Text

U.

S.

NUCLEAR REGULATORY COMMISSION

REGION V

Report No. 50-397/87-16 Docket No.

50-397 License No.

NPF-21 Licensee:

Washington Public Power Supply System P.

0.

Box 968 3000 George Washington Way Richland, Washington 99352 Facility Name:

WNP-2 Inspection at: In-office Inspection Conducted:

May 26, 1987 Inspector:

C,

G.

H.

Hamada, Radiation Laboratory Specialist Approved by:

G.

P.

u

, Chief Facilit Radiological Protection Section

~Summer:

In-office Ins ection of Ma

1987 Re ort No. 50-397/87-16)

~d:

'M spiked solution provided by the NRC.

(Open Item No. 86-35-01)

8=2)- 8'7 Date Signed Date Signed Results:

No items of noncompliance were identified in the areas examined.

8706090411 870602 PDR ADOCK 050003'P7

PDR

DETAILS 1.

Discussion The WNP-2 chemistry laboratory recently analyzed a spiked solution containing radionuclides which require chemical isolation prior to their quantification.

This solution was provided by the NRC to test laboratory capability to analyze beta emitters and soft x-ray emitters.

The results are tabulated below:

Nucl ide WNP-2

~Ci /ml Certificate Value H-3 Fe-55 Sr-89 Sr-90 1.08 E-4 7. 40,E-5

.1.07 E-4 1.19 E-5 9.11 E-5 5.57 E"5 1.25 E-4 l. 13 E-5 The results indicate adequate agreement for this series of measurements.

With this report, Open Item No. 86-35-01 is closed.

2.

Exit Interview The results were discussed with Mr.

L.

D. Morrison, WNP-2 Chemistry Supervisor over the telephone.