 IAFG-212 GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 500330 14AFWHr004 HANGER VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level If 500420 13AFWA-041-IA PIPE TO ANCHOR VT-i- Accept Examiner. None I

Examination Performed by PSEG Certified Level II 500455 1AFG-1 99 GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 500520 12AFWS-033 SUPPORT VT-3 Accept iExaminer. None Examination Performed by PSEG Certified Level II 501215 1A-CCA-028-IA PIPE TO ANCHOR VT-I Accept Examiner. None Examination Performed by PSEG Certified Level II 501220 IA-CCG-027 GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 501245 1A-CCH-022-IA PIPE LUGS Accept Examiner. None Examination Performed by PSEG Certified Level II 501385 I1A-CCG-041-lA 1P PE TO GUI!DE I,%Tr-1 God+ep IExam ner. ,1 N01- e

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 13 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examination Performed by PSEG Certified Level II 501405 II1A-CCG-412A GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 502095 11ACSH150IA IPIPE LUG I Accept I Examiner. None Examination Performed by PSEG Certified Level II 502910 11A-CSS-158 SUPPORT VT-3 Accept Examiner. None

+ I + _

Examination Performed by PSEG Certified Level II 503030 11A-CVCG-512 GUIDE VT-3 Accept Examiner. None

+ + 1 Examination Performed by PSEG Certifi Level II 503195 IlA-CVCS-417 ..

SUPPORT _

VT-3 Accept Examiner. None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 14 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1

-0IA 11ionuuni ..

rVi UJIIOu r. LW I.UIuI LCvCIl~

r u 1 503275 1A-C VCG-495 GUIDE VT-3 Accept None fExamination Performed by PSEG Certified Level II 503305 1A-CVCS-501 SUPPORT 1VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 503340 1P-CVCS-407 SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 503930 1C-CVCS-294 SUPPORT VT-3 Accept Examiner. None

'Examination Performed by PSEG Certified Level II 503955 1C-CVCG-317 GUIDE VT-3 Examiner. None

+)--

IExamination Performed by PSEG Certified Level II 504335 1-MSAS-105 SUPPORT VT-3 Accept Examiner. None

[Examination Performed by PSEG Certified Level II 504360 i-MSAH-101 HANGER VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 504425 1P-MSAG-117 GUIDE VT-3 Accept Examiner. None

{Examination Performed by PSEG Certified Level II 504460 1P-MSAG-1 32 GUIDE Accept Examiner. None Accept Examination Performed by PSEG Certified Level II 504490 1A-MSAS-12C-!A P!PE TO SUPPOP.T VT-3 None Examination re Performed by PSEG Certified Level 504640 1-MSAH-1 10 HANGER ~Accept Examiner. None VT Examination Performed by PSEG Certified Level II 505130 1C-PRG-192 GUIDE .Accept_ Examiner. None

\Vr-3-- a tion Performed by PSEG Certified Level II 505205 1 C-PRH-165 HANGER Accept__ Examiner. None VT-3 Examination Performed by PSEG Certified Level II 505280 1C-PRG-046 GUIDE Accept Examiner. None Examination Performed by PSEG Certified Level II INon 505330 1C-11 RHH-001 HANGER IVT-3 Accept Examiner.

Examination Performed by PSEG Certified Level II INone 505355 1C-11 RHS-006 SUPPORT VTr-3 Accept Examiner. None Examination Performed by PSEG Certified Level IH 505380 1C-13RHH-008 HANGER VTr-3 Accept zAccept Examiner. None Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum4 505625 and 505690 and notification#

505510 11P-11 RHH-009 HANGER VT-3 Accept Examiner. 20256267 and 20256926 4 .

Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505515 1P-11RHH-010 HANGER VTr-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505520 1P-11RHH-011 HANGER VT-3 !Examiner. 20256267 and 20256926

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 15 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examinetion r.rrormea WY ,Ulu IIu LCVI 505525 1P-11 RHG-012 GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level 11 505530 11C-11 RHH-007 HANGER VT-3 Accept Examiner. None 4 + + +

Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505545 1A-12RHRH-036 HANGER VT-3 Accept Examiner. 20256267 and 20256926

- -- M v .f. v ^ He v Mv sZ v - - .. . Mv .w ._-

Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505555 IA-I IRHRH-005 HANGER V1-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505560 1A-11 RHRH-006 HANGER VT-3 Reject Examiner. 20256267 and 20256926

-1 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505565 1A-IIRHRH-007 HANGER VT-3 Accept Examiner. 20256267 and 20256926

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 16 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505580 1A-12RHRH-005 HANGER vr-3 Accept Examiner. 20256267 and 20256926 1-Examination Performed by PSEG Certified Level iI 505590 1A-11RHRH-011 HANGER VT-3 Accept Examiner. None

+

Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505600 1A-11 RHRH-014 HANGER VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505610 1A-11RHRH-010 HANGER VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505615 1A-11RHRH-016 HANGER VIF-3 Reject Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505620 IA-11RHRH-017 HANGER VT Reject Examiner. 20256267 and 20256926 VT-3 examination noted high spring can set Examination Performed by PSEG Certified Level 11 exceding code specifications notifications 505625 iA-1 i RHRH-0 i8 HANGER VT1-3 Reject Examiner. 20256267 and 20256926 generated Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505630 1A-11 RHRH-020 HANGER VT-3 Reject Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505640 1IA-11RHRH-015 [HANGER Vr-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505650 1A-12RHRH-007 HANGER VIT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505675 1A-12RHRH-011 HANGER VIT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level 11 of sum# 505625 and 505690 and notification#

505680 1A-12RHRH-012 HANGER VT7-3 Accept Examiner. 20256267 and 20256926 Expanded saunpie added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505685 1A-12RHRH-014 l

HANGER VIF-3 Reject Examiner. 20256267 and 20256926 VT-3 examination noted high spring can set Examination Performed by PSEG Certified Level II exceding code specifications notifications 505690 IA-12RHRH-015 HANGER VIT-3 Reject Examiner. 20256267 and 20256926 generated Examiner. Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505695 1 A12RHRH-01 7 ~HANGER %VT-3 Reject ... .. ..... .. ..... .. ._ .....

- 202 569..

2.6. . . .....

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 17 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 rxpdIIum siample auueo to outage uue to rejec~tlio Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505705 11A-12RHRH-019 HANGER VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505720 11A-12RHRH-016 HANGER IVT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505725 50572 1A-12RHRS-045

__ _ _ _ _ _ _ _ SUPPORT VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505730 1A-11 RHRH-001 HANGER VT-3 1APt Examiner. 20256267 and 20256926 Examination Performed by PSEG Certified Level 505765 11A-I IRHRH-021 HANGER VT-3 Accept Examiner. Notif.#20257798 As-Left after reset Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505765 11A-11 RHRH-021 HANGER VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505r780n IiA-1.2. 0DQ~nAA U.-. W____I I 'I flnnM j-D Examiner.

,- ___W."____ a- MA7UVPi 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505790 1A-12RHRH-020 HANGER IVT-3Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505795 1A-11RHRH-024 HANGER VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505815 IIA-RHRS-249 SUPPORT VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505820 1A-12RHRH-013 IHANGER VT-3 Accept Examiner. 20256267 and 20256926 Examninaion Performed by PSEG Certified Level iI 505830 IA-12RHRH-003 HANGER VT-3 Accept Examiner. None Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level 11 of sumr#505625 and 505690 and notificaiion#

505840 IA-12RHRH-006 HANGER VT-3 I~ccpt Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level Al of sum# 505625 and 505690 and notifications 505890 1P-I13RHH-009 IHANGER VT-3 Accept Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505895 IIP-13RHH-010 jHANGER VT-3 Accept Examiner. 20256267 and 20256926 A_

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 18 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505905 11C-13RHH-001 HANGER VT-3 Accept Examiner. 20256267 and 20256926

--... ' - - . + i......

Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505915 11A-12RHRH-023 HANGER VT-3 Accept Examiner. 20256267 and 20256926

.. . . _...................... _ _ Q Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505920 IIA-12RHRH-024 HANGER VT-3 Reject Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505930 1A-12RHRH-037 HANGER VT-3 Accept Examiner. ____ 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notification#

505935 1A-12RHRH-047 HANGER VT-3 Accept Examiner. 20256267 and 20256926

+/- I Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Level II of sum# 505625 and 505690 and notifications 505955 1A-12RHRH-026 HANGER VT-3 IReject Examiner. 20256267 and 20256926 Expanded sample added to outage due to rejection Examination Performed by PSEG Certified Levei ii OsumIF bUbb2b and 505b90 and notifications 505960 1A-11 RHRH-004 HANGER \VT-3 Reject Examiner. 120256267 and 20256926

+ I Exaina'tion- Perfo'r-med- by PSE-GCertified Level 1l 505970 IA-1 2RHRG-038 GUIDE VTr-3 Accept Examiner. !None _______

Examination Performed by PSEG Certified Level II 506125 1P-13FWR-018R RESTRAINT VT-3 Accept Examiner. None I. I I Exinton Performed by PSEG Certified Level 11 506225 1C-11SIS-105 SUPPORT TV!1-3 Accept Examiner. None I I Examination Performed by PSEG Certified Level II 506230 1C-11SIS-104 SUPPORT IvT-3 Accept Examiner. None I 1 ______ -

Examination Performed by PSEG Certified Level II 506260 lC-i SIS-131 SUPPORT VTr-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506285 IC-i1S1S-014 SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506295 11C-1 2SIA-024 ANCHOR VT-3 Accept Examiner. None I- I Examination Performed by PSEG Certified Level II 506370 11C-12SIG-138 GUIDE VT-3 Accept Examiner. None I + + I I 506395 I1C-12SIH-128 HANGER VT-3 Accept Examination Examiner.

Performed by PSEG Certified Level II None Examination Performed by PSEG Certified Level 11 506420 1 C-1 3SIA-006 jANCHOR bVT-3 JAccept I Examiner. None Examination Performed by PSEG Certified Level II 506500 11C-14SIS-005 SUPPORT VT-3 Accept Examiner. None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 19 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 506530 IC-I4SIG-158A GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506535 1C-1451G-158 GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506565 1C-14SIS-153 SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506620 1P-11SIS-025 SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506640 IP-11SIS-021 SUPPORT V_-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506675 1P-SIG-002 SUPPORT VT-3 Accept Examiner. None M_- Examination Performed by PSEG Certified Level II 506760 IC-11SIS-162 SUPPORT vr-3 Accept Acxept Examiner. None Examination Performed by PSEG Certified Level II 506765 1C11-15-161 SUPPORT 3 Accept Examiner. None Examination Performed by PSEG Certified Level II 506820 I P-12SIH-036 [HANGER Accept Examiner. None VT -3 Examination Performed by PSEG Certified Level II 506905 IC-12515-01 5 SUPPORT VTI-3 Exarnmii r. None A.ccept Examination Performed by PSEG Certified Level II 506910 1C-12SIS-014 SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 507055 1C-14SIG-169 GUIDE VT-3 Examiner. None Accept Examination Performed by PSEG Certified Level II 507760 IA-SIG-267 GUIDE VT-3 Accept Examiner. None . ....

Accept Examination Performed by PSEG Ce Le 508020 IP-SIH-015 _ _ _ _ _ _ HANGER VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 508065 1A-SIG-221 GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 508110 1A-SIH-208 HANGER VT-3 Examiner. None Examination Performed by PSEG Certified Level II i 508795 JlM-SWG-009 IGUIDE jVT-3 Accept Examiner. jNone ll- Examination Performed by PSEG Certified Level II 509165 1 _C-13SWG-3C IGUIDE IVT-3 A Examiner. _None Examination Performed by PSEG Certified Level II 509285 1C-I1ISWG-5B GUIDE ___________VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level ii 509290 1C-12SWG-3A I GUIDE VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 509320 1C-12SWH-9 HANGER VT-3 Accept Examiner. None Examination Performed by PSEG CertifIed LeveIl l 509345 IC-12SWG-12 GUIDE *Vr-3 Accent Examiner. None

- 7 - 1 I .. - 1............

Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan Page 20 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 examination Performed by Puti Ceruniea Level II 509385 II C-11 SWG-5A GUIDE VT-3 Accept Examiner. None 4

Examination Perormed by PSEG Certified Level II 509490 IA-SWH-039 SUPPORT VT-3 Accept_ Examiner. None 11 S/G LOWER VERT Examination Performed by PSEG Certified Level II 510821 SUPPORT SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 510822 SIRC-11SGNEC COMPRESSION STRUT VT-3 Accept Examiner. None

  1. 11 SERVICE WATER PP Examination Performed by PSEG Certified Level II 510930 STRAINER SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 510960 1#11 SERVICE WATER PUMP SUPPORT Vr-3 Accept Examiner. None t +

Examination Performed by PSEG Certified Level II 511465 11-CCE5 HEAT EXCHANGER SUPPORT VT-3 Reject Examiner. Notif. # 20257792

+

Examinaton Performed by PSEG Certified Level II 511520 11-SWEI PUMP SKIRT VT-I Accept Examiner. None I 4 Examination Performed by PSEG Certified Level II 511580 11-SWE7 STRAINER LEGS (4 EA.) VTI Accept Examiner. None Examnat ion PerformedbyPSEG Certifie Le b20030 iA-C;CG-04i GUiDE Examination Performed by PSEG Certified Level II 520110 1A-CCA-028 ANCHOR VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 520130 11A-CCH-022 HANGER_ VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 520590 IA-CSH-150 HANGER VT-3 Accept__ Examiner. None

+

Examination Performed by PSEG Certified Level II 522210 1A-MSAS-126 SUPPORT VT-3 Accept Examiner. None Examination Performed by PSEG Certified

._ Level 522280 1-13AFWA-041 ANCHOR VT-3 Accept Examiner. None Examination Performed by PSEG Certified Level II 950000 SPT-1-RC-001 ALL CLASS 1 SYSTEMS VT-2 Accept Examiner. None (CC) COMPONENT COOLING Examination Performed by PSEG Certified Level II 950300 SPT-1-CC-001 SYSTEM VT-2 Accept Examiner. None (CC) COMPONENT COOLING Examination Performed by PSEG Certified Level II 950350 SPT-1 -CC-002 SYSTEM VT-2 Accept Examiner. None (CC) COMPONENT COOLING Examination Performed by PSEG Certified Level II 950400 SP--C-0 SYSTEM VT-2 Accept Examiner. None (C)COMPONENT COOLING Examination Performed by PSEGCertified Level II 950450 ISPT-1-CC 004 -SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 950550 ISPT-1-CH-001 (CH) CHILLED WATER SYSTEM VT-2 Accept Examiner. None (CS) CONTAINMENT SPRAY Examination Performed by PSEG Certified Level II 950650I... 1SPT-1-CS-001

.....I ._

SYSTEM VVT-2 1Accept Fv- iner. None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 21 of 24 12/07/2005 RFO #17 ISI Examination Results Revision I (CS) CON IAI Examination Pertormed by PSEG Certitled Level II 950700 ISPT-1-CS-002 SYSTEM IVT-2 Accept Examiner. None (CS) CONTAINMENT SPRAY Examination Performed by PSEG Certified Level II 950750 SPT-1-CS-003 SYSTEM VT-2 Accept Examiner. _None (CS) CONTAINMENT SPRAY Examination Performed by PSEG Certified Level II 950800 SPT-1-CS-004 SYSTEM VT-2 Accept Examiner. None (CVC) CHEMICAL VOLUME Examination Performed by PSEG Certified Level II 950850 SPT-1-CV-001 CONTROL SYSTEM VT-2 Accept Examiner. None (DR) DEMINERALIZED WATER Examination Performed by PSEG Certified Level II 951150 SPT-1-DR-001 SYSTEM VT-2 Accept Examiner. None (RC) REACTOR COOLANT Examination Performed by PSEG Certified Level II 951500 SPT-1-RC-005 SYSTEM VT-2 Accept Examiner. None (RC) REACTOR COOLANT Examination Performed by PSEG Certified Level II 951510 SPT-1-RC-006 SYSTEM VT-2 Accept Examiner. None (RH) RESIDUAL HEAT REMOVAL Examination Performed by PSEG Certified Level II 951550 SPT-1-RH-001 SYSTEM VT-2 Accept Examiner. None (RH) RESIDUAL HEAT REMOVAL Examination Performed by PSEG Certified Level II 951600 SPT-1-RH-002 SYSTEM VT-2 Accept Examiner. None I'..--L kSA) 1M I ui'm MIM* I ~1cv I V T -2 AC ept Examination Performed by PSEG Certified Level 1i None Examination Performed by PSEG Certified Level II 9517 0 -SA-002 0 (SA) STATION AIR SYSTEM VT-2 Accept Examiner.

