Text
Page 1 of 1 Table 06B. Groundwater Analytical Results for Well AC, PSEG Nuclear, LLC, Salem Generating Station, Hancocks Bridge, New Jersey 1/17/2014 2/19/2014 3/14/2014 Strontium - 89
<1.51 Strontium - 90
<0.799 Beryllium - 7
<21.7 Potassium - 40 41.30 Manganese - 54
<1.72 Cobalt - 58
<2.13 Iron - 59
<5.46 Cobalt - 60
<1.67 Zinc - 65
<3.58 Niobium - 95
<2.21 Zirconium - 95
<3.65 Iodine - 131
<32.3 Cesium - 134
<1.57 Cesium - 137
<1.75 Barium - 140
<36.3 Lanthanum - 140
<11.7 Americium - 241
<12.3 Americium-2 43
<0.0331 Curium - 242
<0.0607 Curium - 243/244
<0.0351 Plutonium - 238
<0.115 Plutonium - 239/240 (AS)
<0.0693 Plutonium - 241
<10.7 Notes:
Reporting period: First Quarter 2014 pCi/L All results reported in picocuries per liter Sample not collected Compound/analyte not detected above indicated minimum detectable concentration (MDC)
Sample Date Hard-to-Detect, Transuranic, and Gamma Radiological Isotopes