Date of Operation Tritium Results (pCi/L)
Date of Operation Tritium Results (pCi/L)
March 29, 2004 32,300,000 August 20, 2006 80,100,000 April 15, 2004 24,500,000 August 26, 2006 90,300,000 May 13, 2004 7,820,000 September 10, 2006 78,500,000 May 18, 2004 10,200,000 September 17, 2006 123,000,000 May 27, 2004 21,800,000 September 25, 2006 121,000,000 June 9, 2004 44,300,000 September 30, 2006 118,000,000 June 16, 2004 32,200,000 October 7, 2006 128,000,000 June 23, 2004 15,600,000 October 14, 2006 133,000,000 June 30, 2004 79,100,000 October 21, 2006 116,000,000 July 7, 2004 58,700,000 October 28, 2006 84,000,000 July 13, 2004 41,700,000 November 4, 2006 113,000,000 July 28, 2004 34,800,000 November 11, 2006 100,000,000 August 5, 2004 31,700,000 November 19, 2006 97,200,000 August 11, 2004 38,500,000 November 25, 2006 116,000,000 August 18, 2004 52,600,000 December 2, 2006 122,000,000 August 25, 2004 70,800,000 December 9, 2006 110,000,000 August 31, 2004 60,300,000 December 17, 2006 100,000,000 September 14, 2004 46,500,000 December 23, 2006 115,000,000 September 21, 2004 63,700,000 December 31, 2006 134,000,000 September 28, 2004 42,900,000 January 6, 2007 131,000,000 October 5, 2004 2,590,000 January 14, 2007 105,000,000 October 13, 2004 74,600,000 January 21, 2007 102,000,000 October 21, 2004 75,600,000 January 27, 2007 77,900,000 October 27, 2004 1,920,000 February 3, 2007 71,800,000 November 3, 2004 66,300,000 February 11, 2007 67,700,000 November 8, 2004 103,000,000 February 17, 2007 67,400,000 November 15, 2004 61,900,000 February 24, 2007 66,400,000 November 23, 2004 46,800,000 March 3, 2007 76,000,000 December 1, 2004 40,400,000 March 5, 2007 76,000,000 December 8, 2004 63,400,000 March 6, 2007 2,540,000 December 14, 2004 44,800,000 March 11, 2007 75,600,000 December 21, 2004 89,900,000 March 25, 2007 75,800,000 January 4, 2005 13,600,000 April 15, 2007 69,900,000 January 11, 2005 40,900,000 April 20, 2007 1,770,000 January 19, 2005 17,700,000 May 1, 2007 58,600,000 January 24, 2005 57,900,000 May 6, 2007 79,100,000 February 2, 2005 55,850,000 May 11, 2007 80,900,000 February 9, 2005 53,800,000 May 13, 2007 77,100,000 February 25, 2005 26,800,000 May 14, 2007 82,400,000 February 28, 2005 59,400,000 May 15, 2007 82,300,000 March 9, 2005 31,800,000 May 16, 2007 82,600,000 March 18, 2005 44,200,000 May 18, 2007 82,900,000 April 1, 2005 39,300,000 May 21, 2007 89,700,000 April 13, 2005 34,600,000 May 23, 2007 84,500,000 April 21, 2005 29,900,000 June 1, 2007 65,700,000 May 11, 2005 25,600,000 June 7, 2007 74,500,000 May 19, 2005 33,400,000 June 10, 2007 66,600,000 May 25, 2005 37,400,000 June 17, 2007 63,200,000 June 9, 2005 35,800,000 June 19, 2007 72,000,000 July 8, 2005 31,800,000 June 21, 2007 70,200,000 July 15, 2005 47,900,000 June 24, 2007 73,900,000 September 4, 2005 32,600,000 June 26, 2007 81,400,000 September 28, 2005 50,300,000 July 6, 2007 39,000,000 November 27, 2005 29,700,000 July 8, 2007 1,970,000 December 26, 2005 27,800,000 July 11, 2007 66,200,000 January 23, 2006 20,500,000 July 19, 2007 60,400,000 February 19, 2006 483,000 July 24, 2007 57,300,000 March 13, 2006 19,300,000 July 29, 2007 12,800,000 March 20, 2006 26,700,000 August 5, 2007 61,500,000 March 27, 2006 36,700,000 August 12, 2007 66,600,000 April 3, 2006 35,400,000 August 15, 2007 71,400,000 April 10, 2006 58,400,000 August 21, 2007 76,400,000 April 17, 2006 57,200,000 August 26, 2007 66,300,000 April 23, 2006 70,300,000 September 6, 2007 88,200,000 May 1, 2006 74,600,000 September 9, 2007 87,000,000 May 7, 2006 88,000,000 September 16, 2007 89,000,000 May 14, 2006 85,800,000 September 26, 2007 103,000,000 May 20, 2006 83,800,000 September 27, 2007 96,000,000 May 27, 2006 6,970,000 October 7, 2007 94,600,000 June 4, 2006 73,600,000 October 10, 2007 104,000,000 June 12, 2006 73,100,000 October 14, 2007 98,200,000 June 18, 2006 58,400,000 October 21, 2007 119,000,000 June 24, 2006 72,400,000 October 24, 2007 107,000,000 June 29, 2006 63,200,000 November 1, 2007 100,000,000 July 2, 2006 47,400,000 November 4, 2007 97,400,000 July 9, 2006 34,600,000 November 11, 2007 102,000,000 July 16, 2006 30,000,000 November 18, 2007 4,800,000 July 22, 2006 63,200,000 November 30, 2007 99,000,000 July 29, 2006 36,300,000 December 9, 2007 124,000,000 August 5, 2006 45,800,000 December 16, 2007 107,000,000 August 12, 2006 68,600,000 December 23, 2007 40,500,000 Notes:
pCi/L = Picocuries per liter Table 07. Unit 1 Seismic Gap Drain Tritium Analytical Results, PSEG Nuclear, LLC, Salem Generating Station, Hancocks Bridge, New Jersey.
Page 1 of 3
Table 07. Unit 1 Seismic Gap Drain Tritium Analytical Results, PSEG Nuclear, LLC, Salem Generating Station, Hancocks Bridge, New Jersey.
Date of Operation Tritium Results (pCi/L)
Date of Operation Tritium Results (pCi/L)
January 6, 2008 107,000,000 October 18, 2009 76,500,000 January 13, 2008 70,900,000 October 25, 2009 135,000,000 January 20, 2008 104,000,000 November 1, 2009 115,000,000 February 3, 2008 139,000,000 November 8, 2009 147,000,000 February 10, 2008 509,000 November 15, 2009 147,000,000 February 20, 2008 144,000,000 November 22, 2009 164,000,000 February 24, 2008 142,000,000 November 29, 2009 156,000,000 March 2, 2008 149,000,000 December 5, 2009 158,000,000 March 9, 2008 142,000,000 December 13, 2009 748,000 March 16, 2008 169,000,000 December 20, 2009 142,000,000 March 23, 2008 178,000,000 December 26, 2009 48,200,000 March 30, 2008 164,000,000 January 3, 2010 81,100,000 April 6, 2008 181,000,000 January 10, 2010 113,000,000 April 13, 2008 170,000,000 January 17, 2010 134,000,000 April 20, 2008 183,000,000 January 24, 2010 93,200,000 April 27, 2008 5,860,000 January 31, 2010 75,300,000 May 4, 2008 169,000,000 February 7, 2010 72,400,000 May 11, 2008 159,000,000 February 14, 2010 28,600,000 May 19, 2008 154,000,000 February 20, 2010 19,600,000 May 25, 2008 82,000,000 February 28, 2010 47,100,000 June 1, 2008 145,000,000 March 7, 2010 118,000,000 June 10, 2008 150,000,000 March 14, 2010 76,600,000 June 15, 2008 110,000,000 March 21, 2010 77,600,000 June 22, 2008 168,000,000 March 28, 2010 63,000,000 June 29, 2008 191,000,000 April 4, 2010 144,000,000 July 6, 2008 231,000,000 April 9, 2010 37,400,000 July 20, 2008 212,000,000 April 18, 2010 72,400,000 July 27, 2008 212,000,000 April 25, 2010 47,400,000 August 3, 2008 209,000,000 May 2, 2010 81,800,000 August 10, 2008 165,000,000 May 9, 2010 82,600,000 August 16, 2008 221,000,000 May 16, 2010 986,000 August 24, 2008 229,000,000 May 22, 2010 119,000,000 August 31, 2008 246,000,000 May 30, 2010 159,000,000 September 14, 2008 250,000,000 June 6, 2010 129,000,000 September 21, 2008 246,000,000 June 13, 2010 179,000,000 October 27, 2008 200,000,000 June 20, 2010 149,000,000 November 2, 2008 238,000,000 June 27, 2010 185,000,000 December 6, 2008 172,000,000 July 4, 2010 147,000,000 December 14, 2008 186,000,000 July 11, 2010 156,000,000 December 21, 2008 181,000,000 July 18, 2010 184,000,000 December 27, 2008 202,000,000 July 25, 2010 143,000,000 January 4, 2009 143,000,000 August 1, 2010 