DEC-1 9 1986
,
.
I m.
.
Docket No. 50-454
~ Docket No. 50-455
,
Commonwealth Edison Company
,
ATTN: Mr..Cordell Reed
,Vice President i-Post Office Box 767.
]-
-Chicago, IL-60690
'
- Gentlemen:
This refers to the special safety inspection conducted by Messrs. J. A. Gavula and I. -T. Yin of this office and Mr. J. R. Fair of Headquarters from September 15 i
through November 13, 1986, of activities at the Byron Station, Units 1 a'nd 2, authorized by NRC Operating Licenses No. NPF-37 and No. NPF-60 and to the
discussion of our findings with Mr. P. Donavin at the conclusion of the t
inspect *on.
Personnel from the Illinois-Department of Nuclear Safety participted in this inspection.
!
-On December 17, 1986, the NRC met with members of the State of Illinois'
~
Governor's staff, Commerce Commission, and Department of Nuclear Safety.
The
< purpose of this meeting was to discuss CIE's concerns and the results of this inspection.
!
i-The enclosed copy of our inspection report identifics areas examined during the inspection.
Within these areas, the inspection consisted of a selective
examination of procedures and representative records, observations, and interviews with-personnel.
J During this inspection, certain of your activities appeared to be in violation of NRC requirements, as specified in the enclosed Notice.
The inspection showed that action had been taken to correct the identified violation and to prevent-
,
!
recurrence.
Our understanding of your corrective actions are described in
,
your letter to us dated December 1, 1986.
Consequently, no reply to the L
violation is required and we have no further questions regarding this matter at j
this time.
,
i In accordance with 10 CFR 2.790 of the Cortnission's regulations, a copy of
'
this letter the enclosures and your response to this. letter will be placed in the NRC Public Document Room.
f i
The responses directed by this letter and the accompanying Notice (Order)
are not subject to the clearance procedures of the Office of Management
,
l and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.
h2 h
[
,
O i
\\&
{
-
.
Commonwealth Edison Company
DEC 191986 We will gladly discuss any questions you have concerning this inspection.
Sincerely,
.
I Carl ap iello, Director
.
Division of Reactor Safety Enclosures:
1.
Inspection Reports No. 50-454/86027(DRS);
No. 50-455/86044(DRS)
3.
December 17, 1986, Meeting Viewgraphs cc w/ enclosures:
D. L. Farrar, Director of Nuclear Licensing V. I. Schlosser, Project Manager Gunner Sorensen, Site Project Superintendent R. E. Querio, Plant Manager DCS/RSB (RIDS)
Licensing Fee Management Branch Resident Inspector, RIII Byron Resident Inspector, RIII Braidwood Phyllis Dunton, Attorney General's Office, Environmental Control Division D. W. Cassel, Jr., Esq.
Diane Chavez, DAARE/ SAFE L. 01shan, LPM, NRR H. S. Taylor, Quality Assurance Division qe 4eS h
RIII RIII RIII R
RI
drgrl/
4MV/
dh
%
GA v a/jk fYin MFair F(orney Weil 11/18/86 0 12//('/86
/ 12////86 12h$/86 12/[s/86 y
@
(f i
Da on Harrison PapePiello 12////86 12/16/86 12/jf/86
.
-
.
-.
..
__ ____
_
..
.
.
-