SUBJECT:
BYRON STATION - INTEGRATED INSPECTION REPORT 05000454/2024001; 05000455/2024001 AND 07200068/2024001
Dear David Rhoades:
On March 31, 2024, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Byron Station. On April 12, 2024, the NRC inspectors discussed the results of this inspection with H. Welt, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.
No findings or violations of more than minor significance were identified during this inspection.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Richard A. Skokowski, Chief Reactor Projects Branch 3 Division of Operating Reactor Safety Docket Nos. 05000454; 05000455 and 07200068 License Nos. NPF-37 and NPF-66
Enclosure:
As stated
Inspection Report
Docket Numbers:
05000454; 05000455 and 07200068
License Numbers:
Report Numbers:
05000454/2024001; 05000455/2024001 and 07200068/2024001
Enterprise Identifier:
I-2024-001-0068 and 1-2024-001-0101
Licensee:
Constellation Energy Generation, LLC
Facility:
Byron Station
Location:
Byron, IL
Inspection Dates:
January 01, 2024 to March 31, 2024
Inspectors:
A. Demeter, Resident Inspector
R. Elliott, Senior Project Engineer
R. Knutson, Illinois Emergency Management Agency
M. Learn, Team Leader
J. Robbins, Senior Resident Inspector
D. Sargis, Health Physicist
Approved By:
Richard A. Skokowski, Chief
Reactor Projects Branch 3
Division of Operating Reactor Safety
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an integrated inspection at Byron Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
No findings or violations of more than minor significance were identified.
Additional Tracking Items
None.
PLANT STATUS
Unit 1 operated at or near rated thermal power for the entire inspection period.
Unit 2 operated at or near rated thermal power for the entire inspection period.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed activities described in IMC 2515, Appendix D, Plant Status, observed risk-significant activities, and completed on-site portions of IPs. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.01 - Adverse Weather Protection
Impending Severe Weather Sample (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated the adequacy of the overall preparations to protect risk-significant systems from impending severe weather during a winter storm watch and extreme cold weather during the week ending January 13, 2024.
71111.04 - Equipment Alignment
Partial Walkdown Sample (IP Section 03.01) (3 Samples)
The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:
- (1) Partial Walkdown of the Unit 1 "A" Train Safety Injection (SI) and Residual Heat Removal Systems prior to a scheduled "B" Train SI work window on February 12, 2024.
- (2) Partial Walkdown of the 1A, 1B, and 2B Diesel Generators (DG) following vent fan failure of the 2A DG on February 1, 2024.
- (3) Partial Walkdown of Unit 0 and Unit 2 Component Cooling (CC) Systems during a Unit 1 CC Heat Exchanger Work window, as documented in Work Order (WO)
===5284272 on March 8, 2024.
71111.05 - Fire Protection
Fire Area Walkdown and Inspection Sample (IP Section 03.01)===
The inspectors evaluated the implementation of the fire protection program by conducting a walkdown and performing a review to verify program compliance, equipment functionality, material condition, and operational readiness of the following fire areas:
- (1) Fire Zone 5.2-2, Unit 2, Auxiliary Building 426' Elevation, Division 21 ESF Switchgear Room on January 24, 2024.
- (2) Fire Zone 8.3-1, Unit 1 Turbine Building 401'-0" Elevation, following spurious actuation of suppression zone 1S-23, as documented in Issue Report (IR) 4725659 on January 2, 2024.
- (3) Fire Zone 12.1-0, Fuel Handling Building 426' and 401' Elevations, following concerns over improperly breached fire seals, as documented in IR 4722396 on January 10, 2024.
- (4) Fire Zone 9.1-1 and 9.4-1, Auxiliary Building 401'-0" Elevation, 1B Diesel Generator &
Day Tank Room, following smoke coming from the starting air compressor, as documented in IR 4730725 on January 16, 2024.
- (5) Assessment of Diesel Generator Cable Tunnel Hatch 1DSH120 following identification of inadequate hatch sealing, as documented in IR 4704957 on January 25, 2024.
Fire Brigade Drill Performance Sample (IP Section 03.02) (1 Sample)
- (1) Observation and evaluation of the station's on shift fire brigade during an unannounced fire drill on March 19, 2024.
71111.06 - Flood Protection Measures
Flooding Sample (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated internal flooding mitigation protections in the:
- Unit 1, Turbine Building, 401' Elevation, the four quadrants of Fire Zone 8.3-1.
- Unit 1, Essential Service Water Pump Room, 330' Elevation, Fire Zone 11.1A-0.
- Unit 2, Essential Service Water Pump Room, 330' Elevation, Fire Zone 11.1B-0.
71111.07A - Heat Exchanger/Sink Performance
Annual Review (IP Section 03.01) (1 Sample)
The inspectors evaluated readiness and performance of:
- (1) Evaluation of the condition and performance of Unit 1, Train B, Safety Injection Pump Bearing Oil Cooler as documented in WO 5391301.
71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance
Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01) (1 Sample)
- (1) The inspectors observed and evaluated licensed operator performance in the control room during routine activities March 4 through March 7, 2024.
Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)
- (1) The inspectors observed and evaluated the performance of a complex casualty graded scenario by a crew of licensed plant operators in the facility's simulator on February 8, 2024.
71111.12 - Maintenance Effectiveness
Maintenance Effectiveness (IP Section 03.01) (3 Samples)
The inspectors evaluated the effectiveness of maintenance to ensure the following structures, systems, and components (SSCs) remain capable of performing their intended function:
- (1) Review of the station's periodic evaluation of effectiveness of maintenance activities per 10 CFR 50.65(a)(3).
- (2) Review of the station's treatment of Maintenance and Test Equipment (M&TE)calibration failures over the previous 24-months.
- (3) Review of the station's maintenance strategy for replacing Main Steam Power Operated Relief Valve controllers.
71111.13 - Maintenance Risk Assessments and Emergent Work Control
Risk Assessment and Management Sample (IP Section 03.01) (5 Samples)
The inspectors evaluated the accuracy and completeness of risk assessments for the following planned and emergent work activities to ensure configuration changes and appropriate work controls were addressed:
- (1) Review and evaluation of the risk associated with the replacement of 2PS-DG098A on the 2A Diesel Generator following a failure to start, as documented in IR 4727211 on January 4, 2024.
- (2) Review of the station's B2R24 TS 3.0.4.b Evaluation - Mode Change with Technical Specification Equipment Out of Service on January 11, 2024.
- (3) Verification of select risk mitigating actions implemented in the plant during emergent work on the 2A Diesel Generator on January 31, 2024.
- (4) Review and evaluation of the risk associated with removing and replacing the 1B Diesel Generator Starting Air Compressor, as documented in WO 5443933 on March 12, 2024.
- (5) Review and evaluation of the risk associated with the loading of spent fuel into the Dry Cask Storage (DCS) system throughout several weeks of the campaign, as documented in WO 5332871.
71111.15 - Operability Determinations and Functionality Assessments
Operability Determination or Functionality Assessment (IP Section 03.01) (8 Samples)
The inspectors evaluated the licensee's justifications and actions associated with the following operability determinations and functionality assessments:
- (1) Evaluation of the operability of 2PS9356B and its impact on containment based on failing the local leak rate test, as documented in IR 4710010 on January 26, 2024.
- (2) Evaluation of the operability of the 1B Containment Spray Pump following identification of observable indications during NDE (Nondestructive Examination)exams, as documented in IR 4703543 on January 10, 2024.
- (3) Evaluation of the operability of the 2A Diesel Generator following vent fan trip on high differential pressure, as documented in IR 4739551 on February 22, 2024.
- (4) Evaluation of the operability of 1AF049D as documented in IR 4706401 on March 6, 2024.
- (5) Evaluation of the operability of motor operated valve (MOV) 1SI8812B following discovery of issues with a mounting bolt, as documented in IR 4689931 on March 6, 2024.
