Well AA-V Installation Report - Table 3 Well AA-V Extended Purge Salem Chemistry Screening Results
ML14316A403
Person / Time
Site: Salem  PSEG icon.png
Issue date: 03/31/2014
From:
ARCADIS U.S.
To:
Office of Nuclear Reactor Regulation, Public Service Enterprise Group
Shared Package
ML14316A124 List:
References
LR-E14-0148
Download: ML14316A403 (1)


Text

Table 3 Well AA-V Extended Purge Salem Chemistry Screening Results.xls 1 of 1 Table 3: Well AA-V Extended Purge Salem Chemistry Screening Results Well AA-V Installation Report PSEG Nuclear, LLC, Salem Generating Station, Hancocks Bridge, New Jersey Tank Number Tritium Concentration (pCi/L)

Tank 1 12,900 Tank 2 18,500 Tank 3 14,700 Tank 4 12,200 Tank 5 15,200 Tank 6 11,500 Tank 7 11,300 Notes: