July 25, 2008
SUBJECT:
NINE MILE POINT NUCLEAR STATION - NRC INTEGRATED INSPECTION REPORT 05000220/2008003 and 05000410/2008003
Dear Mr. Polson:
On June 30, 2008, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Nine Mile Point Nuclear Station, Units 1 and 2. The enclosed integrated inspection report documents the inspection results discussed on July 16, 2008, with you and members of your staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.
This report documents three self-revealing findings and two NRC-identified findings of very low safety significance (Green). Four of the findings were determined to involve violations of NRC requirements.
However, because of their very low safety significance and because they were entered into your corrective action program (CAP), the NRC is treating these findings as non-cited violations in accordance with Section VI.A.1 of the NRCs Enforcement Policy. If you contest the non-cited violations noted in this report, you should provide a response with the basis for your denial, within 30 days of the date of this inspection report, to the Nuclear Regulatory Commission, ATTN.: Document Control Desk, Washington, D.C. 20555-0001; with copies to the Regional Administrator, Region I; the Director, Office of Enforcement; U.S. Nuclear Regulatory Commission, Washington, D.C. 20555-001; and the NRC Senior Resident Inspector at Nine Mile Point Nuclear Station.
In accordance with 10 CFR Part 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRCs document system (ADAMS). ADAMS is accessible from the NRC Web Site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Glenn T. Dentel, Chief Projects Branch 1 Division of Reactor Projects
Docket No.:
50-220, 50-410 License No.: DPR-63, NPF-69
Enclosure:
Inspection Report 05000220/2008003 and 05000410/2008003 w/Attachment: Supplemental Information
cc w/encl:
M. Wallace, Vice - Chairman, Constellation Energy H. Barron, President, CEO & Chief Nuclear Officer, Constellation Energy Nuclear Group C. Fleming, Esquire, Senior Counsel, Nuclear Generation, Constellation Energy Group, LLC M. Wetterhahn, Esquire, Winston & Strawn T. Syrell, Director, Licensing, Nine Mile Point Nuclear Station P. Tonko, President and CEO, New York State Energy Research and Development Authority J. Spath, Program Director, New York State Energy Research and Development Authority P. Eddy, New York State Department of Public Service C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law Supervisor, Town of Scriba P. Church, Oswego County Administator T. Judson, Central NY Citizens Awareness Network D. Katz, Citizens Awareness Network G. Detter, Manager, Nuclear Safety and Security, Constellation Energy NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRCs document system (ADAMS). ADAMS is accessible from the NRC Web Site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Glenn T. Dentel, Chief Projects Branch 1 Division of Reactor Projects
SUMMARY OF FINDINGS
IR 05000220/2008003, 05000410/2008003; 04/01/08 - 06/30/08; Nine Mile Point Nuclear Station,
Units 1 and 2; Maintenance Risk Assessment, Outage Activities, Surveillance Testing, and Other Activities.
The report covered a three-month period of inspection by resident inspectors and regional specialist inspectors. Four Green non-cited violations (NCVs), and one Green finding, were identified. The significance of most findings is indicated by their color (Green, White, Yellow,
Red) using Inspection Manual Chapter (IMC) 0609, Significance Determination Process (SDP).
Findings for which the SDP does not apply may be Green or be assigned a severity level after NRC management review. The NRC's program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process, Revision 4, dated December 2006.
NRC-Identified and Self-Revealing Findings
Cornerstone: Initiating Events
- Green.
A self-revealing finding was identified on April 18, 2008, when NMPNS failed to take appropriate corrective actions to address corrosion products in the instrument air (IA) system in a timely manner, which led to an accumulation of water in the Unit 2 IA system. As a result, water intrusion into the air operator for the 'B' reactor feedwater pump recirculation valve caused the valve to open during plant power ascension, causing a reduction in feedwater flow to the reactor and thereby challenging plant stability. As immediate corrective action, operators secured power ascension and isolated the recirculation valve.
The finding was greater than minor because it was associated with the equipment performance attribute of the Initiating Events cornerstone and adversely affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations.
The finding was evaluated in accordance with IMC 0609, Attachment 4, and determined to be of very low safety significance per the SDP Phase one determination because the finding did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions would not be available, and it did not screen as potentially risk significant due to external events. The finding had a cross-cutting aspect in the area of problem identification and resolution because NMPNS did not take appropriate corrective actions to address corrosion products in the IA system in a timely manner (P.1.d per IMC 0305). (Section 1R20)
Cornerstone: Mitigating Systems
- Green.
A self-revealing non-cited violation (NCV) of Technical Specification (TS) 6.1,
"Responsibility," was identified on April 26, 2008, when the Unit 1 shift manager (SM)
left the control room without designating another senior reactor operator (SRO)qualified individual to assume the control room command function. When the condition was identified, the SM promptly returned to the control room.
The finding was greater than minor because it could reasonably be viewed as a precursor to a significant event. Specifically, the absence of SRO oversight during licensed control room activities increases the likelihood of human performance errors, which in turn, increases the likelihood of an initiating event and reduces the effectiveness of event mitigation. The finding has been reviewed by NRC management in accordance with IMC 0609, Appendix M, "Significance Determination Process Using Qualitative Criteria," and was determined to be of very low safety significance because of the short period that the SM was not present in the control room, and because no initiating events occurred during that time. The finding had a cross-cutting aspect in the area of human performance because of the ineffective use of human error prevention techniques (H.4.a per IMC 0305). (Section 1R13)
- Green.
A self-revealing non-cited violation (NCV) of 10 CRF 50, Appendix B, Criterion XVI, "Corrective Action," was identified on March 22, 2008, when the Unit 2 Division I emergency diesel generator (EDG) service water (SW) return isolation valve failed to fully open following a start of the Division I EDG, thus challenging the EDG's ability to perform its safety function. The motor operated valve (MOV) malfunction was due to age-related failure of the J-10 relay in the MOV control circuit. The susceptibility of J-10 relays to age-related failure had been previously identified; however, NMPNS did not take action to establish a maintenance strategy to replace these relays prior to failure. As corrective action, the EDG was declared inoperable, the J-10 relay was replaced, and an extent of condition review was initiated.
The finding was greater than minor because it was associated with the equipment performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding was evaluated in accordance with IMC 0609, Attachment 4, and determined to be of very low safety significance per the SDP Phase one determination because the finding was not a design or qualification deficiency, did not represent a loss of a system/train safety function, and did not screen as potentially risk significant due to external events. (Section 1R22)
- Green.
An NRC-identified non-cited violation (NCV) of Unit 1 Technical Specification (TS) 6.2.2 and Unit 2 TS 5.2.2, "Unit Staff," was identified for not properly implementing and maintaining procedures for controlling plant staff work hours of personnel performing safety-related activities. Specifically, over 400 overtime deviations were approved between July 2007 and April 2008 for Operations personnel to work greater than procedurally established work hour limits for routine outage support activities during outages and other reasons not permitted by TS. Corrective actions were being developed to increase qualified operator levels.
The finding was greater than minor because, if left uncorrected, it would become a more significant safety concern. Specifically, the excessive work hours would increase the likelihood of human errors during plant activities and response to plant events. The finding has been reviewed by NRC management in accordance with IMC 0609, Appendix M, "Significance Determination Process Using Qualitative Criteria."
Although the increased likelihood of human error would adversely affect the stations defense-in-depth, the violation was determined to be of very low significance because no significant events or human performance issues were directly linked to personnel fatigue as a result of the hours worked. The issue had a cross-cutting aspect in the area of human performance because the licensee did not use conservative assumptions in decision making, in that, the consequences of the high number of overtime deviations were not fully considered and the possible unintended consequences evaluated. (H.1.b per IMC 0305). (Section 4OA5)
- Green.
A non-cited violation (NCV) of Unit 1 Technical Specification (TS) 6.2.2 and Unit 2 TS 5.2.2, "Unit Staff," was identified by the inspectors for a recurring trend of operations personnel being required to stand 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> shifts in order to ensure adequate shift coverage. There were eight occurrences between May 2007 and May 2008. Several of these overtime deviations were not properly authorized or documented in accordance with station procedures as required by TS. Corrective actions were being developed to increase qualified operator levels.