- (6) Evaluation of the operability of the 2A Auxiliary Feedwater Pump following discovery of high oil viscosity, as documented in IR 4752721 on March 14, 2024.
- (7) Evaluation of the operability of 0A Essential Service Water Makeup Pump following discovery of severe coating degradation on the gear oil cooler, as documented in IR 4761004 on March 29, 2024.
- (8) Evaluation of the operability of the limit switch control scheme of various essential service water valves, as documented in IR 4540295 on March 29, 2024.
71111.18 - Plant Modifications
Temporary Modifications and/or Permanent Modifications (IP Section 03.01 and/or 03.02) (2 Samples)
The inspectors evaluated the following temporary or permanent modifications:
- (1) Review of temporary plant modification per Engineering Changes (EC) 634666, Lift Lead on SAT 242-2 PD-Guard to Eliminate Nuisance Alarm.
- (2) Review of temporary/permanent plant modification per EC 640554: TCCP (Temporary Configuration Change Package) for U2 Train A Sensor #8 RVLIS Leads Lifted.
71111.24 - Testing and Maintenance of Equipment Important to Risk
The inspectors evaluated the following testing and maintenance activities to verify system operability and/or functionality:
Post-Maintenance Testing (PMT) (IP Section 03.01) (7 Samples)
- (1) Functional and operational testing of 2A Essential Service Water Pump Cubicle Cooler following a scheduled work window, as documented in WO 4945433 on February 1, 2024.
- (2) Functional and operational testing of 0VV23C and Technical Support Center ventilation following identification of an acrid odor, as documented in IR 4748769 on February 15, 2024.
- (3) Functional and operational testing of the 1D Steam Generator Power Operated Relief Valve (PORV) following a work window, as documented in WO 5443249 on March 4, 2024.
- (4) Functional and operational testing of the 2B and 2C Pressurizer Heater Transformers following inspection and maintenance, as documented in multiple WOs on March 14, 2024.
- (5) Functional and operational testing of the 1B Essential Service Water Pump following a work window, as documented in WO 5359119 on March 20, 2024.
- (6) Functional and operational testing of 2B Component Cooling Pump following a work window, as documented in WO 5476077 on March 22, 2024.
- (7) Functional and operational testing of the 2A Residual Heat Removal pump following a work window, as documented in WO 5379461 on March 26, 2024.
Surveillance Testing (IP Section 03.01) (5 Samples)
(1)2BOSR 5.5.8.SI.5-1a, Inservice Testing of the 2A Safety Injection Pump, as documented in WO 5456687 on February 28, 2024.
(2)1&2 BOSR 0.5-2.AF.1-1, Surveillance Testing of Unit 1, and Unit 2 Auxiliary Feedwater Valves _AF005A-D, as documented in WOs 5426049 AND 5426050, on March 4, 2024.
(3)1BOSR 8.1.2-1, surveillance testing of the 1B Diesel Generator, as documented in WO 5475997 on February 29, 2024.
(4)0BOSR 7.10.1-1, Control Room Ventilation Train 0A Quarterly Surveillance, as documented in WO 5425042 on March 4, 2024.
(5)1BOSR 8.1.2-1 and 1BOSR DG-8A, surveillance testing of 1A Emergency Diesel Generator and Turbocharger Spin Down, as documented in WO 5380211 on March 28, 2024.
Inservice Testing (IST) (IP Section 03.01) (1 Sample)
(1)1BOSR 5.5.8.CS.5-2c, Inservice Testing of the 1B Containment Spray Pump, as documented in WO 5417950 on February 7, 2024.
Diverse and Flexible Coping Strategies (FLEX) Testing (IP Section 03.02) (1 Sample)
- (1) Review of Compensatory Actions related to the failure of the 0C High Head Flex Pump, as documented in IR 4717747 on February 21,
OTHER ACTIVITIES - BASELINE
===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:
IE01: Unplanned Scrams per 7000 Critical Hours Sample (IP Section 02.01)===
- (1) Unit 1 (January 1, 2023 through December 31, 2023)
- (2) Unit 2 (January 1, 2023 through December 31, 2023)
IE03: Unplanned Power Changes per 7000 Critical Hours Sample (IP Section 02.02) (2 Samples)
- (1) Unit 1 (January 1, 2023 through December 31, 2023)
- (2) Unit 2 (January 1, 2023 through December 31, 2023)
IE04: Unplanned Scrams with Complications (USwC) Sample (IP Section 02.03) (2 Samples)
- (1) Unit 1 (January 1, 2023 through December 31, 2023)
- (2) Unit 2 (January 1, 2023 through December 31, 2023)
71152A - Annual Follow-up Problem Identification and Resolution Annual Follow-up of Selected Issues (Section 03.03)
The inspectors reviewed the licensees implementation of its corrective action program related to the following issues:
- (1) The inspectors reviewed the issues identified in open IRs and WOs for Unit 1, Unit 2, and Unit 0 [common to both units], as documented the Control Room Deficiencies report generated January 29, 2024.
- (2) The inspectors reviewed the corrective actions associated with non-cited violation (NCV) 05000454(05000455)/2023012-01, Relief Valve Scope Testing, as documented in IR
OTHER ACTIVITIES
- TEMPORARY INSTRUCTIONS, INFREQUENT AND ABNORMAL
60855 - Operation Of An ISFSI Operation Of An ISFSI
- (1) The inspectors evaluated the licensees independent spent fuel storage installation (ISFSI) cask loading activities from March 11 through March 14, 2024. Specifically, the inspectors observed the following activities during the loading of multi-purpose canister (MPC) No. 952:
- heavy load movement of loaded MPC out of the spent fuel pool
- closure welding and nondestructive evaluations
- forced helium dehydration
- radiological field surveys
- heavy load lift into stack-up configuration
- downloading loaded MPC into overpack The inspectors performed walkdowns of the ISFSI pad and walkdowns of the ISFSI haul path.
The inspectors evaluated the following:
- spent fuel selected for loading into dry cask storage during this loading campaign
- selected corrective action program documents
- selected 10 CFR 72.48 screenings and evaluations
- changes to the site's 10 CFR 72.212 report since the previous inspection
INSPECTION RESULTS
Observation: Review of Corrective Actions for Non-Cited Violation 05000454(05000455)/2023012-01, Relief Valve Scope Testing 71152A The inspectors performed a detailed review of Issue Report (IR) 4712019, NCV 05000454(05000455)/2023012-01, Relief Valve Scope Testing. The IR was written in response to a green finding and associated non-cited violation (NCV) for the failure to comply with a procedure as written. The station determined the failure to complete a step in BMP 3100-23, IST Crosby Safety/Relief Valve Bench Testing, was contrary to the stations requirements of HU-AA-104-101, Procedure Use and Adherence (PUA), and contributed to the untimely scope expansion testing.
The inspectors concluded that the licensees actions taken in accordance with their correction action program were reasonable given the overall safety significance of the issue. Corrective Action Program (CAP) actions were focused on reinforcing the standards of PUA and work package close out within the Mechanical Maintenance Department (MMD) and revising procedures to remove the self-imposed expansion scope timeframe.
During the review of the IR, the inspectors identified additional minor issues with PUA or CAP closure documentation. These work products collaborated on by individuals from MMD, maintenance planning, programs engineering, regulatory assurance, and others, contained several issues pertaining to PUA and PI-AA-125, Corrective Action Program (CAP)
Procedure. The failure to complete documentation as required for one corrective action (CA)resulted in the CA being rejected during a subsequent monthly scheduled CA review, weeks after the CA was marked complete (Action Tracking Item (ATI)-11). Multiple gaps were identified in the Organizational Effectiveness Evaluation required per one CA (ATI-05),despite requiring review and approval by a senior leadership team member or designee.
Closure documentation for one CA was not retrievable by the inspectors nor Regulatory Assurance when requested (ATI-04).
Many CAs focus on PUA weaknesses, particularly within MMD. The extent of condition performed under the IR investigation reviewed similar procedures and valve performance analyses, but did not include aspects related to PUA, despite this being listed as a cause of the finding and NCV. While not necessarily prescriptive of a broader issue, the inspectors find it prudent to elucidate the gaps in PUA that occurred during the implementation of the CAs, as noted in our observations.
No findings or violations of NRC requirements of more than minor safety significance were identified by the inspectors in the course of this review.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On April 12, 2024, the inspectors presented the integrated inspection results to H. Welt, Site Vice President, and other members of the licensee staff.
- On March 15, 2024, the inspectors presented the 1Q2024 ISFSI Cask Loading Inspection results to S. Harvey, Plant Manager, and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Trend of Grid Strap Damage during DCS Inspections
07/27/2022
MPC Lift Stud Has A Defect on the Threads
11/08/2023
Debris Discovered on Fuel Assembly
2/20/2023
FM in MPC 0951
03/04/2024
Corrective Action
Documents
DCS HI-STORM Made Contact with Outer Train Shed Roll Up
Door
03/13/2024
NRC-MPC Lid Punch Mark Observation
03/13/2024
NRC-Cask Spacing on ISFSI Pad Observation
03/13/2024
Corrective Action
Documents
Resulting from
Inspection
NRC-Lift Yoke Paint Observation
03/13/2024
Drawings
Drawing 5490
Sheet 2
Dry Fuel Storage Project Cask Storage Pad Details
Byron Fuel Selection Packages and Alternate List for 2024
ISFSI Campaign
Engineering
Changes
ECO-5014-312
Foreign Material to Be Stored in MPC
HI-2125116
Thermal Evaluation of Cask Spacing on ISFSI at Exelon Sites
2/07/2012
Engineering
Evaluations
HI-2230448
Thermal Inertia Calculation for Braidwood and Byron
2.48-221
Review of CoC Holder ECOs, SMDRs, and the Associated
2.48 Reviews Related to the Casks to be Loaded in BYNPS
22 Spent Fuel Loading Campaign
2.48-222
Casks for the 2022 Spent Fuel Loading Campaign (Byron)
2.48-224
Holtec SMDR No. 1024-3004 for HI-STORM 100S Version B
Serial Nos. 100-1406 and 100-1407
2.48-226
2.48-235
HI-2230448 - Thermal Inertia Calculation for Braidwood and
Byron
2.48-236
Spent Fuel Casks and Fuel Selection Packages for the 2024
Spent Fuel Loading Campaign (Byron) - ISFSI
60855
Miscellaneous
NOSA-BYR-22-
Independent Spent Fuel Storage Installation Audit
06/10/2022
4003-R95-24-
007-03132024-
Helium Leak Test Report
03/13/2024
NDE Reports
20443-952-01
Root Layer Liquid Penetrant Examination Report
03/11/2024
BFP FH-69
HI-TRAC Movement within the Fuel Building
BFP FH-70
HI-TRAC Loading Operations
Control of Heavy Loads Program
OU-MW-671-300
MPC Processing
Procedures
HOLTEC HI-STORM Radiation Survey
Radiation
Surveys
23-199992
ISFSI Pad Annual Survey
08/29/2023
05332871-12
Obtain and Analyze Wet Cask Pit Boron Concentration
03/12/2024
MREQ 4725997-
Concrete Pad and HI-STORM Casks Integrity Inspection
2/21/2023
Overhead Crane Annual Mechanical Inspection
11/21/2023
60855
Work Orders
Lifting Device Inspection Per BHP FH-85
11/30/2023
4714678
2SH15AB Fan Would Not Run. WINTER READINESS
11/02/2023
4714679
2SH15AF Fan Would Not Run. WINTER READINESS
11/02/2023
4714683
2SH15AH Fan Would Not Run. WINTER READINESS
11/02/2023
4714684
2SH15AJ Fan Would Not Start. WINTER READINESS
11/02/2023
4714686
2SH15AL Fan Would Not Start. WINTER READINESS
11/02/2023
4714687
2SH15AS Fan Would Not Start. WINTER READINESS
11/02/2023
4714688
2SH15AT Fan Would Not Start. WINTER READINESS
11/02/2023
4716405
Aquaguard Conveyor Belt At River Not Always Working
11/09/2023
21130
2SH15AJ Fan Would Not Start. WINTER READINESS
2/02/2023
21133
2SH15AT Fan Would Not Start. WINTER READINESS
2/02/2023
21135
1SH15AS Fan Would Not Start. WINTER READINESS
2/02/2023
21136
1SH02AG Fan Does Not Run WINTER READINESS
2/02/2023
21143
WINTER READINESS: 0BOSR XFT-A1 Roll Up
2/02/2023
Corrective Action
Documents
21594
PM Hold Codes Applied due to Winter Readiness (RISK)
2/04/2023
BOP HT-T1
Heat Tracing Locations
BOP XFT-1
Cold Weather Operations
OP-AA-108-111-
1001
Severe Weather and Natural Disaster Guidelines
Procedures
Seasonal Readiness
4560616
1B SI Pump Branch Flow Difference
03/09/2023
4562249
1TS-SI059 Needs Setpoint Reset
03/15/2023
21527
RWST Heater (1SI01TA) Not Energized as Expected
2/05/2023
Corrective Action
Documents
4734884
WR Needed for 1B SI Oil Cooler Pipe Replacements in
B1R26
01/23/2024
M-42 Sheet 4
Diagram of Essential Service Water
AQ
Drawings
M-62 Sheet 1A
Diagram of Safety Injection Unit 1
AW
BOP CC-10
Alignment of the U-0 CC Pump and U-0 CC HX to A Unit
BOP CC-E2
Unit 2 Component Cooling System Electrical Lineup
BOP CC-M2
Unit 2 Component Cooling System Valve Lineup
BOP DG-E1
Unit 1 Diesel Generator Electrical Lineup
BOP DG-E2B
Unit 2 Diesel Generator B Train Electrical Lineup
BOP DG-M1A
Unit 1 Diesel Generator A Train Valve Lineup
BOP DG-M1B
Unit 1 Diesel Generator B Train Valve Lineup
BOP DG-M2B
Unit 2 Diesel Generator B Train Valve Lineup
BOP RH-E1A
Residual Heat Removal System Train A Electrical Lineup
BOP RH-M1
Residual Heat Removal System Valve Lineup
BOP RH-M1
Residual Heat Removal System Valve Lineup
BOP SI-E1A
Safety Injection System Train A Electrical Lineup
BOP SI-E1A
Safety Injection System Train A Electrical Lineup
BOP SI-M1A
Safety Injection System Train A Valve Lineup
Procedures
BOP SI-M1C
Safety Injection System Train A Valve Lineup
4930085
Degraded QSS Switch On 1SX007
03/06/2024
284270
Replace Cubicle Fuse Block (1 Pole FU)
03/06/2024
284272
1SX004 Replace Disc Oper Mech LG & SM (131X1-A2)U1
Component Cooling Heat Exchanger
03/06/2024
5369433
PM Inspection, In-Service Diagnostic Test, PIT
03/06/2024
5391301
LR-1SI01SB - Heat Exchanger Inspection Per Generic Letter 89-13
2/07/2024
Work Orders
5417950
(NEIL)-1CS01PB Comprehensive IST Requirements for
2/07/2024
1098450
Four of Eight Studs Are Broken for 1DSH120
08/05/2010
238814
APS As-Found IW Found 3 Broken Studs on Cable Tunnel
Hatch
04/12/2019
Corrective Action
Documents
4518198
Broken Studs on 1DSH120
08/22/2022
4563319
Small Air Leak on 1B Starting Air Compressor
03/19/2023
4670991
Four of Eight Studs Are Broken for 1DSH120
04/18/2023
4690260
1B DG Air Dyer Fan Did Not Start
07/13/2023
4696282
Fuel Handling Building Communication Support
08/14/2023
4702285
1SA142D Extremely Hard to Turn
09/13/2023
4704957
U1 Cable Tunnel Hatch 1DSH120 Broken Studs
09/26/2023
4719720
Submission Requested for Storage Area Approval MA-AA-
716-026
11/27/2023
22396
Unit 1 - Unapproved Modification Requires Removal
2/08/2023
22398
Unit 2 - Unapproved Modification Requires Removal
2/08/2023
22508
Quarterly Review of Fire Brigade Drill Performance
2/09/2023
22845
Staging Wood Pallets near CP Room in light of NFPA 1,
34.10
2/11/2023
22855
0B Fire Pump Right Angle Gear Anti Rotation Device
Damaged
2/11/2023
24102
Unexpected FP Alarm Received in the MCR (1S-23)
2/17/2023
24890
0DSD585 PBI Change
2/21/2023
24992
FP Relay Did Not Actuate as Expected
2/21/2023
25014
UAT 141-1 (1S-15) FP Tamper Switch Not Alarming
2/21/2023
25014
UAT 141-1 (1S-15) FP Tamper Switch Not Alarming
2/21/2023
25659
Spurious Actuation of Fire Suppression Zone 1S-23
2/27/2023
27098
1FP5121 Needs Replaced
01/08/2024
27098
1FP5121 Needs Replaced
01/08/2024
27152
0FP03PB - OB Fire Pump
01/08/2024
27152
0FP03PB - OB Fire Pump
01/04/2024
27203
0FP5351 Handwheel broken
01/08/2024
27455
Fire Barrier Penetrations Found Degraded (Worse Than
Expected)
01/08/2024
4730725
B DG Starting Air Compressor 1DG01SB-B Smoking
01/12/2024
4735591
FP Program Health cornerstone YELLOW for 2P2023
01/24/2024
4736310
Need Removed Valves Inspected
01/25/2024
4749190
Procedure Rev and Replace 0FP578 Vlv
2/10/2024
4759567
Quarterly Review of Fire Brigade Drill Performance
03/20/2024
660861
Broken Stud on Cover of U-1 DG Cable Vault
08/15/2007
Drawings
Auxiliary Building Mezzanine Floor Plan Area 1
AI
PRE-FIRE PLAN
- 176
FZ 12.1-0 Fuel Handling Building 401-0 Elevation Fuel
Handling Building
PRE-FIRE PLAN
- 177
FZ 12.1-0 Fuel Handling Building 426-0 Elevation Fuel
Handling Building
PRE-FIRE PLAN
- 185
FZ 18.1-1 Auxiliary Building 401-0 Elevation 1B DG &
Switchgear Room Air Shaft
Pre-Fire Plan
- 44
Fire Zone 5.2-2, Unit 2, Auxiliary Building 426' Elevation,
Division 21 ESF Switchgear Room
PRE-FIRE PLAN
- 60
FZ 8.3-1 Northwest Turbine Building 401-0 Elevation Unit 1
Turbine Building - NW
PRE-FIRE PLAN
- 61
FZ 8.3-1 Southeast Turbine Building 401-0 Elevation Unit 1
Turbine Building - SE
PRE-FIRE PLAN
- 62
FZ 8.3-1 Southwest Turbine Building 401-0 Elevation Unit 1
Turbine Building - SW
PRE-FIRE PLAN
- 63
FZ 8.3-1 Northeast Turbine Building 401-0 Elevation Unit 1
Turbine Building - NE
Pre-Fire Plan
- 75
FZ 11.6C-0 Auxiliary Building 426'-0" Elevation EMD MOV
Room
Fire Plans
PRE-FIRE PLAN
- 88
FZ 9.1-1, FZ 9.4-1 Auxiliary Building 401-0 Elevation 1B
Diesel Generator & Day Tank Room
0BOL 10.d
LCOAR CO2 Systems
0BOL 10.g
LCOAR Fire Assemblies
BAP 1100-10
Response Procedure for Fire/Fire Alarm
BAP 1100-3
Plant Barrier Impairment Program
BOP DG-21
Diesel Generator Air Receiver Pressure Control
Procedures
Pre-Fire Plan Manual
Work Orders
5356800
FNM Replace Broken Studs On 1DSH120 Hatch
11/29/2023
Corrective Action
Documents
27692
Flooding of WF Pump Room
2/16/2012
Miscellaneous
Report
Individual Plant Examination Submittal Report
04/28/1994
Pre-Fire Plan
- 60
Turbine Building 401' Elevation Unit 1 Turbine Building North-
West
Procedures
Pre-Fire Plan
- 61
Turbine Building 401' Elevation Unit 1 Turbine Building South-
East
Pre-Fire Plan
- 62
Turbine Building 401' Elevation Unit 1 Turbine Building South-
West
Pre-Fire Plan
- 63
Turbine Building 401' Elevation Unit 1 Turbine Building North-
East
Pre-Fire Plan
- 96
Auxiliary Building 330' Elevation Unit 1 Essential Service
Water Pump Room
Procedures
Pre-Fire Plan
- 97
Auxiliary Building 330' Elevation Unit 2 Essential Service
Water Pump Room
Calculations
BYR95-074
SI Pump Oil Cooler Evaluation
10/19/1995
Corrective Action
Documents
4734884
WR Needed for 1B SI Oil Cooler Pipe Replacements in
B1R16
01/23/2024
Miscellaneous
Photographs
36-Photographs of the Heat Exchanger Internal Surfaces and
Pipe Connections
2/08/2024
Work Orders
5391301
LR-1SI01SB - Hx Inspection per Generic Letter 89-13
2/12/2024
Miscellaneous
SEG 24-1-1
LORT Cycle Training
0478846
M&TE Calibration and Control Process
04/14/2006
4348031
N2 Leak on 1B SI Accumulator
06/04/2020
4446314
1SX168 Fail Open Test Failed
09/14/2021
4447840
Sparks Observed after Energizing 133z Transformer
09/22/2021
4449848
Maintenance Rule - 17th (a)(3) Assessment
09/30/2021
4452847
1B VP Chiller Failed to Trip Locally and Remotely
10/14/2023
4453027
NOS ID: Monitor Timeliness of IR Screenings for MRule
10/14/2021
4469617
M&TE OOT Evaluation Tracking - 2022
01/03/2022
4490482
0A SX Makeup Pump Trip
04/05/2022
4492979
04/14/2022
4497537
2CW001C Breaker Needs EMD Troubleshooting
05/04/2022
4498888
U2 Rod Drive Group 1AC Rods Not Moving
05/10/2022
4499432
Received unexpected Unit 2 Rod Control Urgent Failure
Alarm
05/12/2022
4512324
2A SX cooler 2A and 2B Fans Not Running
07/22/2022
4512731
2B DG Trouble Alarm, Inop 2B DG
07/25/2022
29961
2FP010 Failed STT
10/17/2022
4531661
1FP010 Failed Stroke Time Test
10/24/2022
Corrective Action
Documents
4532569
M&TE OOT Evaluation Tracking - 2022
10/27/2022
4538981
1VP01AD 1D RCFC SX Coil Assy Leak-Top Left When
Looking @ Rx
11/25/2022
4540536
