SALP BOARD REPORT

!

U.S. NUCLEAR REGULATORY COMMISSION

REGION V

SYSTEMATIC ASSESSMENT OF. LICENSEE PERFORMANCE

,

50-397/86-03 WASHINGTON PUBLIC POWER SUPPLY SYSTEM WNP-2

'

FEBRUARY 1, 1985 THROUGH JANUARY 31, 1986 i

,

i 0607180017 860702 PDR ADOCK 00000397 G

PDR

._.

_

_

-

...,

.

- -

~.

.

-

. ~.

- -- --.

-

- -

- -

....

-...

.

i

'

.

!

'

SUMMARY

.

Inspections Conducted *

. Enforcement Items **

Functional Inspection * Percent Severity Level-Area.

Ilours of Effort I II III IV V A.

Plant Operations 1586

2 B.

Radiologic ~l Controls 234

1

a C.

Maintenance 137

2 D.

Surveillance '

237

1

E.

Fire Protection

2

1 F.

Emergency Preparedness 610

G.

Security -

58'

H.

~0utages

,'238

1

I.

tQuality-Programs /

. 5 4d1

Administrative

-

.

.

+>

,,

,.

,

J.

Licensing Activities 340'

'

,'

K.

Training / Qualification 111

Effectiveness

'

~

"

-J

,

,

.-

_ _

g

_ _

~

Totals.-,

'4017

.

100

0

9 5

Data reflect Inspection Report-Nos. 85-07, 85-08, and 85-10 through 86-04. Allocations of inspection hours vs. functional areas are approximations based.upon inspection report data, and~ include onsite and in-office inspectica efforts.

-

Severity levels are discussed in 10 CFR 2, Appendix C.

No deviations were identified during.this SALP perio.

TABLE _2 ENFORCEMENT ITEMS Inspection Severity Functional Report No.

Subject Level Area 85-05 Two fire brigade members did not V

E attend required drills Flammable and combustible material IV E

was present in an unauthorized location 85-11 Inadequate implementation of Measuring IV C

and Test Equipment Controls The full CNSRB were not reviewing V

I all safety evaluations of procedure changes, modifications, tests and experiments Four containment isolation valves IV A

requiring monthly verification of i

closure were no' verified for a two month period 85-17 Failure to properly establish and V

D implement code requirements regarding' evaluation of valve stroke times 85-20 Failure to document appro' val of IV H

, deviation _from overtime requirements prior to exceeding overtime criteria Failure to adequately post and label IV B

radiation area t

Failure to implement procedure to IV C

ensure proper tool control 85-22 Fire protection procedures not IV E

fully implemented, multiple examples 85-29 Failure to adequately post V

B radioactive material storage area 85-30 Lack of procedure adherence while IV A

adjusting suppression pool level

.-

..

..

.-

-

.

,

TABLE 2 - ENFORCEMENT ITEMS (Cont'd)

Inspection Severity Functional Report No.

Subject Level Area 85-36-Improper maintenance on strip boxes IV D

and junction boxes following surveillance 85-37 Failure to follow administrative V

D procedures for control of locks on secured valves

.

s

.

i

,

_ _.

.

-

TABLE 3 SYNOPSIS OF LICENSEE EVENT REPORTS (LERs)

Functional SALP Cause Code *

Area A

B C

D E

X Totals A.

Plant Ops

1

1

3

B.

Rad. Controls

-

-

-

-

-

-

C.

Maintenance

3

-

3

-

D.

Surveillance

1

-

2

16 E.

Fire Protection ~

-

-

-

-

-

F.

Emerg. Prep.

>

-

-

-

-

-

-

G.

Security

-

-

-

-

-

-

H.

Outages

-

-

-

-

-

-

I.

Quality / Admin

2

-

-

-

-

J.

Licensing

-

-

-

-

-

-

K.

Training / Qual.

-

-

-

-

-

-

Fffectiveness Totals

9

9

4

  • A - Personnel Error B - Design, Manufacturing or Installation Error C - External Cause D - Defective Procedures

.i E - Component Failure

'

X - Other

.

The above data are based upon LERs 85-11 through 85-63.

Three of these LERs l

reported two separate events which were assigned to separate functional areas and/or cause codes.

'

.

-

-

- -

- -

-

- -