The finding was greater than minor because, if left uncorrected, it would become a more significant safety concern. Specifically, the excessive work hours would increase the likelihood of human errors during plant activities and response to plant events. The finding has been reviewed by NRC management in accordance with IMC 0609, Appendix M, "Significance Determination Process Using Qualitative Criteria."
Although the increased likelihood of human error would adversely affect the stations defense-in-depth, the violation was determined to be of very low significance because no significant events or human performance issues were directly linked to personnel fatigue as a result of the hours worked. The issue has a cross-cutting aspect in the area of problem identification and resolution because NMPNS failed to periodically trend and assess information from the corrective action program and other assessments in the aggregate to identify programmatic and common cause problems (P.1.b per IMC 0305). (Section 4OA5)
Licensee-Identified Violations
A violation of very low safety significance, which was identified by NMPNS, has been reviewed by the inspectors. Corrective actions taken by NMPNS have been entered into NMPNS corrective action program (CAP). The violation and corrective action tracking number are listed in Section 4OA7 of this report.
REPORT DETAILS
Summary of Plant Status
Nine Mile Point Unit 1 began the inspection period at full rated thermal power (RTP). On May 3, power was reduced to 70 percent for a control rod sequence exchange, single rod scram time testing, repair of a shell side leak from the 132 feedwater heater, and to restore 15 reactor recirculation pump (RRP) to service. Power was restored to full RTP later that day. On May 13, a loss of offsite power line 4 while offsite power line 1 was out of service for maintenance resulted in a power reduction to 92 percent due to loss of power to 13 RRP. Later that day, offsite power was restored through line 1, 13 RRP was returned to service, and power was restored to full RTP. With the exception of short duration power reductions and recoveries for planned maintenance and testing, Unit 1 operated for the remainder of the inspection period at full RTP.
Nine Mile Point Unit 2 began the inspection period in refueling outage (RFO) 11, which had commenced on March 22. On April 16, operators commenced plant startup and reached full RTP on April 20. On May 31, power was reduced to 70 percent for a control rod sequence exchange, single rod scram time testing, turbine valve testing, and maintenance on the 'B' heater drain pump. Power was restored to full RTP the following day. Except for two occasions when 6B feedwater heater equipment malfunctions required short duration power reductions, Unit 2 operated for the remainder of the inspection period at full RTP.
REACTOR SAFETY
Cornerstones: Initiating Events, Mitigating Systems, and Barrier Integrity
==1R01 Adverse Weather Protection (71111.01 - Five samples)
==
.1 Readiness of Offsite and Alternate AC Power Systems (Two samples)
a. Inspection Scope
The inspectors verified that plant features and procedures for operation and continued availability of offsite and alternate alternating current (AC) power systems for Unit 1 and Unit 2 during adverse weather are appropriate. The inspectors reviewed Operations Administrative Procedure S-ODP-OPS-0112, "Off-Site Power Operations and Interface,"
to ensure that appropriate information is exchanged between NMPNS and the transmission system operator (TSO) when issues arise that could impact the offsite power system. The inspectors also verified that NMPNS procedures address measures to monitor and maintain availability and reliability of both the offsite AC power system and the onsite alternate AC power system prior to, and during, adverse weather conditions.
b. Findings
No findings of significance were identified.
.2 Readiness for Seasonal Extreme Weather Conditions (Two samples)
a. Inspection Scope
The inspectors verified the seasonal readiness for Unit 1 and Unit 2 in accordance with NMPNS procedure NAI-PSH-11, Seasonal Readiness Program. The inspectors reviewed and verified completion of the operations department hot weather preparation checklists contained in procedures N1-OP-64 and N2-OP-102, Meteorological Monitoring, for Units 1 and 2, respectively. The inspectors reviewed the procedural limits and actions associated with elevated lake temperature and walked down selected areas of the plants to assess the effectiveness of the ventilation systems. In addition, the inspectors performed partial system walkdowns of the following risk significant systems that could be susceptible to the effects of hot weather:
- Unit 1 service water system;
- Unit 1 reactor building emergency ventilation system;
- Unit 2 service water system; and
- Unit 2 control building air conditioning system.
b. Findings
No findings of significance were identified.
.3 Readiness to Cope with External Flooding (One sample)
a. Inspection Scope
The inspectors reviewed the individual plant examinations (IPEs) and updated final safety analysis reports (UFSARs) for Units 1 and 2 concerning external flooding events at the site. The inspection included a walkdown of accessible areas of each units perimeter to look for potential susceptibilities to external flooding and to verify the assumptions included in each units external flooding analysis. The inspectors also reviewed relevant abnormal and emergency plan procedures.
b. Findings
No findings of significance were identified.
==1R04 Equipment Alignment
==
.1 Partial System Walkdown (71111.04 - Four samples)
a. Inspection Scope
The inspectors performed four partial system walkdowns to verify risk-significant systems were properly aligned for operation. The inspectors verified the operability and alignment of these risk-significant systems while their redundant trains or systems were inoperable or out of service for maintenance. The inspectors compared system lineups to system operating procedures, system drawings, and the applicable chapters in the UFSAR. The inspectors verified the operability of critical system components by observing component material condition during the system walkdown. The inspectors performed partial walkdowns of the following systems:
- Unit 1 core spray system 112 while the core spray system 111 was inoperable for valve inspections;
- Unit 1 EDG 102 and power board while EDG 103 was inoperable for emergent maintenance;
- Unit 2 'A' residual heat removal (RHR) system while the 'C' RHR system was inoperable for planned maintenance; and
- Unit 2 high pressure core spray (HPCS) system while the low pressure core spray (LPCS) system was inoperable for planned maintenance.
b. Findings
No findings of significance were identified.
.2 Complete System Walkdown (71111.04S - One sample)
a. Inspection Scope
The inspectors performed a complete walkdown of the Unit 2 C RHR system to identify discrepancies between the existing equipment configuration and that specified in the design documents. During the walkdown, system drawings and operating procedures were used to determine the proper equipment alignment and operational status. The inspectors reviewed the open maintenance work orders (WOs) that could affect the ability of the system to perform its functions. Documentation associated with temporary modifications, operator workarounds, and items tracked by plant engineering were also reviewed to assess their collective impact on system operation. In addition, the inspectors reviewed the condition report (CR) database to verify that equipment alignment problems were being identified and appropriately resolved.
b. Findings
No findings of significance were identified.
==1R05 Fire Protection
==
.1 Quarterly Inspection (71111.05Q - Seven samples)
a. Inspection Scope
The inspectors toured seven areas important to reactor safety at NMPNS to evaluate the stations control of transient combustibles and ignition sources, and to examine the material condition, operational status, and operational lineup of fire protection systems including detection, suppression, and fire barriers. The areas inspected included:
- Unit 1 111/121 containment spray pump room, reactor building 198 foot elevation;
- Unit 1 cable spreading room, control complex 250 foot elevation;
- Unit 1 auxiliary control room, control complex 261 foot elevation;
- Unit 1 diesel fire pump room, screen house 256 foot elevation;
- Unit 1 turbine building east, 277 foot elevation;
- Unit 2 west electrical tunnel, control building 220 foot elevation; and
- Unit 2 turbine building 250 foot elevation.
b. Findings
No findings of significance were identified.
==1R06 Flood Protection Measures (71111.06 - One sample)
a. Inspection Scope
==
The inspectors completed one internal flooding sample. The inspectors reviewed the individual plant examination (IPE) and UFSAR for Unit 2 concerning internal flooding events and completed walkdowns of two areas in which flooding could have a significant impact on risk. The EDG and emergency standby switchgear rooms, and the turbine building/reactor building elevation 250 foot interfacing areas were reviewed.
b. Findings
No findings of significance were identified.
==1R07 Heat Sink Performance (71111.07A - One sample)
a. Inspection Scope
==
The inspectors reviewed the testing and results for the Unit 1 reactor building closed loop cooling system heat exchanger 13, performed in accordance with procedure N1-TTP-033, Reactor Building Closed Loop Cooling Heat Exchanger Performance Test. The inspectors reviewed performance data to verify that heat exchanger operation was consistent with its design basis. The inspectors conducted interviews with design and system engineers to ensure the test was controlled properly and to verify the overall condition of the heat exchanger.
b. Findings
No findings of significance were identified.