MRULE A1 Determinations Performed Incorrectly
2/02/2022
4543255
NRC ID: Maintenance Rule Evaluation Dispositioning
2/16/2022
4543811
M&TE OOT Evaluation Tracking - 2023
2/20/2023
4545582
Gaps Identified During Corp MR Self-Assessment
2/30/2022
4666560
Maintenance Rule - 18th (a)(3) Assessment
03/31/2023
4711156
Intentionally Abbreviated Maintenance on 2FP010
10/20/2023
4713250
Maintenance Rule - Issue Screening Timeliness
10/28/2023
21264
M&TE OOT Evaluation Tracking - 2023
2/03/2023
27420
M&TE OOT Evaluation Tracking - 2024
01/08/2024
Corrective Action
Documents
4751090
MS PORV Controller Major Electronics PM Coming Due
2/18/2024
Miscellaneous
Maintenance Rule (A)(3) Assessment for July 2021 through
December 2022
03/31/2023
Maintenance Rule 18-10 Performance Monitoring and
Dispositioning Between (a)(1) and (a)(2)
Maintenance Rule 18-10 - Periodic (a)(3) Assessment
Procedures
Control of Portable Measurement and Test Equipment
Program
4690260
1B DG Air Dyer Fan Did Not Start
07/13/2023
4698132
Install Thermal Covers on Empty HI Storms
08/23/2023
4700488
ISFSI/DCS Helium Tube Trailer Quantity Needs Verification
09/05/2023
4714534
DCS - Heaters Not Working in Dry Cask Storage Building
11/01/2023
27211
2A DG Failed to Start
01/08/2024
4730048
New DCS/ISFSI Building Heater Transformer Failure
01/11/2024
4730498
Spare RCP Motor Required to Be Rotated to Support
DCS/ISFSI Activities
01/12/2024
4730725
B DG Starting Air Compressor 1DG01SB-B Smoking
01/12/2024
4732126
Framatome Replica Assembly Not Accepted
01/17/2024
4739702
Damaged Grid Strap on Fuel Assembly X27J
01/31/2024
4739765
PMID 00185680-01 ISFSI Installation Inspection Results
01/31/2024
4739796
NRC Identified Discrepancy in Protected Equipment Posting
01/31/2024
4751415
Water in Instrument Lines
2/16/2024
4752030
Change to MPC0951 FSP 2024 DCS
2/20/2024
Corrective Action
Documents
4753384
DCS Trackmobile Parking Break Can Not Be Released
2/26/2024
4753389
DCS - Damaged Cable Port on SLS Jack
2/26/2024
4753579
24 DCS - Weld Vendor Mobilization LL
2/27/2024
4755324
FM in MPC0951
03/04/2024
4755372
DCS - Determination of Supplemental Cooling Required
03/04/2024
4755532
24 DCS - PCI Weld Head Power Supply Error Encountered
03/04/2024
4756524
Alternates Needed for 2024 DCS Assemblies D66H and
D67H
03/07/2023
4757779
NRC-Closure Rings Observation
03/12/2024
4757790
NRC-Cask Spacing on ISFSI Pad Observation
03/13/2024
4757793
Mating Device Air Bags Did Not Hold Pressure
03/13/2024
4757795
NRC-Lift Yoke Paint Observation
03/12/2024
4757824
1B DG Air Compressor Constantly Blowing Down
03/13/2024
4757851
DCS HI-STORM Made Contact With Outer Train Shed Roll
Up Door
03/13/2024
6E-2-4030DG33
Schematic Diagram-Diesel Generator 2A Starting Sequence
Control 2DG01KA Part 3
T
6E-2-4030DG34
Schematic Diagram-Diesel Generator 2A Starting Sequence
Control (Description of Operation) 2DG01KA Part-4
D
Drawings
6E-2-4030DG40
Schematic Diagram-Diesel Generator 2A Shutdown and
Alarm System 2DG01KA
Q
Engineering
Changes
2055
Engineering Review of Rigging Scaffold for 1B DG
Compressor
03/01/2024
Holtec ECO-
5014-312
Engineering Change Order (ECO) for HI-STORM 100 FSAR
NF230405
Cask Loading Requirements Memorandum
Standing Order 2024 Dry Cask Campaign Spent Fuel Pool
Boron Concentration
Plant Barrier
Impairment
Permit 24-014
1B DG roll up door
Miscellaneous
PRA Application
Notebook BY-
MODE-036
TS 3.0.4.b Evaluation - Mode Change with Technical
Specification Equipment out of Service
0BDCSR 3.2.2.1
MPC Surface Contamination Verification
0BDCSR 3.3.1.1
Procedures
2BOSR 8.1.2-1
Unit Two 2A Diesel Generator Operability Surveillance
2BOSR DG-3
Unit Two 2B Diesel Generator Relay Operation Verification
BFP FH-34
Water Transfers of The Spent Fuel Pool, Wet Cask Pit or
Transfer Canal
BFP FH-65
Spent Fuel Cask Site Transportation
BFP FH-73
Unrestrained Stack-Up Support
BFP FH-83
Spent Fuel Cask Contingency Actions
BOP DG-12T1
Inadvertent Diesel Generator Trip Log
Maintenance Specification: Installation of Temporary Rigging
Risk Management
Risk Management Documentation
On-Line Risk Management
Special Nuclear Material and Core Component Move Sheet
Development;
Fuel Selection and Documentation for Dry Cask Loading
Protected Equipment Program
OP-BY-108-117-
1000
1: Protected Equipment Matrix
OP-BY-108-117-
1000
2: Protected Equipment Worksheet
Spent Fuel Loading Campaign Management
Dry Cask Storage / ISFSI Inspection Surveillance Program
Shutdown Safety Management Program Byron/Braidwood
Fuel Movement in the Spent Fuel Pool for Byron and
Braidwood
OU-MW-671-300
MPC Processing Forced Helium Dehydration (FHD) for
PWRS (ISFSI)
OU-MW-679-300
MPC Alternate Cooling for PWRs
Holtec HI-Storm Radiation Survey
On-Line Work Control Process
5332871
Dry Cask Storage Campaign (2024)
03/18/2024
22895
Passport to Asset Suite Contingency (Replace 2PS-DG098A)
01/03/2023
Work Orders
5443933
B DG Starting Air Compressor 1DG01SB-B Smoking
03/12/2024
Calculations
NED-M-MSD-33
Seismic Thrust Limits of the Byron Motor Operated Valves
1(2)SI8812A(B) (Westinghouse, 12, Gate with SB-2-80
Operator)
1617138
0A SX Makeup Pump Jacket Water Failed Coating
2/04/2014
1617139
0A SX Makeup Pump Gear Oil Heat Exchanger Cover Plate
Failed Coating
2/04/2014
4131136
Inactive Boric Acid Leak on Inlet Flange of 1B CS Eductor
04/26/2018
4189826
0A SX Makeup Pump Gear Oil Cooler Heat Exchanger Cover
Plate Coating
10/30/2018
4673210
Intentional abbreviated maintenance
04/25/2023
4680035
Inactive BA Leak - 1B CS Eductor Inlet Flange
05/22/2023
4680371
Unit 1 BACC Focused Walkdown Results
05/22/2023
4682823
NOS ID: LLRT Summary Procedure Not Updated with Current
License Requirements
06/05/2023
4682825
NOS ID: LLRT Summaries Did Not Incorporate New
Administrative Limit, Etc.
06/05/2023
4682827
NOS ID: LLRT Procedure References Not Updated to Current
Regs.
