w

.

.

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-454/86038(DRSS)

Docket No. 50-454 License No. NPF-37 Licensee:

Commonwealth Edison Company Post Office Box 767 Chicago, IL 60690 Facility Name:

Byron Nuclear Power Station, Unit 1 Inspection Conducted:

September 22-25, 1986 Date of Last Physical Security Inspection:

September 16-19, 1985 Type of Inspec ion r outine, Unannounced Physical Security Inspection

/o/20/4(,

Inspector:

%%

Bd-Grbuiti Date /

/

Physical Security Inspector Approved By: Obu8

/ 8/ #

(f. R. Creed, Chief Date Safeguards Section Inspection Summary Inspection on September 22-25, 1986 (Report No. 50-454/86038(DRSS))

Areas Inspected:

Included a review of Security Plan and Implementing Procedures; Management Effectiveness; Security Organization; Records and Reports; Testing and Maintenance; Locks, Keys and Combinations; Protected Area Barriers; Security Lighting; Compensatory Measures; Assessment Aids; Access Control - Personnel and Packages; Detection Aids - Protected Areas; Personnel Training and Qualification and Licensee action on previous inspection findings.

Inspection effort was expended on the backshift to evaluate the Closed Circuit Television System and security lighting.

Results:

The licensee was found to be in compliance with NRC requirements within the areas examined during the inspection.

Two previous inspection findings involving the degradation of a security barrier and the inadequate reporting of a security event were closed, while a previous inspection finding pertaining to the security computer system remains open.

Two new findings relating to security lighting and assessment aids were identified during this inspection.

(Details - UNCLASSIFIED )

Nok o$$ $so!$ks4 Enclosure contains G

PDR SAFECUARDS INFC D TION Upon scparctica this p;c is DecontroHei