==1R11 Licensed Operator Requalification Program (71111.11Q - Two samples)
a. Inspection Scope
==
The inspectors evaluated two simulator scenarios in the licensed operator requalification training (LORT) program. The inspectors assessed the clarity and effectiveness of communications, the implementation of appropriate actions in response to alarms, the performance of timely control board operation, and the oversight and direction provided by the shift manager. During the scenario, the inspectors also compared simulator performance with actual plant performance in the control room. The following scenarios were observed:
- On May 21, 2008, the inspectors observed Unit 1 LORT to assess operator and instructor performance during a scenario involving electronic pressure regulator oscillations, a ground on battery board 11, initiation of emergency cooling loop 11, and an unisolable steam leak in the reactor building. The inspectors evaluated the performance of risk significant operator actions including the use of special operating procedures (SOPs) and emergency operating procedures (EOPs).
- On May 21, 2008, the inspectors observed Unit 2 LORT to assess operator and instructor performance during a scenario involving an inadvertent isolation of reactor core isolation cooling (RCIC), loss of the running instrument air compressor while another compressor was unavailable for maintenance, an unplanned reactor power increase due to a recirculation flow control valve drifting open, and an unisolable steam leak outside of the primary containment that led operators to perform a reactor blowdown. The inspectors evaluated the performance of risk significant operator actions including the use of SOPs and EOPs.
b. Findings
No findings of significance were identified.
==1R12 Maintenance Effectiveness (71111.12Q - Three samples)
a. Inspection Scope
==
The inspectors reviewed performance-based problems and the performance and condition history of selected systems to assess the effectiveness of the maintenance program. The inspectors reviewed the systems to ensure that the stations review focused on proper maintenance rule scoping in accordance with 10 CFR Part 50.65, characterization of reliability issues, tracking system and component unavailability, and 10 CFR Part 50.65 (a)(1) and (a)(2) classification. In addition, the inspectors reviewed the sites ability to identify and address common cause failures and to trend key parameters.
The following three maintenance rule inspection samples were reviewed:
- Unit 1 instrument air system for possible common failure modes with Unit 2;
- Unit 1 service water seal water system based on system degradation due to fouling; and
- Unit 2 turbine building closed loop cooling system based on degraded pump expansion joints and a heater drain pump seal cooler leak that resulted in condensate leakage into the system.
b. Findings
No findings of significance were identified.
==1R13 Maintenance Risk Assessments and Emergent Work Control (71111.13 - Six samples)
a.
==
Inspection Scope
The inspectors evaluated the effectiveness of the maintenance risk assessments required by 10 CFR Part 50.65 (a)(4). The inspectors reviewed equipment logs, work schedules, and performed plant tours to verify that actual plant configuration matched the assessed configuration. Additionally, the inspectors verified that risk management actions for both planned and emergent work were consistent with those described in station procedures.
The inspectors reviewed risk assessments for the activities listed below.
Unit 1
- Week of April 28, 2008, that included main steam isolation valve (MSIV) partial stroke testing, control rod drive pump quarterly surveillance, liquid poison pump monthly surveillance, the start of a planned two week outage of one of the two outgoing 345 kilovolt (kV) transmission lines, emergency service water quarterly surveillance, and a planned power reduction to 70 percent for a control rod sequence exchange, single rod scram time testing, repair of a shell side leak on the 132 feedwater heater, and recovery of 15 reactor recirculation pump.
- Week of May 19, 2008, that included core spray 111 and 121 quarterly surveillances, EDG 102 monthly surveillance, power reductions to secure 15 reactor recirculation motor-generator for maintenance and then return it to service, calibration of the power range neutron monitoring system using the transverse in-core probe system, reactor vessel low level instrument calibrations, and emergent maintenance to provide a temporary water supply to the service water seal water system, correct a service water strainer malfunction, and repair the EDG 103 turbocharger lubricating oil pump.
Unit 2
- Week of April 21, 2008, that included HPCS instrument surveillances, valve testing and system quarterly surveillance, Division 3 EDG monthly surveillance, main steam line flow instrument calibration, an emergent issue with an instrument air dryer that resulted in water intrusion into the instrument air system, and an emergent failure of the 'A' reactor protection system motor-generator.
- Week of May 5, 2008, that included 1B battery charger maintenance, Division 1 EDG monthly surveillance, RCIC quarterly surveillance, 'A' RHR quarterly surveillance, test discharge of the 1B station battery, and an emergent issue to address voiding in the low pressure core spray pump suction line.
- Week of May 26, 2008, that included a power reduction for control rod sequence exchange, single rod scram time testing, MSIV and turbine valve partial exercise testing, maintenance on a stator water cooling system pump, maintenance on the 345 kV outgoing transmission lines, and a reactor water cleanup system outage.
- Week of June 16, 2008, that included low pressure core spray quarterly surveillance, Division 1 EDG monthly surveillance, Division 1 standby gas treatment system 24-month functional test, Division 1 standby liquid control system quarterly surveillance, an emergent failure of the normal level control valve for the 6B feedwater heater that resulted in a power reduction to 91 percent, and an emergent problem with uninterruptable power supply (UPS) 3B that produced a half scram.
b. Findings
Introduction.
A self-revealing Green NCV of TS 6.1, "Responsibility," was identified on April 26, 2008, when the Unit 1 shift manager left the control room without designating another SRO-qualified individual to assume the control room command function.
Description.
On April 26, 2008, an equipment problem developed with the Unit 1 plant communication system. The Control Room Supervisor (CRS), one of two SRO-qualified individuals in the watch section, left the control room to investigate the problem. While the CRS was gone, the SM wanted to show another individual the location of components in the auxiliary control room that could be associated with the problem. The auxiliary control room is located directly under the control room, but, in accordance with procedure GAP-OPS-01, "Administration of Operations," is not considered to be part of the control room.
TS 6.1.2 states that the SM is responsible for the control room command function while the unit is in the power operating condition, and that, in his absence, an SRO-qualified individual (normally the CRS) shall be designated to assume the control room command function. However, the SM proceeded to the auxiliary control room without turning over the command function, since the CRS was already out of the control room at the time.
The Shift Technical Advisor (STA) promptly recognized that there was no SRO in the control room and contacted the SM. The SM returned to the control room, having been gone for approximately two minutes. As immediate corrective action, warning signs were posted at the control room exits to alert the individual assigned the control room command function not to leave. This issue was entered into the CAP as CR 2008-3688.
The performance deficiency associated with this event was that the SM left the control room without designating an SRO-qualified individual to assume the control room command function, contrary to the requirements of TS 6.1.2.
Analysis.
The finding was greater than minor because it could reasonably be viewed as a precursor to a significant event. Specifically, the absence of SRO oversight during licensed control room activities increases the likelihood of human performance errors, which in turn, increases the likelihood of an initiating event and reduces the effectiveness of event mitigation. The finding has been reviewed by NRC management in accordance with IMC 0609, Appendix M, "Significance Determination Process Using Qualitative Criteria," and was determined to be of very low safety significance (Green) because of the short period that the SM was not present in the control room, and because no initiating events occurred during that time.
The finding had a cross-cutting aspect in the area of human performance because of the ineffective use of human error prevention techniques, in that the SM did not effectively employ self checking before leaving the control room (H.4.a per IMC 0305).
Enforcement.
TS 6.1, "Responsibility," states that the Station Shift Supervisor - Nuclear (SSS, also known as the SM) shall be responsible for the control room command function and that, during absence of the SM from the control room while the unit is in the power operating condition, an individual with an active SRO license shall be designated to assume the control room command function. The definition of areas that are considered to be in the Unit 1 control room, per Administrative Procedure GAP-OPS-01, "Administration of Operations," does not include the auxiliary control room.
Contrary to the above, on April 26, 2008, while the unit was in the power operating condition, the Unit 1 SM left the control room for a period of approximately two minutes without designating an individual with an active SRO license to assume the control room command function. Because this TS noncompliance is of very low safety significance and was entered into the CAP as CR 2008-3688, this violation is being treated as an NCV, consistent with Section VI.A.1 of the NRC Enforcement Policy. (NCV 05000220/2008003-01, Failure to Meet TS Oversight Requirement)
==1R15 Operability Evaluations (71111.15 - Six samples)
a. Inspection Scope
==
The inspectors evaluated the acceptability of operability evaluations, the use and control of compensatory measures, and compliance with TSs. The evaluations were reviewed using criteria specified in NRC Regulatory Issue Summary 2005-20, Revision to Guidance Formerly Contained in NRC Generic Letter 91-18, Information to Licensees Regarding Two NRC Inspection Manual Sections on Resolution of Degraded and Nonconforming Conditions and on Operability, and Inspection Manual Part 9900, Operability Determinations and Functionality Assessments for Resolution of Degraded or Nonconforming Conditions Adverse to Quality or Safety. The inspectors review included verification that the operability determinations were made as specified by Procedure CNG-OP-1.01-1002, Conduct of Operability Determinations / Functionality Assessments.