06/05/2023
4689931
1SI8812B Stripped MOV Actuator Motor Mount Bolt
07/11/2023
4690368
1SI8812B Motor Mounting Bolts Not Long Enough
07/12/2023
4702543
Recordable Indications Observed
09/18/2023
4706401
Leakage past 1AF049D
10/01/2023
4710010
2PS9356B Failed As-Found LLRT at 36.6 SCFH
10/16/2023
4717262
P-32 Adverse LLRT Trend (2FC011 & 2FC012)
11/13/2023
4717360
1SX027A EOC Review from IR 4540295
11/13/2023
4717365
1SX027B EOC Review from IR 4540295
11/13/2023
4717379
1SX016A EOC Review from IR 4540295
11/13/2023
4717382
1SX027A EOC Review from IR 4540295
11/13/2023
4717384
1SX027B EOC Review from IR 4540295
11/13/2023
23644
WR/WO for Inspection of SX04AA
2/14/2023
4739551
2A DG Vent Fan Trip on High DP
01/31/2024
4752721
2AF01PA Pump Oil High Viscosity
2/23/2024
4753381
2AF01PA Pump Oil Confirmatory Sample High Viscosity
2/26/2024
4761004
Severe Coating Degradation on 0SX04AA
03/25/2024
Corrective Action
Documents
4761452
WSA/DSA WO# 5429686-02 Support LR Oil Cooler
inspection
03/26/2024
Engineering
Changes
406504
Installation of Vent Valve n Flex Line 1FX001BC-4"
1FX001AD-4" At 401 Elevation In MSIV Rooms
EM-4981
Stress Report for Westinghouse Electro-Mechanical Division
Class I Nuclear Valves
Miscellaneous
F-2891/MRR
7650
Manufacturers' Code Data Report for 0A SX Makeup Pump
10/01/1979
VT-3 Visual Examination for WO 5368348
09/18/2023
1BOSR FX-S1
Unit 1 Auxiliary Feedwater FLEX Connection Low Point Drain
Semiannual Inspection
2BOSR
5.5.8.AF.5-1c
Unit Two Comprehensive Inservice Testing (IST)
Requirements For The Motor Driven Auxiliary Feedwater
Pump 2AF01PA
BMP 3000-16
Application of Metal-Clad Ceramalloy Thin-Film Coating
System
BMP 3222-2
Preventative Maintenance of Essential Service Water
Makeup Pump Drive Unit
BOP AF-300-1
Sampling The Motor Driven Auxiliary Feedwater Pumps
Lubricating Oil Reservoirs
BOP AF-5
Motor Driven Auxiliary Feedwater Pump A Start-up on Recirc
BOP AF-5T1
Motor Driven Auxiliary Feedwater Pump Operating Log
BVP 800-30
Essential Service Water Fouling Monitoring Program
(GL 89-13 Program Basis Document)
Service Water Heat Exchanger Inspection Guide
Boric Acid Corrosion Control (BACC) Program Identification,
Screening, and Evaluation
Evaluation of Leakage From Bolted Connection (Including
ASME Section XI Bolted Connection) for 1B Containment
Spray Pump Eductor Flange
05/31/2023
Quality Material/Components Control and
Identification/Segregation of Non-Conforming Items
Work Execution and Close out
MA-AA-716-230-
1001
Oil Analysis Interpretation Guideline
Operability Determinations (CM-1)
OP-AA-108-115-
1000
Byron Operability Determination Guide
Procedures
OP-AA-108-115-
1002
Supplemental Consideration for On-Shift Immediate
Operability Determinations (CM-1)
1811207
0SX04AA - HX Inspection per Generic Letter 89-13
10/23/2018
4850777
0A SX MU PP Gear Oil Cooler HX Cover Plate Peeled
Coating
04/20/2023
4883641
1RH01PB-M Perform Dynamic Baker Testing
03/01/2020
25070
Replace AF PP/Gearbox Lube Oil System Relief Valve
10/26/2021
4945179
(Change) RHR Pump 1B
2/10/2021
5013683
Perform Inspection of Motor (1RH01PB-M)
01/07/2022
26228
(Change) RHR Pump 1B
10/10/2022
244739
0A SX Makeup Pump Heat Exchanger Coating Inspection
Results
09/30/2023
275473
Essential Service Water Makeup Pump Support 0BVSR
Z.7.A.6-1
03/29/2024
275688
0A SX Diesel Driven Pump Flexible Hoses Replacement
03/29/2024
275688
0A SX Diesel Driven Pump Flexible Hoses Replacement
2/06/2023
279058
PM Inspection, In-Service Diag Test, PIT for 1B RH PP
RWST Suction Isolation Valve (EOP Valve)
07/05/2023
5302761
(Change) RHR Pump 1B
07/10/2023
20059
Perform UT Thickness Exams
03/29/2024
20060
Perform 6Y PM Tasks
01/19/2024
26484
LR-Byron Unit 1 BACC Programmatic Walkdown
09/17/2023
5342199
0019386501, PMSR, 1AF049A-D Seat Leakage Test (Drain
Test), W: 1BOSR FX-S1
10/03/2023
5359325
Intentional Abbreviated Maintenance
04/27/2023
5368348
Inactive BA Leak - 1B CS Eductor Inlet Flange
09/18/2023
5419716
EOC 0A SX Makeup Engine Cylinder Inspection
03/29/2024
29686
WR/WO Needed for Inspection on 0SX02PA-K
03/29/2024
29732
WR/WO for Inspection on 0SX04AA
2/23/2024
5460427
Rebuild/Replace Hydramotor
01/31/2024
5502957
EWP FNM Contingency Change Oil in 2AF01PA Pump
2/27/2024
Work Orders
5510474
LR-0A SX Makeup Pump Operability Surveillance
03/29/2024
4711654
RVLIS Changes Following Disconnect/Reconnect
10/22/2023
4734985
U2 RVLIS Leads Lifting Contrary to Configuration Processes
01/23/2024
Corrective Action
Documents
4758129
NRC Identified - TCC EC 640554 Processing Gaps
03/14/2024
6E-2-4030AP119
Schematic Diagram SAT 242-2 TMS Monitoring, Sheet 8
A
Drawings
Internal Wiring Diagram SAT 242-2 Back Panel #2, Sheet 3
A
633137
Temporary Configuration Change to Remove from Service
Unit 2 RVLIS Train A Sensor #5 and Sensor #8
634666
TCCP - Lift Lead on SAT 242-2 PD-Guard to Eliminate
Nuisance Alarm
Engineering
Changes
640554
TCCP for U2 Train A Sensor #8 RVLIS Leads Lifted
Temporary Configuration Changes
Temporary Configuration Changes
Exelon 50.59 Review Process
Exelon 50.59 Review Process
Procedures
Conduct of Troubleshooting
Work Orders
5414330
RVLIS Changes Following Disconnect/Reconnect
03/14/2024
4518614
OIO BRW/Byron High Head Flex Pump PM Frequency
Difference
08/24/2022
4679767
High Head Flex Pump Design Deficiency
05/22/2023
4690109
FLEX EMNet Satellite Communication Project Timeline >90
Days
07/12/2023
4697929
0FX02PC High Head Flex Pump Has Stuck Open or Bad
Piston
08/22/2023
4702883
2CC9473B - Apparent High Stem to Stem-Nut COF Update
09/14/2023
4715845
NOS ID: FLEX BLDG shelves did not have weight limits
posted
11/02/2023
4717747
0BOL FX1 Comp Actions
11/15/2023
4717962
0A VC Supply Fan Outside Damper (0VC33Y) Dual Indication
11/15/2023
4719261
0A VC Recirculation Charcoal Absorber Inlet Damper
0VC21Y Dual Indication
11/22/2023
4719579
0FX01KD Warning Light Lit
11/25/2023
4719582
0FX01KB Battery Charger Amps and Voltage cycling
