Table 08. Unit 2 Seismic Gap Drain Tritium Analytical Results, PSEG Nuclear, LLC, Salem Generating Station Date of Operation Tritium Results (pCi/L)
Date of Operation Tritium Results (pCi/L)
June 10, 2004 12,200 March 9, 2007 52,300 June 14, 2004 15,300 March 11, 2007 51,200 July 9, 2004 26,000 April 15, 2007 91,100 August 6, 2004 35,900 April 20, 2007 37,500 August 11, 2004 95,900 May 6, 2007 27,500 August 30, 2004 22,100 May 13, 2007 230,000 October 1, 2004 22,500 June 1, 2007 36,800 October 27, 2004 640,000 June 10, 2007 16,200 November 23, 2004 23,700 June 17, 2007 NA December 21, 2004 6,080 June 21, 2007 NA January 21, 2005 11,400 June 24, 2007 11,000 February 18, 2005 15,600 July 6, 2007 NA March 18, 2005 19,700 July 22, 2007 NA April 1, 2005 23,100 July 24, 2007 NA April 16, 2005 19,400 August 5, 2007 NA May 18, 2005 22,500 August 12, 2007 NA June 9, 2005 30,200 August 15, 2007 11,600 July 8, 2005 23,100 August 19, 2007 NA September 2, 2005 13,800 August 26, 2007 315,000 September 23, 2005 17,900 September 9, 2007 NA November 28, 2005 55,700 September 16, 2007 NA December 26, 2005 111,000 September 26, 2007 NA January 4, 2006 25,200 October 7, 2007 NA January 23, 2006 477,000 October 14, 2007 NA February 20, 2006 204,000 October 21, 2007 NA March 20, 2006 20,400 November 4, 2007 NA March 27, 2006 24,500 November 11, 2007 NA April 3, 2006 592,000 November 30, 2007 50,900 April 10, 2006 30,600 December 9, 2007 NA April 17, 2006 138,000 December 16, 2007 NA April 23,2006 19,700 December 23, 2007 36,200 May 1, 2006 19,700 January 7, 2008 61,700 May 6, 2006 18,600 January 13, 2008 NA May 14, 2006 16,100 January 20, 2008 100,000 May 20, 2006 113,000 February 3, 2008 170,000 May 27, 2006 11,700 February 10, 2008 43,800 June 4, 2006 21,800 February 17, 2008 NA June 12, 2006 343,000 February 20, 2008 69,200 June 18, 2006 25,200 February 23, 2008 47,700 June 24, 2006 15,900 March 2, 2008 NA June 30, 2006 23,600 March 9, 2008 85,600 July 2, 2006 44,100 March 16, 2008 50,300 July 9, 2006 126,000 March 23, 2008 229,000 July 15, 2006 16,700 March 30, 2008 26,600 July 22, 2006 176,000 April 6, 2008 42,200 July 29, 2006 688,000 April 13, 2008 61,700 August 5, 2006 6,910 April 20, 2008 43,400 August 12, 2006 6,760 April 27, 2008 102,000 August 19, 2006 9,910 May 4, 2008 403,000 August 26, 2006 26,900 May 11, 2008 692,000 September 3, 2006 98,600 May 14, 2008 40,700 September 10, 2006 12,000 May 19, 2008 629,000 September 17, 2006 10,700 May 25, 2008 255,000 September 23, 2006 7,550 May 28, 2008 29,600 September 30, 2006 8,560 June 1, 2008 222,000 October 7, 2006 9,760 June 10, 2008 17,300 October 16, 2006 40,100 June 15, 2008 553,000 October 23, 2006 84,800 June 22, 2008 238,000 October 30, 2006 35,900 June 29, 2008 192,000 November 4, 2006 39,800 July 6, 2008 NA November 11, 2006 51,800 July 13, 2008 NA November 19, 2006 126,000 July 20, 2008 11,000 November 25, 2006 64,400 July 27, 2008 52,100 December 2, 2006 29,100 August 3, 2008 NA December 9, 2006 31,700 August 10, 2008 15,600 December 17, 2006 25,200 August 16, 2008 24,000 December 23, 2006 33,200 August 24, 2008 889,000 December 31, 2006 34,100 August 31, 2008 NA January 6, 2007 41,000 September 7, 2008 NA January 14, 2007 70,400 September 14, 2008 NA January 21, 2007 208,000 September 21, 2008 NA January 27, 2007 30,800 September 28, 2008 NA February 3, 2007 36,000 October 5, 2008 NA February 11, 2007 31,200 October 12, 2008 NA February 17, 2007 40,500 October 19, 2008 NA February 24, 2007 44,600 October 26, 2008 NA March 3, 2007 67,000 November 2, 2008 NA March 5, 2007 39,200 November 9, 2008 NA March 6, 2007 38,600 November 16, 2008 NA March 7, 2007 40,800 November 23, 2008 NA March 8, 2007 28,200 November 30, 2008 NA Notes:
pCi/L = Picocuries per liter NA = Data not available Page 1 of 3
Table 08. Unit 2 Seismic Gap Drain Tritium Analytical Results, PSEG Nuclear, LLC, Salem Generating Station Date of Operation Tritium Results (pCi/L)
Date of Operation Tritium Results (pCi/L)