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 22 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 Examination Performed by PSEG Certified Level 11 953050 ISPT-1-SW-001 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None

+

Examination Performed by PSEG Certified Level 1 953150 ISPT-1-SW-003 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 1 953200 SPT-1 -SW-004 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level l1 953250 SPT-1-SW-005 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examrinafion Peformed by PSEG Certified Level II 953300 SPT-1-SW-006 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 Strainer packing leak noted and notification #

953350 SPT-1-SW-007 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. 20246405 was generated Examination Performed by PSEG Certified Level II 953400 SPT-1-SW-008 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 953500 SPT-1-SW-010 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 953600 SPT-1-SW-012 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examination Performed by PSEG Certified LevlI SPT 4~ASI ALO' (SW) SERVICE WATER SYSTEM VT-2 Awept Examination Performed by PSEG Certified Level 11 954000 SPT-1 -SW-020 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examinaton Prformed by-PSEG Certified L~evell -I 954050 SPT-1-SW-021 (SW) SER\VICE WA:TER SYSTEM ZVT-2 Accept Examiner. None Examination Performed by PSEG Certified Level 11 954200 SPT-1-SW-024 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Examnatin Prformed by PSEG Certified LvlI 954300 SPT-1-SW-026 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None Exmination Performed by PSEG Certified Level I 954350 Z-SPT-1-SW-027

--_I....

WATE SYSEM..-

(S)ERIC Accept',"- Examiner. None Examnaton erformed by PSEG Certified Level 11 954400 ISPT-1-SW-028 (SW) SERVICE WATER SYSTEM VT-2 Accept Examiner. None (BR) BORON RECOVERY xam on Performed by PSEG Certified Level 1-958010 NR-SPT-1-BR-001 SYSTEM VT-2 Accept Examiner. None (CS) CONTAINMENT SPRAY - Examination Performed by PSEG Certified Level II 958020 NR-SPT-1-CS-001 SYSTEM SYTM VT-2 Accept Examiner. None (CS) CONTAINMENT SPRAY Examination Performed by PSEG Certified Level II l 958030 I NR-SPT-1-CS-002 [SYSTEM VT-2 Accept Examiner. None

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 23 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 958040 INR-SPT-1-CV-001 CONTROL SYSTEM VT-2 Accept Examiner. None (CV) CHEMiCAL &lVOLUME Eixaminaion Performed by PSEG Certified Level II 958050 NR-SPT-1-CV-002 CONTROL SYSTEM VT-2 Accept Examiner. None (CV) CHEMICAL & VOLUME Examination Performed by PSEG Certified Level 11 958060 NR-SPT-1-CV-003 CONTROL SYSTEM VT-2 Accept_ Examiner.l None (CV) CHEMICAL & VOLUME Examination Performed by PSEG Certified Level 11 958070 NR-SPT-1-CV-004 CONTROL SYSTEM V{T-2 Accept Examiner. None (CV) CHEMICAL & VOLUME I Examination Performed by PSEG Certified Level 11 958080 NR-SPT-1-CV-005 CONTROL SYSTEM VT-2 Accept Examiner. None (CV) CHEMICAL & VOLUME Efxam~inatiion _Performred by PSEG etfedLvl 958090 NR-SPT-1-CV-006 CONTROL SYSTEM VT-2 Accept Examiner. None (CV) CHEMICAL & VOLUME VT-2 Examination Performed by PSEG Certified Level 11 958100 NR-SPT-1-CV-007 CONTROL SYSTEM VT-2 Accept Examiner. None RH) REHEAT REMOVAL V`1-2 Examination Performed by PSEG Certified Level 11 958110 NR-SPT-1-RH-001 SYSTEM VT-2 V _- Accept Examiner. None (RH) REHEAT REMOVAL Examinaton Performed byPEGC ied Leel i 958120 NR-SPT-1 -RH-002 SYSTEM VT-2 Accept Examiner. None (SJ) SAFETY INJECTION Examtion Perfomed by PSEG Certified Level ii 958130 NR-SPT-1 -S!-001 None Accept Examination Performed by PSEG Certified Level 11 SYSTEM 'v -17 Examiner.

958140 NR-SPT-1-SI-002 (SJ) SAFETY INJECTION None Accept Ex-am~ina-tion P'e~rf'orm-ed by PSEG Certified Level I 958150 NR-SPT-1-SI-003 SYSTEM Examiner. lNone Accept 958160 NR-SPT-1-SS-001 (SS) SAMPLING SYSTEM VT-2 Examiner.

Accept EaInto Prformed by PSEG Certified Level It None 958170 NR-SPT-1-SS-002 (SS) SAMPLING SYSTEM VT-2 Examiner.

Accept Examnaton Prfomed y PEG CrtiiedLevel 11 None 958180 NR-SPT-1-SS-003 (SS) SAMPLING SYSTEM VT-2 Examiner.

Accept Exmnation Perfre yPEG Certified Level II None 958190 NR-SPT-1-SS-004 (SS) SAMPLING SYSTEM VT-2 lAccept Examiner.

(WG)#1 1 WG COMPRESSOR Accept Examnaton Prfomed y PEG Certified Level 1I None 958200 NR-SPT-1-WG-001 PUMP VT-2 1Arr.ent Examiner.

(WG)#12 WG COMPRESSOR Accept Examination Performed by PSEG Certified Level 1I None 958210 INR-SPT-1-WG-002 PUMP VT-2 VT-2 Examiner. None Accept lExaminer.

Examination Performed by PSEG Certified Level 11 lNone 958220 NR-SPT-1-WG-003 (WG) DISCHARGE HEADER VT-2 Examiner. None Accept Examination Performed by PSEG Certified Level Ii-958230 NR-SPT-1-WG-004 (WG) SUCTION HEADER Accept Examiner. None Examination Performed by PSEG Certified Level II 958240 lNR-SPT-1 -WG-005 (WG) #11 WG DECAY TANK Examiner.

Examination Performed by PSEG Certified Level II t.--

958250 lNR-SPT- 1-WG-006 (WG) #12 WG DECAY TANK l Nonle

Salem Nuclear Generating Station, Unit I ISI Program Long Term Plan Page 24 of 24 12/07/2005 RFO #17 ISI Examination Results Revision 1 txaminauion rerrormea Dy PStt terUtieU Level 11 958260 NR-SPT-1-WG-007 (WG) #13 WG DECAY TANK VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level II 958265 NR-SPT-1-WG-008 (WG) #14 WG DECAY TANK VT-2 Accept Examiner. None Examination Performed by PSEG Certified Level If 958270 INR-SPT-1-WL-001 (WL) WASTE LIQUID SYSTEM VT-2 Accept Examiner. None

LR-NI06-0023 Enclosure 3 Salem Unit 1, RCP Flywheel Inspection Plan and Results

Salem Nuclear Generation Station, Unit 1 12/07/2005 ISI Program Long Term Plan Page 1 of 1

) #17 FlvwhAAl Fxamination Resilts Revision 0 iInterval Ultrasonic examination perrorme at the Framatome Facility during RCP Motor rebuild under 004000 2S-75P790 #12 RCP Motor Flywheel Volumetric UT-0° Accept Iorder# 50078574 None Interval Ultrasonic examination performed by Framatome at the Framatome Facility during RCP Motor rebuild under 004000 2S-75P790 #12 RCP Motor Flywheel Volumetric UT-45° Accept order# 50078574 None Interval Ultrasonic examination performed by Framatome at the Framatome Facility during RCP Motor rebuild under 004000 2S-75P790 #12 RCP Motor Flywheel Surface MT Accept order# 50078574 None Interval Ultrasonic examination performed by Framatome at the Framatome Facility during RCP Motor rebuild under 004000 2S-75P790 #12 RCP Motor Flywheel Surface PT Accept order# 50078574 None

LR-N06-0023 Enclosure 4 Salem Unit 1, IWL Examination Plan and Results

Salem Nuclear Generating Station, Unit 1 12/07/2005 Containment ISI Program Long Term Plan Page 1 of 10 RFP X17 IWI FxYminatinn PResiuts Revision 0 JADJ V I- vi-sual txAWIIIIaduo I reiu IIICrU Lay r;"=

900000 ICON-S1-QUAD-OOOA-01 A CYL ROW 01 CC Visual VT-G lAccept Level II Certified Personnel No Recordable Findings

___I

_CONCRETE SURFSCCES QUAD VT-G Visual Examination Performed By PSEG 900100 iCON-Sl-QUAD-OOOA-02 A CYLROW 02 CC Visual Level II Certified Personnel No Recordable Findings VT-GVk CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 900200 1CON-S1-QUAD-OOOA-03 A CYL ROW 03 CC Visual .............

VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 900300 ICON Sl-QUAD-OOOA-04 A CYL ROW 04 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 900400 ICON-SI -QUAD-OOOA-05 A CYL ROW 05 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 900500 ICON-S1-QUAD-OOOA-06 _ .

A CYL ROW 06 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD _

VT-G Visual Examination Performed By PSEG 900600 ICON-S1-QUAD-OOOA-07 4 4 A CYL ROW 07

- - f ICC Visual VT-G Accept 4 4 Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 900700 4 CON-S1-QUAD-OOOA-08 A CYL ROW 08 CC Visual VT-G jAccept Level II Certified Personnel No Recordable Findings

+ I-I ____ ___ - +

CONCRETE SURFACES QUAD I VT-G Visual Examination Performed By PSEG 1 No Recordable Findings 900800 CON-Sl-QUAD-OOOA-09

- - - - - - l A CYL ROW 09 CC Visual VT-G Accept -

Level ll Certified Personnel CONCRETE SURFACES QUAD l VT-G Visual Examination Performed By PSEG v.Ai'- i -IQtUA LJ-UU0t- I A CYL RJVVU 1 CC VMiUdl VI'-G Accept CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG-I 901000 CON-S-QUAD-OOOA-11 A CYL ROW 011 Cc Visual VT-G Accept Level 11Certified Personnel scaling < 3Rdeep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 901100 ICON-S1-QUAD-000A-12 A CYL ROW 012 Cc Vis ual VT-G Accept Level II Certified Personnel scaling <R3" deep 4 -- -- - - -

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 901200 ICON-S1-QUAD-OOOA-13 A CYL ROW 013 CC Vis ual VT-G Accept Level II Certified Personnel scaling <" ' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG I

scaling < 3"deep Visual VT-G Accept Level II Certified Personnel 901300 CON-S1-QUAD-OOOA-14 A CYL ROW 14 CC CONCRETE _ _ __

_ _ _ _ _SURFACES _ ____ _

QUAD . _ _._ VT-G Visual Examination Performed By PSEG 901400 CON-S1-QUAD-OOOA-15 A CYL ROW 15 CC Visual VT-G Accept Level 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 901500 ICON-S1-QUAD-OOOA-16 A CYL ROW 16 CC Visual VT-G Accept Level 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 901600 ICON-S 1-QUAD-OOOA-17 A CYL ROW 17 CC Visual VT-G Accept Level 11Certified Personnel scaling <3" deep CONCI ETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 901700 CON-lUQADWOOA18 A CYL,RROW 18 CC Visual V-:G Accept Level ll Certified Personnel scaling < 3" deep

_ _ I 901800 CON-S1-QUAD-OOOA-19 901900 CON-S1-QUAD-OOOA-20 A CYL ETE

_co_

'LF

.1 ROW SURFACES 19 QUAD C_RETE SURFACES QUAD A CYL- ROW 20 CONCRETE SURFACES QUAD cc - IiVisualVT-G cc sual Visual VT-G 1Accept Level ll Certified Personnel

'VT-G Visual Examination Performed By PSEG Acce Pt Level ll Certified Personnel VT-G Visual Examination _Per~formed By PSEG VT-G Visual Examination Performed By PSEG scaling 3_

scaling

<3 3 deep

< 3" deep 902000 CON-Sl-QUAD-000A-211 A CYL ROW 21 CC Visual VT-G jAccept Level II Certified Personnel scaling < 3" deep 4 1 CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 1902100 ICON-S1-QUAD-OOOA-22 IA CYL ROW 22 CC IVMsual VT-G jAccept Level lI Certified Personnel scalina < 3" deep

Salem Nuclear Generating Station, Unit 1 12/07/2005 Containment ISI Program Long Term Plan Page 2 of 10 RFO #17 IWL Examination Results Revision 0 V i -G visual Examination Performed By -SEG 902200 CON-S I-QUAD-OOOA-23 A CYL ROW 23 CC

-.--t Visual IVT-G Accept Level II Certified Personnel scaling < 3" deep 4

l, CONCRETE SURFACES QUAD v I W

VT-G Visual Examination Performed By PSEG 902300 CON-Sl-QUAD-OOOA-24 A CYL ROW 24 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 902400 CON-S1-QUAD-000A-25 A CYL ROW 25 cc Visual jVT-G Accept Level II Certified Personnel scaling < 3" deep EI.94', Moisture/intrusion barrier light to medium rust CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Not. 20257326 902500 CON-SI-QUAD-OOOB-01 B CYL ROW 01 Cc Visual IVT-G lAccept Level II Certified Personnel CC has surface irregularities, scaling < 3" deep S ......

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 902600 CON-811-QUAD-00013-02 B CYL ROW 02 cc Visual VT-G Accept Level II Certified Personnel No Recordable Findings _

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 902700 CON-S`I-QUAD-00013-03 B CYL ROW 03 Cc Visual VT-G Accept Level II Certified Personnel No Recordable Findings vT-G visual Examination Performed

_ _ =. _

CONCRETE SURFACES QUAD By PSEG 902800 1CON-S1 -QUAD-OOOB-04 B CYL ROW 04 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Ei.120' looking NW, east side of outer Pen., 5 1" 902900 ICON-S1-QUAD-OOOB-05 +

B CYL ROW 05 CC Visual VT-G

_ Accept Level 11Certified Personnel conduits coming out of CC wall w/wires.

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 903000 ICON-Si-QUAD-OOOB-06 B CYL ROW 06 CC Visual VT-G Accept Level 11Certified Personnel No Recordable Findings 4 +

CONCRETE SURFAC;ES QUAD vT-G Visuai Examination Performed By PSEG 903100 iCON-SI-QUAD-OOOB-07 a

B CYL ROW 07 CC Visual VT-G 1Accept I Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD r-G Visual Examination Performed By PSEG 903200 IACON-SI-QUAD-OOOB-08 B CYL ROW 08 CC Visual VT-G Accept ivel 11Certified Personnel No Recordable_ Findings CONCRETE SURFACES QUAD r-G Visual Examination Performed By PSEG 903300 ICON-S 1-QUAD-OOOB-09 B CYL ROW 09 CC __

Visual VT-G Accept .vel 11Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD r-G Visual Examination Performed By PSEG 903400 ICON-S i-QUAD-OOOB-110_ B CYL ROW 10 CC Visual VT-G Accept .vel 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD .1....................... 17-Visual Examination Performed By PSEG 903500 ICON-S1-QUAD-OOOB-11 B CYL ROW 11 CC _

Visual ___

VT-G lAccept

.vel 11Certified Personnel scaling < 3" deep _.

CONCRETE SURFACES QUAD r-G Visual Examination Performed By PSEG 903600 ICON-S1-QUAD-OOOB-12 B CYL ROW 12 Cc Visual VT-G Accept .vel 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD T-G Visual Examination Performed By PSEG 1

903700 CON-Si -QUAD-OOOB-13 IB CYL ROW 13 Cc Visual VT-G Accept .vel iI Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD T-G Visual Examination Performed By PSEG 903800 ICON-S I-QUAD-OOOB-14 B CYL ROW 14 CC Visual VT-G Accept .vel 11Certified Personnel scaling < 3" deep CONCRETE SUR ES UAD r-G Visual Examination Perform ed By PSEG 903900 ICON-S1I-QUAD-000B-15 B CYL ROW 15 CC Visual VT-G Accept .vel 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 904000 ICON-S1-QUAD-000B-16 B CYL ROW 16 CC Visual V`1-G3 Accept Level II Certified Personnel scaling < 3" deep .