The technical adequacy of the determinations was reviewed and compared to the TSs, UFSAR, and associated design basis documents (DBDs).
The following evaluations were reviewed:
- CR 2008-3391 concerning an off-normal annunciator for Unit 1 battery charger SBC-161A;
- CR 2008-4844 concerning Unit 1 core spray topping pump 112 differential pressure found to be in the required action range during its quarterly surveillance;
- CR 2008-5174 concerning Unit 2 standby liquid control pump 2SLS*P1A low flow rate during quarterly surveillance test N2-OSP-SLS-Q001;
- CR 2008-2473 concerning the readiness of the Unit 2 instrument air (IA) system for plant startup following corrective actions for an IA pipe rupture that occurred during RFO11;
- CR 2008-3892 concerning voids in the Unit 2 emergency core cooling system (ECCS)and RCIC pump suction lines from the suppression pool; and
- CR 2008-4728 concerning Unit 2 SW pump D differential pressure found to be in the required action range during its quarterly surveillance.
b. Findings
No findings of significance were identified.
==1R18 Plant Modifications (71111.18 - Two samples)
==
.1 Temporary Modifications
a. Inspection Scope
The inspectors reviewed the installation of a temporary seal water supply system that was installed by action request (ACR) 08-3305 for the Unit 1 service and circulating water pumps. The inspectors assessed the 10 CFR Part 50.59 screening evaluation; verified that the change did not adversely affect the systems ability to perform their design functions as described in the UFSAR; that the installation, operation, and removal were consistent with design documents; that the drawings and special procedures were updated as needed; and that post-installation and restoration tests were adequate.
b. Findings
No findings of significance were identified.
.2 Permanent Modifications
a. Inspection Scope
The inspectors reviewed Unit 2 design change package (DCP) N2-01-164, Modify controls for 2TME-PV122 and Eliminate 2TME-PV111. The purpose of this change was to ensure the emergency steam seal system is able to reliably and automatically be placed into service without overpressurization of the system and without impacting condenser vacuum and its resultant turbine trips. The inspectors verified the adequacy of the modification package and that margins to the design and licensing bases requirements of the affected systems were not degraded.
The inspectors verified that component safety classification, instrument setpoints, and supporting electrical and mechanical calculations and analyses were consistent with the design and licensing bases. The inspectors also reviewed the design inputs and assumptions to verify that they were technically appropriate and consistent with the UFSAR. Finally, the inspectors reviewed the affected procedures, drawings, and UFSAR sections to verify that the affected documents were appropriately updated.
For the accessible components associated with the modification, the inspectors walked down the systems to detect possible abnormal installation conditions. The inspectors reviewed applicable CRs associated with the plant modification to ensure that NMPNS was identifying, evaluating, and correcting problems associated with these areas.
b. Findings
No findings of significance were identified.
1R19 Post Maintenance Testing
a. Inspection Scope
The inspectors reviewed the post maintenance tests (PMTs) listed below to verify that procedures and test activities ensured system operability and functional capability. The inspectors reviewed the test procedure to verify that the procedure adequately tested the safety functions that may have been affected by the maintenance activity, that the acceptance criteria in the procedure were consistent with information in the applicable licensing basis and/or DBDs, and that the procedure had been properly reviewed and approved. The inspectors also witnessed the test or reviewed test data, to verify that the test results adequately demonstrated restoration of the affected safety functions.
- Unit 1, WO 08-08520-00 that replaced the master control card for station battery charger SBC-171B. The PMT consisted of a load bank test performed in accordance with the WO.
- Unit 1, WO 08-10671-00 that repaired uninterruptable power supply UPS-172A. The PMT consisted of electrical checks performed in accordance with N1-EPM-UPS-003, UPS 10 Year Maintenance, and a 24-hour confidence run.
- Unit 1, WO 08-07586-00 that repacked 11 service water pump. The PMT consisted of packing run-in and leakoff adjustments, performed in accordance with the WO.
- Unit 1, WO 08-07588-00 that repaired 12 service water Adams strainer. The PMT consisted of verifying normal operation, including backwash, in accordance with N1-OP-18, Service Water System.
- Unit 1, ACR 08-03347 that replaced motor brushes on EDG 103 turbocharger oil pump. The PMT consisted of a 90-minute confidence run performed in accordance with the ACR.
- Unit 2, N2-OSP-EGS-R001, Diesel Generator ECCS Start Division 1/2, performed as a portion of the PMT for various maintenance activities on the Division 1 EDG during RFO11.
- Unit 2, N2-PM-@026, "Diesel Generator Start Following Maintenance - Division I and II," performed as a portion of the PMT for various maintenance activities on the Division 2 EDG during RFO11.
- Unit 2, N2-ISP-MSS-R002, "Main Steam Isolation Valve Leak Rate Test (Reactor Vessel Head Removed)," performed as PMT for 2MSS*AOV6A rework following failure of the initial leak rate test during RFO11.
- Unit 2, N2-OSP-RPV-@003, "Reactor Pressure Vessel and All Class I Systems Leakage Test with the RPV Solid," performed as PMT for vessel reassembly and various other component maintenance performed during RFO11.
- Unit 2, N2-OSP-RMC-@001, "Control Rod Drive Scram Insertion Time Testing,"
performed as PMT for control rod drive replacements performed during RFO11.
- Unit 2, WO 08-05698-00 that repaired a defective level switch for Division 1 EDG fuel oil transfer pump 2EGF*P1C that was causing the pump to run continuously. The PMT was performed in accordance with N2-IPM-GEN-@001, "Safety Related Loop Calibration."
- Unit 2, WO 08-08349-00 that replaced a leaking discharge relief valve on the Division 2 standby liquid control system pump that was causing low system flow. The PMT was performed in accordance with N2-OSP-SLS-Q001, "Standby Liquid Control Pump, Check Valve, Relief Valve Operability Test and ASME XI Pressure Test."
b. Findings
No findings of significance were identified.
==1R20 Refueling and Other Outage Activities (71111.20 - One sample)
a. Inspection Scope
==
The inspectors observed and/or reviewed the following Unit 2 refueling outage activities to verify that operability requirements were met and that risk, industry experience, and previous site-specific problems were considered.
- The inspectors reviewed the outage schedule and procedures, and verified that TS-required safety system availability was maintained and shutdown risk was minimized. The inspectors verified that, when specified by NMPNS procedure NIP-OUT-01, Shutdown Safety, contingency plans existed for restoring key safety functions.
- Through plant tours, the inspectors verified that NMPNS maintained and adequately protected electrical power supplies to safety-related equipment and that TS requirements were met.
- The inspectors verified proper alignment and operation of shutdown cooling and other decay heat removal systems. The verification also included reactor cavity and fuel pool makeup paths and water sources, and administrative control of drain down paths.
- The inspectors verified that requirements for refueling operations were met through refuel bridge observations, control room panel walkdowns, and discussions with Operations Department personnel.
- Before the drywell was closed from general access for startup, the inspectors performed an as-left walkdown to identify evidence of reactor coolant system leakage and verify the condition of drywell coatings, structures, valves, piping, supports, and other equipment in areas where maintenance was completed. The inspectors also verified that no debris was left in the drywell that could affect the performance of the emergency core cooling system suction strainers.
- The inspectors observed portions of the reactor startup following the outage, and verified through plant walkdowns, control room observations, and surveillance test reviews that safety-related equipment specified for mode change was operable.
b. Findings
Introduction.
A self-revealing Green finding was identified on April 18, 2008, when failure to take appropriate corrective actions to address corrosion products in the IA system in a timely manner led to an accumulation of water in the Unit 2 IA system. As a result, water intrusion into the air operator for the 'B' reactor feedwater pump recirculation valve caused the valve to open during plant power ascension, causing a reduction in feedwater flow to the reactor and thereby challenging plant stability.