December 10, 2008 26,000 May 16, 2010 32,900 December 14, 2008 34,500 May 23, 2010 33,900 December 23, 2008 89,600 May 30, 2010 28,100 December 28, 2008 33,600 June 6, 2010 29,100 January 4, 2009 26,000 June 13, 2010 150,000 January 11, 2009 34,700 June 27, 2010 32,400 January 18, 2009 38,700 July 4, 2010 25,800 January 25, 2009 39,800 July 11, 2010 30,500 January 31, 2009 31,700 July 18, 2010 27,900 February 8, 2009 NA July 25, 2010 18,900 February 10, 2009 31,700 August 1, 2010 18,500 February 16, 2009 30,200 August 8, 2010 22,700 February 22, 2009 37,200 August 15, 2010 658,000 March 1, 2009 33,000 August 29, 2010 25,200 March 8, 2009 33,500 September 4, 2010 33,300 March 14, 2009 32,300 September 5, 2010 NA March 22, 2009 41,100 September 12, 2010 399,000 March 30, 2009 27,900 September 19, 2010 26,400 April 4, 2009 27,600 September 27, 2010 24,300 April 12, 2009 283,000 October 3, 2010 191,000 April 14, 2009 26,600 October 10, 2010 40,400 April 19, 2009 126,000 October 17, 2010 17,700 April 26, 2009 38,700 October 24, 2010 21,000 May 2, 2009 14,900 October 31, 2010 994,000 May 10, 2009 15,800 November 7, 2010 2,410,000 May 17, 2009 354,000 November 14, 2010 33,800 May 31, 2009 64,100 November 21, 2010 NA June 7, 2009 56,500 November 28, 2010 28,400 June 14, 2009 16,100 December 5, 2010 31,200 June 20, 2009 13,100 December 11, 2010 29,300 June 28, 2009 118,000 December 12, 2010 NA July 5, 2009 16,800 December 19, 2010 603,000 July 12, 2009 8,560 December 25, 2010 316,000 July 19, 2009 9,160 January 1, 2011 39,500 July 25, 2009 5,260 January 16, 2011 42,600 August 2, 2009 7,060 January 23, 2011 839,000 August 9, 2009 12,900 January 30, 2011 141,000 August 16, 2009 78,500 February 6, 2011 78,500 August 23, 2009 48,900 February 13, 2011 39,000 August 30, 2009 9,760 February 18, 2011 21,600 September 5, 2009 7,660 February 26, 2011 36,800 September 13, 2009 16,500 March 13, 2011 132,000 September 19, 2009 6,010 March 20, 2011 3,660,000 September 27, 2009 19,400 March 27, 2011 1,000,000 October 4, 2009 14,900 April 3, 2011 34,200 October 12, 2009 12,300 April 9, 2011 35,000 October 18, 2009 16,700 April 17, 2011 20,000 October 25, 2009 42,000 April 24, 2011 70,700 November 1, 2009 56,800 May 8, 2011 53,600 November 8, 2009 41,600 May 15, 2011 66,400 November 22, 2009 44,100 June 5, 2011 74,500 November 29, 2009 31,500 June 26, 2011 79,400 December 5, 2009 NA July 3, 2011 85,700 December 13, 2009 NA July 10, 2011 NA December 20, 2009 53,600 August 7, 2011 72,500 December 26, 2009 37,500 September 4, 2011 432,000 January 3, 2010 51,800 September 11, 2011 66,500 January 10, 2010 60,500 October 2, 2011 70,900 January 17, 2010 272,000 October 16, 2011 959,000 January 25, 2010 156,000 October 30, 2011 NA January 31, 2010 509,000 November 6, 2011 61,900 February 7, 2010 970,000 December 4, 2011 60,500 February 14, 2010 38,900 January 30, 2012 52,400 February 20, 2010 38,400 February 5, 2012 74,000 February 28, 2010 50,500 March 4, 2012 61,700 March 7, 2010 220,000 April 1, 2012 62,500 March 14, 2010 70,100 May 12, 2012 568,000 March 21, 2010 298,000 June 3, 2012 47,300 March 28, 2010 32,400 July 1, 2012 44,300 April 4, 2010 574,000 August 5, 2012 44,900 April 7, 2010 59,800 September 2, 2012 41,900 April 9, 2010 32,100 October 6, 2012 46,100 April 18, 2010 41,700 November 4, 2012 37,700 April 25, 2010 38,700 December 2, 2012 44,900 May 2, 2010 32,600 January 4, 2013 43,100 May 9, 2010 36,500 February 2, 2013 36,000 May 16, 2010 32,900 March 3, 2013 484,000 Notes:
pCi/L = Picocuries per liter NA = Data not available Beginning in December 2011, Unit 2 Seismic Gap Drain Tritium analytical samples were collected on a monthly basis.
Page 2 of 3
Table 08. Unit 2 Seismic Gap Drain Tritium Analytical Results, PSEG Nuclear, LLC, Salem Generating Station Date of Operation Tritium Results (pCi/L)
Date of Operation Tritium Results (pCi/L)
April 7, 2013 270,000 November 3, 2013 726,000 May 5, 2013 37,200 November 8, 2013 105,000 June 5, 2013 861,000 December 1, 2013 51,100 July 7, 2013 34,500 January 5, 2014 163,000 August 9, 2013 765,000 February 2, 2014 70,300 September 1, 2013 114,000 March 2, 2014 43,400 October 12, 2013 763,000 Notes:
pCi/L = Picocuries per liter NA = Data not available An additional sample was collected in November as a confirmation sample for the November 3, 2013 analytical result.