11/25/2023
23460
OP-AA-105-102, Att 1 Not Complete for 1st Qtr. 2019
08/20/2019
23737
FLEX Equipment Moving Machines Degraded
2/13/2023
24879
Flex Pump Operating Strategy
2/21/2023
4736374
NRC ID: CETI - 2VA01SA Cooler Outlet Piping
01/25/2024
4736401
NRC CETI - 2A SX Pump Coupling outside of Tolerances
01/24/2024
4748769
Supply Fan 0VV23C Acrid Odor
2/08/2024
4753481
2MS018JDE-BAT Cells 21 and 27 Electrolyte Leaks
2/27/2024
Corrective Action
Documents
4753706
Conditional Release of Switch CID 1718662-1
2/27/2024
4753923
Precharge Pushbutton Not Functional
2/28/2024
4754643
1D PORV Possible Oil Leak
03/01/2024
4755304
0A VC Recirculation Charcoal Absorber Inlet Damper
0VC21Y Dual Indication
03/04/2024
4757447
U2 Pressurizer Backup Group B Htrs 3, 4, & 25 Brkr
03/12/2024
4757527
Pressurizer Heater Breaker Found in the Trip Position
03/12/2024
4757544
Pressurizer Htr Group B & C Lockout Relay Failed to Trip
03/12/2024
4757636
Unit 2 Pressurizer Heater Work Beyond the Scheduled Time
03/13/2024
4757684
Degrading Trip Air Header Pressure on 1B EDG
03/13/2024
4760918
Oil leak on 2RH8716B
03/25/2024
4761540
Active JW Leak on 1A EDG at 9R Inlet Connection
03/27/2024
Drawings
M-42 Sheet 3
Diagram Of Essential Service Water Unit 1 Critical Control
Room Drawing
BG
Engineering
Changes
640749
Modify valve stem of 2CC9473B to Allow Quick Stem Sensor
(QSS) Installation
Plant Barrier
Impairment
Permit 23-089
1DSFSO03 Flood Seal S-672
Miscellaneous
Standing Order
23-027
C High Head Flex Pump Comp Actions
11/10/2023
0BOL FX1
LOCAR Flex Support Equipment
0BOSR FX-14M
Flex Equipment Monthly Surveillance
0BOSR FX-A1
Flex Pump Annual Flow Surveillance
1BOSR 0.5-
2.SX.3-3
Unit One Position Indication Test of 1SX004, 1SX010,
1SX011, 1SX033, 1SX034, and 1SX136
1BOSR 6.3.5-19
Unit One Main Steam System Containment Isolation Valve
Stroke Test
1BOSR 8.1.2-1
Unit One 1A Diesel Generator Operability Surveillance
1BOSR 8.1.2-1
Unit One 1A Diesel Generator Operability Surveillance
1BOSR DG-8A
Unit One 1A DG Turbocharger Spin Down Measurement
1BOSR MS-R1
Unit One Manual Stroke of the S/G PORVS 18 Month
Surveillance
Procedures
2BOSR 0.5-
2.SI.1-1
Unit Two 2SI8821A, 2SI8812A, 2SI8924, 2SI8807B, and
2SI8814 Exercise Test
2BOSR 0.5-
2.SI.2-2.1
Unit Two 2SI8802A, 2SI8806, 2SI8809A, 2SI8835, 2SI8840,
2CV8804A, 2SI8811A, and 2SI8923A Stroke Test and
Position Indication Test
2BOSR 0.5-
2.SI.3-1
Unit Two 2SI8821A, 2SI8812A, 2SI8924, 2SI8807B, and
2SI8814 Position Indication Test
2BOSR 5.2.5-1
ECCS Subsystem Automatic Valve Actuation Test
2BOSR
5.5.8.CC.5-2c
Unit Two Comprehensive Inservice Testing (IST) Surveillance
Requirements for Component Cooling Pump 2CC01PB
Residual Heat Removal Pump 2A Suction Pressure Loop
(RH) Test Package
Calibration of Residual Heat Removal Pump 2A Suction
Pressure Indicator (RH) Test Report Package
BAP 370-1
Station Lubrication Program
BHP 4200-170
4160 to 480 Volt Unit Substation Transformer Inspection and
Testing
BMP 3100-5
Limitorque Operator SMB/SMC Removal and Installation
BMP 3114-1
Charging and Draining Of Main Steam Power Operated Relief
Valve Actuator-Hydraulic and Nitrogen Components
BOP AP-5
Racking out a 4160V or 6900V Air Circuit Breaker to the
Disconnect Position
BOP AP-6
Racking In a 4160V or 6900V Air Circuit Breaker
BOP AP-7
4160V or 6900V Air Circuit Breaker Test Positioning
BOP DG-11T2
Diesel Generator Operating Log
BOP RH-3
Fill and Vent of the Residual Heat Removal System
BOP RH-4
Draining the RH System
BOP SX-1
Essential Service Water Pump Start-Up
BOP VV-23
Operations Of Technical Support Center Hvac System
(VV-TSC)
BOP VV-28
Start-Up And Shutdown Of The Technical Support Center
Hvac Makeup Filter Unit 0VV19S
Motor Operated Valve Maintenance and Testing Guidelines
Conduct of Maintenance Manual
Tool Pouch / Minor Maintenance
Conduct of Troubleshooting
Procedures
MA-AA-716-011-
1003
Maintenance Walk Downs / Feedback
FIN Team Process
Diagnostic Testing of Motor Operated Valves
Periodic Inspection of Limitourque Model SMB/SB/SBD-000
through 5 Motor Operated Valves
Receipt Inspection of New or Refurbished Westinghouse
Type DHP 4kV, 6.9kV, and 13.8kV Circuit Breakers
Preventative Maintenance on Westinghouse Type DHP 4kV,
6.9kV, and 13.8kV Circuit Breakers
Preventative Maintenance on Westinghouse T4kV, 6.9kV, and
13.8kV Switchgear Cubicles
MA-BY-721-001
Three Phase Thermal Overload Relay Testing for Motor
Operated Valves and Various Other Plant Equipment
MA-BY-724-054
Limitorque MOV Motor Removal and Replacement
MA-BY-773-512
Unit 2 - 480V Unit Substation Feed Breaker Relay Routine
OP-BY-FX-1001
Flex Diesel Generator Operation Guideline
Emergent Issue Response
1BHSR PM-2
Calibration of Time Delay Relays
26549
MOV PM, Actuator Inspection, Diagnostic Testing
03/20/2024
4945433
LR-2VA01SA - HX Inspection Per Generic Letter 89-13
01/25/2024
4947965
Bus 241 Outage MCC 231X1-H4 Breaker Tripped out of
Tolerance
2/27/2024
5002175
Ops - 3 Year Performance Full Flow Test of Flex Pump
11/29/2023
217787
4KV Switchgear Cubicle Inspection (Bus 244 CUB 10) -
03/13/2024
217788
4KV Breaker Swap (Bus 244 CUB 10) - 2AP08E-K
03/13/2024
25499
Clean, Inspect, and Tighten All Connections on Transformer
2RY01EB
03/13/2024
25864
Clean, Inspect, and Tighten All Connections on Transformer
2RY01EC
03/13/2024
252454
4KV Relay Routine Calibration (244 FD to PZR Heater B & C)
03/13/2024
271130
PM Inspection, In-Service Diag Test, PIT
03/26/2024
281470
Replace Motor on 0VV23C
2/09/2024
283878
U1 (SX-3-2) VT XI (1B Pump Train Work)
03/20/2024
Work Orders
284271
1SX033 Replace Cub Fu Blk(1)(131X1-A4) U1 Pump
Discharge Crosstie
03/20/2024
290075
(Change/Sample) [Oil] Safety Injection Pump 2A
2/28/2024
290745
Retorque 2SI8814 in 1 Year
2/27/2024
296469
EXTST for
2SI8802A,8806,8809A,8835,8840,8804A,8811A,8923A
03/26/2024
299138
4kV Switchgear Cubicle Inspection (But 242 Cub 13) -
03/22/2024
299424
2CC9473 Discharge Crosstie Thermal Overload Surveillance