Description.
On April 18, 2008, Unit 2 was performing power ascension after startup from RFO11. At approximately 45 percent power, operators placed a second reactor feedwater pump, 2FWS-P1A, in service. Shortly thereafter, operators received indication that the normally closed recirculation valve for the other operating reactor feedwater pump, 2FWS-P1B, had failed open. Because reactor feedwater demand was still within the capacity of a single pump, this did not result in a significant transient; however, if it had happened at full power, it would have resulted in an automatic scram due to low reactor water level. As immediate corrective action, operators isolated the recirculation valve.
This issue was entered into the CAP as CR 2008-3471.
Investigation revealed that the 2FWS-P1B recirculation valve had failed open due to water in the air actuator. The cause of the water in the IA system was determined to be due to plugging of the air dryer condensate drain system by corrosion products. This allowed water to back up into the IA system, resulting in high humidity air throughout the system, from which water could then condense at various points in the system (in this case, the 'B' reactor feedwater pump recirculation valve air actuator). Actions to address the water in the IA system included placing the other IA dryer in service, periodic blowdowns at various locations in the system and daily dew point monitoring.
Corrosion in the IA system was a known problem before this event. In December 2007, the 'A' IA dryer was found to have heavy internal corrosion, and the condensate drain trap inlet strainer drain valve was found to be packed with corrosion products. The corrosion products were cleaned out and the 'B' IA dryer was scheduled to be examined for similar conditions during the week of April 28, 2008. However, no near-term corrective actions (such as periodic blowdowns of the air dryer) were taken to address continued use of the
'B' IA dryer. The 'B' IA dryer was in service at the time of the 'B' reactor feedwater pump recirculation valve failure and had been in service for the duration of RFO11.
The performance deficiency associated with this event was that corrective action to address corrosion products in the IA system were ineffective and resulted in an event that affected plant stability.
Analysis.
The finding was greater than minor because it was associated with the equipment performance attribute of the Initiating Events cornerstone and adversely affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. The finding was evaluated in accordance with IMC 0609, Attachment 4, and determined to be of very low safety significance (Green) per the SDP Phase one determination because the finding did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions would not be available, and did not screen as potentially risk significant due to external events.
The finding had a cross-cutting aspect in the area of problem identification and resolution because NMPNS did not take appropriate corrective actions to address corrosion products in the IA system in a timely manner (P.1.d per IMC 0305).
Enforcement.
No violation of regulatory requirements occurred. The inspectors determined that the finding did not represent a noncompliance issue because it occurred on non safety-related balance of plant equipment. (FIN 05000410/2008003-02, Untimely Corrective Action for IA System Corrosion Resulted in Reactor Feedwater Valve Malfunction)
==1R22 Surveillance Testing (71111.22 - Six samples)
a. Inspection Scope
==
The inspectors witnessed performance of and/or reviewed test data for risk-significant surveillance tests (STs) to assess whether the components and systems tested satisfied design and licensing basis requirements. The inspectors verified that test acceptance criteria were clear, demonstrated operational readiness and were consistent with the DBDs; that test instrumentation had current calibrations and the range and accuracy for the application; and that tests were performed, as written, with applicable prerequisites satisfied. Upon test completion, the inspectors verified that equipment was returned to the status specified to perform its safety function.
The following STs were reviewed:
- N1-ST-Q2, Control Rod Drive Pump Flow Rate Test;
- N1-ST-Q3, High Pressure Coolant Injection Pump and Check Valve Operability Test;
- N1-ST-Q1D, Core Spray 122 Pump and Valve Operability Test;
- N2-OSP-EGS-R004, "Operating Cycle Diesel Generator Simulated Loss of Offsite Power with ECCS Division I and II;"
- N2-OSP-RHS-Q@006, "RHR System Loop C Pump and Valve Operability Test and System Integrity Test; and
- N2-OSP-CSL-Q@002, "LPCS Pump and Valve Operability and System Integrity Test."
b. Findings
Introduction.
A self-revealing Green NCV of 10 CFR Part 50, Appendix B, Criterion XVI, "Corrective Action," was identified on March 22, 2008, when the Unit 2 Division I EDG service water (SW) return isolation valve failed to fully open following a start of the Division I EDG, due to age-related failure of the J-10 relay in the MOV control circuit. The susceptibility of J-10 relays to age-related failure had been previously identified; however, NMPNS did not take action to establish a maintenance strategy to replace these relays prior to failure.
Description.
On March 22, 2008, Unit 2 performed surveillance procedure N2-OSP-EGS-R004, "Operating Cycle Diesel Generator Simulated Loss of Offsite Power with ECCS Division I and II," for Division I only. This surveillance begins with a simulated loss of off-site power to the Divisional switchgear, which is then reenergized approximately 10 seconds later by its respective EDG. When the Division I EDG started, the normally closed SW return isolation valve, 2SWP*MOV66A, started to open (as designed) but then stopped due to a loss of control power to the MOV. At the time of failure, SW flow to the Division I EDG was 1020 gallons per minute (gpm); this was greater than the minimum required SW flow of 800 gpm, but less than the nominal 1200 gpm flow.
Investigation revealed that the J-10 relay had short circuited, which caused the MOV control power fuse to open. This resulted in a loss of power to the MOV. The cause of the J-10 relay failure was age-related heat degradation as a result of the relay being normally energized. The heat degrades the wiring insulation, as well as the plastic components in the relay's operating mechanism. Deformation of the plastic armature carriage restricts motion of the armature assembly, resulting in an armature gap being maintained after the relay is energized. This results in greater than normal current flow, which in turn, results in breakdown of the coil insulation and relay failure due to either an open circuit, or (as in this case) a short circuit.
The susceptibility of J-10 relays to age-related degradation had been previously identified in NRC Information Notice (IN) 92-27, "Thermally Induced Accelerated Aging and Failure of ITE/Gould A.C. Relays used in Safety-Related Applications," and IN 92-27, Supplement 1, dated March 21, 1997. NMPNS had reviewed this information in CR 1997-1171, but had incorrectly concluded that J-10 relays had a passive function. As a result, no maintenance strategy had been established for inspection, testing, or periodic replacement.
As immediate corrective action, the Division I EDG was declared inoperable pending repair of 2SWP*MOV66A. The issue was entered into the CAP as CR 2008-2203. Other J-10 relay failures during the performance of N2-OSP-EGS-R004 for both Divisions I and II led to an extent of condition review through CR 2008-2976.
The performance deficiency associated with this event was that NMPNS did not correctly evaluate the effects of age-related degradation of a component that could lead to failure of safety-related equipment. This resulted in failure of a SW valve to fully open when required, which could have prevented the Division I EDG from performing its safety function.
Analysis.
The finding was greater than minor because it was associated with the equipment performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding was evaluated in accordance with IMC 0609, Attachment 4, and determined to be of very low safety significance (Green) per the SDP Phase one determination because the finding was not a design or qualification deficiency, did not represent a loss of a system/train safety function, and did not screen as potentially risk significant due to external events.
Enforcement.
10 CFR Part 50, Appendix B, Criterion XVI, "Corrective Action," states, in part, "Measures shall be established to assure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and equipment, and nonconformances are promptly identified and corrected." Contrary to the above, from 1997 until 2008, NMPNS did not establish measures to assure that thermally induced accelerated aging of J-10 relays at Unit 2 would be promptly identified and corrected, in that J-10 relays were evaluated to be passive components, and consequently, no maintenance strategy was established for inspection, testing, or periodic replacement. As a result, on March 22, 2008, the Division I EDG SW return isolation valve, 2SWP*MOV66A, failed to fully open when required. Because this noncompliance is of very low safety significance and was entered into the CAP as CR 2008-2203, this violation is being treated as an NCV, consistent with Section VI.A.1 of the NRC Enforcement Policy. (NCV 05000410/2008003-03, Failure to Appropriately Evaluate the Effect of Accelerated Aging of J-10 Relays)
Cornerstone: Emergency Preparedness
1EP6 Drill Evaluation (71114.06 - One sample)
a. Inspection Scope
The inspectors observed control room operator emergency plan response actions during the Unit 2 evaluated LORT scenario on May 21, 2008. The inspectors verified that emergency classification declarations and notifications were completed in accordance with 10 CFR Part 50.72, 10 CFR Part 50 Appendix E, and emergency plan implementing procedures.
b. Findings
No findings of significance were identified.