165,000,000 January 11, 2009 166,000,000 August 8, 2010 148,000,000 January 17, 2009 164,000,000 August 15, 2010 165,000,000 January 25, 2009 171,000,000 August 29, 2010 165,000,000 February 1, 2009 172,000,000 September 4, 2010 164,000,000 February 10, 2009 163,000,000 September 12, 2010 195,000,000 February 15, 2009 160,000,000 September 19, 2010 189,000,000 February 22, 2009 176,000,000 September 27, 2010 161,000,000 March 1, 2009 184,000,000 October 3, 2010 152,000,000 March 8, 2009 168,000,000 October 10, 2010 150,000,000 March 14, 2009 190,000,000 October 16, 2010 153,000,000 March 22, 2009 189,000,000 October 24, 2010 186,000,000 March 30, 2009 188,000,000 October 31, 2010 222,000,000 April 4, 2009 200,000,000 November 7, 2010 103,000,000 April 12, 2009 190,000,000 November 14, 2010 131,000,000 April 19, 2009 180,000,000 November 21, 2010 206,000,000 April 26, 2009 168,000,000 November 28, 2010 157,000,000 May 2, 2009 5,980,000 December 5, 2010 164,000,000 May 10, 2009 166,000,000 December 11, 2010 53,100,000 May 17, 2009 165,000,000 December 19, 2010 209,000,000 May 24, 2009 143,000,000 December 25, 2010 220,000,000 May 31, 2009 164,000,000 January 1, 2011 215,000,000 June 7, 2009 176,000,000 January 16, 2011 222,000,000 June 14, 2009 167,000,000 January 23, 2011 196,000,000 June 20, 2009 151,000,000 January 30, 2011 128,000,000 June 28, 2009 124,000,000 February 6, 2011 135,000,000 July 5, 2009 167,000,000 February 13, 2011 127,000,000 July 12, 2009 189,000,000 February 18, 2011 126,000,000 July 19, 2009 218,000,000 March 13, 2011 146,000,000 July 25, 2009 91,400,000 March 20, 2011 147,000,000 August 2, 2009 22,600,000 March 27, 2011 133,000,000 August 9, 2009 62,100,000 April 3, 2011 150,000,000 August 16, 2009 50,000,000 April 17, 2011 140,000,000 August 23, 2009 21,500,000 April 24, 2011 131,000,000 August 30, 2009 45,800,000 May 15, 2011 172,000,000 September 5, 2009 73,800,000 June 5, 2011 181,000,000 September 13, 2009 56,400,000 June 26, 2011 143,000,000 September 19, 2009 79,000,000 July 3, 2011 155,000,000 September 27, 2009 87,600,000 August 7, 2011 172,000,000 October 4, 2009 98,900,000 September 4, 2011 137,000,000 October 12, 2009 98,000,000 September 11, 2011 125,000,000 Notes:
pCi/L = Picocuries per liter Page 2 of 3
Table 07. Unit 1 Seismic Gap Drain Tritium Analytical Results, PSEG Nuclear, LLC, Salem Generating Station, Hancocks Bridge, New Jersey.
Date of Operation Tritium Results (pCi/L)
Date of Operation Tritium Results (pCi/L)
October 2, 2011 157,000,000 January 4, 2013 29,200,000 October 16, 2011 177,000,000 February 2, 2013 73,000,000 November 6, 2011 49,000,000 March 3, 2013 52,700,000 December 4, 2011 83,500,000 April 7, 2013 101,000,000 January 30, 2012 1,830,000 May 5, 2013 38,500,000 February 5, 2012 48,000,000 June 5, 2013 44,300,000 February 12, 2012 1,650,000 July 7, 2013 11,400,000 March 4, 2012 58,900,000 August 9, 2013 70,500,000 April 1, 2012 9,660,000 September 1, 2013 93,300,000 May 12, 2012 84,500,000 October 12, 2013 166,000,000 June 3, 2012 52,700,000 November 3, 2013 183,000,000 July 1, 2012 56,100,000 December 1, 2013 182,000,000 August 5, 2012 84,200,000 January 5, 2014 112,000,000 September 5, 2012 3,490,000 January 17, 2014 84,300,000 October 6, 2012 166,000,000 February 2, 2014 115,000,000 November 26, 2012 176,000,000 March 2, 2014 125,000,000 December 2, 2012 49,200,000 Notes:
pCi/L = Picocuries per liter Beginning in March 2012, Unit 1 Seismic Gap Drain Tritium analytical samples were collected on a monthly basis.
Page 3 of 3