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 904100 jCON-S i-QUAD-OOOB-1 7_ B CYL ROW 17 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 904200 ICON-S 1-QUAD-OOOB-18 B CYL ROW 18 Cc Visual jVT-G Accept JLevel II Certified Personnel scaling < 3"deep

Salem Nuclear Generating Station, Unit 1 12/07/2005 Containment ISI Program Long Term Plan Page 3 of 10 RFO #17 IWL Fxaminatinn Resuilts Revision 0 VI -U VIsUdI r-A2WIHIMaIOUI rtra. ,ormed By rPSEG 904300 ICON-S1-QUAD-OOOB-19 B CYL ROW 19 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD [ Val Examination Perk brmed By PSEG 904400 ICON-S 1-QUAD-0W0B-20 [B CYL ROW 20 CC Visual i irtified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Perk bmmed By PSEG 904500 ICON-S1-QUAD-OOOB-21 B CYL ROW 21 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep _________i___

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 904600 ICON-S1-QUAD-OOOB-22 B CYL ROW 22 CC Visual VT-G Accept Level II Certified Personnel scaling < 3' deep ICON CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEGt 904700 9070 CON-S1-QUAD-OOOB-23 v S-UD-0B2 B CYL ROW 23 CONCRETE SURFACES QUAD CC la Visual TV VT-G Accept Level 11Certified Personnel VT-G Visual Examination Performed By PSEG scaling < 3" deep 904800 ICON-S 1-QUAD-OOOB-24 .

B CYL ROW 24 CC Visual VT-G jAccept w

Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD

_ =

VT-G Visual Examination Performed By PSEG 904900 ICON-S1 -QUAD-OOOB-25 B CYL ROW 25 CC Visual VT-G lAccept Level II Certified Personnel scaling < 3" deep I I -4 EI.94', Moisture/intrusion barrier light to medium rust CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Not. 20257326 905000 ICON-SI -QUAD-OOOC-01 C CYL ROW 01 CC Visual VT-G Accept Level II Certified Personnel CC has surface irregularities, scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905100. .. .. I.CON-S1-QUAD-000C-02 -

C CYL ROW 02 CC Visual VT-G Accept Level II Certified Personnel scaling < 3' deep

...........I

_ _ . , I CONCRETE SURFACES QUAD 'v'T-G visuai Exarriiriaiiuri Perforrried By PSEG 905200 CON-SI-QUAD-OOOC-03

+ +

C CYL ROW 03 cc I--I Visual VT-G

-i lAccept +

Level II Certified Personnel I

scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905300 CON-S1-QUAD-000C-04 C CYL ROW 04 CC Visual VT-G Accept Level II Certified Personnel scaling < 3' deep

=L CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905400 CON-S1-QUAD-O0OC-05 C CYL ROW 05 CC Visual VT-G Accept Level 11Certified Personnel surface scaling < 3"deep--,

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905500 CON-SI1-QUAD-OOOC-06 C CYL ROW 06 CC Visual VT-G Accept Level II Certified Personnel Surface scaling < 3" deep_ ______

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905600 lCON-S1-QUAD-OOOC-07 lC CYL ROW 07 CC Visual VT-G Accept Level II Certified Personnel Surface scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905700 ....ICON-S 1-QUAD-O0OC-08 C CYL ROW 08 CC Visual VT-G Accept Level II Certified Personnel Surface scaling < 3" deep ___

4 CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905800 1CON-S1 -QUAD-OOOC-09 C CYL ROW 09 CC Visual VT-G Accept Level .. Certified Personnel Surface scaling < 3"deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 905900 ICON-S1-QUAD-OOOC-10 C CYL ROW 10 CC Visual VT-G Accept Level II Certified Personnel Surface scaling < 3" deep_______

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 906000 ICON-S1-QUAD-OOOC-11 C CYL ROW 11 cc Visual VT-G Accept Level II Certified Personnel ESurface scaling < deepb3" tomedium___

CONCRETE SURFACES QUAD CC VT-G Visual Examination Performed By PSEG 906100 CON-S1-QUAD-000C-12 C CYL ROW 12 Visual VT-G Accept Level II Certified Personnel Surface scaling < 3" deep CONCRETE SURFACES QUAD CC VT-G Visual Examination Performed By PSEG 906200 CON-S1-QUAD-OOOC-13 C CYL ROW 13 Visual VT-G Accept Level II Certified Personnel Surface scaling <3 " deep CONC-RE-TE SURFACES QUAD CC VT-G Visual Examination Performed By PSEG 906300 CON-SI1-QUAD-OOOC-14 C CYL ROW 14 Visual jT-G jAccept jL eIi Cemrtiid Personnel Surface scaling < 3" deep L

Salem Nuclear Generating Station, Unit 1 12/07/2005 Containment ISI Program Long Term Plan Page 4 of 10 Revision 0 906400 CON-Sl-QUAD-OOOC-15 C CYL ROW 15 CC Visual lVT-G Accept Level II Certified Personnel Surface scaling < 3' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 906500 CON-SI -QUAD-OOOC-16 C CYL ROW 16 CC Visual VT-G Accept Level iI Certified Personnel Surface scaling < 3' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 906600 CON-S1-QUAD-OOOC-17 C CYL ROW 17 CC Visual VT-G Accept Level II Certified Personnel Surface scaling < 3" deep FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 906700 CON-SI-QUAD-OOOC-18 C CYL ROW 18 CC Visual VT-G Accept Level 11Certified Personnel horizontal joints have surface scaling < 3" deep FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 906800 CON-51-QUAD-OOOC-19 C CYL ROW 19 CC Visual VT-G Accept Level II Certified Personnel horizontal joints have surface scaling < 3" deep FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 906900 CON-S1-QUAD-OOOC-20 C CYL ROW 20 CC Visual VT-G Accept Level II Certified Personnel horizontal joints have surface scaling < 3" deep

. FlH Bldg roof, trom cont vent duct to ground cabie CONCRETE SURFACES QUAD CVT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 907000 ICON-1-QUAD-000C-21 C CYL ROW 21 CC Visual VT-GAccept Level II Certified Personnel horizontal joints have surface scaling < 3" deep FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 907100 lCON-S1-QUAD-OOOC-22 __

C CYL ROW 22 CC Visual VT-G Accept Level II Certified Personnel horizontal joints have surface scaling < 3" deep FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 907200 CON-S1-QUAD-OOOC-23 C CYL ROW 23 ICC lVisual VT-G Accept Level II Certified Personnel horizontal joints have surface scaling < 3" deep t I I-I-----*--*-'+-'t' 4 I FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 907300 CON-S1-QUAD-OOOC-24 C CYL ROW 24 CC Visual VT-G Accept Level 11Certified Personnel horizontal joints have surface scaling < 3" deep

+ 4 FH Bldg roof, from cont vent duct to ground cable CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG and 2 blocks past ground cable Misc. vertical and 907400 CON-S1-QUAD-OOOC-25 C CYL ROW 25 Cc Visual VT-G Accept Level II Certified Personnel horizontal joints have surface scaling < 3" deep Area between Containment and FH bldg. Behind CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Door Aux 130-1, Security Door 126, No recordable 907500 CON-Sl-QUAD-OOOD-01 D CYL ROW 01 CC Visual VT-G JAccept Level II Certified Personnel findings _,&

Salem Nuclear Generating Station, Unit I 12/07/2005 Containment ISI Program Long Term Plan Page 5 of 10 RFO #17 IWL Examination Results Revision 0 El.107' - 120', (by FH stairwell) moisture barrier seal bolting has medium rust. Not. 20257326 Area between Containment and FH bldg. Behind CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Door Aux 130-1, Security Door 126, No recordable 907600 CON-SI-QUAD-OOOD-02 D CYL ROW 02 CC Visual VT-G Accept Level II Certified Personnel findings El.107' - 120', (by FH stairwell) moisture barrier seal bolting has medium rust Not. 20257326 Area between Containment and FH bldg. Behind CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Door Aux 130-1, Security Door 126, No recordable 907700 ICON-S1-QUAD-OOOD-03 D CYL ROW 03 CC Visual IVT-G Accept Level II Certified Personnel findings El.107' - 120', (by FH stairwell) moisture barrier seal bolting has medium rust Not. 20257326 Area between Containment and FH bldg. Behind CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Door Aux 130-1, Security Door 126, No recordable 907800 jCON-S1-QUAD-OOOD-04 D CYL ROW 04 ICC iVisual VT-G Accept Level II Certified Personnel findings El.107' - 120', (by FH stairwell) moisture barrier seal bolting has medium rust Not. 20257326 Area between Containment and FH bldg. Behind CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Door Aux 130-1, Security Door 126, No recordable 907900 CON-S1-QUAD-OOOD-05 D CYL ROW 05 CC Visual VT-G Accept Level II Certified Personnel findings Area between Containment and FH bldg. Behind CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Door Aux 130-1, Security Door 126, No recordable 908000 CON-S1-QUAD-OOOD-06 D CYL ROW 06 CC Visual VT-G Accept Level II Certified Personnel findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 908100 CON-SI-QUAD-OOOD-07 D CYL ROW 07 CC Visual VT-G Accept Level II Certified Personnel No recordable findings IVT-G Visual Examination Performed By PSEG

- Between 130' cont vent duct and 130' airlock.