RADIATION SAFETY
Cornerstone: Public Radiation Safety
2PS3 Radiological Environmental Monitoring Program (REMP) and Radioactive Materials Control Program (71122.03 - 10 samples)
a. Inspection Scope
The inspectors reviewed the most current Annual Environmental Monitoring Report and licensee assessment results to verify that the REMP was implemented as required by TS and the offsite dose calculation manual (ODCM). The inspectors reviewed the report for changes to the ODCM with respect to environmental monitoring, commitments in terms of sampling locations, monitoring and measurement frequencies, land use census, interlaboratory comparison program, and analysis of data. The inspectors reviewed the ODCM to identify environmental monitoring stations. The inspectors reviewed licensee self assessments, audits, licensee event reports, and interlaboratory comparison program results. The inspectors reviewed the UFSARs for information regarding the environmental monitoring program and meteorological monitoring instrumentation. The inspectors reviewed the scope of the licensees audit program to verify that it meets the requirements of 10 CFR Part 20.1101(c).
The inspectors walked-down the air sampling stations, groundwater monitoring stations, milk sampling stations and the thermoluminescence dosimeter (TLD) monitoring stations to determine whether they were located as described in the ODCM and to determine the equipment material condition.
The inspectors observed the collection and preparation of environmental samples (e.g.,
milk). The inspectors verified that environmental sampling was representative of the release pathways as specified in the ODCM and that sampling techniques were in accordance with procedures.
Based on direct observation and review of records, the inspectors verified that the meteorological instruments were operable, calibrated, and maintained in accordance with guidance contained in the UFSARs, NRC Safety Guide 23, and licensee procedures. The inspectors verified that the meteorological data readout and recording instruments in the control room and at the tower were operable. The inspectors compared readout data (i.e.,
wind speed, wind direction, and delta temperature) in the control room and at the meteorological tower to identify if there was any line loss differences.
The inspectors reviewed each event documented in the Annual Environmental Monitoring Report which involved a missed sample, inoperable sampler, lost TLD, or anomalous measurement for the cause and corrective actions. The inspectors conducted a review of the licensees assessment of any positive sample results (i.e., licensed radioactive material detected above the lower limits of detection (LLDs)). The inspectors reviewed the associated radioactive effluent release data that was the likely source of the released material.
The inspectors reviewed any significant changes made by the licensee to the ODCM as the result of changes to the land census or sampler station modifications since the last inspection. The inspectors reviewed technical justifications for any changed sampling locations. The inspectors verified that the licensee performed the reviews required to ensure that the changes did not affect its ability to monitor the impacts of radioactive effluent releases on the environment.
The inspectors reviewed the calibration and maintenance records for air samplers and composite water samplers. The inspectors reviewed calibration records for the environmental sample radiation measurement instrumentation. The inspectors verified that the appropriate detection sensitivities with respect to TS/ODCM were utilized for counting samples. The inspectors reviewed quality control charts for maintaining radiation measurement instrument status and actions taken for degrading detector performance.
The inspectors reviewed the results of Constellations interlaboratory comparison program to verify the adequacy of environmental sample analyses performed by Constellation.
The inspectors reviewed Constellations quality control evaluation of the interlaboratory comparison program and the corrective actions for any deficiencies. The inspectors reviewed Quality Assurance (QA) audit results of the program to determine whether Constellation met the TS/ODCM requirements.
The inspectors observed several locations where Constellation monitors potentially contaminated material leaving the radiologically controlled area (RCA), and inspected the methods used for control, survey, and release from these areas. When possible, the inspectors observed the performance of personnel surveying and releasing material for unrestricted use to verify that the work was performed in accordance with plant procedures.
The inspectors verified that the radiation monitoring instrumentation was appropriate for the radiation types present and was calibrated with appropriate radiation sources. The inspectors reviewed Constellations criteria for the survey and release of potentially contaminated material. The inspectors verified that there was guidance on how to respond to an alarm which indicates the presence of licensed radioactive material. The inspectors reviewed Constellations equipment to ensure the radiation detection sensitivities were consistent with the NRC guidance contained in IE Circular 81-07 and IE Information Notice 85-92 for surface contamination and HPPOS-221 for volumetrically contaminated material. The inspectors reviewed Constellations procedures and records to verify that the radiation detection instrumentation was used at its typical sensitivity level based on appropriate counting. The inspectors verified that Constellation had not established a release limit by altering the instruments typical sensitivity through such methods as raising the energy discriminator level or locating the instrument in a high radiation background area.
The inspectors reviewed Constellations Licensee Event Reports, Special Reports, audits, and self-assessments related to the radiological environmental monitoring program performed since the last inspection. The inspectors determined if identified problems were entered into the corrective action program for resolution.
The inspectors reviewed corrective action reports affecting environmental sampling, sample analysis, or meteorological monitoring instrumentation. The inspectors interviewed staff and reviewed documents to determine if the following activities were being conducted in an effective and timely manner commensurate with their importance to safety and risk:
- Initial problem identification, characterization, and tracking;
- Disposition of operability/reportability issues;
- Evaluation of safety significance/risk and priority for resolution;
- Identification of repetitive problems;
- Identification of contributing causes;
- Identification and implementation of effective corrective actions;
- Resolution of NCVs tracked in corrective action system; and
- Implementation/consideration of risk significant operational experience feedback.
For repetitive deficiencies or significant individual deficiencies in problem identification and resolution identified above, the inspectors determined if Constellations self-assessment activities were also identifying and addressing these deficiencies.
b. Findings
No findings of significance were identified.
OTHER ACTIVITIES
4OA1 Performance Indicator Verification (71151 - Four samples)
a. Inspection Scope
The inspectors sampled NMPNS submittals for the performance indicators (PIs) listed below. To verify the accuracy of the PI data reported during that period, the PI definition guidance contained in Nuclear Energy Institute (NEI) 99-02, "Regulatory Assessment Indicator Guideline," Revision 5, was used to verify the basis in reporting for each data element.
Cornerstone: Barrier Integrity
The inspectors reviewed operator logs, plant computer data, and daily sampling and surveillance procedure results to verify the accuracy of NMPNSs reported reactor coolant system performance indicators from July 2007 to March 2008.
- Unit 1 reactor coolant system leak rate;
- Unit 1 reactor coolant system specific activity;
- Unit 2 reactor coolant system leak rate; and
- Unit 2 reactor coolant system specific activity.
b. Findings
No findings of significance were identified.
4OA2 Identification and Resolution of Problems (71152 - Two samples)
.1 Review of Items Entered into the CAP
a. Inspection Scope
As specified by Inspection Procedure 71152, Identification and Resolution of Problems, and in order to help identify repetitive equipment failures or specific human performance issues for follow-up, the inspectors performed a daily screening of items entered into NMPNSs CAP. In accordance with the baseline inspection procedures, the inspectors also identified selected CAP items across the initiating events, mitigating systems, and barrier integrity cornerstones for additional follow-up and review. The inspectors assessed the threshold for problem identification, the adequacy of the cause analyses, extent of condition review, operability determinations, and the timeliness of the specified corrective actions.
b. Findings
No findings of significance were identified.
.2 Semi-Annual Review to Identify Trends
a. Inspection Scope
As specified by Inspection Procedure 71152, "Identification and Resolution of Problems,"
the inspectors reviewed NMPNS's CAP and associated documents to identify trends that could indicate significant safety issues. The inspectors' review focused on repetitive equipment and corrective maintenance issues but also considered the results of daily inspector CAP item screening. The review included issues documented outside the normal CAP in system health reports, quality performance and assurance assessment reports, maintenance rule status reports, the operator workaround lists, and the 2008 top ten issues list. The inspectors' review considered the six month period of January 2008 through June 2008.
b.
Assessments and Observations
No findings or observations of significance were identified.