03/21/2024
5302762
EXTST for 2SI8811A
03/26/2024
5303074
ECCS Sub System Automatic Valve Actuation Test
03/26/2024
5304096
4kV Breaker Swap (But 242 Cub 13) - 2AP06E-N
03/22/2024
5304097
CC Surge Tank Low Level Switch;
03/22/2024
5311498
2B CC Pump Motor, Outboard Bearing Oil Drain Plug
Rounded Off
03/22/2024
5312094
1AP06EB Relay #SX1BX for 1SX01PB
03/20/2024
5312096
Perform Static Baker Test MA-AA-723-330
03/20/2024
21154
U-1 Manual Stroke of the S/G PORVS-1D
2/29/2024
5330915
(Sample/Change) Component Cooling Pump 2B
03/22/2024
5351732
1SX01PB-M Perform Dynamic Baker Testing
03/20/2024
5359119
Position Indication Test of 1SX033
03/20/2024
5364407
(Check) Essential Service Water Strainer 1B
03/20/2024
5364412
(Sample) Essential Service Water Pump 1B
03/20/2024
5379461
Need WR/WO to Clean 2A RH Pump Bowl during Next Work
Window
03/26/2024
5380211
Measure Turbocharger Spin Down Time 1BOSR DG-8A
03/28/2024
5384649
2SI8807B Thermal OL Surveillance (MCC 232X1-G3)
2/27/2024
5394121
0FX02PC High Head Flex Pump Has Stuck Open or Bad
Piston
2/28/2023
5401563
2CC9473B - Apparent High Stem to Stem-Nut COF Update
03/22/2024
5401563-02
Machine Threads off Valve Stem per EC 640749 to Allow
Sensor Installation
5401563-16
Cut Stem in Field to Munt QSS Sensor
5402721
LR-(Sample) Essential Service Water Pump 1B
03/20/2024
5416167
EOC Work Required for DG Vent Fan failure
03/28/2024
25042
LR-Control Room Ventilation Train 0A Surveillance
03/04/2024
26049
Stroke Time Test 1AF005A-D
03/04/2024
26050
Stroke Time Test 2AF005A-D
03/04/2024
5443249
Samp/Repl/Flush Hyd Fluid In Actuator & Hand Pump
2/29/2024
5456687
2SI01PA Group A IST Requirements for Safety Injection
Pump
2/28/2024
5475997
(NEIL)-LR-1A Diesel Generator Operability Surveillance
2/28/2024
5476077
(NEIL)- 2CC01PB Comp IST RQMTS for Residual CC Pump
03/22/2024
5512994
LR-(Sample) 1A Diesel Generator
03/28/2024
BHP 4200-52
Polarization Index and Delta Resistance Tests
BHP-EQ-93B
Replacement of Single and Double Pole Fuse Block
Assemblies
BOP SX-300-1
Sampling the Essential Service Water Pumps Lubricating Oil
Reservoirs (1SX01PB)
Periodic Inspection of Limitorque Model SMB/SB/SBD-000
Through 5 Motor Operated Valves
Electrical Testing of AC Motors Using Baker Instrument
Advanced Winding Analyzer
MA-BY-722-003
Annual Inspection and Testing of 4kV and 6.9kV Motors
200578
2PM10J SEVERAL LED BUTTONS ON 2RM23 PANEL
FAILING
2/05/18
242491
2ES013C NOT INDICATING FULL CLOSED ON 2PM03J
04/22/2019
245106
2MS031D Low Point Drain Valve Not Cycling Correctly
05/01/2019
4357146
Containment Pressure Channel Deviation
07/16/2020
4374425
2CB118A Failed to Auto Open
10/05/2020
4386121
Electrically Determine Why 2CB118A Fails to Stroke Open
11/23/2020
4386606
PMT Failed WO 4946434 2HD059A indicates Dual When
Open
11/26/2020
4396737
2A FW Pump Flow Is Showing 0.5 MBH When There Is no
Flow
01/19/2021
20709
Unexpected Alarm Bus 214 Inverter Trouble
05/01/2021
4431096
SAT 242-2 Trouble Alarm in MCR
06/23/2021
4446965
LPMS TROUBLE
09/16/2021
4454399
2PS230A Position Indication Not Working
10/20/2021
4456900
Button and Backlamp Bulb on 2RIU-PR030
10/28/2021
Corrective Action
Documents
4461721
Unit-2 FSIC Trouble
11/18/2021
4470046
2S-34 Trouble Light Not Lit
01/05/2022
4482056
2C RCP Stator Winding Temp Failed
03/02/2022
4491651
MS Line Low Pt. Drain, 2MS031D, Not Cycling Properly
04/08/2022
4493780
2CB118A Failed to Open
04/18/2022
4497311
Sat 242-2 Unexpected Alarms
05/03/2022
4498553
2ES013C Not Indicating Closed
05/09/2022
4498812
2FW034C Not Showing Closed on FWI Monitor Lights
05/10/2022
4498972
U-2 LPMS Channel 11 Dead
05/11/2022
4499303
2FW046A Won't Swap Back to Manual on 2PM04J
05/12/2022
4499388
2BOSR FW-Q1 Failed Acceptance Criteria
05/12/2022
4499469
2ES017B Open Light Not Working
05/12/2022
4500072
2ES017C Shows Dual on MCB
05/16/2022
4500221
2D RCP #1 Seal Inj Line LPMS Alarm
05/17/2022
4503765
2ES079 Open Light Did Not Light
06/04/2022
4506033
Zone 2D-75 Spurious Fire Alarm
06/17/2022
4509598
Low HP GS Pressure
07/06/2022
4510089
Pressurizer Liquid Temp Indicating Lower Than Expected
07/09/2022
4511307
Unit 2 RVLIS Train B, Sensor #3 Error Codes
07/06/2022
4514245
Unit 2: B Train RVLIS Sensor #3 Alarm
08/01/2022
4515989
U-2 Loose Parts Monitoring System Alarm, 2-13-E9
08/09/2022
4516609
Unexpected Annun. 2-18-D13, H2 Stator Clg Panel Trouble
08/12/2022
4517694
2HD059A Indicates Dual When Open
08/19/2022
4519559
2C Feedwater Pump Low Oil Alarm
08/30/2022
20244
ES Level Controller output Is Suspect
09/01/2022
22678
2FW046A Controller (2FK-FW245) Degraded and Needs
Replaced
09/15/2022
26264
Unexpected H2/Stator Cooling Panel Trouble Alarm
(2-18-D13)
10/02/2022
27378
2D MSR First Stage Drain Tank Level Oscillation
10/06/2022
4535311
LPMS TRM Elimination Project
11/07/2022
4538144
2D 1st Stage RDT Level High/Low Alarm (2-18-B5)
11/19/2022
4543602
2D First Stage Reheat Drain Tank High/Low
2/19/2022
4551270
2A MSIV Accumulator Pressure Low
01/30/2023
4561565
Unexpected 'MAIN XFMR 2E TROUBLE' Alarm in the MCR
03/13/2023
4699955
Procedure Enhancements for Causal Evaluation
09/01/2023
4700973
NRC ID: Procedure Enhancement for BMP 3100-23
09/06/2023
4713783
2ES008 Limit Switch
10/30/2023
4713788
2ES015B Showing Dual in MCR
10/30/2023
4713789
2ES032B open
10/30/2023
20070
Containment Sum Isolation Relief Valves Trend IR
11/28/2023
4731466
Misc. Byron IST and App J Actions
01/16/2024
4754631
Rejection of CA 4712019-11
03/01/2024
4754631
Rejection of CA 4712019-11
03/01/2024
Miscellaneous
None
Control Room Deficiencies Report
01/29/2024
BMP 3100-23
IST Crosby Safety/Relief Valve Bench Testing
Procedure Use and Adherence
Equipment Deficiency Identification and Documentation
OP-AA-108-105-
1001
MCR and RWCR Equipment Deficiency Management and
Performance Indicator Screening
Corrective Action Program (CAP) Procedure
Procedures
Investigation Techniques Manual
7