CONCRETE SURFACES QUAD Surface scaling < 3" deep at 131', 7 areas with the 908200 CON-SI-QUAD-OOOD-08 D CYL ROW 08 CC Visual VT-G Accept Level 11Certified Personnel largest being 5"x 8" CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 908300 CON-S1-QUAD-000D-09 D CYL ROW 09 CC Visual VT-G Accept Level iI Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 908400 +!CON-S1-QUAD-OOOD-10 D CYL ROW 10 ICC Visual VT-G !Accept Level 11Certified Personnel inaccessible

+

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 908500 ICON-S 1-QUAD-OOOD-1 1 D CYLROW11 CC Visual VT-G Accept Level 11Certified Personnel inaccessible

- - ........ - - - . ...... - e - ...

-n CONCRETE SURFACES QUAD VT-G Visual Examinaton Performed By PSEG Surface scaling < 3' deep, Areas under duct work 908600 ICON-S1-QUAD-OOOD-12 D CYL ROW 12 CC Visual VT-G Accept Level 11Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3' deep, Areas under duct work 908700 RCON-S1-QUAD-OOOD-13 D CYL ROW 13 Visual VT-G Accept Level 11Certified Personnel inaccessible 908800 CON-SI-QUAD-OOOD-14 CONCRETE SURFACES D CYL ROW 14 QUAD Icc Msua! IVT C Acrent VT-G Visual Examination Performed Level 11Certified Personnel By PSEG Surface scaling < 3" deep, Areas under duct work inaccessible

Salem Nuclear Generating Station, Unit I 12/07/2005 Containment ISI Program Long Term Plan Page 6 of 10 RFC) #17 IWL Exaiminatioin Resultsi Revision 0 UJINAURL I t our" MIao %AUPLp V 1- Visual txarninduon rPWiuonud Dy romi.7 Surface scaling c 3 aeep, Areas under duct work 908900 ICON-S1-QUAD-OOOD-15 D CYL ROW 15 CC Visual [VT-G jAccept Level II Certified Personnel inaccessible f . "

CONCRETE suRFAcES QUAD VT-G Visual Examination Performed By PSEG r

Surface scaling < 3" deep, Areas under duct work 909000 ICON-S1-QUAD-OOOD-16 D CYL ROW 16 ICC Visual VT-G lAccept Level II Certified Personnel inaccessible

-t 4 4 1 -

CONCRETE SURFACES QUAD sua xamination Performed By PSEG Surface scaling < 3' deep, Areas under duct work 909100 ICON-S1 -QUAD-OOOD-17 D CYL ROW 17 cc Visual VT-G Accept Level II Certified Personnel inaccessible 4 _

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work I

909200 CON-S 1-QUAD-OOOD-1 8 D CYL ROW 18 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD vT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 909300 jCON-Sl-QUAD-OOOD-19 D CYL ROW 19 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACS VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work I

909400 CON-S 1-QUAD-OOOD-20 D CYL ROW 20 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 909500 1CON-S 1-QUAD-OOOD-21 D CYL ROW 21 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 909600 ICON-S 1-QUAD-OOOD-22 D CYL ROW 22 cc Visual VT-G Accept Level IICertified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 909700 CON-S1-QUAD-OOOD-23 D CYL ROW 23 CC Visual VT-G Accept Level II Certified Personnel inaccessible inaccessiibe

_CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work SOSSO CN-S1QUA-OOO-24 D CYL ROWv 24C I ALcupt Levei ii Ceiuied Persuriii CONCRETE SURFACES QUAD VT Vis-u-al Exam~inati~on -Perfo-rm'ed By PSEG Surface scaling < 3" deep, Areas under duct work 909900 CON-S1-QUAD-OOOD-25 D CYL ROW 25 CC Visual VTr-G Accept Level 11Certified Personnel inaccessible CONCRETE SURFACES QUAD- VT-G Visual Examination Performed By PSEG 910000 CON-S1-QUAD-OOOA-078 A ELECT PEN AREA CC Visual VT-G Accept Level ll Certified Personnel No recordable findings seal/moisturerintrusion barrier (water stop), brown coloring(rust) being absorded in coating, also hold CONCRETE SURFACES QUAD- VTr-G Visual Examination Performed By PSEG down bolts, steel, washers and nuts are degrading.

910100 ICON-S1-QUAD-OOOD-078 D MECH PEN AREA CC LVisual VT-G Accept Level . Certified Personnel Not. 20257326 _

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 910200 CON-S1-QUAD-000A-26 A DOME ROW 26 Cc Visual VT-G Accept Level 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 910300 CON-S1 -QUAD-OOOA-27 A DOME ROW 27 CC Visual VT-G Accept Level ll Certified Personnel CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 910400 CON-SI -QUAD-OOOA-28 .A DOME ROW 28 CC Visual VT-G Accept Level ll Certified Personnel scaling < 3" deep

+ +-+ - I -

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 910500 I

ICON-S1-QUAD-OOOA-29 I A DOME ROW 29 CC Visual VT-G Accept Level I! Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 910600 ICON-S1-QUAD-OOOA-30 A DOME ROW 30 cc Visual VT-G Accept Level ll Certified Personnel scaling < 3" deep 9U CONCRETE SURFACES A DOME ROW 31 QUAD VT-G Accept SVT-G Visual Examination Performed By PSEGI CC Visual Level 11Certified Personnel lscaling < 3" deep CONCRETE SURFACES QUAD VVT-G Visual Examination Performed By PSEG 910800 ICON-S1-QUAD-OOOA-32 A DOME ROW 32 cc Visual VT-G Accept Level 11Certified Personnel Iscaling < 3' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 910900 !CON-SI-QUADl-OOOfA-33 A DOME ROW 33 ICC G'Accept SLevel 11Cerfified Pe3sonnel Iscaling, <.....

3'-----deen

'i 1.11-11,111-11, --------

Salem Nuclear Generating Station, Unit I 12/07/2005 Containment ISI Program Long Term Plan Page 7 of 10 RFP :1f17 IWI Fxvnminftinn RPaii*e Revision 0 vI -" visual examination Perrormed By PbtE 911000 ICON-SI-QUAD-OOOA-34 A DOME ROW 34 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep 4 4 4 4 + + - 4 CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 1

911100 CON-S1-QUAD-OOOA-35 A DOME ROW 35 CC Visual VT-G Accept Level II Certified Personnel scaling < 3' deep

-4 4 4- 4- - 4 4 CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911200 jCON-S1-QUAD-OOOA-36 A DOME ROW 36 CC Visual VT-G Accept Level iI Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911300 CON-S1-QUAD-OOOA-37 A DOME ROW 37 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911400 CON-S1-QUAD-OOOA-38 A DOME ROW 38 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911500 CON-S1-QUAD-OOOA-39 A DOME ROW 39 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911600 CON-S1-QUAD-000A-40 A DOME ROW 40 CC Visual VT-G Accept Level 11Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911700 CON-S1-QUAD-OOOA-41 A DOME ROW 41 CC Visual VT-G Accept Level 11Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 911800 CON-S1-QUAD-OOOA-42 A DOME ROW 42 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG I iauu I-VUMO-uu1-Q-0 ADOMvIE I3 ROWN 43 1 AC Iyisual IV'I-G Mcoept :Levei %,iUItIu

rtonUiii No Retordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 912000 ICON-S1-QUAD-000A-44 4 4-A DOME ROW 44 CC 4---- Visual VT-G 1Accept Level II Certified Personnel 4

No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 912100 ICON-Si -QUAD-OOOA-45 4

A DOME ROW 45 CC

+-+

Visual 1

VT-G jAccept Level II Certified Personnel 4 4 - 1-No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 912200 CON-Sl -QUAD-OOOA-46 _