.3 Annual Sample - Review of Corrective Actions Associated with a Non-Conservative EAL
High Drywell Radiation Threshold Calculation Error
a. Inspection Scope
The inspectors reviewed NMPNS=s actions in response to its discovery of a non-conservative emergency action level (EAL) threshold found while reviewing the potential impact of an Alternate Source Term change on EALs. NMPNS discovered that a previous calculation caused the General Emergency EAL 1.3.3, Drywell Radiation, threshold value to correspond to 100 percent core damage as opposed to 20 percent core damage, which caused the value to be non-conservative. The inspectors also reviewed NMPNSs EAL Technical Bases as well as the erroneous calculation causing the non-conservative EAL threshold. In addition, the inspectors interviewed applicable members of NMPNSs staff including the Emergency Preparedness Manager and Licensing Director.
b.
Assessment and Observations
The inspectors determined there was a licensee identified violation (see Section 4OA7).
4OA3 Followup of Events and Notices of Enforcement Discretion (71153 - One sample)
.1 Unit 1 Loss of Offsite Power
a. Inspection Scope
At 6:37 a.m. on May 13, Unit 1 operators removed one of two 115 kV offsite power lines (line 1) from service for planned maintenance. Later that morning, at 8:06 a.m., power was lost to the remaining 115 kV offsite power line (line 4). This resulted in a loss of electrical power to the vital AC switchgear and non-vital power board (PB) 101. EDGs 102 and 103 both automatically started as designed and re-powered the vital AC switchgear. RRP 13 tripped as a result of the loss of PB 101, which caused reactor power to lower to 92 percent. The Unit 1 Shift Manager declared an Unusual Event (UE)emergency action level at 8:25 a.m., based on a loss of 115 kV offsite power for greater than 15 minutes (EAL 6.1.1). Unit 2 was not affected.
The cause of the loss of power to line 4 was not immediately known. However, maintenance had not yet commenced on line 1, and Unit 1 operators coordinated with the grid operator to rapidly return it to service. At 10:22 a.m., line 1 was restored and Unit 1 terminated the UE. The loss of line 4 was later determined to have been due to an off-site equipment failure, and therefore, no NMPNS performance deficiency was identified. Line 4 was returned to service on May 16.
b. Findings
No findings of significance were identified.
4OA5 Other Activities
.1 Review of the Use of Overtime at NMPNS
a. Inspection Scope
The inspectors reviewed the use of plant staff overtime at NMPNS to verify that procedures for control of overtime were consistent with TS requirements and were being effectively implemented.
b. Findings
1. Deficient Control of Plant Staff Overtime
Introduction.
The inspectors identified a Green non-cited violation of Unit 1 TS 6.2.2.d and Unit 2 TS 5.2.2.e for not properly implementing procedures for controlling plant staff work hours of personnel performing safety-related activities. The plant manager authorized over 400 overtime deviations for Operations personnel to work greater that TS work hour limits for routine outage support activities during NMPNS outages and other reasons during the last 12 months.
Description.
TS 6.2.2.d and TS 5.2.2.e require, in part, that overtime for staff performing safety-related functions be limited. These TSs were developed to meet commitments made by the station is response to NRC Generic Letter (GL) 82-12, Nuclear Power Plant Staff Working Hours, dated June 15, 1982. The Unit 2 TS specifies, in part, that during extended periods of shutdown for refueling, individuals should not be permitted to work more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in any 7-day period, and specifically states that these guidelines shall be followed during refueling outages and that routine deviations to these guidelines shall not be authorized.
The inspectors observed that, since 2006, there has been a significant increasing trend in the use of overtime deviations in the Operations Department. In 2006, there were a total of 15 deviations approved. In the first 6 months of 2007 this number rose to 96 (not including 78 deviations due to an inclement weather event), in the second six months of 2007 there were 159 deviations authorized, and in the first four months of 2008 there were 256 authorized deviations. It was also noted that, in many cases, the reasons supplied for the deviations to be given were outage support, attending meetings, shift coverage, and other reasons which would not constitute very unusual circumstances.
As such, these deviations would be prohibited by NMPNS procedures and TSs.
The inspectors also noted that, in many cases, groups of up to 29 personnel were authorized deviations for a common reason. NMPNS procedures reference NRC GL 82-12, which states: Recognizing that very unusual circumstances may arise requiring deviation from the above guidelines, such deviation shall be authorized by the plant manager or his deputy, or higher levels of management. The paramount consideration in such authorization shall be that significant reductions in the effectiveness of operating personnel would be highly unlikely. Since deviations were being granted for large groups, each individual may not have been effectively evaluated and monitored for fitness for duty due to fatigue. Therefore, the intent of the deviation provision of GL 82-12, and thus the station procedures, may not have been met.
Unit 1 TSs state, Controls shall be included in the procedures to require a periodic independent review be conducted to ensure that excessive hours have not been assigned. Unit 2 TSs state, Controls shall be included in the procedures such that individual overtime shall be reviewed monthly by a specified corporate officer or a designee to ensure that excessive hours have not been assigned. These reviews were not effective in identifying this increasing trend of reliance on overtime deviations; that reasons for granting deviations were not in accordance with station procedures, GL 82-12 guidelines, or TS; and that the granting of overtime deviations for a group of operators is not consistent with the guidance of GL 82-12 or station procedures.
The inspectors also reviewed group overtime work hours for Operations Department personnel and found that average group overtime work hours for Operations Department since 2006 were approximately 20 percent, with a peak in excess of 40 percent in March and April of 2008. NMPNS TSs specify that adequate shift coverage shall be maintained without routine heavy use of overtime.
The inspectors determined that failure to properly implement procedures to limit work-hours for plant staff performing safety-related functions in accordance with TS 6.2.2.d and 5.2.2.e was a performance deficiency. Corrective actions were being developed to increase the number of qualified operators.
Analysis.
The violation affected the Mitigating Systems cornerstone and is more than minor because, if left uncorrected, it would become a more significant safety concern, in that the excessive work hours would increase the likelihood of human errors during refueling outage activities and response to plant events. The finding has been reviewed by NRC management in accordance with IMC 0609, Appendix M, Significance Determination Process Using Qualitative Criteria. The resulting increased likelihood of human error would adversely affect the stations defense-in-depth. However, the violation was determined to be of very low safety significance (Green), because no significant events or human performance issues were directly linked to personnel fatigue as a result of the hours worked.
The issue had a cross-cutting aspect in the area of human performance, because the licensee did not use conservative assumptions in decision making, in that, the consequences of the high number of overtime deviations were not fully considered and the possible unintended consequences evaluated. Specifically, plant management decided to change the manner in which existing plant procedures where interpreted and did not evaluate the impact of this decision on TS compliance and the increased potential for fatigue related fitness for duty issues (H.1.b per IMC 0305).
Enforcement.
Unit 1 TS 6.2.2.d and Unit 2 TS 5.2.2.e require that procedures be developed and implemented to limit the hours worked by staff performing safety-related functions. Recognizing that unforeseen problems may arise, requiring deviation from this guideline, such deviation shall be authorized in advance by the plant manager or his deputy, or higher levels of management. Routine deviation from the guidelines is not authorized.
Contrary to the above, procedures for the control of plant staff overtime were not properly implemented to limit work hours in accordance with TS 6.2.2.d and 5.2.2.e.
Consequently, during various time periods between July 2007 and April 2008, the plant manager or designated manager authorized over 400 overtime deviations for licensee employees from the Operations Department (including reactor operators, senior reactor operators, auxiliary operators, and the emergency response organization members) for reasons not permitted by NMPNSs TSs. The majority of these individuals worked more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> during a 7-day period for outage support. These constitute routine deviations of working hour guidelines. Because this violation was of very low safety significance, was not repetitive or willful, and it was entered into NMPNSs corrective action program (CR 2008-4021), this violation is being treated as an NCV, consistent with section VI.A.1 of the NRC Enforcement Policy. (NCV 05000220 & 05000410/2008003-04, Failure to Properly Control Operations Staff Overtime)
2. Repetitive Improper Authorization and Evaluation of Overtime
Introduction.
A Green NCV of Unit 1 TS 6.2.2.d and Unit 2 TS 5.2.2.e was identified by the inspectors for a recurring trend of operations personnel being required to stand 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> shifts in order to provide adequate shift coverage due to foreseeable shift absences.
There were eight occurrences between May 2007 and May 2008. Several of these overtime deviations were not properly authorized in accordance with station procedures as required by TSs.
Description.
From May 2007 to May 2008, there were eight occurrences of operations department personnel being authorized overtime deviations and standing 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> shifts in order to ensure the plant met TS required shift manning requirements. Four occasions were for Unit 2 (5/11/07, 8/24/07, 8/29/07, 2/6/08), three were for Unit 1 (7/21/07, 11/19/07, 5/6/08) and one was for a dual unit fire brigade leader (2/29/08). Seven of the deviations were for non-licensed operator (NLO) positions and one of the deviations was for a licensed reactor operator (RO) position. All of these deviations were granted for irregular, but nonetheless foreseeable difficulties (i.e., an individual calling in sick) during non-outage plant conditions. The NMPNS administrative procedures required by TSs 6.2.2.d and 5.2.2e, permit deviations of TS work hours guidelines of no more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> consecutive and no more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, for very unusual circumstances, provided that adequate measures are taken to ensure the operators fitness for duty (FFD). In each case, FFD evaluations were conducted and compensatory measures were put in place to enhance monitoring the operator and ensure FFD.
Nevertheless, the plants' defense in depth was weakened during these occasions, since the personnel being compensated for were part of the minimum allowable shift staff, and, as such, constituted a part of the first line of defense during an event and would be relied on to implement immediate mitigative actions.
Several of the overtime deviations were improperly approved or documented. In two cases, a deviation was authorized for a portion of the extra shift, but a relief operator was not able to support the watch and the operator had to remain on shift. Authorization for the additional six hours was not obtained. In several other cases, overtime deviation forms did not include required information such as reason for deviation and safety-related tasks to be performed, and in one case the overtime deviation form could not be found.
Proper documentation and approval of overtime prior to performing overtime in excess of TS 6.2.2.d and TS 5.2.2.e guidelines is required by TS.
Unit 1 TSs state, Controls shall be included in the procedures to require a periodic independent review be conducted to ensure that excessive hours have not been assigned. Unit 2 TSs state, Controls shall be included in the procedures such that individual overtime shall be reviewed monthly by a specified corporate officer or a designee to ensure that excessive hours have not been assigned. These reviews were not effective in identifying this repeating trend of reliance upon 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> shifts in order to meet technical specification manning requirements during non-outage periods, and that the deviations were not completed and retained in accordance with station procedures. In fact, a Nuclear Safety and Review Board (NSRB) report only indentified two of the eight instances, and senior plant management stated they were unaware of this trend.
Operations staff, plant management, and corporate review failed to identify and correct a significant adverse trend. While a series of events could occur which result in an operator having to perform a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> shift, this should be a rare occurrence. The risk of accidents due to fatigue related events increases significantly for a worker working greater than 16 consecutive hours. The workers FFD due to excessive fatigue would be in doubt and they should not be relied upon to perform safety related tasks unless compensatory measures have been put in place. Having eight occurrences in a 12 month period indicates that NMPNS has not identified and taken corrective actions to address an underlying problem, and would indicate the administrative procedures and policies in place to limit the working hours of unit staff who perform safety related functions were not effective in preventing this issue.
The failure to properly authorize, document, and evaluate overtime deviations for eight occurrences of operations personnel being authorized to, and stand, 24 consecutive hours of duty for foreseeable shift absences is a performance deficiency. Corrective actions are being developed to increase the number of qualified operators.
Analysis.
The violation affected the Mitigating Systems cornerstone and is more than minor because, if left uncorrected, it would become a more significant safety concern.
The excessive work hours would increase the likelihood of human errors during plant activities and response to plant events. The finding has been reviewed by NRC management in accordance with IMC 0609, Appendix M, Significance Determination Process Using Qualitative Criteria. The resulting increased likelihood of human error would adversely affect the stations defense-in-depth. However, the violation was determined to be of very low significance (Green), because no significant events or human performance issues were directly linked to personnel fatigue as a result of the hours worked.
This issue has a cross-cutting aspect in the area of problem identification and resolution.
Specifically, NMPNS failed to periodically trend and assess information from the CAP and other assessments in the aggregate to identify programmatic and common cause problems (P.1.b per IMC 0305).
Enforcement.
Unit 1 TS 6.2.2.d and Unit 2 TS 5.2.2.e require that procedures be developed and implemented to limit the hours worked by staff performing safety-related functions. Any deviation from the above guidelines shall be authorized by the plant manager or a designee, in accordance with approved administrative procedures, with documentation of the basis for granting the deviation. Controls shall be included to require a periodic review to ensure that excessive hours have not been assigned. Routine deviation from the guidelines is not authorized.
Contrary to the above, eight instances were identified where plant personnel performed safety-related work in excess of the overtime limits established by TS without obtaining proper authorization and/or documenting the overtime deviation, and a trend of excessive reliance upon 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> shifts due to foreseeable shift absences during non-outage periods was not identified and corrected. However, because this failure to adequately implement the TS required administrative procedure for controlling overtime is considered to be of very low safety significance and has been entered into Constellations corrective action program as CR 2008-3879, this violation is being treated as an NCV, consistent with Section VI.A.1 of the NRC Enforcement Policy. (NCV 05000220 & 5000410/2008003-05, Repetitive Improper Authorization and Evaluation of Overtime Deviations)
4OA6 Meetings, including Exit
Exit Meeting Summary
The inspectors presented the inspection results to Mr. Keith Polson and other members of NMPNS management on July 16, 2008. NMPNS acknowledged that no proprietary information was involved.
4OA7 Licensee Identified Violations
The following violation of very low safety significance (Green) was identified by NMPNS and is a violation of NRC requirements which meet the criteria of Section VI of the NRC Enforcement Policy, NUREG-1600, for being dispositioned as an NCV.
10 CFR Part 50.54(q) requires licensees to follow and maintain in effect an emergency plan which meets the standards of 10 CFR Part 50.47(b). Nine Mile Points Site Emergency Plan states that emergency action level values are based upon criteria established under NUMARC/NESP-007, Methodology for Development of Emergency Action Levels. NUMARC/NESP-007 directs the licensee to use site-specific values for containment radiation levels corresponding to 20 percent fuel clad damage for the General Emergency EAL 1.3.3, Drywell radiation, threshold value. Contrary to the above, NMPNS identified that the value used was based on an erroneous calculation, completed in March of 1994, that assumed 100 percent fuel clad damage as opposed to 20 percent. This miscalculation led to a non-conservative value for EAL 1.3.3 being in place because the classification would not be made until the containment radiation levels reached a value corresponding to 100 percent core damage.
Upon discovery of this error, in February of 2008, NMPNS took immediate action to correct the drywell area radiation value and issued CR 2008-1569, which initiated a root cause evaluation as well as a technical evaluation to understand what redundant EAL thresholds may have been exceeded before the drywell area radiation threshold. The inspectors determined that the error associated with this EAL parameter was of very low safety significance because it would not have delayed the declaration of a General Emergency due to redundant EALs based upon vessel water level that would have been exceeded prior to the drywell radiation monitor reaching its stated threshold.
ATTACHMENT:
SUPPLEMENTAL INFORMATION
KEY POINTS OF CONTACT
Licensee Personnel
- S. Belcher, Plant Manager
- W. Byrne, Manager, Nuclear Security
- R. Dean, Director, Quality and Performance Assessment
- J. Kaminski, Manager, Emergency Preparedness
- J. Krakuszeski, Manager, Operations
- J. Laughlin, Manager, Engineering Services
- K. Polson, Vice President
- J. Schultz, Chemistry Supervisor, J.A. FitzPatrick Nuclear Power Plant
- T. Shortell, Manager, Training
- S. Sova, Manager, Radiation Protection
- K. Stoffle, Environmental Support Supervisor
- J. Stone, Chemistry Technician
- T. Syrell, Director, Licensing
LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED
Opened and Closed
Failure to Meet TS Oversight Requirement (Section 1R13)
Untimely Corrective Action for IA System Corrosion Resulted in Reactor Feedwater Valve Malfunction (Section 1R20)
Failure to Appropriately Evaluate the Effect of Accelerated Aging of J-10 Relays (Section 1R22)
- 05000220&410/2008003-04 NCV
Failure to Properly Control Operations Staff Overtime (Section 4OA5)
- 05000220&410/2008003-05 NCV
Repetitive Improper Authorization and Evaluation of Overtime Deviations (Section 4OA5)
Closed
None.
Discussed
None.