A DOME ROW 46 CC Visual VT-G 4-4- _

IAccept Level II Certified Personnel +

No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG I

912300 CON-S1-QUAD-OOOB-26 _ S B DOME ROW 26 CC Visual VT-G Accept Level II Certified Personnel _

scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 912400 ICON-S1-QUAD-000C-26 C DOME ROW 26 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD T-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 912500 CON-S1-QUAD-OOOD-26 D DOME ROW 26 Cc Visual VT-G Accept svel 11Certified Personnel inaccessible CONCRETE SURFACES QUAD T-G Visual Examination Performed By PSEG 912600 1CON-Si -QUAD-OOOB-27 B DOME ROW 27 CC Visual VT-G Accept .vel 11Certified Personnel scaling < 3" deep 4 _ __.4- -4 CONCRETE SURFACES QUAD T-G Visual Examination Performed By PSEG 912700 CON-S1-QUAD-OOOC-27 C DOME ROW 27 CC Visual VT-G Accept Level 11Certified Personnel Iscaling < 3" deep 4 4 CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG ISurface scaling < 3" deep, Areas under duct work 912800 ICON-S1-QUAD-OOOD-27 D DOME ROW 27 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 912900 CON-SI-QUAD-OOOB-28 B DOME ROW 28 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD-I VT-G Visual Examination Performed By PSEG 913000 iCON-S1-QUAD-OOOC-28 C DOME ROW 28 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep 9IS D 2 CONCRETE SURFACES QUAD C IVT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 1913100 ICON-S 1-QUAD-OOOD-28 1D DOME ROW 28 -- C VksuaI - G eve! 11Certified PersonnA! innrrePsihIP

Salem Nuclear Generating Station, Unit I 12/07/2005 Containment ISI Program Long Term Plan Page 8 of 10 RFC) H17 IWI Exvnminnfinn Paciisfi Revision 0 913200 ICON-S1-QUAD-OOOB-29 B DOME ROW 29 CC Visual IVT-G Accept lLevel iI Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 913300 CON-S1-QUAD-OOOC-29 C DOME ROW 29 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 913400 CON-Sl-QUAD-OOOD-29 D DOME ROW 29 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 913500 CON-S1-QUAD-OOOB-30 B DOME ROW 30 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 913600 CON-S1-QUAD-OOOC-30 C DOME ROW 30 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 913700 CON-S1-QUAD-OOOD-30 D DOME ROW 30 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 913800 CON-S1-QUAD-O00B-31 B DOME ROW 31 CC Visual VT-G Accept Level 11Certified Personnel scaling <3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 913900 CON-S1-QUAD-OOOC-31 C DOME ROW 31 CC Visual VT-G Accept Level II Certified Personnel scaling < 3' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 914000 CON-S1-QUAD-OOOD-31 D DOME ROW 31 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG V 11 1IUV .JId I-WUPML,-VUuuO-, D DUJINIE ROjvv 32 t%.A I VIbUw V I-%, I/ uu&p LUVtII ii Ctrulvd ruibuIohIw I uiIi1 -a 3" p d CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 914200 CON-S1-QUAD-000C-32 C DOME ROW 32 CC Visual VT-G Accept Level I; Certified Personnel uscaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 914300 CON-S1-QUAD-OOOD-32 D DOME ROW 32 CC Visual VT-G Accept Level II Certified Personnel sinaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 914400 CON-S 1-QUAD-000B-33 B DOME ROW 33 CC Visual VT-G Accept Level _1 Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 914500 ICON-S1-QUAD-000C-33 4C DOME ROW 33 _ CC _ Visual VT-G-4 lAccept Level II Certified Personnel _

scaling < 3' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3' deep, Areas under duct work 914600 CON-S 1-QUAD-OOOD-33 D DOME ROW 33 CC Visual VT-G 1Accept Level iI Certified Personnel inaccessible CONCRETE SURFACES QUAD I GVisual Examination Performed By PSEG 914700 CON-S1-QUAD-OOOB-34 IB DOME ROW 34 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 914800 ICON-S1-QUAD-OOOC-34 4 C DOME ROW 34 CC 4-4 Visual VT-G

-i lAccept Level II Certified Personnel _

scaling < 3' deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3' deep, Areas under duct work 1

914900 CON-Si-QUAD-OOOD-34 D DOME ROW 34 CC Visual VT-G lAccept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 915000 ICON-Sl-QUAD-OOOB-35 B DOME ROW 35 CC Visual VT-G jAccept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 915100 1CON-Sl-QUAD-OOOC-35 C DOME ROW 35 CC Visual VT-G jAccept Level 11Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 915200 ICON-S1-QUAD-OOOD-35 D DOME ROW 35 cc _

Visual

_4 VT-G jAccept Level II Certified Personnel

.~

inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG lqir5-An CON-Sl-QUAD-OOOB-36 _ DOME fl ROWI 3a19 50 Cc IVisu... "lT-GIIA -,ept 1Level ll Coetified Personnel scaling < 3" deep

! I

Salem Nuclear Generating Station, Unit 1 12/07/2005 Containment ISI Program Long Term Plan Page 9 of 10 RFO #17 IWL Examination Results Revision 0 V I -G visual Examination Performed By 915400 ICON-S1-QUAD-OOOC-36 C DOME ROW 36 CC Visual IVT-G lAccept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 915500 CON-S1-QUAD-OOOD-36 D DOME ROW 36 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 915600 CON-S1-QUAD-OOOB-37 B DOME ROW 37 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 915700 CON-S1-QUAD-OOOC-37 C DOME ROW 37 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 915800 CON-Sl-QUAD-OOOD-37 D DOME ROW 37 CC Visual VT-G Accept Level o1Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 915900 CON-S1-QUAD-OOOB-38 B DOME ROW 38 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD Examination Performed By PSEG 916000 CON-S1-QUAD-OOOC-38 C DOME ROW 38 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCREKTI S UKIRACEtS UUAD Vi -G visual Examination Performed By PSEG Surface scaling < 3"deep, Areas under duct work 916100 CON-SII-QUAD-000D-38 D DOME ROW 38 Cc Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 916200 CON-S 1-QUAD-OOOB-39 B DOME ROW 39 CC Visual VT-G Accept Level II Certified Personnel scaling < 3" deep CONCRETE SURFACES QUAD_ VT-G Visual Examination Performed By PSEG ONSi -14UADJ-OOO-39 C DOMiE ROvv 39 ICC 'Visuai vi-tu il~ccept Levei ii Certified Personnei scaling < 3 deep CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 916400 CON-S1-QUAD-OOOD-39 D DOME ROW 39 CC Visual VT-G jAccept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 916500 CON-S 1-QUAD-OOOB-40 B DOME ROW 40 CC Visual VT-G lAccept Level II Certified Personnel No Recordable Findings SURFACES QUD _ VT-G Visual Examination Performed By PSEG 916600 ICON-S1-QUAD-OOOC-40 IC DOME ROW 40 CC Visual JVT-G jAccept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG Surface scaling < 3" deep, Areas under duct work 916650 jCON-S -QUAD-OOOD-40 D DOME ROW 40 CC Visual VT-G jAccept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 916700 1CON-S1 -QUAD-OOOB-41 B DOME ROW 41 CC Visual VT-G jAccept Level II Certified Personnel No Recordable Findings A:= _

CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 916800 ICON-S1-QUAD-OOOC-41 4 C DOME ROW 41 CC Visual VT-G IAccept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG No Recordable Findings , Areas under duct work 916900 CON-S1 -QUAD-000D-41 D DOME ROW 41 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 917000 ICON-S1 -QUAD-OOOB-42 B DOME ROW 42 Cc Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 917100 ICON-S 1-QUAD-OOOC-42 C DOME ROW 42 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG No Recordable Findings, Areas under duct work 917200 CON-S1-QUAD-00OD42 D DOME ROW 42 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 917300 CON-Si -QUAD-OOOB-43 B DOME ROW 43 Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD 1CC VT-G Visual Examination Performed By PSEG 1917400 rCONS1 -QUAD=O00C=43 IC DOME OW 43 IC,^- IIr.-I,,... ._R

_ L-1 Z I72, 1- ~ - ~... Ievl Certified 1........ ..

Personnel

_ _I, _ _ __--

No Recordable Findings

- ... I... .. .1..........

I.... . ...

Salem Nuclear Generating Station, Unit I 12/07/2005 Containment ISI Program Long Term Plan Page 10 of 10 RFO #17 IWL Examination Results Revision 0 v I-G visual Examination Performed By I-SEG No Kecordaole Findings, Areas under duct work 917500 ICON-SI -QUAD-OOOD-43 D DOME ROW 43 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 917600 CON-S1-QUAD-OOOB-44 IB DOME ROW 44 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 917700 CON-S1 -QUAD-OOOC-44 C DOME ROW 44 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG No Recordable Findings, Areas under duct work 917800 CON-S1-QUAD-OOOD-44 D DOME ROW 44 CC Visual VT-G Accept Level 11Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 917900 CON-S1-QUAD-OOOB-45 B DOME ROW 45 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 918000 CON-S1-QUAD-OOOC-45 C DOME ROW 45 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG No Recordable Findings, Areas under duct work 918100 CON-Sl-QUAD-OOOD-45 D DOME ROW 45 CC Visual VT-G Accept Level II Certified Personnel inaccessible CONCRETE SURFACES QUAD VT-G Visual Examination Performed ByPSEG 918200 CON-S1-QUAD-OOOB-46 B DOME ROW 46 -

CC VsuisuayT-GIAccept Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG 918300 CON-S1-QUAD-000C-46 CDOME ROW 46 CC Visual VT-G Accept Level II Certified Personnel No Recordable Findings CONCRETE SURFACES QUAD VT-G Visual Examination Performed By PSEG No Recordable Findings, Areas under duct work CO-S-%QUMD-0000-46 UUIvIRMUVV '+0 Du Lev i i C rtife Persnneiinaccessible__

LR-N06-0023 Enclosure 5 Salem Unit 1, Owners Activity Report

S1 RFO#1 7 FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: S1RFO#17 Owner: Public Service Electric & Gas Compman Plant: Salem Nuclear Generatinn Station Unit No: 1 Commercial Service Date: 07/01/77 Refueling Outage No.: RFO #17 Current inspection interval: Third Current inspection period: Second Edition and Addenda of Section Xl applicable to the inspection plan: 1998 Edition 2000 Addenda,-

Appendix Vil exams were performed to the 1998 Edition 2000 Addenda as amended by Final Rule - and IWE/IWL was performed to the1998 Edition, 1998 Addenda Date and revision of inspection plan: 11/200;3 Rev. I Change 7 Edition and Addenda of Section Xl applicable repairs and replacements, if different than the inspection plan: Class 1, 2, & 3 - 1998 Edition. 2000 Addenda Class MC- 1992 Edition / 1992 Addenda.

CERTIFICATE OF CONFORMANCE I certify that the statements made in-this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations, and corrective measures represented by this report conform to the requirements of Section Xl.

Certificate of Authorization No.: N/A Expiration Date: N/A Signed: & 10v. J4an-vJC 4 -tQte ,

Owner or Owner's De;ignee, Titie dtDate q1 CERTIFICATE OF INSERVICE INSPECTION I the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or providence of New Jersey and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, during the period 06/04/2004 to 11/6/2005, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________ ______ __ Commissions ton Bo

'--ifspector's Sdaturew National Board, State, Province, and Endorsements Date PDd Page 1 of 5

SI RFO#1 7 Table I Salfe Nuclear Generating Station Unit I ISI Program Long Term Plan Inservice Inspection ExlanirEition Sunwty For The Third Inteval ASNE 1998 Code Edition - 2000 Addenda I-lr I - -DX1 a BA 28 28 40/ 0 00/a 4°h See Noe#1 B-B 8 5 1 20% 1 20% 0 0/o 40!% See Noe #4 B-D 33 30 4 13%/ _ 3 10% 0 0°/h Z3% SeeNote/2 B-G1 12 8 0 0/o 1 8% 0 0% 8% SeeNoe#1 B-G2 83 83 30 35%/ _ 0 0%/o 0 0/o 35/%

B4( 62 13 7 54% 2 15% 0 0/o 69/o See N & tiWE B-L-1 4 1 1 25% 0 _ 0 0% 0 0%/ 25% #4 See Nd,3& We B-L-2 4 1 0 0% 0 0%/ 0 0% 0%0 #4 See NrtEOi &We B-DM 2 1 0 0% 0 0% 0 OD/. OD/0 #4 See Noe3&Nie B-M2 30 4 4 14% 0 0% 0 OD/. 14%6 #4 B-N-1 3 3 1 34%0 _ 0 0% 0 0% 34%0  ;

B4N2 1 1 0 °°/° 0 0°/° °°/° 0 0% SeeNoe#1 BN-3 14 14 0 0% 0 0% 0 0%0 0% SeeNote#1 B-O 1 1 0 0% 0 0% 0 0% 0% SeeNoe#1 B-P 3 3 3 100%/ _ 0 0%0 0 0% 1C0%_/

0 B-P/C-H 2 2 2 10/O _0 0%

0 O1o 1W/a ____

C-A 55 21 8 33% - 1 5°h 0 0% 43% SeeNote#4 C-B 22 8 2 25%/a 2 25% 0 0/. 50°/O SeeNote#4 C-C 251 32 12 3B30/ _ 2 6% 0 0° 44% SeeNoe#4 C-D 9 2 1 5D%/ _ 0 0°/O 0 0°h/ 500/° SeeNote#4 C-G 24 3 1 33%/6 0 0°h 0 0°h 33°h SeeNoe#4 C-H 59 59 57 9701a 1 20/a 0 0°/O 59%_ _

Cl-ID-B 4 4 4 10D1h 0 00/O 0 0D%. 10D% _ _

DA 217 33 13 39h/a 8 24% 0 0°h_ 630°h D-B 55 54 54 9° _ 0 0°h/ 0 0°h 990°h F-A 1842 307 108 35°h/ 77 25°h 0 0°h/ 6D0°/

RA 3129 16D 49 31% 27 170/h 0 0°/O 48%h Noes

1) Defim- Penrissible 3) To Be Exanirej Oly t sseeeeed fr Krtwree Rar o-B-A B-G1 VdcuTstic Exar (Rdererc- 151 Pr~ajar E-E B-L-1 E-N-2 B-0 EMA1 BN3 Fora-rrilde pxzs, vales, ard vesses ofsinhiardesig serdc%
4) ardftranay am d the m~illOe orrpmwts shal be selede
2) Rf. Table M& D2-01, Exam Catepy B-I, PvRgam (B) Noe 2 Page 2 of 5

SI RFO#1 7 Table I Salem Nuclear Generating Station, Unit 1 ISI Program Long Term Plan IWE / IWL Examination Summary for the First Interval ASEM 1998 Code Edition 1998 Addenda I PFRIO1 I PFRIOD2 I O PFRaM Notes

1) Inacessible axzrxp utsWI be waTired shen acoessble.

Pagle 3 of 5

SI RFO#1 7 TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Item Item Flaw Flaw or Relevant Condition Found:

Category Number Description Characterization During Scheduled Section Xl Examination or Test (Yes or No)

DURING SALEM I RFO #17 THERE WERE NO ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Page 4of5

SIRFO#17 ABSTRACT OF REPAIRS, REPLACEMENTS, OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE Salem Unit 1 Nuclear Generating Station (For the period 06/03/2004 TO 11/06/2005)

TABLE 3 Abstract Of Repairs, Replacements, Or Corrective Measures Required For Continued Service Flaw or Relevant Condition Found Repair During Scheduled Repair

.eplacement, oeaiun Al ReO aceIent Code or Corrective Item Examination or Date Plan Number Class Measure Description Description of work Test (Yes or No) Complete RR Plan Evaluation 2 Replacement Instrument tubing for Replacement of No 118/05 60047225 70040527 SICVC-1P1142F Instrument Tubing 3 Replacement Pipe Support Replacement of Support NO OPEN 60020995 70043281 MSWG-34 bolting 3 Replacement Instrument tubing for Replacement of NO 2/18/05 60051577 70044362 SISW -12SW388 Instrument Tubing 3 Replacement Piping between 12SW405 Replacement of 1" pipe NO 7/28105 60056150 70048715 and RI3B 3 Replacement Tubing weld to 1p1747 Replacement of NO 9114104 60046473 70040161 gauge Instrument Tubing 2 Replacement 11 RHR Replacement of Bolting NO 9/14/04 *60031566 70029088 Heat Exchanger Materials SI RHG-I RHE3

  • This order is now closed and had been listed as open on the 1R16 OAR list.

Page 5of5